Abstract

Objective

Remote magnetic navigation (RMN) is considered to be a solution for mapping and ablation of several arrhythmias. In this systematic review we aimed to assess the safety and efficacy of RMN in ablation of ventricular tachycardia (VT).

Methods

The National Library of Medicine’s PubMed database was searched for articles containing any of a predetermined set of search terms that were published prior to November 1, 2011. Quality of evidence was rated using the GRADE system.

Results

The database search resulted in 11 relevant articles evaluating the usefulness of RMN. Three groups of VTs were studied: VT in patients with ischemic cardiomyopathy (ICMP), non-ischemic cardiomyopathy (NICMP) and structurally normal hearts (SNH). The use of RMN in patients with ICMP has been associated with success rates ranging from 71 to 80%. RMN has been shown to be a feasible and effective method for ablation of VT in NICMP and SNH patients. Success rates between 50% and 100% have been reported in NICMP populations. Rates ranging from 86% to 100% have been reported for SNH patients. The lowest rates of arrhythmia recurrence are reported for SNH patients (0–17%). In ICMP and NICMP, recurrence rates of 0–30% and 14–50%, respectively, have been reported. One patient experienced total heart block, and one patient experienced a thromboembolic event after RMN catheter ablation procedures.

Conclusions

RMN has been shown to be an effective and safe method for ablation of VT in various patient populations with low recurrence and complication rates. However, more comparative and randomized studies are necessary, and therefore the true value of RMN for VT ablation remains still unknown.
Literature
1.
go back to reference Reddy, V. Y., Reynolds, M. R., Neuzil, P., Richardson, A. W., Taborsky, M., Jongnarangsin, K., Kralovec, S., Sediva, L., Ruskin, J. N., & Josephson, M. E. (2007). Prophylactic catheter ablation for the prevention of defibrillator therapy. The New England Journal of Medicine, 357, 2657–2665.PubMedCrossRef Reddy, V. Y., Reynolds, M. R., Neuzil, P., Richardson, A. W., Taborsky, M., Jongnarangsin, K., Kralovec, S., Sediva, L., Ruskin, J. N., & Josephson, M. E. (2007). Prophylactic catheter ablation for the prevention of defibrillator therapy. The New England Journal of Medicine, 357, 2657–2665.PubMedCrossRef
2.
go back to reference Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., Myerburg, R. J., Priori, S. G., Quinones, M. A., Roden, D. M., Silka, M. J., Tracy, C., Smith, S. C., Jr., Jacobs, A. K., Adams, C. D., Antman, E. M., Anderson, J. L., Hunt, S. A., Halperin, J. L., Nishimura, R., Ornato, J. P., Page, R. L., Riegel, B., Blanc, J. J., Budaj, A., Dean, V., Deckers, J. W., Despres, C., Dickstein, K., Lekakis, J., McGregor, K., Metra, M., Morais, J., Osterspey, A., Tamargo, J. L., & Zamorano, J. L. (2006). Acc/aha/esc 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: a report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for practice guidelines (writing committee to develop guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death): developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society. Circulation, 114, e385–484.PubMedCrossRef Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., Myerburg, R. J., Priori, S. G., Quinones, M. A., Roden, D. M., Silka, M. J., Tracy, C., Smith, S. C., Jr., Jacobs, A. K., Adams, C. D., Antman, E. M., Anderson, J. L., Hunt, S. A., Halperin, J. L., Nishimura, R., Ornato, J. P., Page, R. L., Riegel, B., Blanc, J. J., Budaj, A., Dean, V., Deckers, J. W., Despres, C., Dickstein, K., Lekakis, J., McGregor, K., Metra, M., Morais, J., Osterspey, A., Tamargo, J. L., & Zamorano, J. L. (2006). Acc/aha/esc 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: a report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for practice guidelines (writing committee to develop guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death): developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society. Circulation, 114, e385–484.PubMedCrossRef
3.
go back to reference Carbucicchio, C., Santamaria, M., Trevisi, N., Maccabelli, G., Giraldi, F., Fassini, G., Riva, S., Moltrasio, M., Cireddu, M., Veglia, F., & Della Bella, P. (2008). Catheter ablation for the treatment of electrical storm in patients with implantable cardioverter-defibrillators: short- and long-term outcomes in a prospective single-center study. Circulation, 117, 462–469.PubMedCrossRef Carbucicchio, C., Santamaria, M., Trevisi, N., Maccabelli, G., Giraldi, F., Fassini, G., Riva, S., Moltrasio, M., Cireddu, M., Veglia, F., & Della Bella, P. (2008). Catheter ablation for the treatment of electrical storm in patients with implantable cardioverter-defibrillators: short- and long-term outcomes in a prospective single-center study. Circulation, 117, 462–469.PubMedCrossRef
4.
