Published in: The International Journal of Cardiovascular Imaging 7/2013

01-10-2013 | Original Paper

Image quality of low-dose CCTA in obese patients: impact of high-definition computed tomography and adaptive statistical iterative reconstruction

Authors: Cathérine Gebhard, Tobias A. Fuchs, Michael Fiechter, Julia Stehli, Barbara E. Stähli, Oliver Gaemperli, Philipp A. Kaufmann

Published in: The International Journal of Cardiovascular Imaging | Issue 7/2013

Login to get access

Abstract

The accuracy of coronary computed tomography angiography (CCTA) in obese persons is compromised by increased image noise. We investigated CCTA image quality acquired on a high-definition 64-slice CT scanner using modern adaptive statistical iterative reconstruction (ASIR). Seventy overweight and obese patients (24 males; mean age 57 years, mean body mass index 33 kg/m2) were studied with clinically-indicated contrast enhanced CCTA. Thirty-five patients underwent a standard definition protocol with filtered backprojection reconstruction (SD-FBP) while 35 patients matched for gender, age, body mass index and coronary artery calcifications underwent a novel high definition protocol with ASIR (HD-ASIR). Segment by segment image quality was assessed using a four-point scale (1 = excellent, 2 = good, 3 = moderate, 4 = non-diagnostic) and revealed better scores for HD-ASIR compared to SD-FBP (1.5 ± 0.43 vs. 1.8 ± 0.48; p < 0.05). The smallest detectable vessel diameter was also improved, 1.0 ± 0.5 mm for HD-ASIR as compared to 1.4 ± 0.4 mm for SD-FBP (p < 0.001). Average vessel attenuation was higher for HD-ASIR (388.3 ± 109.6 versus 350.6 ± 90.3 Hounsfield Units, HU; p < 0.05), while image noise, signal-to-noise ratio and contrast-to noise ratio did not differ significantly between reconstruction protocols (p = NS). The estimated effective radiation doses were similar, 2.3 ± 0.1 and 2.5 ± 0.1 mSv (HD-ASIR vs. SD-ASIR respectively). Compared to a standard definition backprojection protocol (SD-FBP), a newer high definition scan protocol in combination with ASIR (HD-ASIR) incrementally improved image quality and visualization of distal coronary artery segments in overweight and obese individuals, without increasing image noise and radiation dose.
Literature
1.
go back to reference Romero-Corral A, Montori VM, Somers VK, Korinek J, Thomas RJ, Allison TG et al (2006) Association of bodyweight with total mortality and with cardiovascular events in coronary artery disease: a systematic review of cohort studies. Lancet 368(9536):666–678PubMedCrossRef Romero-Corral A, Montori VM, Somers VK, Korinek J, Thomas RJ, Allison TG et al (2006) Association of bodyweight with total mortality and with cardiovascular events in coronary artery disease: a systematic review of cohort studies. Lancet 368(9536):666–678PubMedCrossRef
2.
go back to reference Yoshimura N, Sabir A, Kubo T, Lin PJ, Clouse ME, Hatabu H (2006) Correlation between image noise and body weight in coronary CTA with 16-row MDCT. Acad Radiol 13(3):324–328PubMedCrossRef Yoshimura N, Sabir A, Kubo T, Lin PJ, Clouse ME, Hatabu H (2006) Correlation between image noise and body weight in coronary CTA with 16-row MDCT. Acad Radiol 13(3):324–328PubMedCrossRef
3.
go back to reference Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA (2005) Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46(3):552–557PubMedCrossRef Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA (2005) Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46(3):552–557PubMedCrossRef
4.
go back to reference Chinnaiyan KM, McCullough PA, Flohr TG, Wegner JH, Raff GL (2009) Improved noninvasive coronary angiography in morbidly obese patients with dual-source computed tomography. J Cardiovasc Comput Tomog. 3(1):35–42CrossRef Chinnaiyan KM, McCullough PA, Flohr TG, Wegner JH, Raff GL (2009) Improved noninvasive coronary angiography in morbidly obese patients with dual-source computed tomography. J Cardiovasc Comput Tomog. 3(1):35–42CrossRef
5.
go back to reference Silva AC, Lawder HJ, Hara A, Kujak J, Pavlicek W (2010) Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. AJR Am J Roentgenol 194(1):191–199PubMedCrossRef Silva AC, Lawder HJ, Hara A, Kujak J, Pavlicek W (2010) Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. AJR Am J Roentgenol 194(1):191–199PubMedCrossRef
6.
