Abstract

The gamma camera uptake method with Tc-99m-DTPA (diethylenetriaminepentaacetic acid) is a simple method for determination of glomerular filtration rate (GFR), and is less time-consuming than other methods, but its diagnostic accuracy is debated. Gate’s method (low-dose; LD), the high-dose method (HD), the predicted-clearance method, and the plasma-clearance method with Tc-99m-DTPA are compared in this study. We also performed GFR measurement and diuretic renography simultaneously. Tc-99m DTPA renography was performed in 36 patients aged 18–72 years with a wide range of renal function (serum creatinine 1.37 ± 0.49 mg/dl). GFR was determined by four methods: the gamma camera uptake method with low-dose Tc-99m DTPA (Gates, LD); the gamma camera uptake method with high-dose Tc-99m DTPA (HD); the predicted creatinine clearance method (Cockcroft–Gualt, CG); and the plasma sample clearance (PSC) method using a mono-exponential curve. The PSC method was chosen as reference. The regression equations for the CG, Gates (low-dose), and HD methods against the PSC method were 28.68 + 0.80X (r = 0.72; P value < 0.0001, RMSE = 21.65 ml/min/1.73 m2), 6.19 + 0.79X (r = 0.90; P value < 0.0001, RMSE = 10.64 ml/min/1.73 m2), and 6.53 + 0.88X (r = 0.93; P value < 0.0001, RMSE = 9.35 ml/min/1.73 m2), respectively. In comparison with determination of GFR by the PSC method, the CG method tended to overestimate GFR while, perversely, the LD and HD methods tended to underestimate GFR. The three methods were in agreement with the PSC method but the high-dose GFR method resulted in less error in estimation of GFR. Furthermore, GFR measurement and diuretic renography could be performed at the same time when the high-dose method was used. Because of the low cost and negligible radiation burden, this method might be preferred for routine practice in nuclear medicine.
Literature
1.
go back to reference Delpassand ES, Homayoon K, Madden T et al (2000) Determination of glomerular filtration rate using a dual-detector gamma camera and the geometric mean of renal activity: correlation with the Tc-99m DTPA plasma-clearance method. Clin Nucl Med 25(4):258–262. doi:10.1097/00003072-200004000-00004 PubMedCrossRef Delpassand ES, Homayoon K, Madden T et al (2000) Determination of glomerular filtration rate using a dual-detector gamma camera and the geometric mean of renal activity: correlation with the Tc-99m DTPA plasma-clearance method. Clin Nucl Med 25(4):258–262. doi:10.​1097/​00003072-200004000-00004 PubMedCrossRef
4.
go back to reference Itoh K (2003) Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method. Ann Nucl Med 17(7):561–565PubMed Itoh K (2003) Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method. Ann Nucl Med 17(7):561–565PubMed
5.
go back to reference Blaufox MD, Aurell M, Bubeck B et al (1996) Report of the Radionuclides in Nephrourology Committee on renal clearance. J Nucl Med 37(11):1883–1890PubMed Blaufox MD, Aurell M, Bubeck B et al (1996) Report of the Radionuclides in Nephrourology Committee on renal clearance. J Nucl Med 37(11):1883–1890PubMed
8.
go back to reference Shore RM, Koff SA, Hayes JR et al (1984) Glomerular filtration rate in children: determination from the Tc-99m-DTPA renogram. Radiology 151(3):627–633PubMed Shore RM, Koff SA, Hayes JR et al (1984) Glomerular filtration rate in children: determination from the Tc-99m-DTPA renogram. Radiology 151(3):627–633PubMed
9.
go back to reference De Santo NG, Anastasio P, Cirillo M et al (1999) Measurement of glomerular filtration rate by the 99mTc-DTPA renogram is less precise than measured and predicted creatinine clearance. Nephron 81(2):136–140. doi:10.1159/000045268 PubMedCrossRef De Santo NG, Anastasio P, Cirillo M et al (1999) Measurement of glomerular filtration rate by the 99mTc-DTPA renogram is less precise than measured and predicted creatinine clearance. Nephron 81(2):136–140. doi:10.​1159/​000045268 PubMedCrossRef
10.
go back to reference Swan SK (1997) The search continues—an ideal marker of GFR. Clin Chem 43(6 Pt 1):913–914 Swan SK (1997) The search continues—an ideal marker of GFR. Clin Chem 43(6 Pt 1):913–914
11.
go back to reference Hilson AJW, Mistry RD, Maisey MN (1976) Tc 99m-DTPA for the measurement of glomerular filtration rate. Br J Radiol 49:794–796PubMedCrossRef Hilson AJW, Mistry RD, Maisey MN (1976) Tc 99m-DTPA for the measurement of glomerular filtration rate. Br J Radiol 49:794–796PubMedCrossRef
12.
