Skip to main content
Top
Published in: Journal of Medical Systems 3/2015

01-03-2015 | Mobile Systems

A Wearable Wireless ECG Monitoring System With Dynamic Transmission Power Control for Long-Term Homecare

Authors: Yishan Wang, Sammy Doleschel, Ralf Wunderlich, Stefan Heinen

Published in: Journal of Medical Systems | Issue 3/2015

Login to get access

Abstract

This paper presents a wearable wireless ECG monitoring system based on novel 3-Lead electrode placements for long-term homecare. The experiment for novel 3-Lead electrode placements is carried out, and the results show that the distance between limb electrodes can be significantly reduced. Based on the new electrode position, a small size sensor node, which is powered by a rechargeable battery, is designed to detect, amplify, filter and transmit the ECG signals. The coordinator receives the data and sends it to PC. Finally the signals are displayed on the GUI. In order to control the power consumption of sensor node, a dynamic power adjustment method is applied to automatically adjust the transmission power of the sensor node according to the received signal strength indicator (RSSI), which is related to the distance and obstacle between sensor node and coordinator. The system is evaluated when the user, who wears the sensor, is walking and running. A promising performance is achieved even under body motion. The power consumption can be significantly reduced with this dynamic power adjustment method.
Literature
1.
go back to reference Wang, Y., Yu, K., Wang, D., Zhao, C., Wang, L. and Wang, P., “Multi-Model Diagnosis Method for Lung Cancer based on MOS-SAW Breath Detecting e-Nose,” in Proceedings of The 14th International Symposium on Olfaction and Electronic Nose, 2011. Wang, Y., Yu, K., Wang, D., Zhao, C., Wang, L. and Wang, P., “Multi-Model Diagnosis Method for Lung Cancer based on MOS-SAW Breath Detecting e-Nose,” in Proceedings of The 14th International Symposium on Olfaction and Electronic Nose, 2011.
2.
go back to reference Wang, Y., Hu, Y., Wang, D., Yu, K., Wang, L., Zou, Y., Zhao, C., Zhang, X., Wang, P., and Ying, K., The analysis of volatile organic compounds biomarkers for lung cancer in exhaled breath, tissues and cell lines. Cancer. Biomark. 11:129–137, 2012. Wang, Y., Hu, Y., Wang, D., Yu, K., Wang, L., Zou, Y., Zhao, C., Zhang, X., Wang, P., and Ying, K., The analysis of volatile organic compounds biomarkers for lung cancer in exhaled breath, tissues and cell lines. Cancer. Biomark. 11:129–137, 2012.
3.
go back to reference Cao, H., Li, H., Stocco, L., and Leung, V. C. M., Wireless three-pad ECG system: challenges, design, and evaluations. Commun. Net. J. 13:113–124, 2011.CrossRef Cao, H., Li, H., Stocco, L., and Leung, V. C. M., Wireless three-pad ECG system: challenges, design, and evaluations. Commun. Net. J. 13:113–124, 2011.CrossRef
4.
go back to reference Einthoven, W., Weiteres ueber das elektrokardiogram. Pflueger Arch. ges. Physiol. 122:517–584, 1908.CrossRef Einthoven, W., Weiteres ueber das elektrokardiogram. Pflueger Arch. ges. Physiol. 122:517–584, 1908.CrossRef
5.
go back to reference Wilson, F. N., Johnston, F. D., Rosenbaum, F. F., Erlanger, H., Kossmann, C. E., Hecht, H., Cotrim, N., Oliveira, R. M. d., Scarsi, R. and Barker, P. S., “The precordial electrocardiogram,” AHJ, vol. 27, pp. 19-85, 1944. Wilson, F. N., Johnston, F. D., Rosenbaum, F. F., Erlanger, H., Kossmann, C. E., Hecht, H., Cotrim, N., Oliveira, R. M. d., Scarsi, R. and Barker, P. S., “The precordial electrocardiogram,” AHJ, vol. 27, pp. 19-85, 1944.
6.