go back to reference Leipsic J, Heilbron BG, Hague C (2012) Iterative reconstruction for coronary CT angiography: finding its way. Int J Cardiovasc Imaging 28(3):613–620PubMedCrossRef Leipsic J, Heilbron BG, Hague C (2012) Iterative reconstruction for coronary CT angiography: finding its way. Int J Cardiovasc Imaging 28(3):613–620PubMedCrossRef
7.
go back to reference Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, Lin FY et al (2010) Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study. AJR Am J Roentgenol 195(3):655–660PubMedCrossRef Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, Lin FY et al (2010) Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study. AJR Am J Roentgenol 195(3):655–660PubMedCrossRef
8.
go back to reference Pontone G, Andreini D, Bartorelli AL, Bertella E, Mushtaq S, Foti C et al (2012) Feasibility and diagnostic accuracy of a low radiation exposure protocol for prospective ECG-triggering coronary MDCT angiography. Clin Radiol 67(3):207–215PubMedCrossRef Pontone G, Andreini D, Bartorelli AL, Bertella E, Mushtaq S, Foti C et al (2012) Feasibility and diagnostic accuracy of a low radiation exposure protocol for prospective ECG-triggering coronary MDCT angiography. Clin Radiol 67(3):207–215PubMedCrossRef
9.
go back to reference Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, Lin FY et al (2010) Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography. AJR Am J Roentgenol 195(3):649–654PubMedCrossRef Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, Lin FY et al (2010) Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography. AJR Am J Roentgenol 195(3):649–654PubMedCrossRef
10.
go back to reference Kazakauskaite E, Husmann L, Stehli J, Fuchs T, Fiechter M, Klaeser B et al (2013) Image quality in low-dose coronary computed tomography angiography with a new high-definition CT scanner. Int J Cardiovasc Imaging 29(2):471–477PubMedCrossRef Kazakauskaite E, Husmann L, Stehli J, Fuchs T, Fiechter M, Klaeser B et al (2013) Image quality in low-dose coronary computed tomography angiography with a new high-definition CT scanner. Int J Cardiovasc Imaging 29(2):471–477PubMedCrossRef
11.
go back to reference Desai GS, Uppot RN, Yu EW, Kambadakone AR, Sahani DV (2012) Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults. Eur Radiol 22(8):1631–1640PubMedCrossRef Desai GS, Uppot RN, Yu EW, Kambadakone AR, Sahani DV (2012) Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults. Eur Radiol 22(8):1631–1640PubMedCrossRef
12.
go back to reference Ghadri JR, Kuest SM, Goetti R, Fiechter M, Pazhenkottil AP, Nkoulou RN et al (2011) Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition. Int J Cardiovasc Imaging 28(5):1217–1225PubMedCrossRef Ghadri JR, Kuest SM, Goetti R, Fiechter M, Pazhenkottil AP, Nkoulou RN et al (2011) Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition. Int J Cardiovasc Imaging 28(5):1217–1225PubMedCrossRef
13.
go back to reference Buechel RR, Husmann L, Herzog BA, Pazhenkottil AP, Nkoulou R, Ghadri JR et al (2011) Low-dose computed tomography coronary angiography with prospective electrocardiogram triggering: feasibility in a large population. J Am Coll Cardiol 57(3):332–336PubMedCrossRef Buechel RR, Husmann L, Herzog BA, Pazhenkottil AP, Nkoulou R, Ghadri JR et al (2011) Low-dose computed tomography coronary angiography with prospective electrocardiogram triggering: feasibility in a large population. J Am Coll Cardiol 57(3):332–336PubMedCrossRef
14.
go back to reference Husmann L, Herzog BA, Gaemperli O, Tatsugami F, Burkhard N, Valenta I et al (2009) Diagnostic accuracy of computed tomography coronary angiography and evaluation of stress-only single-photon emission computed tomography/computed tomography hybrid imaging: comparison of prospective electrocardiogram-triggering vs. retrospective gating. Eur Heart J 30(5):600–607PubMedCrossRef Husmann L, Herzog BA, Gaemperli O, Tatsugami F, Burkhard N, Valenta I et al (2009) Diagnostic accuracy of computed tomography coronary angiography and evaluation of stress-only single-photon emission computed tomography/computed tomography hybrid imaging: comparison of prospective electrocardiogram-triggering vs. retrospective gating. Eur Heart J 30(5):600–607PubMedCrossRef
15.
