Published in:
01-04-2018 | Original Article
Adenoma Detection Rate Falls at the End of the Day in a Large Multi-site Sample
Authors:
Felippe O. Marcondes, Rebecca A. Gourevitch, Robert E. Schoen, Seth D. Crockett, Michele Morris, Ateev Mehrotra
Published in:
Digestive Diseases and Sciences
|
Issue 4/2018
Login to get access
Abstract
Background
There is concern that mental and physical fatigue among endoscopists over the course of the day will lead to lower adenoma detection rate (ADR). There are mixed findings in the prior literature on whether such an association exists.
Aims
The aim of this study was to measure the association between the number of colonoscopies performed in a day and ADR and withdrawal time.
Methods
We analyzed 86,624 colonoscopy and associated pathology reports between October 2013 and September 2015 from 131 physicians at two medical centers. A previously validated natural language processing program was used to abstract relevant data. We identified the order of colonoscopies performed in the physicians’ schedule and calculated the ADR and withdrawal time for each colonoscopy position.
Results
The ADR for our overall sample was 29.9 (CI 29.6–30.2). The ADR for colonoscopies performed at the 9th + position was significantly lower than those at the 1st–4th or 5th–8th position, 27.2 (CI 25.8–28.6) versus 29.9 (CI 29.5–30.3), 30.2 (CI 29.6–30.9), respectively. Withdrawal time steadily decreased by colonoscopy position going from 11.6 (CI 11.4–11.9) min for the 1st colonoscopy to 9.6 (8.9–10.3) min for the 9th colonoscopy.
Conclusion
In our study population, ADR and withdrawal time decrease by roughly 7 and 20%, respectively, by the end of the day. Our results imply that rather than mental or physical fatigue, lower ADR at the end of the day might be driven by endoscopists rushing.