go back to reference Bansch, D., Oyang, F., Antz, M., Arentz, T., Weber, R., Val-Mejias, J. E., Ernst, S., & Kuck, K. H. (2003). Successful catheter ablation of electrical storm after myocardial infarction. Circulation, 108, 3011–3016.PubMedCrossRef Bansch, D., Oyang, F., Antz, M., Arentz, T., Weber, R., Val-Mejias, J. E., Ernst, S., & Kuck, K. H. (2003). Successful catheter ablation of electrical storm after myocardial infarction. Circulation, 108, 3011–3016.PubMedCrossRef
5.
go back to reference Borger van der Burg, A. E., de Groot, N. M., van Erven, L., Bootsma, M., van der Wall, E. E., & Schalij, M. J. (2002). Long-term follow-up after radiofrequency catheter ablation of ventricular tachycardia: a successful approach? Journal of Cardiovascular Electrophysiology, 13, 417–423.PubMedCrossRef Borger van der Burg, A. E., de Groot, N. M., van Erven, L., Bootsma, M., van der Wall, E. E., & Schalij, M. J. (2002). Long-term follow-up after radiofrequency catheter ablation of ventricular tachycardia: a successful approach? Journal of Cardiovascular Electrophysiology, 13, 417–423.PubMedCrossRef
6.
go back to reference Aryana, A., d’Avila, A., Heist, E. K., Mela, T., Singh, J. P., Ruskin, J. N., & Reddy, V. Y. (2007). Remote magnetic navigation to guide endocardial and epicardial catheter mapping of scar-related ventricular tachycardia. Circulation, 115, 1191–1200.PubMed Aryana, A., d’Avila, A., Heist, E. K., Mela, T., Singh, J. P., Ruskin, J. N., & Reddy, V. Y. (2007). Remote magnetic navigation to guide endocardial and epicardial catheter mapping of scar-related ventricular tachycardia. Circulation, 115, 1191–1200.PubMed
7.
go back to reference Burkhardt, J. D., Saliba, W. I., Schweikert, R. A., Cummings, J., & Natale, A. (2006). Remote magnetic navigation to map and ablate left coronary cusp ventricular tachycardia. Journal of Cardiovascular Electrophysiology, 17, 1142–1144.PubMedCrossRef Burkhardt, J. D., Saliba, W. I., Schweikert, R. A., Cummings, J., & Natale, A. (2006). Remote magnetic navigation to map and ablate left coronary cusp ventricular tachycardia. Journal of Cardiovascular Electrophysiology, 17, 1142–1144.PubMedCrossRef
8.
go back to reference Di Biase, L., Fahmy, T. S., Patel, D., Bai, R., Civello, K., Wazni, O. M., Kanj, M., Elayi, C. S., Ching, C. K., Khan, M., Popova, L., Schweikert, R. A., Cummings, J. E., Burkhardt, J. D., Martin, D. O., Bhargava, M., Dresing, T., Saliba, W., Arruda, M., & Natale, A. (2007). Remote magnetic navigation: human experience in pulmonary vein ablation. Journal of the American College of Cardiology, 50, 868–874.PubMedCrossRef Di Biase, L., Fahmy, T. S., Patel, D., Bai, R., Civello, K., Wazni, O. M., Kanj, M., Elayi, C. S., Ching, C. K., Khan, M., Popova, L., Schweikert, R. A., Cummings, J. E., Burkhardt, J. D., Martin, D. O., Bhargava, M., Dresing, T., Saliba, W., Arruda, M., & Natale, A. (2007). Remote magnetic navigation: human experience in pulmonary vein ablation. Journal of the American College of Cardiology, 50, 868–874.PubMedCrossRef
9.
go back to reference Pflaumer, A., Hessling, G., Luik, A., Wu, J., & Zrenner, B. (2007). Remote magnetic catheter mapping and ablation of permanent junctional reciprocating tachycardia in a seven-year-old child. Journal of Cardiovascular Electrophysiology, 18, 882–885.PubMedCrossRef Pflaumer, A., Hessling, G., Luik, A., Wu, J., & Zrenner, B. (2007). Remote magnetic catheter mapping and ablation of permanent junctional reciprocating tachycardia in a seven-year-old child. Journal of Cardiovascular Electrophysiology, 18, 882–885.PubMedCrossRef
10.
