Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 8/2012

01-12-2012 | Original Paper

Stent strut coverage of titanium-nitride-oxide coated stent compared to paclitaxel-eluting stent in acute myocardial infarction: TITAX-OCT study

Authors: Tuomas Lehtinen, K. E. Juhani Airaksinen, Antti Ylitalo, Pasi P. Karjalainen

Published in: The International Journal of Cardiovascular Imaging | Issue 8/2012

Login to get access

Abstract

Drug-eluting stents (DES) have reduced the rate of restenosis but recent studies have raised concern over the risk of late stent thrombosis (LST). Incomplete stent endothelialization and delayed vascular healing have been associated with LST. The titanium-nitride-oxide coated bio-active stent (BAS) has shown promising results in patients with acute coronary syndromes, but there is little long-term optical coherence tomography (OCT) data comparing BAS with DES. The TITAX-AMI trial is a prospective, randomized, multicenter trial comparing BAS to paclitaxel-eluting stent (PES) in 425 patients with acute myocardial infarction. A total of 18 patients (9 per group) with no major cardiac events during follow-up, were enrolled in this substudy >36 months (mean 47 months) after stent implantation. Quantitative coronary angiography was performed and stent strut endothelialization and vascular healing were assessed with OCT. The binary stent strut coverage was significantly higher in the BAS group compared with the PES group (99.6 vs. 89.2%, p < 0.001) and there were less malapposed struts in the BAS group (0.2 vs. 13.8%, respectively, p < 0.001). The neointimal hyperplasia (NIH) thickness (266 ± 166 vs. 126 μm ± 126 μm, p < 0.001) and percentage of NIH area (26.2 vs. 7.6%, p < 0.001) were greater in the BAS group than in the PES group. Late incomplete endothelialization was not uncommon after PES implantation. Stents in the BAS group were completely endothelialized. This difference may contribute to the more common LST after PES implantation in the TITAX-AMI trial.
Literature
1.
go back to reference Nordmann AJ, Briel M, Bucher HC (2006) Mortality in randomized controlled trials comparing drug-eluting vs. bare metal stents in coronary artery disease: a meta-analysis. Eur Heart J 27:2784–2814PubMedCrossRef Nordmann AJ, Briel M, Bucher HC (2006) Mortality in randomized controlled trials comparing drug-eluting vs. bare metal stents in coronary artery disease: a meta-analysis. Eur Heart J 27:2784–2814PubMedCrossRef
2.
go back to reference Stone GW, Moses JW, Ellis SG et al (2007) Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents. N Engl J Med 356:998–1008PubMedCrossRef Stone GW, Moses JW, Ellis SG et al (2007) Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents. N Engl J Med 356:998–1008PubMedCrossRef
3.
go back to reference Lagerqvist B, James SK, Stenestrand U et al (2007) Long-term outcomes with drug-eluting stents versus bare-metal stents in Sweden. N Engl J Med 356:1009–1019PubMedCrossRef Lagerqvist B, James SK, Stenestrand U et al (2007) Long-term outcomes with drug-eluting stents versus bare-metal stents in Sweden. N Engl J Med 356:1009–1019PubMedCrossRef
4.
go back to reference Camenzind E, Steg PG, Wijns W (2007) Stent thrombosis late after implantation of first generation drug-eluting stents: a cause for concern. Circulation 115:1440–1455PubMedCrossRef Camenzind E, Steg PG, Wijns W (2007) Stent thrombosis late after implantation of first generation drug-eluting stents: a cause for concern. Circulation 115:1440–1455PubMedCrossRef
5.
go back to reference Finn AV, Joner M, Nakazawa G et al (2007) Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115:2435–2441PubMedCrossRef Finn AV, Joner M, Nakazawa G et al (2007) Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115:2435–2441PubMedCrossRef
6.
