Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 8/2012

01-12-2012 | Original Paper

Aortic annulus dimension assessment by computed tomography for transcatheter aortic valve implantation: differences between systole and diastole

Authors: Angela G. Bertaso, Dennis T. L. Wong, Gary Y. H. Liew, Michael S. Cunnington, James D. Richardson, Viji S. Thomson, Brett Lorraine, George Kourlis, Diana Leech, Matthew I. Worthley, Stephen G. Worthley

Published in: The International Journal of Cardiovascular Imaging | Issue 8/2012

Login to get access

Abstract

Accurate assessment of aortic annular dimensions is essential for successful transcatheter aortic valve implantation (TAVI). Annular dimensions are conventionally measured in mid-systole by multidetector computed tomography (MDCT), echocardiography and angiography. Significant differences in systolic and diastolic aortic annular dimensions have been demonstrated in cohorts without aortic stenosis (AS), but it is unknown whether similar dynamic variation in annular dimensions exists in patients with severe calcific AS in whom aortic compliance is likely to be substantially reduced. We investigated the variation in aortic annular dimensions between systole and diastole in patients with severe calcific AS. Patients with severe calcific AS referred for TAVI were evaluated by 128-slice MDCT. Aortic annular diameter was measured during diastole and systole in the modified coronal, modified sagittal, and basal ring planes (maximal, minimal and mean diameters). Differences between systole and diastole were analysed by paired t test. Fifty-nine patients were included in the analysis. Three of the five aortic dimensions measured increased significantly during systole. The largest change was a 0.75 mm (3.4%) mean increase in the minimal diameter of the basal ring during systole (p = 0.004). This corresponds closely to the modified sagittal view, which also increased by mean 0.42 mm (1.9%) during systole (p = 0.008). There was no significant change in the maximal diameter of the basal ring or the modified coronal view during systole (p > 0.05). There is a small magnitude but statistically significant difference in aortic annulus dimensions of patients with severe AS referred for TAVI when measured in diastole and systole. This small difference is unlikely to alter clinical decisions regarding prosthesis size or suitability for TAVI.
Literature
1.
go back to reference Messika-Zeitoun D, Serfaty JM, Brochet E, Ducrocq G, Lepage L, Detaint D, Hyafil F, Himbert D, Pasi N, Laissy JP, Iung B, Vahanian A (2010) Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation. J Am Coll Cardiol 55(3):186–194. doi:10.1016/j.jacc.2009.06.063 PubMedCrossRef Messika-Zeitoun D, Serfaty JM, Brochet E, Ducrocq G, Lepage L, Detaint D, Hyafil F, Himbert D, Pasi N, Laissy JP, Iung B, Vahanian A (2010) Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation. J Am Coll Cardiol 55(3):186–194. doi:10.​1016/​j.​jacc.​2009.​06.​063 PubMedCrossRef
3.
go back to reference de Heer LM, Budde RP, Mali WP, de Vos AM, van Herwerden LA, Kluin J (2011) Aortic root dimension changes during systole and diastole: evaluation with ECG-gated multidetector row computed tomography. Int J Cardiovasc Imaging. doi:10.1007/s10554-011-9838-x de Heer LM, Budde RP, Mali WP, de Vos AM, van Herwerden LA, Kluin J (2011) Aortic root dimension changes during systole and diastole: evaluation with ECG-gated multidetector row computed tomography. Int J Cardiovasc Imaging. doi:10.​1007/​s10554-011-9838-x
4.