go back to reference Davis, D. R., Tang, A. S., Gollob, M. H., Lemery, R., Green, M. S., & Birnie, D. H. (2008). Remote magnetic navigation-assisted catheter ablation enhances catheter stability and ablation success with lower catheter temperatures. Pacing and Clinical Electrophysiology, 31, 893–898.PubMedCrossRef Davis, D. R., Tang, A. S., Gollob, M. H., Lemery, R., Green, M. S., & Birnie, D. H. (2008). Remote magnetic navigation-assisted catheter ablation enhances catheter stability and ablation success with lower catheter temperatures. Pacing and Clinical Electrophysiology, 31, 893–898.PubMedCrossRef
11.
go back to reference Schwagten, B. K., Szili-Torok, T., Rivero-Ayerza, M., Jessurun, E., Valk, S., & Jordaens, L. J. (2009). Usefulness of remote magnetic navigation for ablation of ventricular arrhythmias originating from outflow regions. Netherlands Heart Journal, 17, 245–249.PubMedCrossRef Schwagten, B. K., Szili-Torok, T., Rivero-Ayerza, M., Jessurun, E., Valk, S., & Jordaens, L. J. (2009). Usefulness of remote magnetic navigation for ablation of ventricular arrhythmias originating from outflow regions. Netherlands Heart Journal, 17, 245–249.PubMedCrossRef
12.
go back to reference Ernst, S. (2008). Magnetic and robotic navigation for catheter ablation: “joystick ablation”. Journal of Interventional Cardiac Electrophysiology, 23, 41–44.PubMedCrossRef Ernst, S. (2008). Magnetic and robotic navigation for catheter ablation: “joystick ablation”. Journal of Interventional Cardiac Electrophysiology, 23, 41–44.PubMedCrossRef
13.
go back to reference Bauernfeind, T., Akca, F., Schwagten, B., de Groot, N., Van Belle, Y., Valk, S., Ujvari, B., Jordaens, L., & Szili-Torok, T. (2011). The magnetic navigation system allows safety and high efficacy for ablation of arrhythmias. Europace, 13, 1015–1021.PubMedCrossRef Bauernfeind, T., Akca, F., Schwagten, B., de Groot, N., Van Belle, Y., Valk, S., Ujvari, B., Jordaens, L., & Szili-Torok, T. (2011). The magnetic navigation system allows safety and high efficacy for ablation of arrhythmias. Europace, 13, 1015–1021.PubMedCrossRef
14.
go back to reference Xu, D., Yang, B., Shan, Q., Zou, J., Chen, M., Chen, C., Hou, X., Zhang, F., Li, W. Q., Cao, K., & Tse, H. F. (2009). Initial clinical experience of remote magnetic navigation system for catheter mapping and ablation of supraventricular tachycardias. Journal of Interventional Cardiac Electrophysiology, 25, 171–174.PubMedCrossRef Xu, D., Yang, B., Shan, Q., Zou, J., Chen, M., Chen, C., Hou, X., Zhang, F., Li, W. Q., Cao, K., & Tse, H. F. (2009). Initial clinical experience of remote magnetic navigation system for catheter mapping and ablation of supraventricular tachycardias. Journal of Interventional Cardiac Electrophysiology, 25, 171–174.PubMedCrossRef
15.
go back to reference Luthje L, Vollmann D, Seegers J, Dorenkamp M, Sohns C, Hasenfuss G, Zabel M. Remote magnetic versus manual catheter navigation for circumferential pulmonary vein ablation in patients with atrial fibrillation. Clin Res Cardiol 2011. Luthje L, Vollmann D, Seegers J, Dorenkamp M, Sohns C, Hasenfuss G, Zabel M. Remote magnetic versus manual catheter navigation for circumferential pulmonary vein ablation in patients with atrial fibrillation. Clin Res Cardiol 2011.