go back to reference Windecker S, Simon R, Lins M et al (2005) Randomized comparison of a titanium-nitride-oxide-coated stent with a stainless steel stent for coronary revascularization The TiNOX trial. Circulation 111:2617–2622PubMedCrossRef Windecker S, Simon R, Lins M et al (2005) Randomized comparison of a titanium-nitride-oxide-coated stent with a stainless steel stent for coronary revascularization The TiNOX trial. Circulation 111:2617–2622PubMedCrossRef
7.
go back to reference Mosseri M, Miller H, Tamari I et al (2006) The titanium-NO stent: results of a multicenter registry. Eurointervention 2:192–196PubMed Mosseri M, Miller H, Tamari I et al (2006) The titanium-NO stent: results of a multicenter registry. Eurointervention 2:192–196PubMed
8.
go back to reference Giraud-Sauveur Y (2007) Titan 2 bio-active stent (BAS) with titanium-NO. Eurointervention 3:526–528CrossRef Giraud-Sauveur Y (2007) Titan 2 bio-active stent (BAS) with titanium-NO. Eurointervention 3:526–528CrossRef
9.
go back to reference Karjalainen PP, Ylitalo A, Airaksinen JKE (2006) Real world experience with the TITAN stent: a 9-month follow-up report from the Titan PORI registry. Eurointervention 2:187–191PubMed Karjalainen PP, Ylitalo A, Airaksinen JKE (2006) Real world experience with the TITAN stent: a 9-month follow-up report from the Titan PORI registry. Eurointervention 2:187–191PubMed
10.
go back to reference Karjalainen PP, Annala A-P, Ylitalo A, Vahlberg T, Airaksinen KE (2010) Long-term clinical outcome with titanium-nitride-oxide-coated stents and paclitaxel-eluting stents for coronary revascularization in an unselected population. Int J Cardiol 114:42–46CrossRef Karjalainen PP, Annala A-P, Ylitalo A, Vahlberg T, Airaksinen KE (2010) Long-term clinical outcome with titanium-nitride-oxide-coated stents and paclitaxel-eluting stents for coronary revascularization in an unselected population. Int J Cardiol 114:42–46CrossRef
11.
go back to reference Karjalainen PP, Ylitalo A, Niemelä M et al (2008) Titanium-nitride-oxide coated stents versus paclitaxel-eluting stents in acute myocardial infarction: a 12-month follow-up report from the TITAX AMI trial. Eurointervention 4:232–241CrossRef Karjalainen PP, Ylitalo A, Niemelä M et al (2008) Titanium-nitride-oxide coated stents versus paclitaxel-eluting stents in acute myocardial infarction: a 12-month follow-up report from the TITAX AMI trial. Eurointervention 4:232–241CrossRef
12.
go back to reference Karjalainen PP, Ylitalo A, Niemelä M et al (2009) Two-year follow-up after percutaneous coronary intervention with titanium-nitride-oxide-coated stents versus paclitaxel-eluting stents in acute myocardial infarction. Ann Med 41:599–607PubMedCrossRef Karjalainen PP, Ylitalo A, Niemelä M et al (2009) Two-year follow-up after percutaneous coronary intervention with titanium-nitride-oxide-coated stents versus paclitaxel-eluting stents in acute myocardial infarction. Ann Med 41:599–607PubMedCrossRef
13.
go back to reference Bezerra HG, Costa MA, Guagliumi G, Rollins AM, Simon DI (2009) Intracoronary optical coherence tomography: a comprehensive review. Clinical and research applications. JACC Cardiovasc Interv 2:1035–1046PubMedCrossRef Bezerra HG, Costa MA, Guagliumi G, Rollins AM, Simon DI (2009) Intracoronary optical coherence tomography: a comprehensive review. Clinical and research applications. JACC Cardiovasc Interv 2:1035–1046PubMedCrossRef
14.
go back to reference Fan C, Kim J-S, Lee JM et al (2010) Different vascular healing patterns with various drug-eluting stents in primary percutaneous coronary intervention for ST-segment elevation myocardial infarction: optical coherence tomographic findings. Am J Cardiol 105:972–976PubMedCrossRef Fan C, Kim J-S, Lee JM et al (2010) Different vascular healing patterns with various drug-eluting stents in primary percutaneous coronary intervention for ST-segment elevation myocardial infarction: optical coherence tomographic findings. Am J Cardiol 105:972–976PubMedCrossRef
15.
go back to reference Kim J-S, Fan C, Choi D, Jang I-K, Lee JM, Kim TH et al (2009) Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study. Int J Cardiol. doi:10.1016/j.ijcard.2009.07.012 Kim J-S, Fan C, Choi D, Jang I-K, Lee JM, Kim TH et al (2009) Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study. Int J Cardiol. doi:10.​1016/​j.​ijcard.​2009.​07.​012
