Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 8/2013

01-12-2013 | Original paper

Automatic segmentation, detection and quantification of coronary artery stenoses on CTA

Authors: Rahil Shahzad, Hortense Kirişli, Coert Metz, Hui Tang, Michiel Schaap, Lucas van Vliet, Wiro Niessen, Theo van Walsum

Published in: The International Journal of Cardiovascular Imaging | Issue 8/2013

Login to get access

Abstract

Accurate detection and quantification of coronary artery stenoses is an essential requirement for treatment planning of patients with suspected coronary artery disease. We present a method to automatically detect and quantify coronary artery stenoses in computed tomography coronary angiography. First, centerlines are extracted using a two-point minimum cost path approach and a subsequent refinement step. The resulting centerlines are used as an initialization for lumen segmentation, performed using graph cuts. Then, the expected diameter of the healthy lumen is estimated by applying robust kernel regression to the coronary artery lumen diameter profile. Finally, stenoses are detected and quantified by computing the difference between estimated and expected diameter profiles. We evaluated our method using the data provided in the Coronary Artery Stenoses Detection and Quantification Evaluation Framework. Using 30 testing datasets, the method achieved a detection sensitivity of 29 % and a positive predictive value (PPV) of 24 % as compared to quantitative coronary angiography (QCA), and a sensitivity of 21 % and a PPV of 23 % as compared manual assessment based on consensus reading of CTA by 3 observers. The stenoses degree was estimated with an absolute average difference of 31 %, a root mean square difference of 39.3 % when compared to QCA, and a weighted kappa value of 0.29 when compared to CTA. A Dice of 68 and 65 % was reported for lumen segmentation of healthy and diseased vessel segments respectively. According to the ranking of the evaluation framework, our method finished fourth for stenosis detection, second for stenosis quantification and second for lumen segmentation.
Literature
1.
go back to reference WHO (2011) Cardiovascular diseases, fact sheet 317. World Health Organization WHO (2011) Cardiovascular diseases, fact sheet 317. World Health Organization
2.
go back to reference Roger V, Go A, Lloyd-Jones D, Benjamin E, Berry J. Borden, W., Bravata D, Dai S, Ford E, Fox C et al (2012) Heart disease and stroke statistics2012 update a report from the american heart association. Circulation 125(1):e2–e220PubMedCrossRef Roger V, Go A, Lloyd-Jones D, Benjamin E, Berry J. Borden, W., Bravata D, Dai S, Ford E, Fox C et al (2012) Heart disease and stroke statistics2012 update a report from the american heart association. Circulation 125(1):e2–e220PubMedCrossRef
3.
go back to reference Fayad Z, Fuster V (2001) Clinical imaging of the high-risk or vulnerable atherosclerotic plaque. Circ Res 89(4):305–316PubMedCrossRef Fayad Z, Fuster V (2001) Clinical imaging of the high-risk or vulnerable atherosclerotic plaque. Circ Res 89(4):305–316PubMedCrossRef
4.
go back to reference Weustink A, de Feyter P (2011) The role of multi-slice computed tomography in stable angina management: a current perspective. Neth Heart J 19(7–8):336–343 Weustink A, de Feyter P (2011) The role of multi-slice computed tomography in stable angina management: a current perspective. Neth Heart J 19(7–8):336–343
5.
go back to reference Miller JM, Rochitte CE, Dewey M, Arbab-Zadeh A, Niinuma H, Gottlieb I, Paul N, Clouse ME, Shapiro EP, Hoe J et al (2008) Diagnostic performance of coronary angiography by 64-row CT. New Engl J Med 359(22):2324–2336PubMedCrossRef Miller JM, Rochitte CE, Dewey M, Arbab-Zadeh A, Niinuma H, Gottlieb I, Paul N, Clouse ME, Shapiro EP, Hoe J et al (2008) Diagnostic performance of coronary angiography by 64-row CT. New Engl J Med 359(22):2324–2336PubMedCrossRef
6.