16.
go back to reference Schwagten, B., Witsenburg, M., De Groot, N. M., Jordaens, L., & Szili-Torok, T. (2010). Effect of magnetic navigation system on procedure times and radiation risk in children undergoing catheter ablation. The American Journal of Cardiology, 106, 69–72.PubMedCrossRef Schwagten, B., Witsenburg, M., De Groot, N. M., Jordaens, L., & Szili-Torok, T. (2010). Effect of magnetic navigation system on procedure times and radiation risk in children undergoing catheter ablation. The American Journal of Cardiology, 106, 69–72.PubMedCrossRef
17.
go back to reference Ernst, S., Hachiya, H., Chun, J. K., & Ouyang, F. (2005). Remote catheter ablation of parahisian accessory pathways using a novel magnetic navigation system—a report of two cases. Journal of Cardiovascular Electrophysiology, 16, 659–662.PubMedCrossRef Ernst, S., Hachiya, H., Chun, J. K., & Ouyang, F. (2005). Remote catheter ablation of parahisian accessory pathways using a novel magnetic navigation system—a report of two cases. Journal of Cardiovascular Electrophysiology, 16, 659–662.PubMedCrossRef
18.
go back to reference Ernst, S., Ouyang, F., Linder, C., Hertting, K., Stahl, F., Chun, J., Hachiya, H., Krumsdorf, U., Antz, M., & Kuck, K. H. (2004). Modulation of the slow pathway in the presence of a persistent left superior caval vein using the novel magnetic navigation system niobe. Europace, 6, 10–14.PubMedCrossRef Ernst, S., Ouyang, F., Linder, C., Hertting, K., Stahl, F., Chun, J., Hachiya, H., Krumsdorf, U., Antz, M., & Kuck, K. H. (2004). Modulation of the slow pathway in the presence of a persistent left superior caval vein using the novel magnetic navigation system niobe. Europace, 6, 10–14.PubMedCrossRef
19.
go back to reference Pappone, C., Vicedomini, G., Manguso, F., Gugliotta, F., Mazzone, P., Gulletta, S., Sora, N., Sala, S., Marzi, A., Augello, G., Livolsi, L., Santagostino, A., & Santinelli, V. (2006). Robotic magnetic navigation for atrial fibrillation ablation. Journal of the American College of Cardiology, 47, 1390–1400.PubMedCrossRef Pappone, C., Vicedomini, G., Manguso, F., Gugliotta, F., Mazzone, P., Gulletta, S., Sora, N., Sala, S., Marzi, A., Augello, G., Livolsi, L., Santagostino, A., & Santinelli, V. (2006). Robotic magnetic navigation for atrial fibrillation ablation. Journal of the American College of Cardiology, 47, 1390–1400.PubMedCrossRef
20.
go back to reference Haghjoo, M., Hindricks, G., Bode, K., Piorkowski, C., Bollmann, A., & Arya, A. (2009). Initial clinical experience with the new irrigated tip magnetic catheter for ablation of scar-related sustained ventricular tachycardia: a small case series. Journal of Cardiovascular Electrophysiology, 20, 935–939.PubMedCrossRef Haghjoo, M., Hindricks, G., Bode, K., Piorkowski, C., Bollmann, A., & Arya, A. (2009). Initial clinical experience with the new irrigated tip magnetic catheter for ablation of scar-related sustained ventricular tachycardia: a small case series. Journal of Cardiovascular Electrophysiology, 20, 935–939.PubMedCrossRef
21.
go back to reference Latcu, D. G., Ricard, P., Zarqane, N., Yaici, K., Rinaldi, J. P., Maluski, A., & Saoudi, N. (2009). Robotic magnetic navigation for ablation of human arrhythmias: initial experience. Archives of Cardiovascular Diseases, 102, 419–425.PubMedCrossRef Latcu, D. G., Ricard, P., Zarqane, N., Yaici, K., Rinaldi, J. P., Maluski, A., & Saoudi, N. (2009). Robotic magnetic navigation for ablation of human arrhythmias: initial experience. Archives of Cardiovascular Diseases, 102, 419–425.PubMedCrossRef
22.
go back to reference Di Biase, L., Santangeli, P., Astudillo, V., Conti, S., Mohanty, P., Mohanty, S., Sanchez, J. E., Horton, R., Thomas, B., Burkhardt, J. D., & Natale, A. (2010). Endo-epicardial ablation of ventricular arrhythmias in the left ventricle with the remote magnetic navigation system and the 3.5-mm open irrigated magnetic catheter: results from a large single-center case–control series. Heart Rhythm, 7, 1029–1035.PubMedCrossRef Di Biase, L., Santangeli, P., Astudillo, V., Conti, S., Mohanty, P., Mohanty, S., Sanchez, J. E., Horton, R., Thomas, B., Burkhardt, J. D., & Natale, A. (2010). Endo-epicardial ablation of ventricular arrhythmias in the left ventricle with the remote magnetic navigation system and the 3.5-mm open irrigated magnetic catheter: results from a large single-center case–control series. Heart Rhythm, 7, 1029–1035.PubMedCrossRef
23.
