Evaluation of the conventional and modified aerosol boxes during tracheal intubation in normal and difficult airways: a randomized, crossover, manikin simulation study

Authors: Hyerim Kim, Jee-Eun Chang, Dae Kon Kim, Dongwook Won, Jung-Man Lee, Tae Kyong Kim, Seong-Won Min, Haeun Lim, Seoyoung Ma, Jin-Young Hwang

Published in: Journal of Clinical Monitoring and Computing | Issue 6/2022

Login to get access

Abstract

The aim of this study was to evaluate conventional and modified aerosol boxes in terms of intubation time, first-pass intubation success, and mouth-to-mouth distance between the laryngoscopist and patient during tracheal intubation in simulated patients with normal and difficult airways. Sixteen anesthesiologists performed tracheal intubations with direct laryngoscope or three different videolaryngoscopes (McGRATH MAC videolaryngoscope, C-MAC videolaryngoscope, and Pentax-AWS) without an aerosol box or with a conventional or a modified aerosol boxes in simulated manikins with normal and difficult airways. Intubation time, first-pass intubation success, and mouth-to-mouth distance during tracheal intubation were recorded. Compared to no aerosol box, the use of a conventional aerosol box significantly increased intubation time in both normal and difficult airways (Bonferroni-corrected P-value (Pcorrected) = 0.005 and Pcorrected = 0.003, respectively). Intubation time was significantly shorter with the modified aerosol box than with the conventional one for both normal and difficult airways (Pcorrected = 0.003 and Pcorrected = 0.011, respectively). However, no significant differences were found in intubation time between no aerosol box and the modified aerosol box for normal and difficult airways (Pcorrected = 0.336 and Pcorrected = 0.112, respectively). The use of conventional or modified aerosol boxes significantly extended the mouth-to-mouth distances compared to not using an aerosol box during tracheal intubation with each laryngoscope (all Pcorrected < 0.05), and the distances were not different between the conventional and modified boxes in normal and difficult airways. The use of modified aerosol box did not increase intubation time and could help maintain a distance from the simulated patients with normal and difficult airways.
Literature
1.
go back to reference Wang W, Xu Y, Gao R, Lu R, Han K, Wu G, et al. Detection of SARS-CoV-2 in different types of clinical specimens. JAMA. 2020;323:1843–4.PubMedPubMedCentral Wang W, Xu Y, Gao R, Lu R, Han K, Wu G, et al. Detection of SARS-CoV-2 in different types of clinical specimens. JAMA. 2020;323:1843–4.PubMedPubMedCentral
2.
go back to reference van Doremalen N, Bushmaker T, Morris DH, Holbrook MG, Gamble A, Williamson BN, et al. Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1. N Engl J Med. 2020;382:1564–7.CrossRefPubMed van Doremalen N, Bushmaker T, Morris DH, Holbrook MG, Gamble A, Williamson BN, et al. Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1. N Engl J Med. 2020;382:1564–7.CrossRefPubMed
3.
go back to reference Wilson NM, Norton A, Young FP, Collins DW. Airborne transmission of severe acute respiratory syndrome coronavirus-2 to healthcare workers: a narrative review. Anaesthesia. 2020;75:1086–95.CrossRefPubMedPubMedCentral Wilson NM, Norton A, Young FP, Collins DW. Airborne transmission of severe acute respiratory syndrome coronavirus-2 to healthcare workers: a narrative review. Anaesthesia. 2020;75:1086–95.CrossRefPubMedPubMedCentral
4.
go back to reference El-Boghdadly K, Wong DJN, Owen R, Neuman MD, Pocock S, Carlisle JB, et al. Risks to healthcare workers following tracheal intubation of patients with COVID-19: a prospective international multicentre cohort study. Anaesthesia. 2020;75:1437–47.CrossRefPubMedPubMedCentral El-Boghdadly K, Wong DJN, Owen R, Neuman MD, Pocock S, Carlisle JB, et al. Risks to healthcare workers following tracheal intubation of patients with COVID-19: a prospective international multicentre cohort study. Anaesthesia. 2020;75:1437–47.CrossRefPubMedPubMedCentral
5.
go back to reference Tran K, Cimon K, Severn M, Pessoa-Silva CL, Conly J. Aerosol generating procedures and risk of transmission of acute respiratory infections to healthcare workers: a systematic review. PLoS ONE. 2012;7:e35797.CrossRefPubMedPubMedCentral Tran K, Cimon K, Severn M, Pessoa-Silva CL, Conly J. Aerosol generating procedures and risk of transmission of acute respiratory infections to healthcare workers: a systematic review. PLoS ONE. 2012;7:e35797.CrossRefPubMedPubMedCentral
6.
go back to reference Jackson T, Deibert D, Wyatt G, Durand-Moreau Q, Adisesh A, Khunti K, et al. Classification of aerosol-generating procedures: a rapid systematic review. BMJ Open Respir Res. 2020;7:e000730.CrossRefPubMedPubMedCentral Jackson T, Deibert D, Wyatt G, Durand-Moreau Q, Adisesh A, Khunti K, et al. Classification of aerosol-generating procedures: a rapid systematic review. BMJ Open Respir Res. 2020;7:e000730.CrossRefPubMedPubMedCentral
7.
