Skip to main content
Top
Published in: Journal of Medical Systems 4/2010

01-08-2010 | Original Paper

Towards Improved Healthcare Performance: Examining Technological Possibilities and Patient Satisfaction with Wireless Body Area Networks

Authors: Rune Fensli, Jan Gunnar Dale, Philip O’Reilly, John O’Donoghue, David Sammon, Torstein Gundersen

Published in: Journal of Medical Systems | Issue 4/2010

Login to get access

Abstract

This paper investigates the benefits of using less intrusive wireless technologies for heart monitoring. By replacing well established heart monitoring devices (i.e. Holter) with wireless ECG based Body Area Networks (BAN), improved healthcare performance can be achieved, reflected in (1) high quality ECG recordings during physical activities and (2) increased patient satisfaction. A small scale clinical trial was conducted to compare both technologies and the results illustrate that the wireless ECG monitor was able to detect ECG signals intended for arrhythmia diagnostics. Furthermore, from a patient’s perspective, both technologies were evaluated using three dimensions, namely; hygienic aspects, physical activity, and skin reactions. Results demonstrate that the wireless ECG BAN showed better performance, especially regarding the hygienic aspects. It was also favourable for use during physical activities, and the signal quality of the wireless sensor system demonstrated good performance regarding signal noise and artefact disturbances. This paper concludes that wireless cardiac monitoring systems have significant benefits from a patient’s perspective, and further clinical trials should be conducted to further evaluate the new ECG based BAN system, to identify the possibility of widespread adoption and utilisation of wireless technology for arrhythmia diagnostics.
Literature
1.
go back to reference Al Khatib, I., Bertozzi, D., Poletti, F., Benini, L., Jantsch, A., Bechara, M., Khalifeh, H., Hajjar, M., Nabiev, R., and Jonsson, S., Hardware/software architecture for real-time ECG monitoring and analysis leveraging MPSoC technology. Transactions on HiPEAC I, LNCS. 4050:239–258, 2007. Al Khatib, I., Bertozzi, D., Poletti, F., Benini, L., Jantsch, A., Bechara, M., Khalifeh, H., Hajjar, M., Nabiev, R., and Jonsson, S., Hardware/software architecture for real-time ECG monitoring and analysis leveraging MPSoC technology. Transactions on HiPEAC I, LNCS. 4050:239–258, 2007.
2.
go back to reference Guler, N. F., and Ubeyli, E. D., Theory and applications of telemedicine. J. Med. Syst. 26:199–220, 2002.CrossRef Guler, N. F., and Ubeyli, E. D., Theory and applications of telemedicine. J. Med. Syst. 26:199–220, 2002.CrossRef
3.
go back to reference Jovanov, E., Raskovic, D., Price, J., Chapman, J., Moore, A., and Krishnamurthy, A., Patient monitoring using personal area networks of wireless intelligent sensors. Biomed. Sci. Instrum. 37:373–378, 2001. Jovanov, E., Raskovic, D., Price, J., Chapman, J., Moore, A., and Krishnamurthy, A., Patient monitoring using personal area networks of wireless intelligent sensors. Biomed. Sci. Instrum. 37:373–378, 2001.
4.
go back to reference Anliker, U., Ward, J. A., Lukowicz, P., Troster, G., Dolveck, F., Baer, M., et al., AMON: a wearable multiparameter medical monitoring and alert system. Information Technology in Biomedicine. IEEE Trans. 8 (4)415–427, 2004. Anliker, U., Ward, J. A., Lukowicz, P., Troster, G., Dolveck, F., Baer, M., et al., AMON: a wearable multiparameter medical monitoring and alert system. Information Technology in Biomedicine. IEEE Trans. 8 (4)415–427, 2004.
7.
go back to reference Marculescu, D., Marculescu, R., Zamora, N. H., Stanley-Marbell, P., Khosla, P. K., Park, S., et al., Electronic textiles: A platform for pervasive computing. Proc. IEEE. 91 (12)1995–2018, 2003. doi:10.1109/JPROC.2003.819612.CrossRef Marculescu, D., Marculescu, R., Zamora, N. H., Stanley-Marbell, P., Khosla, P. K., Park, S., et al., Electronic textiles: A platform for pervasive computing. Proc. IEEE. 91 (12)1995–2018, 2003. doi:10.​1109/​JPROC.​2003.​819612.CrossRef
8.
go back to reference Park, S., Jayaraman, S., On innovation, quality of life and technology of BodyNets’ Proceedings of the ICST 3rd international conference on Body area networks. Tempe, Arizona: ICST Institute for Computer Sciences, Social-Informatics and Telecommunications Engineering, 2008. Park, S., Jayaraman, S., On innovation, quality of life and technology of BodyNets’ Proceedings of the ICST 3rd international conference on Body area networks. Tempe, Arizona: ICST Institute for Computer Sciences, Social-Informatics and Telecommunications Engineering, 2008.
12.
go back to reference Tan, J., E-Healthcare Information Systems: An Introduction for Students and Professionals, Wiley, 2005. Tan, J., E-Healthcare Information Systems: An Introduction for Students and Professionals, Wiley, 2005.