go back to reference Yankah AC, Klose H, Musci M, Siniawski H, Hetzer R (2001) Geometric mismatch between homograft (allograft) and native aortic root: a 14-year clinical experience. Eur J Cardiothorac Surg 20(4):835–841PubMedCrossRef Yankah AC, Klose H, Musci M, Siniawski H, Hetzer R (2001) Geometric mismatch between homograft (allograft) and native aortic root: a 14-year clinical experience. Eur J Cardiothorac Surg 20(4):835–841PubMedCrossRef
5.
go back to reference Dagum P, Green GR, Nistal FJ, Daughters GT, Timek TA, Foppiano LE, Bolger AF, Ingels NB Jr, Miller DC (1999) Deformational dynamics of the aortic root: modes and physiologic determinants. Circulation 100(19 Suppl):II54–II62PubMed Dagum P, Green GR, Nistal FJ, Daughters GT, Timek TA, Foppiano LE, Bolger AF, Ingels NB Jr, Miller DC (1999) Deformational dynamics of the aortic root: modes and physiologic determinants. Circulation 100(19 Suppl):II54–II62PubMed
6.
go back to reference Lansac E, Lim HS, Shomura Y, Lim KH, Rice NT, Goetz W, Acar C, Duran CMG (2002) A four-dimensional study of the aortic root dynamics. Eur J Cardiothorac Surg 22:497–503 Lansac E, Lim HS, Shomura Y, Lim KH, Rice NT, Goetz W, Acar C, Duran CMG (2002) A four-dimensional study of the aortic root dynamics. Eur J Cardiothorac Surg 22:497–503
7.
go back to reference Baumgartner H, Hung J, Bermejo J, Chambers JB, Evangelista A, Griffin BP, Iung B, Otto CM, Pellikka PA, Quinones M (2009) Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice. J Am Soc Echocardiogr 22(1):1–23; quiz 101–102. doi:10.1016/j.echo.2008.11.029 Baumgartner H, Hung J, Bermejo J, Chambers JB, Evangelista A, Griffin BP, Iung B, Otto CM, Pellikka PA, Quinones M (2009) Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice. J Am Soc Echocardiogr 22(1):1–23; quiz 101–102. doi:10.​1016/​j.​echo.​2008.​11.​029
8.
go back to reference Kurra V, Kapadia SR, Tuzcu EM, Halliburton SS, Svensson L, Roselli EE, Schoenhagen P (2010) Pre-procedural imaging of aortic root orientation and dimensions: comparison between X-ray angiographic planar imaging and 3-dimensional multidetector row computed tomography. JACC Cardiovasc Interv 3(1):105–113. doi:10.1016/j.jcin.2009.10.014 PubMedCrossRef Kurra V, Kapadia SR, Tuzcu EM, Halliburton SS, Svensson L, Roselli EE, Schoenhagen P (2010) Pre-procedural imaging of aortic root orientation and dimensions: comparison between X-ray angiographic planar imaging and 3-dimensional multidetector row computed tomography. JACC Cardiovasc Interv 3(1):105–113. doi:10.​1016/​j.​jcin.​2009.​10.​014 PubMedCrossRef
9.
go back to reference Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA, Picard MH, Roman MJ, Seward J, Shanewise JS, Solomon SD, Spencer KT, Sutton MS, Stewart WJ (2005) Recommendations for chamber quantification: a report from the American Society of Echocardiography’s Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr 18(12):1440–1463. doi:10.1016/j.echo.2005.10.005 PubMedCrossRef Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA, Picard MH, Roman MJ, Seward J, Shanewise JS, Solomon SD, Spencer KT, Sutton MS, Stewart WJ (2005) Recommendations for chamber quantification: a report from the American Society of Echocardiography’s Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr 18(12):1440–1463. doi:10.​1016/​j.​echo.​2005.​10.​005 PubMedCrossRef
10.
go back to reference Tops LF, Wood DA, Delgado V, Schuijf JD, Mayo JR, Pasupati S, Lamers FP, van der Wall EE, Schalij MJ, Webb JG, Bax JJ (2008) Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. JACC Cardiovasc Imaging 1(3):321–330. doi:10.1016/j.jcmg.2007.12.006 PubMedCrossRef Tops LF, Wood DA, Delgado V, Schuijf JD, Mayo JR, Pasupati S, Lamers FP, van der Wall EE, Schalij MJ, Webb JG, Bax JJ (2008) Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. JACC Cardiovasc Imaging 1(3):321–330. doi:10.​1016/​j.​jcmg.​2007.​12.​006 PubMedCrossRef
