Skip to main content
Top
Published in: Journal of Interventional Cardiac Electrophysiology 1/2016

01-10-2016

Steerable versus non-steerable sheaths during pulmonary vein isolation: impact of left atrial enlargement on the catheter–tissue contact force

Authors: Masaharu Masuda, Masashi Fujita, Osamu Iida, Shin Okamoto, Takayuki Ishihara, Kiyonori Nanto, Takashi Kanda, Tatsuya Shiraki, Akihiro Sunaga, Yasuhiro Matsuda, Masaaki Uematsu

Published in: Journal of Interventional Cardiac Electrophysiology | Issue 1/2016

Login to get access

Abstract

Purpose

The influence of left atrial (LA) enlargement on the efficacy of steerable sheath usage during pulmonary vein (PV) isolation is poorly understood. Here, we compared the catheter–tissue contact force (CF) and clinical outcomes between steerable and non-steerable sheaths among patients with different severities of LA enlargement.

Methods

In this prospective observational study, 90 consecutive atrial fibrillation patients scheduled for PV isolation (paroxysmal, 67 %) were enrolled and divided into tertiles of the LA volume (LA1, <124 cm3; LA2, 124 to 145 cm3; LA3, ≥146 cm3). An ipsilateral PV isolation was completed using either a steerable (n = 57) or non-steerable sheath (n = 33).

Results

The average CF of each ipsilateral PV was lower in the LA3 group (right 13.8 ± 5.8 g; left 9.7 ± 5.2 g) than LA1 (right 15.6 ± 6.8 g, p = 0.005; left 12.5 ± 5.6 g, p < 0.0001) or LA2 (right 15.2 ± 7.3 g, p = 0.04; left 12.6 ± 5.3 g, p < 0.0001) groups. In total, the average CF around the left PVs was significantly higher with steerable sheaths than without (12.7 ± 5.5 vs. 10.2 ± 4.9 g, p = 0.03). Subgroup analysis revealed that a tendency toward higher CF around the left PVs was observed in the LA3 group (12.3 ± 7.3 vs. 8.5 ± 3.9 g, p = 0.08) but was not in the LA1 and LA2 groups. Further, in the LA3 group, steerable sheath usage showed better clinical outcomes: shorter procedural (55 ± 29 min vs. 81 ± 39 min, p = 0.04) and fluoroscopic times (27 ± 11 min vs. 37 ± 17 min, p = 0.045) and a tendency toward a lower 1-year AF recurrence rate (39 vs. 12 %, p = 0.09).