go back to reference Schreiber, D., & Kottkamp, H. (2010). Ablation of idiopathic ventricular tachycardia. Current Cardiology Reports, 12, 382–388.PubMedCrossRef Schreiber, D., & Kottkamp, H. (2010). Ablation of idiopathic ventricular tachycardia. Current Cardiology Reports, 12, 382–388.PubMedCrossRef
24.
go back to reference Kamakura, S., Shimizu, W., Matsuo, K., Taguchi, A., Suyama, K., Kurita, T., Aihara, N., Ohe, T., & Shimomura, K. (1998). Localization of optimal ablation site of idiopathic ventricular tachycardia from right and left ventricular outflow tract by body surface ECG. Circulation, 98, 1525–1533.PubMed Kamakura, S., Shimizu, W., Matsuo, K., Taguchi, A., Suyama, K., Kurita, T., Aihara, N., Ohe, T., & Shimomura, K. (1998). Localization of optimal ablation site of idiopathic ventricular tachycardia from right and left ventricular outflow tract by body surface ECG. Circulation, 98, 1525–1533.PubMed
25.
go back to reference Krebs, M. E., Krause, P. C., Engelstein, E. D., Zipes, D. P., & Miles, W. M. (2000). Ventricular tachycardias mimicking those arising from the right ventricular outflow tract. Journal of Cardiovascular Electrophysiology, 11, 45–51.PubMedCrossRef Krebs, M. E., Krause, P. C., Engelstein, E. D., Zipes, D. P., & Miles, W. M. (2000). Ventricular tachycardias mimicking those arising from the right ventricular outflow tract. Journal of Cardiovascular Electrophysiology, 11, 45–51.PubMedCrossRef
26.
go back to reference Timmermans, C., Rodriguez, L. M., Crijns, H. J., Moorman, A. F., & Wellens, H. J. (2003). Idiopathic left bundle-branch block-shaped ventricular tachycardia may originate above the pulmonary valve. Circulation, 108, 1960–1967.PubMedCrossRef Timmermans, C., Rodriguez, L. M., Crijns, H. J., Moorman, A. F., & Wellens, H. J. (2003). Idiopathic left bundle-branch block-shaped ventricular tachycardia may originate above the pulmonary valve. Circulation, 108, 1960–1967.PubMedCrossRef
27.
go back to reference Guyatt, G. H., Oxman, A. D., Vist, G. E., Kunz, R., Falck-Ytter, Y., Alonso-Coello, P., Schunemann, H. J., & Group, G. W. (2008). Grade: an emerging consensus on rating quality of evidence and strength of recommendations. BMJ, 336, 924–926.PubMedCrossRef Guyatt, G. H., Oxman, A. D., Vist, G. E., Kunz, R., Falck-Ytter, Y., Alonso-Coello, P., Schunemann, H. J., & Group, G. W. (2008). Grade: an emerging consensus on rating quality of evidence and strength of recommendations. BMJ, 336, 924–926.PubMedCrossRef
28.
go back to reference Perez-David, E., Arenal, A., Rubio-Guivernau, J. L., del Castillo, R., Atea, L., Arbelo, E., Caballero, E., Celorrio, V., Datino, T., Gonzalez-Torrecilla, E., Atienza, F., Ledesma-Carbayo, M. J., Bermejo, J., Medina, A., & Fernandez-Aviles, F. (2011). Noninvasive identification of ventricular tachycardia-related conducting channels using contrast-enhanced magnetic resonance imaging in patients with chronic myocardial infarction: comparison of signal intensity scar mapping and endocardial voltage mapping. Journal of the American College of Cardiology, 57, 184–194.PubMedCrossRef Perez-David, E., Arenal, A., Rubio-Guivernau, J. L., del Castillo, R., Atea, L., Arbelo, E., Caballero, E., Celorrio, V., Datino, T., Gonzalez-Torrecilla, E., Atienza, F., Ledesma-Carbayo, M. J., Bermejo, J., Medina, A., & Fernandez-Aviles, F. (2011). Noninvasive identification of ventricular tachycardia-related conducting channels using contrast-enhanced magnetic resonance imaging in patients with chronic myocardial infarction: comparison of signal intensity scar mapping and endocardial voltage mapping. Journal of the American College of Cardiology, 57, 184–194.PubMedCrossRef
29.