go back to reference Chao CYH, Wan MP, Morawska L, Johnson GR, Ristovski ZD, Hargreaves M, et al. Characterization of expiration air jets and droplet size distributions immediately at the mouth opening. J Aerosol Sci. 2009;40:122–33.CrossRefPubMed Chao CYH, Wan MP, Morawska L, Johnson GR, Ristovski ZD, Hargreaves M, et al. Characterization of expiration air jets and droplet size distributions immediately at the mouth opening. J Aerosol Sci. 2009;40:122–33.CrossRefPubMed
9.
go back to reference Begley JL, Lavery KE, Nickson CP, Brewster DJ. The aerosol box for intubation in coronavirus disease 2019 patients: an in-situ simulation crossover study. Anaesthesia. 2020;75:1014–21.CrossRefPubMedPubMedCentral Begley JL, Lavery KE, Nickson CP, Brewster DJ. The aerosol box for intubation in coronavirus disease 2019 patients: an in-situ simulation crossover study. Anaesthesia. 2020;75:1014–21.CrossRefPubMedPubMedCentral
10.
go back to reference Cook TM, El-Boghdadly K, McGuire B, McNarry AF, Patel A, Higgs A. Consensus guidelines for managing the airway in patients with COVID-19: Guidelines from the Difficult Airway Society, the Association of Anaesthetists the Intensive Care Society, the Faculty of Intensive Care Medicine and the Royal College of Anaesthetists. Anaesthesia. 2020;75:785–99.CrossRefPubMedPubMedCentral Cook TM, El-Boghdadly K, McGuire B, McNarry AF, Patel A, Higgs A. Consensus guidelines for managing the airway in patients with COVID-19: Guidelines from the Difficult Airway Society, the Association of Anaesthetists the Intensive Care Society, the Faculty of Intensive Care Medicine and the Royal College of Anaesthetists. Anaesthesia. 2020;75:785–99.CrossRefPubMedPubMedCentral
11.
go back to reference Hall D, Steel A, Heij R, Eley A, Young P. Videolaryngoscopy increases “mouth-to-mouth” distance compared with direct laryngoscopy. Anaesthesia. 2020;75:822–3.CrossRefPubMed Hall D, Steel A, Heij R, Eley A, Young P. Videolaryngoscopy increases “mouth-to-mouth” distance compared with direct laryngoscopy. Anaesthesia. 2020;75:822–3.CrossRefPubMed
12.
go back to reference Bowdle A, Jelacic S, Shishido S, Munoz-Price LS. Infection prevention precautions for routine anesthesia care during the SARS-CoV-2 pandemic. Anesth Analg. 2020;131:1342–54.CrossRefPubMed Bowdle A, Jelacic S, Shishido S, Munoz-Price LS. Infection prevention precautions for routine anesthesia care during the SARS-CoV-2 pandemic. Anesth Analg. 2020;131:1342–54.CrossRefPubMed
13.
go back to reference Dalli J, Khan MF, Marsh B, Nolan K, Cahill RA. Evaluating intubation boxes for airway management. Br J Anaesth. 2020;125:e293–5.CrossRefPubMed Dalli J, Khan MF, Marsh B, Nolan K, Cahill RA. Evaluating intubation boxes for airway management. Br J Anaesth. 2020;125:e293–5.CrossRefPubMed
15.
go back to reference Simpson JP, Wong DN, Verco L, Carter R, Dzidowski M, Chan PY. Measurement of airborne particle exposure during simulated tracheal intubation using various proposed aerosol containment devices during the COVID-19 pandemic. Anaesthesia. 2020;75:1587–95.CrossRefPubMedPubMedCentral Simpson JP, Wong DN, Verco L, Carter R, Dzidowski M, Chan PY. Measurement of airborne particle exposure during simulated tracheal intubation using various proposed aerosol containment devices during the COVID-19 pandemic. Anaesthesia. 2020;75:1587–95.CrossRefPubMedPubMedCentral
16.
go back to reference Sorbello M, Rosenblatt W, Hofmeyr R, Greif R, Urdaneta F. Aerosol boxes and barrier enclosures for airway management in COVID-19 patients: a scoping review and narrative synthesis. Br J Anaesth. 2020;125:880–94.CrossRefPubMed Sorbello M, Rosenblatt W, Hofmeyr R, Greif R, Urdaneta F. Aerosol boxes and barrier enclosures for airway management in COVID-19 patients: a scoping review and narrative synthesis. Br J Anaesth. 2020;125:880–94.CrossRefPubMed
17.
go back to reference Hofmeyr R, Sorbello M. Airway management in covid-19: time to start thinking outside the box? S Afr J Anaesth Analg. 2021;27:4–11.CrossRef Hofmeyr R, Sorbello M. Airway management in covid-19: time to start thinking outside the box? S Afr J Anaesth Analg. 2021;27:4–11.CrossRef
18.
go back to reference Sorbello M, Morello G, Pintaudi S, Cataldo R. COVID-19: intubation kit, intubation team, or intubation spots? Anesth Analg. 2020;131:e128–30.CrossRefPubMed Sorbello M, Morello G, Pintaudi S, Cataldo R. COVID-19: intubation kit, intubation team, or intubation spots? Anesth Analg. 2020;131:e128–30.CrossRefPubMed
Metadata
Title
Evaluation of the conventional and modified aerosol boxes during tracheal intubation in normal and difficult airways: a randomized, crossover, manikin simulation study
Authors
Hyerim Kim
Jee-Eun Chang
Dae Kon Kim
Dongwook Won
Jung-Man Lee
Tae Kyong Kim
Seong-Won Min
Haeun Lim
Seoyoung Ma
Jin-Young Hwang
Publication date
20-01-2022
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 6/2022
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-022-00814-4

Other articles of this Issue 6/2022

Journal of Clinical Monitoring and Computing 6/2022 Go to the issue