Conclusions

The beneficial effects of using steerable sheaths were more prominent in patients with severe LA enlargement.
Literature
1.
go back to reference Rajappan K, Baker V, Richmond L, Kistler PM, Thomas G, Redpath C, et al. A randomized trial to compare atrial fibrillation ablation using a steerable vs. a non-steerable sheath. Europace. 2009;11:571–5.CrossRefPubMed Rajappan K, Baker V, Richmond L, Kistler PM, Thomas G, Redpath C, et al. A randomized trial to compare atrial fibrillation ablation using a steerable vs. a non-steerable sheath. Europace. 2009;11:571–5.CrossRefPubMed
2.
go back to reference Piorkowski C, Eitel C, Rolf S, Bode K, Sommer P, Gaspar T, et al. Steerable versus nonsteerable sheath technology in atrial fibrillation ablation: a prospective, randomized study. Circ Arrhythm Electrophysiol. 2011;4:157–65.CrossRefPubMed Piorkowski C, Eitel C, Rolf S, Bode K, Sommer P, Gaspar T, et al. Steerable versus nonsteerable sheath technology in atrial fibrillation ablation: a prospective, randomized study. Circ Arrhythm Electrophysiol. 2011;4:157–65.CrossRefPubMed
3.
go back to reference Yokoyama K, Nakagawa H, Shah DC, Lambert H, Leo G, Aeby N, et al. Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus. Circ Arrhythm Electrophysiol. 2008;1:354–62.CrossRefPubMed Yokoyama K, Nakagawa H, Shah DC, Lambert H, Leo G, Aeby N, et al. Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus. Circ Arrhythm Electrophysiol. 2008;1:354–62.CrossRefPubMed
4.
go back to reference Reddy VY, Shah D, Kautzner J, Schmidt B, Saoudi N, Herrera C, et al. The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. Heart Rhythm. 2012;9:1789–95.CrossRefPubMed Reddy VY, Shah D, Kautzner J, Schmidt B, Saoudi N, Herrera C, et al. The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. Heart Rhythm. 2012;9:1789–95.CrossRefPubMed
5.
go back to reference Andrade JG, Monir G, Pollak SJ, Khairy P, Dubuc M, Roy D, et al. Pulmonary vein isolation using “contact force” ablation: the effect on dormant conduction and long-term freedom from recurrent atrial fibrillation—a prospective study. Heart Rhythm. 2014;11:1919–24.CrossRefPubMed Andrade JG, Monir G, Pollak SJ, Khairy P, Dubuc M, Roy D, et al. Pulmonary vein isolation using “contact force” ablation: the effect on dormant conduction and long-term freedom from recurrent atrial fibrillation—a prospective study. Heart Rhythm. 2014;11:1919–24.CrossRefPubMed
6.
go back to reference Neuzil P, Reddy VY, Kautzner J, Petru J, Wichterle D, Shah D, et al. Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study. Circ Arrhythm Electrophysiol. 2013;6:327–33.CrossRefPubMed Neuzil P, Reddy VY, Kautzner J, Petru J, Wichterle D, Shah D, et al. Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study. Circ Arrhythm Electrophysiol. 2013;6:327–33.CrossRefPubMed
7.
go back to reference Kimura T, Takatsuki S, Oishi A, Negishi M, Kashimura S, Katsumata Y, et al. Operator-blinded contact force monitoring during pulmonary vein isolation using conventional and steerable sheaths. Int J Cardiol. 2014;177:970–6.CrossRefPubMed Kimura T, Takatsuki S, Oishi A, Negishi M, Kashimura S, Katsumata Y, et al. Operator-blinded contact force monitoring during pulmonary vein isolation using conventional and steerable sheaths. Int J Cardiol. 2014;177:970–6.CrossRefPubMed
8.
go back to reference Ullah W, Hunter RJ, McLean A, Dhinoja M, Earley MJ, Sporton S, et al. Impact of steerable sheaths on contact forces and reconnection sites in ablation for persistent atrial fibrillation. J Cardiovasc Electrophysiol. 2015;26:266–73.CrossRefPubMed Ullah W, Hunter RJ, McLean A, Dhinoja M, Earley MJ, Sporton S, et al. Impact of steerable sheaths on contact forces and reconnection sites in ablation for persistent atrial fibrillation. J Cardiovasc Electrophysiol. 2015;26:266–73.CrossRefPubMed
9.