11.
go back to reference Ng AC, Delgado V, van der Kley F, Shanks M, van de Veire NR, Bertini M, Nucifora G, van Bommel RJ, Tops LF, de Weger A, Tavilla G, de Roos A, Kroft LJ, Leung DY, Schuijf J, Schalij MJ, Bax JJ (2010) Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography. Circ Cardiovasc Imaging 3(1):94–102. doi:10.1161/CIRCIMAGING.109.885152 PubMedCrossRef Ng AC, Delgado V, van der Kley F, Shanks M, van de Veire NR, Bertini M, Nucifora G, van Bommel RJ, Tops LF, de Weger A, Tavilla G, de Roos A, Kroft LJ, Leung DY, Schuijf J, Schalij MJ, Bax JJ (2010) Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography. Circ Cardiovasc Imaging 3(1):94–102. doi:10.​1161/​CIRCIMAGING.​109.​885152 PubMedCrossRef
12.
go back to reference Wood DA, Tops LF, Mayo JR, Pasupati S, Schalij MJ, Humphries K, Lee M, Al Ali A, Munt B, Moss R, Thompson CR, Bax JJ, Webb JG (2009) Role of multislice computed tomography in transcatheter aortic valve replacement. Am J Cardiol 103(9):1295–1301. doi:10.1016/j.amjcard.2009.01.034 PubMedCrossRef Wood DA, Tops LF, Mayo JR, Pasupati S, Schalij MJ, Humphries K, Lee M, Al Ali A, Munt B, Moss R, Thompson CR, Bax JJ, Webb JG (2009) Role of multislice computed tomography in transcatheter aortic valve replacement. Am J Cardiol 103(9):1295–1301. doi:10.​1016/​j.​amjcard.​2009.​01.​034 PubMedCrossRef
13.
go back to reference Kazui T, Izumoto H, Yoshioka K, Kawazoe K (2006) Dynamic morphologic changes in the normal aortic annulus during systole and diastole. J Heart Valve Dis 15(5):617–621PubMed Kazui T, Izumoto H, Yoshioka K, Kawazoe K (2006) Dynamic morphologic changes in the normal aortic annulus during systole and diastole. J Heart Valve Dis 15(5):617–621PubMed
14.
go back to reference Grande KJ, Cochran RP, Reinhall PG, Kunzelman KS (1999) Mechanisms of aortic valve incompetence in aging: a finite element model. J Heart Valve Dis 8(2):149–156PubMed Grande KJ, Cochran RP, Reinhall PG, Kunzelman KS (1999) Mechanisms of aortic valve incompetence in aging: a finite element model. J Heart Valve Dis 8(2):149–156PubMed
16.
go back to reference Nelson AJ, Worthley SG, Cameron JD, Willoughby SR, Piantadosi C, Carbone A, Dundon BK, Leung MC, Hope SA, Meredith IT, Worthley MI (2009) Cardiovascular magnetic resonance-derived aortic distensibility: validation and observed regional differences in the elderly. J Hypertens 27(3):535–542PubMedCrossRef Nelson AJ, Worthley SG, Cameron JD, Willoughby SR, Piantadosi C, Carbone A, Dundon BK, Leung MC, Hope SA, Meredith IT, Worthley MI (2009) Cardiovascular magnetic resonance-derived aortic distensibility: validation and observed regional differences in the elderly. J Hypertens 27(3):535–542PubMedCrossRef
Metadata
Title
Aortic annulus dimension assessment by computed tomography for transcatheter aortic valve implantation: differences between systole and diastole
Authors
Angela G. Bertaso
Dennis T. L. Wong
Gary Y. H. Liew
Michael S. Cunnington
James D. Richardson
Viji S. Thomson
Brett Lorraine
George Kourlis
Diana Leech
Matthew I. Worthley
Stephen G. Worthley
Publication date
01-12-2012
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 8/2012
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-012-0018-4

Other articles of this Issue 8/2012

The International Journal of Cardiovascular Imaging 8/2012 Go to the issue