go back to reference Herzog BA, Husmann L, Burkhard N, Valenta I, Gaemperli O, Tatsugami F et al (2009) Low-dose CT coronary angiography using prospective ECG-triggering: impact of mean heart rate and heart rate variability on image quality. Acad Radiol 16(1):15–21PubMedCrossRef Herzog BA, Husmann L, Burkhard N, Valenta I, Gaemperli O, Tatsugami F et al (2009) Low-dose CT coronary angiography using prospective ECG-triggering: impact of mean heart rate and heart rate variability on image quality. Acad Radiol 16(1):15–21PubMedCrossRef
16.
go back to reference Raff GL, Goldstein JA (2007) Coronary angiography by computed tomography: coronary imaging evolves. J Am Coll Cardiol 49(18):1830–1833PubMedCrossRef Raff GL, Goldstein JA (2007) Coronary angiography by computed tomography: coronary imaging evolves. J Am Coll Cardiol 49(18):1830–1833PubMedCrossRef
17.
go back to reference McNulty PH, Ettinger SM, Field JM, Gilchrist IC, Kozak M, Chambers CE et al (2002) Cardiac catheterization in morbidly obese patients. Catheter Cardiovasc Interv 56(2):174–177PubMedCrossRef McNulty PH, Ettinger SM, Field JM, Gilchrist IC, Kozak M, Chambers CE et al (2002) Cardiac catheterization in morbidly obese patients. Catheter Cardiovasc Interv 56(2):174–177PubMedCrossRef
18.
go back to reference Leschka S, Stinn B, Schmid F, Schultes B, Thurnheer M, Baumueller S et al (2009) Dual source CT coronary angiography in severely obese patients: trading off temporal resolution and image noise. Invest Radiol 44(11):720–727PubMedCrossRef Leschka S, Stinn B, Schmid F, Schultes B, Thurnheer M, Baumueller S et al (2009) Dual source CT coronary angiography in severely obese patients: trading off temporal resolution and image noise. Invest Radiol 44(11):720–727PubMedCrossRef
19.
go back to reference Kropil P, Rojas CA, Ghoshhajra B, Lanzman RS, Miese FR, Scherer A et al (2012) Prospectively ECG-triggered high-pitch spiral acquisition for cardiac CT angiography in routine clinical practice: initial results. J Thorac Imaging 27(3):194–201PubMedCrossRef Kropil P, Rojas CA, Ghoshhajra B, Lanzman RS, Miese FR, Scherer A et al (2012) Prospectively ECG-triggered high-pitch spiral acquisition for cardiac CT angiography in routine clinical practice: initial results. J Thorac Imaging 27(3):194–201PubMedCrossRef
20.
go back to reference Srichai MB, Lim RP, Donnino R, Mannelli L, Hiralal R, Avery R et al (2012) Low-dose, prospective triggered high-pitch spiral coronary computed tomography angiography: comparison with retrospective spiral technique. Acad Radiol 19(5):554–561PubMedCrossRef Srichai MB, Lim RP, Donnino R, Mannelli L, Hiralal R, Avery R et al (2012) Low-dose, prospective triggered high-pitch spiral coronary computed tomography angiography: comparison with retrospective spiral technique. Acad Radiol 19(5):554–561PubMedCrossRef
21.
go back to reference Paul NS, Kashani H, Odedra D, Ursani A, Ray C, Rogalla P (2011) The influence of chest wall tissue composition in determining image noise during cardiac CT. AJR Am J Roentgenol 197(6):1328–1334PubMedCrossRef Paul NS, Kashani H, Odedra D, Ursani A, Ray C, Rogalla P (2011) The influence of chest wall tissue composition in determining image noise during cardiac CT. AJR Am J Roentgenol 197(6):1328–1334PubMedCrossRef
22.
go back to reference Xu L, Zhang Z (2010) Coronary CT angiography with low radiation dose. Int J Cardiovasc Imaging 26(Suppl 1):17–25PubMedCrossRef Xu L, Zhang Z (2010) Coronary CT angiography with low radiation dose. Int J Cardiovasc Imaging 26(Suppl 1):17–25PubMedCrossRef
23.
go back to reference Gebhard C, Fiechter M, Fuchs TA, Ghadri JR, Herzog BA, Kuhn F et al (2012) Coronary artery calcium scoring: influence of adaptive statistical iterative reconstruction using 64-MDCT. Int J Cardiol. doi:10.1016/j.ijcard.2012.08.003 Gebhard C, Fiechter M, Fuchs TA, Ghadri JR, Herzog BA, Kuhn F et al (2012) Coronary artery calcium scoring: influence of adaptive statistical iterative reconstruction using 64-MDCT. Int J Cardiol. doi:10.​1016/​j.​ijcard.​2012.​08.​003
Metadata
Title
Image quality of low-dose CCTA in obese patients: impact of high-definition computed tomography and adaptive statistical iterative reconstruction
Authors
Cathérine Gebhard
Tobias A. Fuchs
Michael Fiechter
Julia Stehli
Barbara E. Stähli
Oliver Gaemperli
Philipp A. Kaufmann
Publication date
01-10-2013
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 7/2013
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-013-0228-4

Other articles of this Issue 7/2013

The International Journal of Cardiovascular Imaging 7/2013 Go to the issue