go back to reference Mason, R. E., and Likar, I., A new system of multiple-lead exercise electrocardiography. AHJ. 71:196–205, 1966.CrossRef Mason, R. E., and Likar, I., A new system of multiple-lead exercise electrocardiography. AHJ. 71:196–205, 1966.CrossRef
7.
go back to reference Dower, G. E., Yakush, A., Nazzal, S. B., Jutzy, R. V., and Ruiz, C. E., Deriving the 12-lead electrocardiogram from four (EASI) electrodes. J. Electrocardiol. 21:182–187, 1988.CrossRef Dower, G. E., Yakush, A., Nazzal, S. B., Jutzy, R. V., and Ruiz, C. E., Deriving the 12-lead electrocardiogram from four (EASI) electrodes. J. Electrocardiol. 21:182–187, 1988.CrossRef
8.
go back to reference Munshi, M., Xu, X., Zou, X., Soetiono, E., Teo, C. S. and Lian, Y., “Wireless ECG plaster for body sensor network,” in Proceedings of ISSS-MDBS 2008, 2008. Munshi, M., Xu, X., Zou, X., Soetiono, E., Teo, C. S. and Lian, Y., “Wireless ECG plaster for body sensor network,” in Proceedings of ISSS-MDBS 2008, 2008.
9.
go back to reference Masse, F., Penders, J., Serteyn, A., Bussel, M. van and Arends, J., “Miniaturized wireless ECG-monitor for real-time detection of epileptic seizures,” in Proceedings of Wireless Health 2010, 2010. Masse, F., Penders, J., Serteyn, A., Bussel, M. van and Arends, J., “Miniaturized wireless ECG-monitor for real-time detection of epileptic seizures,” in Proceedings of Wireless Health 2010, 2010.
10.
go back to reference Altini, M., Polito, S., Penders, J., Kim, H., Helleputte, N. Van, Kim, S. and Yazicioglu, F., “An ECG patch combining a customized ultra-low-power ECG SoC with bluetooth low energy for long term ambulatory monitoring,” in Proceedings of the 2nd Conference on Wireless Health, 2011. Altini, M., Polito, S., Penders, J., Kim, H., Helleputte, N. Van, Kim, S. and Yazicioglu, F., “An ECG patch combining a customized ultra-low-power ECG SoC with bluetooth low energy for long term ambulatory monitoring,” in Proceedings of the 2nd Conference on Wireless Health, 2011.
11.
go back to reference Hoekema, R., Uijen, G., and van Oosterom, A., On selecting a body surface mapping procedure. J. Electrocardiol. 32:93–101, 1999.CrossRef Hoekema, R., Uijen, G., and van Oosterom, A., On selecting a body surface mapping procedure. J. Electrocardiol. 32:93–101, 1999.CrossRef
12.
go back to reference Torfs, Yazicioglu, T. R., Kim, S., Kim, H., Hoof, C. Van, Buxi, D., Romero, I. a. W. J., Masse, F. and Penders, J., “Ultra low power wireless ECG system with beat detection and real time impedance measurement,” in Proceedings of IEEE BioCAS 2010 Conference, 2010. Torfs, Yazicioglu, T. R., Kim, S., Kim, H., Hoof, C. Van, Buxi, D., Romero, I. a. W. J., Masse, F. and Penders, J., “Ultra low power wireless ECG system with beat detection and real time impedance measurement,” in Proceedings of IEEE BioCAS 2010 Conference, 2010.
13.
go back to reference Gomez-Clapers, J., and Casanella, R., A fast and easy-to-use ECG acquisition and heart rate monitoring system using a wireless steering wheel. Sens. J. IEEE. 12:610–616, 2012.CrossRef Gomez-Clapers, J., and Casanella, R., A fast and easy-to-use ECG acquisition and heart rate monitoring system using a wireless steering wheel. Sens. J. IEEE. 12:610–616, 2012.CrossRef
14.
go back to reference Kim, S., and Eom, D., Link-state-estimation-based transmission power control in wireless body area networks. IEEE J-BHI. 18:1294–1302, 2014. Kim, S., and Eom, D., Link-state-estimation-based transmission power control in wireless body area networks. IEEE J-BHI. 18:1294–1302, 2014.
15.
go back to reference Wang, Y., Wunderlich, R. and Heinen, S., “Design and Evaluation of a Novel Wireless Reconstructed 3-Lead ECG Monitoring System,” in Proceedings of IEEE BioCAS 2013 Conference, 2013. Wang, Y., Wunderlich, R. and Heinen, S., “Design and Evaluation of a Novel Wireless Reconstructed 3-Lead ECG Monitoring System,” in Proceedings of IEEE BioCAS 2013 Conference, 2013.