go back to reference Pugliese F, Hunink M, Gruszczynska K, Alberghina F, Malagó R, van Pelt N, Mollet N, Cademartiri F, Weustink A, Meijboom W et al (2009) Learning curve for coronary CT angiography: what constitutes sufficient training? Radiology 251(2):359–368PubMedCrossRef Pugliese F, Hunink M, Gruszczynska K, Alberghina F, Malagó R, van Pelt N, Mollet N, Cademartiri F, Weustink A, Meijboom W et al (2009) Learning curve for coronary CT angiography: what constitutes sufficient training? Radiology 251(2):359–368PubMedCrossRef
7.
go back to reference Melchionna S, Amati G, Bernaschi M, Bisson M, Succi S, Mitsouras D, Rybicki FJ (2013) Risk assessment of atherosclerotic plaques based on global biomechanics. Med Eng Phys 35(9):1290–1297 Melchionna S, Amati G, Bernaschi M, Bisson M, Succi S, Mitsouras D, Rybicki FJ (2013) Risk assessment of atherosclerotic plaques based on global biomechanics. Med Eng Phys 35(9):1290–1297
8.
go back to reference Min JK, Leipsic J, Pencina MJ, Berman DS, Koo BK, van Mieghem C, Erglis A, Lin FY, Dunning AM, Apruzzese P et al (2012) Diagnostic accuracy of fractional flow reserve from anatomic CT angiography. Jama 308(12):1237–1245PubMedCrossRef Min JK, Leipsic J, Pencina MJ, Berman DS, Koo BK, van Mieghem C, Erglis A, Lin FY, Dunning AM, Apruzzese P et al (2012) Diagnostic accuracy of fractional flow reserve from anatomic CT angiography. Jama 308(12):1237–1245PubMedCrossRef
9.
go back to reference Kirişli H, Schaap M, Metz C, Dharampal A, Meijboom W, Papadopoulou S, Dedic A, Nieman K, de Graaf M, Meijs M, Cramer M, Broersen A, Cetin S, Eslami A, Florez-Valencia L, Lor K, Matuszewski B, Melki I, Mohr B, Oksuz I, Shahzad R, Wang C, Kitslaar P, Unal G, Katouzian A, Orkisz M, Chen C, Precioso F, Najman L, Masood S, Unay D, van Vliet L, Moreno R, Goldenberg R, Vucini E, Krestin G, Niessen W, van Walsum T (2013) Standardized evaluation framework for evaluating coronary artery stenosis detection, stenosis quantification and lumen segmentation algorithms in computed tomography angiography. Med Image Anal 17(8):859–876 Kirişli H, Schaap M, Metz C, Dharampal A, Meijboom W, Papadopoulou S, Dedic A, Nieman K, de Graaf M, Meijs M, Cramer M, Broersen A, Cetin S, Eslami A, Florez-Valencia L, Lor K, Matuszewski B, Melki I, Mohr B, Oksuz I, Shahzad R, Wang C, Kitslaar P, Unal G, Katouzian A, Orkisz M, Chen C, Precioso F, Najman L, Masood S, Unay D, van Vliet L, Moreno R, Goldenberg R, Vucini E, Krestin G, Niessen W, van Walsum T (2013) Standardized evaluation framework for evaluating coronary artery stenosis detection, stenosis quantification and lumen segmentation algorithms in computed tomography angiography. Med Image Anal 17(8):859–876
10.
go back to reference Arnoldi E, Gebregziabher M, Schoepf U, Goldenberg R, Ramos-Duran L, Zwerner P, Nikolaou K, Reiser M, Costello P, Thilo C (2010) Automated computer-aided stenosis detection at coronary CT angiography: initial experience. Eur Radiol 20(5):1160–1167PubMedCrossRef Arnoldi E, Gebregziabher M, Schoepf U, Goldenberg R, Ramos-Duran L, Zwerner P, Nikolaou K, Reiser M, Costello P, Thilo C (2010) Automated computer-aided stenosis detection at coronary CT angiography: initial experience. Eur Radiol 20(5):1160–1167PubMedCrossRef
11.
go back to reference Halpern E, Halpern D (2011) Diagnosis of coronary stenosis with CT angiography: comparison of automated computer diagnosis with expert readings. Acad Radiol 18(3):324–333PubMedCrossRef Halpern E, Halpern D (2011) Diagnosis of coronary stenosis with CT angiography: comparison of automated computer diagnosis with expert readings. Acad Radiol 18(3):324–333PubMedCrossRef
12.