go back to reference Luthje, L., Vollmann, D., Seegers, J., Sohns, C., Hasenfuss, G., & Zabel, M. (2010). Interference of remote magnetic catheter navigation and ablation with implanted devices for pacing and defibrillation. Europace, 12, 1574–1580.PubMedCrossRef Luthje, L., Vollmann, D., Seegers, J., Sohns, C., Hasenfuss, G., & Zabel, M. (2010). Interference of remote magnetic catheter navigation and ablation with implanted devices for pacing and defibrillation. Europace, 12, 1574–1580.PubMedCrossRef
30.
go back to reference Eitel, C., Hindricks, G., Sommer, P., Wetzel, U., Bollmann, A., Gaspar, T., Piorkowski, C., & Arya, A. (2010). Safety of remote magnetic navigation in patients with pacemakers and implanted cardioverter defibrillators. Journal of Cardiovascular Electrophysiology, 21, 1130–1135.PubMedCrossRef Eitel, C., Hindricks, G., Sommer, P., Wetzel, U., Bollmann, A., Gaspar, T., Piorkowski, C., & Arya, A. (2010). Safety of remote magnetic navigation in patients with pacemakers and implanted cardioverter defibrillators. Journal of Cardiovascular Electrophysiology, 21, 1130–1135.PubMedCrossRef
31.
go back to reference Sarrazin, J. F., Labounty, T., Kuhne, M., Crawford, T., Armstrong, W. F., Desjardins, B., Good, E., Jongnarangsin, K., Chugh, A., Oral, H., Pelosi, F., Morady, F., & Bogun, F. (2009). Impact of radiofrequency ablation of frequent post-infarction premature ventricular complexes on left ventricular ejection fraction. Heart Rhythm, 6, 1543–1549.PubMedCrossRef Sarrazin, J. F., Labounty, T., Kuhne, M., Crawford, T., Armstrong, W. F., Desjardins, B., Good, E., Jongnarangsin, K., Chugh, A., Oral, H., Pelosi, F., Morady, F., & Bogun, F. (2009). Impact of radiofrequency ablation of frequent post-infarction premature ventricular complexes on left ventricular ejection fraction. Heart Rhythm, 6, 1543–1549.PubMedCrossRef
32.
go back to reference Katsiyiannis, W. T., Melby, D. P., Matelski, J. L., Ervin, V. L., Laverence, K. L., & Gornick, C. C. (2008). Feasibility and safety of remote-controlled magnetic navigation for ablation of atrial fibrillation. The American Journal of Cardiology, 102, 1674–1676.PubMedCrossRef Katsiyiannis, W. T., Melby, D. P., Matelski, J. L., Ervin, V. L., Laverence, K. L., & Gornick, C. C. (2008). Feasibility and safety of remote-controlled magnetic navigation for ablation of atrial fibrillation. The American Journal of Cardiology, 102, 1674–1676.PubMedCrossRef
33.
go back to reference Arya, A., Kottkamp, H., Piorkowski, C., Bollmann, A., Gerdes-Li, J. H., Riahi, S., Esato, M., & Hindricks, G. (2008). Initial clinical experience with a remote magnetic catheter navigation system for ablation of cavotricuspid isthmus-dependent right atrial flutter. Pacing and Clinical Electrophysiology, 31, 597–603.PubMedCrossRef Arya, A., Kottkamp, H., Piorkowski, C., Bollmann, A., Gerdes-Li, J. H., Riahi, S., Esato, M., & Hindricks, G. (2008). Initial clinical experience with a remote magnetic catheter navigation system for ablation of cavotricuspid isthmus-dependent right atrial flutter. Pacing and Clinical Electrophysiology, 31, 597–603.PubMedCrossRef
34.
go back to reference Ray, I. B., Dukkipati, S., Houghtaling, C., McPherson, C. D., Kastelein, N., Ruskin, J. N., & Reddy, V. Y. (2007). Initial experience with a novel remote-guided magnetic catheter navigation system for left ventricular scar mapping and ablation in a porcine model of healed myocardial infarction. Journal of Cardiovascular Electrophysiology, 18, 520–525.PubMedCrossRef Ray, I. B., Dukkipati, S., Houghtaling, C., McPherson, C. D., Kastelein, N., Ruskin, J. N., & Reddy, V. Y. (2007). Initial experience with a novel remote-guided magnetic catheter navigation system for left ventricular scar mapping and ablation in a porcine model of healed myocardial infarction. Journal of Cardiovascular Electrophysiology, 18, 520–525.PubMedCrossRef
35.