go back to reference Sotomi Y, Kikkawa T, Inoue K, Tanaka K, Toyoshima Y, Oka T, et al. Regional difference of optimal contact force to prevent acute pulmonary vein reconnection during radiofrequency catheter ablation for atrial fibrillation. J Cardiovasc Electrophysiol. 2014;25:941–7.CrossRefPubMed Sotomi Y, Kikkawa T, Inoue K, Tanaka K, Toyoshima Y, Oka T, et al. Regional difference of optimal contact force to prevent acute pulmonary vein reconnection during radiofrequency catheter ablation for atrial fibrillation. J Cardiovasc Electrophysiol. 2014;25:941–7.CrossRefPubMed
10.
go back to reference Kumar S, Morton JB, Lee J, Halloran K, Spence SJ, Gorelik A, et al. Prospective characterization of catheter-tissue contact force at different anatomic sites during antral pulmonary vein isolation. Circ Arrhythm Electrophysiol. 2012;5:1124–9.CrossRefPubMed Kumar S, Morton JB, Lee J, Halloran K, Spence SJ, Gorelik A, et al. Prospective characterization of catheter-tissue contact force at different anatomic sites during antral pulmonary vein isolation. Circ Arrhythm Electrophysiol. 2012;5:1124–9.CrossRefPubMed
11.
go back to reference Hof I, Chilukuri K, Arbab-Zadeh A, Scherr D, Dalal D, Nazarian S, et al. Does left atrial volume and pulmonary venous anatomy predict the outcome of catheter ablation of atrial fibrillation? J Cardiovasc Electrophysiol. 2009;20:1005–10.CrossRefPubMed Hof I, Chilukuri K, Arbab-Zadeh A, Scherr D, Dalal D, Nazarian S, et al. Does left atrial volume and pulmonary venous anatomy predict the outcome of catheter ablation of atrial fibrillation? J Cardiovasc Electrophysiol. 2009;20:1005–10.CrossRefPubMed
12.
go back to reference Abecasis J, Dourado R, Ferreira A, Saraiva C, Cavaco D, Santos KR, et al. Left atrial volume calculated by multi-detector computed tomography may predict successful pulmonary vein isolation in catheter ablation of atrial fibrillation. Europace. 2009;11:1289–94.CrossRefPubMed Abecasis J, Dourado R, Ferreira A, Saraiva C, Cavaco D, Santos KR, et al. Left atrial volume calculated by multi-detector computed tomography may predict successful pulmonary vein isolation in catheter ablation of atrial fibrillation. Europace. 2009;11:1289–94.CrossRefPubMed
13.
go back to reference Schluermann F, Krauss T, Biermann J, Hartmann M, Trolese L, Pache G, et al. In vivo contact force measurements and correlation with left atrial anatomy during catheter ablation of atrial fibrillation. Europace. 2015;17:1526–32.CrossRefPubMed Schluermann F, Krauss T, Biermann J, Hartmann M, Trolese L, Pache G, et al. In vivo contact force measurements and correlation with left atrial anatomy during catheter ablation of atrial fibrillation. Europace. 2015;17:1526–32.CrossRefPubMed
14.
go back to reference le Polain de Waroux JB, Weerasooriya R, Anvardeen K, Barbraud C, Marchandise S, De Meester C, et al. Low contact force and force-time integral predict early recovery and dormant conduction revealed by adenosine after pulmonary vein isolation. Europace. 2015;17:877–83.CrossRef le Polain de Waroux JB, Weerasooriya R, Anvardeen K, Barbraud C, Marchandise S, De Meester C, et al. Low contact force and force-time integral predict early recovery and dormant conduction revealed by adenosine after pulmonary vein isolation. Europace. 2015;17:877–83.CrossRef
15.
go back to reference Kautzner J, Neuzil P, Lambert H, Peichl P, Petru J, Cihak R, et al. EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation. Europace. 2015;17:1229–35.CrossRefPubMedPubMedCentral Kautzner J, Neuzil P, Lambert H, Peichl P, Petru J, Cihak R, et al. EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation. Europace. 2015;17:1229–35.CrossRefPubMedPubMedCentral
Metadata
Title
Steerable versus non-steerable sheaths during pulmonary vein isolation: impact of left atrial enlargement on the catheter–tissue contact force
Authors
Masaharu Masuda
Masashi Fujita
Osamu Iida
Shin Okamoto
Takayuki Ishihara
Kiyonori Nanto
Takashi Kanda
Tatsuya Shiraki
Akihiro Sunaga
Yasuhiro Matsuda
Masaaki Uematsu
Publication date
01-10-2016
Publisher
Springer US
Published in
Journal of Interventional Cardiac Electrophysiology / Issue 1/2016
Print ISSN: 1383-875X
Electronic ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-016-0135-4

Other articles of this Issue 1/2016

Journal of Interventional Cardiac Electrophysiology 1/2016 Go to the issue