16.
17.
go back to reference Wang. Y., Wunderlich. R. and Heinen. S., “A low noise wearable wireless ECG system with body motion cancellation for long term homecare,” in Proceedings of IEEE Healthcom 2013 Conference, 2013. Wang. Y., Wunderlich. R. and Heinen. S., “A low noise wearable wireless ECG system with body motion cancellation for long term homecare,” in Proceedings of IEEE Healthcom 2013 Conference, 2013.
18.
go back to reference A true system-on-chip solution for 2.4-GHz IEEE 802.15.4 and ZigBee applications. Texas Instruments Inc., 2011. A true system-on-chip solution for 2.4-GHz IEEE 802.15.4 and ZigBee applications. Texas Instruments Inc., 2011.
19.
go back to reference Andersen, A., 2.4 GHz inverted F antenna. Texas Instruments Inc., 2008. Andersen, A., 2.4 GHz inverted F antenna. Texas Instruments Inc., 2008.
20.
go back to reference USB 4-BIT SPI/FT1248 IC FT220X. Future Technology Devices International Ltd., 2014. USB 4-BIT SPI/FT1248 IC FT220X. Future Technology Devices International Ltd., 2014.
21.
go back to reference Xiao, S., Dhamdhere, A., Sivaraman, V., and Burdett, A., Transmission power control in body area sensor networks for healthcare monitoring. IEEE J-SAC. 27:37–48, 2009. Xiao, S., Dhamdhere, A., Sivaraman, V., and Burdett, A., Transmission power control in body area sensor networks for healthcare monitoring. IEEE J-SAC. 27:37–48, 2009.
22.
go back to reference Pan, J., and Tompkins, W. J., A real-time QRS detection algorithm. IEEE Trans. Biomed. Eng. BME-32:230–236, 1985.CrossRef Pan, J., and Tompkins, W. J., A real-time QRS detection algorithm. IEEE Trans. Biomed. Eng. BME-32:230–236, 1985.CrossRef
23.
go back to reference Burns, A., Doheny, E., Greene, B., Foran, T., Leahy, D., O’Donovan, K. and McGrath, M., “SHIMMER™: an extensible platform for physiological signal capture,” in Proceedings of Annual International Conference of IEEE EMBC 2010, 2010. Burns, A., Doheny, E., Greene, B., Foran, T., Leahy, D., O’Donovan, K. and McGrath, M., “SHIMMER™: an extensible platform for physiological signal capture,” in Proceedings of Annual International Conference of IEEE EMBC 2010, 2010.
24.
go back to reference Gaxiola-Sosa, J., Mohsin, N., Palliyali, A., Tafreshi, R. and Entesari, K., “A portable 12-lead ECG wireless medical system for continuous cardiac-activity monitoring,” in Proceedings of MECBME 2014, 2014. Gaxiola-Sosa, J., Mohsin, N., Palliyali, A., Tafreshi, R. and Entesari, K., “A portable 12-lead ECG wireless medical system for continuous cardiac-activity monitoring,” in Proceedings of MECBME 2014, 2014.
25.
go back to reference Gao, H., Duan, X., Guo, X., Huang, A. and Jiao, B., “Design and tests of a smartphones-based multi-lead ECG monitoring system,” in Proceedings of Annual International Conference of IEEE EMBC 2013, 2013. Gao, H., Duan, X., Guo, X., Huang, A. and Jiao, B., “Design and tests of a smartphones-based multi-lead ECG monitoring system,” in Proceedings of Annual International Conference of IEEE EMBC 2013, 2013.
26.
go back to reference Tan, T.-H., Chang, C.-S., Huang, Y.-F., Chen, Y.-F., and Lee, C., Development of a portable linux-based ECG measurement and monitoring system. J. Med. Syst. 35:559–569, 2011.CrossRef Tan, T.-H., Chang, C.-S., Huang, Y.-F., Chen, Y.-F., and Lee, C., Development of a portable linux-based ECG measurement and monitoring system. J. Med. Syst. 35:559–569, 2011.CrossRef
27.
go back to reference Winokur, E., Delano, M., and Sodini, C., A wearable cardiac monitor for long-term data acquisition and analysis. IEEE Trans. Biomed. Eng. 60:189–192, 2013.CrossRef Winokur, E., Delano, M., and Sodini, C., A wearable cardiac monitor for long-term data acquisition and analysis. IEEE Trans. Biomed. Eng. 60:189–192, 2013.CrossRef