13.
go back to reference Passanisi, C., Electrocardiography Essentials. Delmar Learning. 2001. Passanisi, C., Electrocardiography Essentials. Delmar Learning. 2001.
15.
go back to reference Bunch, T., White, R., Gersh, B., Meverden, R., Hodge, D., Ballman, K., Hammill, S., Shen, W., and Packer, D., Long-term outcomes of out-of-hospital cardiac arrest after successful early defibrillation. N. Engl. J. Med. 348:2626–2633, 2003. doi:10.1056/NEJMoa023053.CrossRef Bunch, T., White, R., Gersh, B., Meverden, R., Hodge, D., Ballman, K., Hammill, S., Shen, W., and Packer, D., Long-term outcomes of out-of-hospital cardiac arrest after successful early defibrillation. N. Engl. J. Med. 348:2626–2633, 2003. doi:10.​1056/​NEJMoa023053.CrossRef
17.
go back to reference Hoch, J. S., Rockx, M., and Krahn, A., Using the net benefit regression framework to construct cost-effectiveness acceptrability curves: an example using data from a trial of external loop recorders versus Holter monitoring for ambulatory monitoring of community acquired syncope. in BMC Health Service Results, June, 2006. Hoch, J. S., Rockx, M., and Krahn, A., Using the net benefit regression framework to construct cost-effectiveness acceptrability curves: an example using data from a trial of external loop recorders versus Holter monitoring for ambulatory monitoring of community acquired syncope. in BMC Health Service Results, June, 2006.
18.
go back to reference Fensli, R., Pedersen, P. E., et al., Sensor Acceptance Model—Measuring patient acceptance of wearable sensors. Methods Inf. Med. 47 (1)89–95, 2008. Fensli, R., Pedersen, P. E., et al., Sensor Acceptance Model—Measuring patient acceptance of wearable sensors. Methods Inf. Med. 47 (1)89–95, 2008.
19.
go back to reference Istepanian, R., Woodward, B., Gorilas, E., and Balos, P., Designing of mobile telemedicine systems using GSM and IS-54 cellular telephone standards. J. Telemed. Telecare. 4 (1)80–82, 1998. doi:10.1258/1357633981931579.CrossRef Istepanian, R., Woodward, B., Gorilas, E., and Balos, P., Designing of mobile telemedicine systems using GSM and IS-54 cellular telephone standards. J. Telemed. Telecare. 4 (1)80–82, 1998. doi:10.​1258/​1357633981931579​.CrossRef
20.
go back to reference Andreasson, J., Ekstrom, M., Fard, A., Castano, J., Johnson, T., Remote system for patient monitoring using bluetooth. Sensors-02, Proceedings of the IEEE, 2002. Andreasson, J., Ekstrom, M., Fard, A., Castano, J., Johnson, T., Remote system for patient monitoring using bluetooth. Sensors-02, Proceedings of the IEEE, 2002.
21.
go back to reference Scherr, D., Dalal, D., Henrikson, C., Spragg, D., Berger, R., Calkins, H., and Cheng, A., Prospective comparison of the diagnostic utility of a standard event monitor versus a “leadless” portable ECG monitor in the evaluation of patients with palpitations. J. Interv. Card. Electrophysiol. 22:1, 2008. doi:10.1007/s10840-008-9251-0.CrossRef Scherr, D., Dalal, D., Henrikson, C., Spragg, D., Berger, R., Calkins, H., and Cheng, A., Prospective comparison of the diagnostic utility of a standard event monitor versus a “leadless” portable ECG monitor in the evaluation of patients with palpitations. J. Interv. Card. Electrophysiol. 22:1, 2008. doi:10.​1007/​s10840-008-9251-0.CrossRef
24.
go back to reference Fensli, R., and Boisen, E., Human factors affecting the patient’s acceptance of wireless biomedical sensors. In: Fred, A., Filipe, J., and Gamboa, H., (Eds.), BIOSTEC 2008, CCIS 25.402–12. Berlin Heidelberg: Springer, 2008. Fensli, R., and Boisen, E., Human factors affecting the patient’s acceptance of wireless biomedical sensors. In: Fred, A., Filipe, J., and Gamboa, H., (Eds.), BIOSTEC 2008, CCIS 25.402–12. Berlin Heidelberg: Springer, 2008.
25.
go back to reference Giorgi, A., Aanstoos, C. M., and William, F. F., Phenomenology and psychological research. Duquesne University Press, Pittsburgh, 1985. Giorgi, A., Aanstoos, C. M., and William, F. F., Phenomenology and psychological research. Duquesne University Press, Pittsburgh, 1985.
26.
go back to reference Bland, J. M., and Altman, D. G., Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1 (8476)307–310, 1986. Bland, J. M., and Altman, D. G., Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1 (8476)307–310, 1986.
Metadata
Title
Towards Improved Healthcare Performance: Examining Technological Possibilities and Patient Satisfaction with Wireless Body Area Networks
Authors
Rune Fensli
Jan Gunnar Dale
Philip O’Reilly
John O’Donoghue
David Sammon
Torstein Gundersen
Publication date
01-08-2010
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 4/2010
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-009-9291-8

Other articles of this Issue 4/2010

Journal of Medical Systems 4/2010 Go to the issue