go back to reference Kempi V, Persson RBR (1974) Tc 99m-DTPA(Sn) dry-kit preparation. Quality control and clearance studies. Nucl Med (Stuttg) 13:389–399 Kempi V, Persson RBR (1974) Tc 99m-DTPA(Sn) dry-kit preparation. Quality control and clearance studies. Nucl Med (Stuttg) 13:389–399
13.
go back to reference Chantler C, Garnett ES, Parsons V et al (1969) Glomerular filtration rate measurement in man by the single injection methods using 51Cr-EDTA. Clin Sci 37(1):169–180PubMed Chantler C, Garnett ES, Parsons V et al (1969) Glomerular filtration rate measurement in man by the single injection methods using 51Cr-EDTA. Clin Sci 37(1):169–180PubMed
16.
go back to reference Hoek FJ, Kemperman FA, Krediet RT (2003) A comparison between cystatin C, plasma creatinine and the Cockcroft and Gault formula for the estimation of glomerular filtration rate. Nephrol Dial Transplant 18(10):2024–2031. doi:10.1093/ndt/gfg349 PubMedCrossRef Hoek FJ, Kemperman FA, Krediet RT (2003) A comparison between cystatin C, plasma creatinine and the Cockcroft and Gault formula for the estimation of glomerular filtration rate. Nephrol Dial Transplant 18(10):2024–2031. doi:10.​1093/​ndt/​gfg349 PubMedCrossRef
17.
go back to reference Jones J, Burnett PC (1974) Creatinine metabolism in humans with decreased renal function. Clin Chem 20(9):1204–1212PubMed Jones J, Burnett PC (1974) Creatinine metabolism in humans with decreased renal function. Clin Chem 20(9):1204–1212PubMed
18.
go back to reference Durand E, Prigent A, Gaillard J (1997) Comparison between 9 methods for estimation of glomerular filtration rate (GFR) with simultaneous injection of 51Cr-EDTA and 99mTc-DTPA. In: Taylor A Jr, Nally J, Thomsen H (eds) Radionuclides in nephrourology. Society of Nuclear Medicine, Reston, Virginia Durand E, Prigent A, Gaillard J (1997) Comparison between 9 methods for estimation of glomerular filtration rate (GFR) with simultaneous injection of 51Cr-EDTA and 99mTc-DTPA. In: Taylor A Jr, Nally J, Thomsen H (eds) Radionuclides in nephrourology. Society of Nuclear Medicine, Reston, Virginia
19.
go back to reference Tønnesen KH, Munch O, Hald T et al (1974) Influence in the radiorenogram of variation in skin to kidney distance and the clinical importance hereof. In: Zum Winkel K, Blaufox MD, Funck-Brentano JL (eds) Radionuclides in nephrology. George Thieme, Berlin Tønnesen KH, Munch O, Hald T et al (1974) Influence in the radiorenogram of variation in skin to kidney distance and the clinical importance hereof. In: Zum Winkel K, Blaufox MD, Funck-Brentano JL (eds) Radionuclides in nephrology. George Thieme, Berlin
21.
go back to reference Wang JY, Lu YS, Wang SJ et al (1995) Comparison and correlation of measurements of glomerular filtration rates by Tc-99m DTPA and 24-hour creatinine clearance. Zhonghua Yi Xue Za Zhi (Taipei) 55(6):432–437 Wang JY, Lu YS, Wang SJ et al (1995) Comparison and correlation of measurements of glomerular filtration rates by Tc-99m DTPA and 24-hour creatinine clearance. Zhonghua Yi Xue Za Zhi (Taipei) 55(6):432–437
23.
go back to reference Caride VJ, Zubal IG (1995) Assessment of the rate of uptake-plasma volume product to calculate glomerular filtration rate. J Nucl Med 36(9):1602–1604 (corrected) Caride VJ, Zubal IG (1995) Assessment of the rate of uptake-plasma volume product to calculate glomerular filtration rate. J Nucl Med 36(9):1602–1604 (corrected)
24.
go back to reference Mulligan JS, Blue PW, Hasbargen JA (1990) Methods for measuring GFR with technetium-99m-DTPA: an analysis of several common methods. J Nucl Med 31(7):1211–1219PubMed Mulligan JS, Blue PW, Hasbargen JA (1990) Methods for measuring GFR with technetium-99m-DTPA: an analysis of several common methods. J Nucl Med 31(7):1211–1219PubMed
Metadata
Title
Comparison of methods for determination of glomerular filtration rate: low and high-dose Tc-99m-DTPA renography, predicted creatinine clearance method, and plasma sample method
Authors
Majid Assadi
Mohammad Eftekhari
Mehrdad Hozhabrosadati
Mohsen Saghari
Abdolali Ebrahimi
Iraj Nabipour
Mohammad Zaki Abbasi
Darab Moshtaghi
Moloud Abbaszadeh
Sakineh Assadi
Publication date
01-12-2008
Publisher
Springer Netherlands
Published in
International Urology and Nephrology / Issue 4/2008
Print ISSN: 0301-1623
Electronic ISSN: 1573-2584
DOI
https://doi.org/10.1007/s11255-008-9446-4

Other articles of this Issue 4/2008

International Urology and Nephrology 4/2008 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.