28.
go back to reference Chen, H., Wu, W., and Lee, J., A WBAN-based real-time electroencephalogram monitoring system: design and implementation. J. Med. Syst. 34:303–311, 2010.CrossRef Chen, H., Wu, W., and Lee, J., A WBAN-based real-time electroencephalogram monitoring system: design and implementation. J. Med. Syst. 34:303–311, 2010.CrossRef
29.
go back to reference Fensli, R., Dale, J., O’Reilly, P., O’Donoghue, J., Sammon, D., and Gundersen, T., Towards improved healthcare performance: examining technological possibilities and patient satisfaction with wireless body area networks. J. Med. Syst. 34:767–775, 2010.CrossRef Fensli, R., Dale, J., O’Reilly, P., O’Donoghue, J., Sammon, D., and Gundersen, T., Towards improved healthcare performance: examining technological possibilities and patient satisfaction with wireless body area networks. J. Med. Syst. 34:767–775, 2010.CrossRef
30.
go back to reference Pantazis, N., and Vergados, D., A survey on power control issues in wireless sensor networks. IEEE Commun. Surv. Tutor. 9:86–107, 2007.CrossRef Pantazis, N., and Vergados, D., A survey on power control issues in wireless sensor networks. IEEE Commun. Surv. Tutor. 9:86–107, 2007.CrossRef
31.
go back to reference Zhou, G., He, T., Krishnamurthy, S. and Stankovic, J. A., “Impact of radio irregularity on wireless sensor networks,” in Proceedings of MobiSys 2004, 2004. Zhou, G., He, T., Krishnamurthy, S. and Stankovic, J. A., “Impact of radio irregularity on wireless sensor networks,” in Proceedings of MobiSys 2004, 2004.
32.
go back to reference Zhao, J. and Govindan, R., “Understanding packet delivery performance in dense wireless sensor networks,” in Proceedings of the 1st International Conference on Embedded Networked Sensor Systems, 2003. Zhao, J. and Govindan, R., “Understanding packet delivery performance in dense wireless sensor networks,” in Proceedings of the 1st International Conference on Embedded Networked Sensor Systems, 2003.
33.
go back to reference Malmivuo, J., and Plonsey, R., Bioelectromagnetism: principles and applications of bioelectric and biomagnetic fields. Oxford University Press, New York, 1995.CrossRef Malmivuo, J., and Plonsey, R., Bioelectromagnetism: principles and applications of bioelectric and biomagnetic fields. Oxford University Press, New York, 1995.CrossRef
34.
go back to reference Yanowitz, F. G., Introduction to ECG interpretation V8.0. Eccles Health Sciences Library University of Utah, Salt Lake City, 2012. Yanowitz, F. G., Introduction to ECG interpretation V8.0. Eccles Health Sciences Library University of Utah, Salt Lake City, 2012.
35.
go back to reference Welinder, A., Sörnmo, L., Field, D. Q., Feldman, C. L., Pettersson, J., Wagner, G. S., and Pahlm, O., Comparison of signal quality between easy and Mason-Likar 12-Lead electrocardiograms during physical activity. AJCC. 13:228–234, 2004. Welinder, A., Sörnmo, L., Field, D. Q., Feldman, C. L., Pettersson, J., Wagner, G. S., and Pahlm, O., Comparison of signal quality between easy and Mason-Likar 12-Lead electrocardiograms during physical activity. AJCC. 13:228–234, 2004.
Metadata
Title
A Wearable Wireless ECG Monitoring System With Dynamic Transmission Power Control for Long-Term Homecare
Authors
Yishan Wang
Sammy Doleschel
Ralf Wunderlich
Stefan Heinen
Publication date
01-03-2015
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 3/2015
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-015-0223-5

Other articles of this Issue 3/2015

Journal of Medical Systems 3/2015 Go to the issue