go back to reference Khan M, Wesarg S, Gurung J, Dogan S, Maataoui A, Brehmer B, Herzog C, Ackermann H, Aßmus B, Vogl, T (2006) Facilitating coronary artery evaluation in MDCT using a 3D automatic vessel segmentation tool. Eur Radiol 16(8):1789–1795PubMedCrossRef Khan M, Wesarg S, Gurung J, Dogan S, Maataoui A, Brehmer B, Herzog C, Ackermann H, Aßmus B, Vogl, T (2006) Facilitating coronary artery evaluation in MDCT using a 3D automatic vessel segmentation tool. Eur Radiol 16(8):1789–1795PubMedCrossRef
13.
go back to reference Kelm B, Mittal S, Zheng Y, Tsymbal A, Bernhardt D, Vega-Higuera F, Zhou S, Meer P, Comaniciu D (2011) Detection, grading and classification of coronary stenoses in computed tomography angiography. Medical Image Computing and Computer-Assisted Intervention—MICCAI, pp 25–32 Kelm B, Mittal S, Zheng Y, Tsymbal A, Bernhardt D, Vega-Higuera F, Zhou S, Meer P, Comaniciu D (2011) Detection, grading and classification of coronary stenoses in computed tomography angiography. Medical Image Computing and Computer-Assisted Intervention—MICCAI, pp 25–32
14.
go back to reference Wesarg S, Khan M, Firle E (2006) Localizing calcifications in cardiac CT data sets using a new vessel segmentation approach. J Digit Imaging 19(3):249–257PubMedCrossRef Wesarg S, Khan M, Firle E (2006) Localizing calcifications in cardiac CT data sets using a new vessel segmentation approach. J Digit Imaging 19(3):249–257PubMedCrossRef
15.
go back to reference Xu Y, Liang G, Hu G, Yang Y, Geng J, Saha P (2012) Quantification of coronary arterial stenoses in CTA using fuzzy distance transform. Comput Med Imaging Graph 36(1):11–24PubMedCrossRef Xu Y, Liang G, Hu G, Yang Y, Geng J, Saha P (2012) Quantification of coronary arterial stenoses in CTA using fuzzy distance transform. Comput Med Imaging Graph 36(1):11–24PubMedCrossRef
16.
go back to reference Saur S, Alkadhi H, Desbiolles L, Székely G, Cattin P (2008) Automatic detection of calcified coronary plaques in computed tomography data sets. Medical Image Computing and Computer-Assisted Intervention—MICCAI, pp 170–177 Saur S, Alkadhi H, Desbiolles L, Székely G, Cattin P (2008) Automatic detection of calcified coronary plaques in computed tomography data sets. Medical Image Computing and Computer-Assisted Intervention—MICCAI, pp 170–177
17.
go back to reference Tessmann M, Vega-Higuera F, Fritz D, Scheuering M, Greiner G (2009) Multi-scale feature extraction for learning-based classification of coronary artery stenosis. In: SPIE medical imaging, International Society for Optics and Photonics, pp 726002–726002 Tessmann M, Vega-Higuera F, Fritz D, Scheuering M, Greiner G (2009) Multi-scale feature extraction for learning-based classification of coronary artery stenosis. In: SPIE medical imaging, International Society for Optics and Photonics, pp 726002–726002
18.
go back to reference Zuluaga MA, Magnin IE, Hoyos MH, Leyton EJD, Lozano F, Orkisz M (2011) Automatic detection of abnormal vascular cross-sections based on density level detection and support vector machines. Int J Comput Assist Radiol Surg 6(2):163–174PubMedCrossRef Zuluaga MA, Magnin IE, Hoyos MH, Leyton EJD, Lozano F, Orkisz M (2011) Automatic detection of abnormal vascular cross-sections based on density level detection and support vector machines. Int J Comput Assist Radiol Surg 6(2):163–174PubMedCrossRef
19.
go back to reference Agatston A, Janowitz W, Hildner F, Zusmer N, Viamonte Jr M, Detrano R (1990) Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 15(4):827PubMedCrossRef Agatston A, Janowitz W, Hildner F, Zusmer N, Viamonte Jr M, Detrano R (1990) Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 15(4):827PubMedCrossRef
20.
