Abstract

Respiratory rate (RR) is a key vital sign that has been traditionally employed in the clinical assessment of patients and in the prevention of respiratory compromise. Despite its relevance, current practice for monitoring RR in non-intubated patients strongly relies on visual counting, which delivers an intermittent and error-prone assessment of the respiratory status. Here, we present a novel non-invasive respiratory monitor that continuously measures the RR in human subjects. The respiratory activity of the user is inferred by sensing the thermal transfer between the breathing airflow and a temperature sensor placed between the nose and the mouth. The performance of the respiratory monitor is assessed through respiratory experiments performed on healthy subjects. Under spontaneous breathing, the mean RR difference between our respiratory monitor and visual counting was 0.4 breaths per minute (BPM), with a 95% confidence interval equal to [− 0.5, 1.3] BPM. The robustness of the respiratory sensor to the position is assessed by studying the signal-to-noise ratio in different locations on the upper lip, displaying a markedly better performance than traditional thermal sensors used for respiratory airflow measurements.
Literature
1.
go back to reference Addison PS, Watson JN, Mestek ML, Mecca RS. Developing an algorithm for pulse oximetry derived respiratory rate (RRoxi): a healthy volunteer study. J Clin Monit Comput. 2012;26(1):45–51.CrossRef Addison PS, Watson JN, Mestek ML, Mecca RS. Developing an algorithm for pulse oximetry derived respiratory rate (RRoxi): a healthy volunteer study. J Clin Monit Comput. 2012;26(1):45–51.CrossRef
2.
go back to reference Addison PS, Watson JN, Mestek ML, Ochs JP, Uribe Alberto A, Bergese Sergio D. Pulse oximetry-derived respiratory rate in general care floor patients. J Clin Monit Comput. 2014;29(1):113–20.CrossRef Addison PS, Watson JN, Mestek ML, Ochs JP, Uribe Alberto A, Bergese Sergio D. Pulse oximetry-derived respiratory rate in general care floor patients. J Clin Monit Comput. 2014;29(1):113–20.CrossRef
3.
go back to reference Cavalcante AN, Martin YN, Sprung J, Imsirovic J, Weingarten TN. Low minute ventilation episodes during anesthesia recovery following intraperitoneal surgery as detected by a non-invasive respiratory volume monitor. J Clin Monit Comput. 2017;32(5):929–35.CrossRef Cavalcante AN, Martin YN, Sprung J, Imsirovic J, Weingarten TN. Low minute ventilation episodes during anesthesia recovery following intraperitoneal surgery as detected by a non-invasive respiratory volume monitor. J Clin Monit Comput. 2017;32(5):929–35.CrossRef
4.
go back to reference Cretikos MA, Bellomo R, Hillman K, Chen J, Finfer Simon, Flabouris Arthas. Respiratory rate: the neglected vital sign. Med J Aust. 2008;188(11):657–9.CrossRef Cretikos MA, Bellomo R, Hillman K, Chen J, Finfer Simon, Flabouris Arthas. Respiratory rate: the neglected vital sign. Med J Aust. 2008;188(11):657–9.CrossRef
5.
go back to reference Dahan A, Aarts L, Smith TW. Incidence, reversal, and prevention of opioid-induced respiratory depression. Anesthesiology. 2010;112(1):226–38.CrossRef Dahan A, Aarts L, Smith TW. Incidence, reversal, and prevention of opioid-induced respiratory depression. Anesthesiology. 2010;112(1):226–38.CrossRef
6.
go back to reference Folke M, Cernerud L, Ekström M, Hök B. Critical review of non-invasive respiratory monitoring in medical care. Med Biol Eng Comput. 2003;41(4):377–83.CrossRef Folke M, Cernerud L, Ekström M, Hök B. Critical review of non-invasive respiratory monitoring in medical care. Med Biol Eng Comput. 2003;41(4):377–83.CrossRef
7.