16.
go back to reference Guagliumi G, Musumeci G, Sirbu V et al (2010) Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents. JACC Cardiovasc Interv 3:521–529 Guagliumi G, Musumeci G, Sirbu V et al (2010) Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents. JACC Cardiovasc Interv 3:521–529
17.
go back to reference Miyoshi N, Shite J, Sinke T et al (2010) Comparison by optical coherence tomography of paclitaxel-eluting stents with sirolimus-eluting stents implanted in one coronary artery in one procedure; 6-month follow-up. Circ J 74:903–908PubMedCrossRef Miyoshi N, Shite J, Sinke T et al (2010) Comparison by optical coherence tomography of paclitaxel-eluting stents with sirolimus-eluting stents implanted in one coronary artery in one procedure; 6-month follow-up. Circ J 74:903–908PubMedCrossRef
18.
go back to reference Motreff P, Souteyrand G, Levesque S et al (2009) Comparative analysis of neointimal coverage with paclitaxel and zotarolimus drug-eluting stents, using optical coherence tomography 6 months after implantation. Arch Cardiovasc Dis 102:617–624PubMedCrossRef Motreff P, Souteyrand G, Levesque S et al (2009) Comparative analysis of neointimal coverage with paclitaxel and zotarolimus drug-eluting stents, using optical coherence tomography 6 months after implantation. Arch Cardiovasc Dis 102:617–624PubMedCrossRef
19.
go back to reference Kim J-S, Kim J-S, Kim TH et al (2010) Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxel-eluting stents using optical coherence tomography at 9 months after implantation. Circ J 74:320–326PubMedCrossRef Kim J-S, Kim J-S, Kim TH et al (2010) Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxel-eluting stents using optical coherence tomography at 9 months after implantation. Circ J 74:320–326PubMedCrossRef
20.
go back to reference Guagliumi G, Costa MA, Sirbu V et al (2011) Strut coverage and late malapposition with paclitaxel-eluting stents compared with bare metal stents in acute myocardial infarction: optical coherence tomography substudy of the Harmonizing outcomes with revascularization and stents in acute myocardial infarction (HORIZONS-AMI) trial. Circulation 123:274–281PubMedCrossRef Guagliumi G, Costa MA, Sirbu V et al (2011) Strut coverage and late malapposition with paclitaxel-eluting stents compared with bare metal stents in acute myocardial infarction: optical coherence tomography substudy of the Harmonizing outcomes with revascularization and stents in acute myocardial infarction (HORIZONS-AMI) trial. Circulation 123:274–281PubMedCrossRef
21.
go back to reference Räber L, Garcia Garcia HM, Baumgartner S, et al (2011) Vascular healing response five years after implantation of first generation DES: the SIRTAX LATE optical coherence study. Abstr Eurointerv 7(Suppl M):194 Räber L, Garcia Garcia HM, Baumgartner S, et al (2011) Vascular healing response five years after implantation of first generation DES: the SIRTAX LATE optical coherence study. Abstr Eurointerv 7(Suppl M):194
22.
go back to reference Kim J-S, Hong M-K, Fan C et al (2010) Intracoronary thrombus formation after drug-eluting stents implantation: optical coherence tomographic study. Am Heart J 159:278–283PubMedCrossRef Kim J-S, Hong M-K, Fan C et al (2010) Intracoronary thrombus formation after drug-eluting stents implantation: optical coherence tomographic study. Am Heart J 159:278–283PubMedCrossRef
Metadata
Title
Stent strut coverage of titanium-nitride-oxide coated stent compared to paclitaxel-eluting stent in acute myocardial infarction: TITAX-OCT study
Authors
Tuomas Lehtinen
K. E. Juhani Airaksinen
Antti Ylitalo
Pasi P. Karjalainen
Publication date
01-12-2012
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 8/2012
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-012-0032-6

Other articles of this Issue 8/2012

The International Journal of Cardiovascular Imaging 8/2012 Go to the issue