go back to reference Metz C, Schaap M, Weustink A, Mollet N, van Walsum T, Niessen W (2009) Coronary centerline extraction from ct coronary angiography images using a minimum cost path approach. Med Phys 36(12):5568–5579PubMedCrossRef Metz C, Schaap M, Weustink A, Mollet N, van Walsum T, Niessen W (2009) Coronary centerline extraction from ct coronary angiography images using a minimum cost path approach. Med Phys 36(12):5568–5579PubMedCrossRef
21.
go back to reference Frangi A, Niessen W, Vincken K, Viergever M (1998) Multiscale vessel enhancement filtering. Medical Image Computing and Computer-Assisted Intervention—MICCAI, pp 130–137 Frangi A, Niessen W, Vincken K, Viergever M (1998) Multiscale vessel enhancement filtering. Medical Image Computing and Computer-Assisted Intervention—MICCAI, pp 130–137
22.
go back to reference Rybicki FJ, Otero HJ, Steigner ML, Vorobiof G, Nallamshetty L, Mitsouras D, Ersoy H, Mather RT, Judy PF, Cai T et al (2008) Initial evaluation of coronary images from 320-detector row computed tomography. Int J Cardiovasc Imaging 24(5):535–546PubMedCrossRef Rybicki FJ, Otero HJ, Steigner ML, Vorobiof G, Nallamshetty L, Mitsouras D, Ersoy H, Mather RT, Judy PF, Cai T et al (2008) Initial evaluation of coronary images from 320-detector row computed tomography. Int J Cardiovasc Imaging 24(5):535–546PubMedCrossRef
23.
go back to reference Steigner ML, Mitsouras D, Whitmore AG, Otero HJ, Wang C, Buckley O, Levit NA, Hussain AZ, Cai T, Mather RT et al. (2010) Iodinated contrast opacification gradients in normal coronary arteries imaged with prospectively ECG-gated single heart beat 320-detector row computed tomography. Circ Cardiovasc Imaging 3(2):179–186PubMedCrossRef Steigner ML, Mitsouras D, Whitmore AG, Otero HJ, Wang C, Buckley O, Levit NA, Hussain AZ, Cai T, Mather RT et al. (2010) Iodinated contrast opacification gradients in normal coronary arteries imaged with prospectively ECG-gated single heart beat 320-detector row computed tomography. Circ Cardiovasc Imaging 3(2):179–186PubMedCrossRef
24.
go back to reference Tang H, Walsum T, van Onkelen RS, Hameeteman R, Klein S, Schaap M, Tori FL, van den Bouwhuijsen QJ, Witteman J, der Lugt A et al. (2012) Semiautomatic carotid lumen segmentation for quantification of lumen geometry in multispectral MRI. Med Image Anal 16:1201–1215 Tang H, Walsum T, van Onkelen RS, Hameeteman R, Klein S, Schaap M, Tori FL, van den Bouwhuijsen QJ, Witteman J, der Lugt A et al. (2012) Semiautomatic carotid lumen segmentation for quantification of lumen geometry in multispectral MRI. Med Image Anal 16:1201–1215
25.
go back to reference Gülsün MA, Tek H (2008) Robust vessel tree modeling. In: Medical Image Computing and Computer-Assisted Interventation—MICCAI, Springer, pp 602–611 Gülsün MA, Tek H (2008) Robust vessel tree modeling. In: Medical Image Computing and Computer-Assisted Interventation—MICCAI, Springer, pp 602–611
26.
go back to reference Carreira-Perpinan M (2007) Gaussian mean-shift is an EM algorithm. Pattern Anal Mach Intell IEEE Trans 29(5):767–776CrossRef Carreira-Perpinan M (2007) Gaussian mean-shift is an EM algorithm. Pattern Anal Mach Intell IEEE Trans 29(5):767–776CrossRef
27.
go back to reference van Walsum T, Schaap M, Metz C, van der Giessen A, Niessen W (2008) Averaging centerlines: mean shift on paths. Medical Image Computing and Computer-Assisted Intervention—MICCAI, pp 900–907 van Walsum T, Schaap M, Metz C, van der Giessen A, Niessen W (2008) Averaging centerlines: mean shift on paths. Medical Image Computing and Computer-Assisted Intervention—MICCAI, pp 900–907
28.