go back to reference Güder F, Ainla A, Redston J, Mosadegh B, Glavan Ana, Martin TJ, Whitesides George M. Paper-based electrical respiration sensor. Angewandte Chemie Int Ed. 2016;55(19):5727–32.CrossRef Güder F, Ainla A, Redston J, Mosadegh B, Glavan Ana, Martin TJ, Whitesides George M. Paper-based electrical respiration sensor. Angewandte Chemie Int Ed. 2016;55(19):5727–32.CrossRef
8.
go back to reference Guechi Y, Pichot A, Frasca D, Rayeh-Pelardy F, Lardeur Jean-Yves, Mimoz Olivier. Assessment of noninvasive acoustic respiration rate monitoring in patients admitted to an emergency department for drug or alcoholic poisoning. J Clin Monit Comput. 2015;29(6):721–6.CrossRef Guechi Y, Pichot A, Frasca D, Rayeh-Pelardy F, Lardeur Jean-Yves, Mimoz Olivier. Assessment of noninvasive acoustic respiration rate monitoring in patients admitted to an emergency department for drug or alcoholic poisoning. J Clin Monit Comput. 2015;29(6):721–6.CrossRef
9.
go back to reference Hochhausen N, Barbosa Pereira C, Leonhardt S, Rossaint R, Czaplik Michael. Estimating respiratory rate in post-anesthesia care unit patients using infrared thermography: an observational study. Sensors. 2018;18(5):1618.CrossRef Hochhausen N, Barbosa Pereira C, Leonhardt S, Rossaint R, Czaplik Michael. Estimating respiratory rate in post-anesthesia care unit patients using infrared thermography: an observational study. Sensors. 2018;18(5):1618.CrossRef
10.
go back to reference Hogan J. Why don’t nurses monitor the respiratory rates of patients? Br J Nurs. 2006;15(9):489–92.CrossRef Hogan J. Why don’t nurses monitor the respiratory rates of patients? Br J Nurs. 2006;15(9):489–92.CrossRef
11.
go back to reference Knaus WA, Zimmerman JE, Wagner DP, Draper EA, Lawrence DE. APACHE-acute physiology and chronic health evaluation: a physiologically based classification system. Crit Care Med. 1981;9(8):591–7.CrossRef Knaus WA, Zimmerman JE, Wagner DP, Draper EA, Lawrence DE. APACHE-acute physiology and chronic health evaluation: a physiologically based classification system. Crit Care Med. 1981;9(8):591–7.CrossRef
12.
go back to reference Lee LA, Caplan RA, Stephens LS, Posner KL, Terman Gregory W, Voepel-Lewis Terri, Domino Karen B. Postoperative opioid-induced respiratory depression. Anesthesiology. 2015;122:659–65.CrossRef Lee LA, Caplan RA, Stephens LS, Posner KL, Terman Gregory W, Voepel-Lewis Terri, Domino Karen B. Postoperative opioid-induced respiratory depression. Anesthesiology. 2015;122:659–65.CrossRef
13.
go back to reference Lee PJ. Clinical evaluation of a novel respiratory rate monitor. J Clin Monit Comput. 2016;30:175–83.CrossRef Lee PJ. Clinical evaluation of a novel respiratory rate monitor. J Clin Monit Comput. 2016;30:175–83.CrossRef
14.
go back to reference Li MH, Yadollahi A, Taati B. Noncontact vision-based cardiopulmonary monitoring in different sleeping positions. IEEE J Biomed Health Inform. 2017;21(5):1367–75.CrossRef Li MH, Yadollahi A, Taati B. Noncontact vision-based cardiopulmonary monitoring in different sleeping positions. IEEE J Biomed Health Inform. 2017;21(5):1367–75.CrossRef
15.
go back to reference Loughlin PC, Sebat F, Kellett JG. Respiratory rate: the forgotten vital sign - make it count!. Jt Comm J Qual Patient Saf. 2018;44(8):494–9.CrossRef Loughlin PC, Sebat F, Kellett JG. Respiratory rate: the forgotten vital sign - make it count!. Jt Comm J Qual Patient Saf. 2018;44(8):494–9.CrossRef
16.