go back to reference Thornton, A. S., Rivero-Ayerza, M., Knops, P., & Jordaens, L. J. (2007). Magnetic navigation in left-sided AV reentrant tachycardias: preliminary results of a retrograde approach. Journal of Cardiovascular Electrophysiology, 18, 467–472.PubMedCrossRef Thornton, A. S., Rivero-Ayerza, M., Knops, P., & Jordaens, L. J. (2007). Magnetic navigation in left-sided AV reentrant tachycardias: preliminary results of a retrograde approach. Journal of Cardiovascular Electrophysiology, 18, 467–472.PubMedCrossRef
36.
go back to reference van Dockum, W. G., Kuijer, J. P., Gotte, M. J., Ten Cate, F. J., Ten Berg, J. M., Beek, A. M., Twisk, J. W., Marcus, J. T., Visser, C. A., & van Rossum, A. C. (2006). Septal ablation in hypertrophic obstructive cardiomyopathy improves systolic myocardial function in the lateral (free) wall: a follow-up study using CMR tissue tagging and 3D strain analysis. European Heart Journal, 27, 2833–2839.PubMedCrossRef van Dockum, W. G., Kuijer, J. P., Gotte, M. J., Ten Cate, F. J., Ten Berg, J. M., Beek, A. M., Twisk, J. W., Marcus, J. T., Visser, C. A., & van Rossum, A. C. (2006). Septal ablation in hypertrophic obstructive cardiomyopathy improves systolic myocardial function in the lateral (free) wall: a follow-up study using CMR tissue tagging and 3D strain analysis. European Heart Journal, 27, 2833–2839.PubMedCrossRef
37.
go back to reference van Dockum, W. G., Beek, A. M., ten Cate, F. J., ten Berg, J. M., Bondarenko, O., Gotte, M. J., Twisk, J. W., Hofman, M. B., Visser, C. A., & van Rossum, A. C. (2005). Early onset and progression of left ventricular remodeling after alcohol septal ablation in hypertrophic obstructive cardiomyopathy. Circulation, 111, 2503–2508.PubMedCrossRef van Dockum, W. G., Beek, A. M., ten Cate, F. J., ten Berg, J. M., Bondarenko, O., Gotte, M. J., Twisk, J. W., Hofman, M. B., Visser, C. A., & van Rossum, A. C. (2005). Early onset and progression of left ventricular remodeling after alcohol septal ablation in hypertrophic obstructive cardiomyopathy. Circulation, 111, 2503–2508.PubMedCrossRef
38.
go back to reference Di Biase, L., Burkhardt, J. D., Lakkireddy, D., Pillarisetti, J., Baryun, E. N., Biria, M., Horton, R., Sanchez, J., Gallinghouse, G. J., Bailey, S., Beheiry, S., Hongo, R., Hao, S., Tomassoni, G., & Natale, A. (2009). Mapping and ablation of ventricular arrhythmias with magnetic navigation: comparison between 4- and 8-mm catheter tips. Journal of Interventional Cardiac Electrophysiology, 26, 133–137.PubMedCrossRef Di Biase, L., Burkhardt, J. D., Lakkireddy, D., Pillarisetti, J., Baryun, E. N., Biria, M., Horton, R., Sanchez, J., Gallinghouse, G. J., Bailey, S., Beheiry, S., Hongo, R., Hao, S., Tomassoni, G., & Natale, A. (2009). Mapping and ablation of ventricular arrhythmias with magnetic navigation: comparison between 4- and 8-mm catheter tips. Journal of Interventional Cardiac Electrophysiology, 26, 133–137.PubMedCrossRef
39.
go back to reference Arya, A., Eitel, C., Bollmann, A., Wetzel, U., Sommer, P., Gaspar, T., Husser, D., Piorkowski, C., & Hindricks, G. (2010). Catheter ablation of scar-related ventricular tachycardia in patients with electrical storm using remote magnetic catheter navigation. Pacing and Clinical Electrophysiology, 33, 1312–1318.PubMedCrossRef Arya, A., Eitel, C., Bollmann, A., Wetzel, U., Sommer, P., Gaspar, T., Husser, D., Piorkowski, C., & Hindricks, G. (2010). Catheter ablation of scar-related ventricular tachycardia in patients with electrical storm using remote magnetic catheter navigation. Pacing and Clinical Electrophysiology, 33, 1312–1318.PubMedCrossRef
40.