go back to reference Dijkstra E (1959) A note on two problems in connexion with graphs. Numerische mathematik 1(1):269–271CrossRef Dijkstra E (1959) A note on two problems in connexion with graphs. Numerische mathematik 1(1):269–271CrossRef
29.
go back to reference Schaap M, Neefjes L, Metz C, van der Giessen A, Weustink A, Mollet N, Wentzel J, van Walsum T, Niessen W (2009) Coronary lumen segmentation using graph cuts and robust kernel regression. In: Information processing in medical imaging. Springer, pp 528–539 Schaap M, Neefjes L, Metz C, van der Giessen A, Weustink A, Mollet N, Wentzel J, van Walsum T, Niessen W (2009) Coronary lumen segmentation using graph cuts and robust kernel regression. In: Information processing in medical imaging. Springer, pp 528–539
30.
go back to reference Debruyne M, Hubert M, Suykens J (2008) Model selection in kernel based regression using the influence function. J Mach Learn Res 9:2377–2400 Debruyne M, Hubert M, Suykens J (2008) Model selection in kernel based regression using the influence function. J Mach Learn Res 9:2377–2400
31.
go back to reference Shahzad R, van Walsum T, Kirişli H, Tang H, Metz C, Schaap M, van Vliet L, Niessen W (2012) Automatic detection, quantification and lumen segmentation of the coronary arteries using two-point centerline extraction scheme. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge" Shahzad R, van Walsum T, Kirişli H, Tang H, Metz C, Schaap M, van Vliet L, Niessen W (2012) Automatic detection, quantification and lumen segmentation of the coronary arteries using two-point centerline extraction scheme. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge"
32.
go back to reference Shahzad R, Schaap M, van Walsum T, Klien S, Weustink AC, van Vliet LJ, Niessen WJ (2010) A patient-specific coronary density estimate. In: Biomedical imaging: from nano to macro, 2010 IEEE international symposium on, IEEE, pp 9–12 Shahzad R, Schaap M, van Walsum T, Klien S, Weustink AC, van Vliet LJ, Niessen WJ (2010) A patient-specific coronary density estimate. In: Biomedical imaging: from nano to macro, 2010 IEEE international symposium on, IEEE, pp 9–12
33.
go back to reference Kitamura Y, Li Y, Ito W (2012) Automatic coronary extraction by supervised detection and shape matching. In: Biomedical imaging (ISBI), 2012 9th IEEE international symposium on, IEEE, pp 234–237 Kitamura Y, Li Y, Ito W (2012) Automatic coronary extraction by supervised detection and shape matching. In: Biomedical imaging (ISBI), 2012 9th IEEE international symposium on, IEEE, pp 234–237
34.
go back to reference Yang G, Kitslaar P, Frenay M, Broersen A, Boogers MJ, Bax JJ, Reiber JH, Dijkstra J (2012) Automatic centerline extraction of coronary arteries in coronary computed tomographic angiography. Int J Cardiovasc Imaging 28(4):921–933PubMedCrossRef Yang G, Kitslaar P, Frenay M, Broersen A, Boogers MJ, Bax JJ, Reiber JH, Dijkstra J (2012) Automatic centerline extraction of coronary arteries in coronary computed tomographic angiography. Int J Cardiovasc Imaging 28(4):921–933PubMedCrossRef
35.
go back to reference Goldenberg R, Eilot D, Begelman G, Walach E, Ben-Ishai E, Peled N (2012) Computer-aided simple triage (CAST) for coronary CT angiography (CCTA). Int J Comput Assist Radiol Surg 7(6):819–827PubMedCrossRef Goldenberg R, Eilot D, Begelman G, Walach E, Ben-Ishai E, Peled N (2012) Computer-aided simple triage (CAST) for coronary CT angiography (CCTA). Int J Comput Assist Radiol Surg 7(6):819–827PubMedCrossRef
36.