go back to reference Lu W, Nystrom MM, Parikh PJ, Fooshee DR, Hubenschmidt James P, Bradley Jeffrey D, Low Daniel A. A semi-automatic method for peak and valley detection in free-breathing respiratory waveforms. Med Phys. 2006;33(10):3634–6.CrossRef Lu W, Nystrom MM, Parikh PJ, Fooshee DR, Hubenschmidt James P, Bradley Jeffrey D, Low Daniel A. A semi-automatic method for peak and valley detection in free-breathing respiratory waveforms. Med Phys. 2006;33(10):3634–6.CrossRef
17.
go back to reference Mimoz O, Benard T, Gaucher A, Frasca D, Debaene B. Accuracy of respiratory rate monitoring using a non-invasive acoustic method after general anaesthesia. Br J Anaesth. 2012;108(5):872–5.CrossRef Mimoz O, Benard T, Gaucher A, Frasca D, Debaene B. Accuracy of respiratory rate monitoring using a non-invasive acoustic method after general anaesthesia. Br J Anaesth. 2012;108(5):872–5.CrossRef
18.
go back to reference van Gastel M, Stuijk S, de Haan G. Robust respiration detection from remote photoplethysmography. Biomed Opt Express. 2016;7(12):4941–57.CrossRef van Gastel M, Stuijk S, de Haan G. Robust respiration detection from remote photoplethysmography. Biomed Opt Express. 2016;7(12):4941–57.CrossRef
19.
go back to reference Voscopoulos C, Brayanov J, Ladd D, Lalli M, Panasyuk Alexander, Freeman Jenny. Evaluation of a novel noninvasive respiration monitor providing continuous measurement of minute ventilation in ambulatory subjects in a variety of clinical scenarios. Anesth Analg. 2013;117(1):91–100.CrossRef Voscopoulos C, Brayanov J, Ladd D, Lalli M, Panasyuk Alexander, Freeman Jenny. Evaluation of a novel noninvasive respiration monitor providing continuous measurement of minute ventilation in ambulatory subjects in a variety of clinical scenarios. Anesth Analg. 2013;117(1):91–100.CrossRef
20.
go back to reference Wang S, Pohl A, Jaeschke T, Czaplik M, Köny M, Leonhardt S, Pohl N. A novel ultra-wideband 80 ghz fmcw radar system for contactless monitoring of vital signs. In: 2015 37th annual international conference of the IEEE engineering in medicine and biology society (EMBC). IEEE; 2015. pp. 4978–4981. Wang S, Pohl A, Jaeschke T, Czaplik M, Köny M, Leonhardt S, Pohl N. A novel ultra-wideband 80 ghz fmcw radar system for contactless monitoring of vital signs. In: 2015 37th annual international conference of the IEEE engineering in medicine and biology society (EMBC). IEEE; 2015. pp. 4978–4981.
21.
go back to reference Zhang Xuezheng, Kassem Mahmoud Attia Mohamed, Zhou Ying, Shabsigh Muhammad, Wang Quanguang, Xuzhong Xu. A Brief Review of Non-invasive Monitoring of Respiratory Condition for Extubated Patients with or at Risk for Obstructive Sleep Apnea after Surgery. Frontiers in Medicine. 2017;4(March):1–6. Zhang Xuezheng, Kassem Mahmoud Attia Mohamed, Zhou Ying, Shabsigh Muhammad, Wang Quanguang, Xuzhong Xu. A Brief Review of Non-invasive Monitoring of Respiratory Condition for Extubated Patients with or at Risk for Obstructive Sleep Apnea after Surgery. Frontiers in Medicine. 2017;4(March):1–6.
Metadata
Title
Non-invasive continuous respiratory monitoring using temperature-based sensors
Authors
Daniel E. Hurtado
Angel Abusleme
Javier A. P. Chávez
Publication date
01-04-2020
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 2/2020
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-019-00329-5

Other articles of this Issue 2/2020

Journal of Clinical Monitoring and Computing 2/2020 Go to the issue