go back to reference Thornton, A. S., & Jordaens, L. J. (2006). Remote magnetic navigation for mapping and ablating right ventricular outflow tract tachycardia. Heart Rhythm, 3, 691–696.PubMedCrossRef Thornton, A. S., & Jordaens, L. J. (2006). Remote magnetic navigation for mapping and ablating right ventricular outflow tract tachycardia. Heart Rhythm, 3, 691–696.PubMedCrossRef
41.
go back to reference Thornton, A. S., Res, J., Mekel, J. M., & Jordaens, L. J. (2006). Use of advanced mapping and remote magnetic navigation to ablate left ventricular fascicular tachycardia. Pacing and Clinical Electrophysiology, 29, 685–688.PubMedCrossRef Thornton, A. S., Res, J., Mekel, J. M., & Jordaens, L. J. (2006). Use of advanced mapping and remote magnetic navigation to ablate left ventricular fascicular tachycardia. Pacing and Clinical Electrophysiology, 29, 685–688.PubMedCrossRef
42.
go back to reference de Torres, F., Szili-Torok, T., Orellana, F. J., & Jordaens, L. J. (2008). Ablation of idiopathic left ventricular tachycardia using remote magnetic navigation integrated with advanced mapping. Revista Española de Cardiología, 61, 1104–1106.PubMed de Torres, F., Szili-Torok, T., Orellana, F. J., & Jordaens, L. J. (2008). Ablation of idiopathic left ventricular tachycardia using remote magnetic navigation integrated with advanced mapping. Revista Española de Cardiología, 61, 1104–1106.PubMed
43.
go back to reference Konstantinidou, M., Koektuerk, B., Wissner, E., Schmidt, B., Zerm, T., Ouyang, F., Kuck, K. H., & Chun, J. K. (2011). Catheter ablation of right ventricular outflow tract tachycardia: a simplified remote-controlled approach. Europace, 13, 696–700.PubMedCrossRef Konstantinidou, M., Koektuerk, B., Wissner, E., Schmidt, B., Zerm, T., Ouyang, F., Kuck, K. H., & Chun, J. K. (2011). Catheter ablation of right ventricular outflow tract tachycardia: a simplified remote-controlled approach. Europace, 13, 696–700.PubMedCrossRef
44.
go back to reference Weiss, C., Antz, M., Eick, O., Eshagzaiy, K., Meinertz, T., & Willems, S. (2002). Radiofrequency catheter ablation using cooled electrodes: impact of irrigation flow rate and catheter contact pressure on lesion dimensions. Pace-Pacing and Clinical Electrophysiology, 25, 463–469.CrossRef Weiss, C., Antz, M., Eick, O., Eshagzaiy, K., Meinertz, T., & Willems, S. (2002). Radiofrequency catheter ablation using cooled electrodes: impact of irrigation flow rate and catheter contact pressure on lesion dimensions. Pace-Pacing and Clinical Electrophysiology, 25, 463–469.CrossRef
45.
go back to reference Schwagten, B., Bauernfeind, T., De Groot, N., Van Belle, Y., Haitsma, D., Jordaens, L., & Szili-Torok, T. (2010). Usefulness of the magnetic navigation system in ablation of ventricular tachycardia: acute and follow-up results compared to manual ablation. European Heart Journal, 31, 932–932. Schwagten, B., Bauernfeind, T., De Groot, N., Van Belle, Y., Haitsma, D., Jordaens, L., & Szili-Torok, T. (2010). Usefulness of the magnetic navigation system in ablation of ventricular tachycardia: acute and follow-up results compared to manual ablation. European Heart Journal, 31, 932–932.
Metadata
Title
Safety and efficacy of the remote magnetic navigation for ablation of ventricular tachycardias—a systematic review
Authors
Ferdi Akca
Ibrahim Önsesveren
Luc Jordaens
Tamas Szili-Torok
Publication date
01-06-2012
Publisher
Springer US
Published in
Journal of Interventional Cardiac Electrophysiology / Issue 1/2012
Print ISSN: 1383-875X
Electronic ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-011-9645-2

Other articles of this Issue 1/2012

Journal of Interventional Cardiac Electrophysiology 1/2012 Go to the issue