go back to reference Zambal S, Hladuvka J, Kanitsar A, Bühler K (2008) Shape and appearance models for automatic coronary artery tracking. Insight J 4:1–8 Zambal S, Hladuvka J, Kanitsar A, Bühler K (2008) Shape and appearance models for automatic coronary artery tracking. Insight J 4:1–8
37.
go back to reference Duval M, Ouzeau E, Precioso F, Matuszewski B (2012) Coronary artery stenoses detection with random forest. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge" Duval M, Ouzeau E, Precioso F, Matuszewski B (2012) Coronary artery stenoses detection with random forest. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge"
38.
go back to reference Cetin S, Unal G (2012) Automatic detection of coronary artery stenosis in CTA based on vessel intensity and geometric features. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge" Cetin S, Unal G (2012) Automatic detection of coronary artery stenosis in CTA based on vessel intensity and geometric features. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge"
39.
go back to reference Broersen A, Kitslaar P, Frenay M, Dijkstra J (2012) FrenchCoast: fast, robust extraction for the nice challenge on coronary artery segmentation of the tree. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge" Broersen A, Kitslaar P, Frenay M, Dijkstra J (2012) FrenchCoast: fast, robust extraction for the nice challenge on coronary artery segmentation of the tree. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge"
40.
go back to reference Flórez Valencia L, Orkisz M, Corredor Jerez, RA, Torres González JS, Correa Agudelo EM, Mouton C, Hernández Hoyos M (2012) Coronary artery segmentation and stenosis quantification in CT images with use of a right generalized cylinder model. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge" Flórez Valencia L, Orkisz M, Corredor Jerez, RA, Torres González JS, Correa Agudelo EM, Mouton C, Hernández Hoyos M (2012) Coronary artery segmentation and stenosis quantification in CT images with use of a right generalized cylinder model. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge"
41.
go back to reference Mohr B, Masood S, Plakas C (2012) Accurate stenosis detection and quantification in coronary CTA. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge" Mohr B, Masood S, Plakas C (2012) Accurate stenosis detection and quantification in coronary CTA. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge"
42.
go back to reference Öksüz d, Ünay D, Kadipaşaoğlu K (2012) A hybrid method for coronary artery stenosis detection and quantification. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge" Öksüz d, Ünay D, Kadipaşaoğlu K (2012) A hybrid method for coronary artery stenosis detection and quantification. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge"
43.
go back to reference Eslami A, Aboee A, Hodaei Z, Moghaddam MJ, Carlier S, Katouzian A, Navab N (2012) Quantification of coronary arterial stenosis by inflating tubes in CTA images. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge" Eslami A, Aboee A, Hodaei Z, Moghaddam MJ, Carlier S, Katouzian A, Navab N (2012) Quantification of coronary arterial stenosis by inflating tubes in CTA images. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge"
44.
go back to reference Wang C, Moreno R, Smedby Ö (2012) Vessel segmentation using implicit model-guided level sets. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge" Wang C, Moreno R, Smedby Ö (2012) Vessel segmentation using implicit model-guided level sets. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge"
45.
go back to reference Lor K, Chen C (2012) Probabilistic model based evaluation of coronary artery stenosis on CTA. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge" Lor K, Chen C (2012) Probabilistic model based evaluation of coronary artery stenosis on CTA. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge"
46.
go back to reference Melki I, Talbot H, Cousty J, Pruvot C, Knoplioch J, Launay L, Najman L (2012) Automatic coronary arteries stenoses detection in 3D CTA. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge" Melki I, Talbot H, Cousty J, Pruvot C, Knoplioch J, Launay L, Najman L (2012) Automatic coronary arteries stenoses detection in 3D CTA. In: Proceedings of MICCAI workshop "3D cardiovascular imaging: a MICCAI segmentation challenge"
Metadata
Title
Automatic segmentation, detection and quantification of coronary artery stenoses on CTA
Authors
Rahil Shahzad
Hortense Kirişli
Coert Metz
Hui Tang
Michiel Schaap
Lucas van Vliet
Wiro Niessen
Theo van Walsum
Publication date
01-12-2013
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 8/2013
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-013-0271-1

Other articles of this Issue 8/2013

The International Journal of Cardiovascular Imaging 8/2013 Go to the issue