Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 4/2012

01-04-2012 | Original Paper

Optical coherence tomography findings of very late stent thrombosis after drug-eluting stent implantation

Authors: Young-Guk Ko, Dong-Min Kim, Jin Man Cho, So Yeon Choi, Jung Han Yoon, Jung-Sun Kim, Byeong-Keuk Kim, Donghoon Choi, Yangsoo Jang, Myeong-Ki Hong

Published in: The International Journal of Cardiovascular Imaging | Issue 4/2012

Login to get access

Abstract

Previous optical coherence tomography (OCT) studies in patients with drug-eluting stents (DESs)-related very late stent thrombosis (VLST) were scarce. Therefore, we investigated OCT findings of VLST after implantation of DESs. Using OCT, we analyzed the status of stent struts and neointimal characteristics in 18 patients who developed VLST after DES implantation. These results were compared to those in 57 patients with neointimal hyperplasia causing >40% diameter stenosis. Lipid-laden neointima was defined as a region with marked signal attenuation and a diffuse border. Four (22.2%) of 18 patients with VLST had ruptured and lipid-laden neointima inside DESs without uncovered or malapposed stent struts. In the remaining 14 patients who developed VLST without neointimal rupture, uncovered and malapposed struts were observed in nine and seven patients, respectively, and lipid-laden neointima in four patients. Lipid-laden neointima was more frequently observed in four patients with neointimal rupture than in 14 patients without neointimal rupture (100% vs. 28.6%, respectively, P = 0.023). Of 57 patients with neointimal hyperplasia, eight (14.0%) had lipid-laden neointima. Time to OCT study after DES implantation was significantly longer in the eight patients with lipid-laden neointima than in 49 patients without lipid-laden neointima (45.5 ± 17.7 months vs. 11.7 ± 7.2 months, respectively, P < 0.001). Lipid-laden neointima was detected in some patients with neointimal hyperplasia > 1 year after DES implantation. In addition to uncovered or malapposed struts, rupture of lipid-laden neointima inside DESs was identified in some patients with DES-related VLST.
Literature
1.
go back to reference Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O’Shaughnessy C, Caputo RP, Kereiakes DJ, Williams DO, Teirstein PS, Jaeger JL, Kuntz RE (2003) Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 349(14):1315–1323PubMedCrossRef Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O’Shaughnessy C, Caputo RP, Kereiakes DJ, Williams DO, Teirstein PS, Jaeger JL, Kuntz RE (2003) Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 349(14):1315–1323PubMedCrossRef
2.
go back to reference Stone GW, Ellis SG, Cox DA, Hermiller J, O’Shaughnessy C, Mann JT, Turco M, Caputo R, Bergin P, Greenberg J, Popma JJ, Russell ME (2004) A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 350(3):221–231PubMedCrossRef Stone GW, Ellis SG, Cox DA, Hermiller J, O’Shaughnessy C, Mann JT, Turco M, Caputo R, Bergin P, Greenberg J, Popma JJ, Russell ME (2004) A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 350(3):221–231PubMedCrossRef
3.
go back to reference Camenzind E, Steg PG, Wijns W (2007) Stent thrombosis late after implantation of first-generation drug-eluting stents: a cause for concern. Circulation 115(11):1440–1455PubMedCrossRef Camenzind E, Steg PG, Wijns W (2007) Stent thrombosis late after implantation of first-generation drug-eluting stents: a cause for concern. Circulation 115(11):1440–1455PubMedCrossRef
4.
go back to reference Nordmann AJ, Briel M, Bucher HC (2006) Mortality in randomized controlled trials comparing drug-eluting versus bare metal stents in coronary artery disease: a meta-analysis. Euro Heart J 27(23):2784–2814CrossRef Nordmann AJ, Briel M, Bucher HC (2006) Mortality in randomized controlled trials comparing drug-eluting versus bare metal stents in coronary artery disease: a meta-analysis. Euro Heart J 27(23):2784–2814CrossRef
5.
go back to reference Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Gold HK, Virmani R (2007) Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115(18):2435–2441PubMedCrossRef Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Gold HK, Virmani R (2007) Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115(18):2435–2441PubMedCrossRef
6.
go back to reference Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, Kutys R, Skorija K, Gold HK, Virmani R (2006) Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol 48(1):193–202PubMedCrossRef Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, Kutys R, Skorija K, Gold HK, Virmani R (2006) Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol 48(1):193–202PubMedCrossRef
7.
go back to reference Farb A, Burke AP, Kolodgie FD, Virmani R (2003) Pathological mechanisms of fatal late coronary stent thrombosis in humans. Circulation 108(14):1701–1706PubMedCrossRef Farb A, Burke AP, Kolodgie FD, Virmani R (2003) Pathological mechanisms of fatal late coronary stent thrombosis in humans. Circulation 108(14):1701–1706PubMedCrossRef
8.
go back to reference Bezerra HG, Costa MA, Guagliumi G, Rollins AM, Simon DI (2009) Intracoronary optical coherence tomography: a comprehensive review clinical and research applications. JACC Cardiovasc Interv 2(11):1035–1046PubMedCrossRef Bezerra HG, Costa MA, Guagliumi G, Rollins AM, Simon DI (2009) Intracoronary optical coherence tomography: a comprehensive review clinical and research applications. JACC Cardiovasc Interv 2(11):1035–1046PubMedCrossRef
9.
go back to reference Hou J, Qi H, Zhang M, Ma L, Liu H, Han Z, Meng L, Yang S, Zhang S, Yu B, Jang IK (2010) Development of lipid-rich plaque inside bare metal stent: possible mechanism of late stent thrombosis? an optical coherence tomography study. Heart 96:1187–1190PubMedCrossRef Hou J, Qi H, Zhang M, Ma L, Liu H, Han Z, Meng L, Yang S, Zhang S, Yu B, Jang IK (2010) Development of lipid-rich plaque inside bare metal stent: possible mechanism of late stent thrombosis? an optical coherence tomography study. Heart 96:1187–1190PubMedCrossRef
10.
go back to reference Takano M, Yamamoto M, Inami S, Murakami D, Ohba T, Seino Y, Mizuno K (2009) Appearance of lipid-laden intima and neovascularization after implantation of bare-metal stents extended late-phase observation by intracoronary optical coherence tomography. J Am Coll Cardiol 55:26–32PubMedCrossRef Takano M, Yamamoto M, Inami S, Murakami D, Ohba T, Seino Y, Mizuno K (2009) Appearance of lipid-laden intima and neovascularization after implantation of bare-metal stents extended late-phase observation by intracoronary optical coherence tomography. J Am Coll Cardiol 55:26–32PubMedCrossRef
11.
go back to reference Lee CW, Kang SJ, Park DW, Lee SH, Kim YH, Kim JJ, Park SW, Mintz GS, Park SJ (2010) Intravascular ultrasound findings in patients with very late stent thrombosis after either drug-eluting or bare-metal stent implantation. J Am Coll Cardiol 55:1936–1942PubMedCrossRef Lee CW, Kang SJ, Park DW, Lee SH, Kim YH, Kim JJ, Park SW, Mintz GS, Park SJ (2010) Intravascular ultrasound findings in patients with very late stent thrombosis after either drug-eluting or bare-metal stent implantation. J Am Coll Cardiol 55:1936–1942PubMedCrossRef
12.
go back to reference Cutlip DE, Windecker S, Mehran R, Boam A, Cohen DJ, van Es GA, Steg PG, Morel MA, Mauri L, Vranckx P, McFadden E, Lansky A, Hamon M, Krucoff MW, Serruys PW (2007) Clinical end points in coronary stent trials: a case for standardized definitions. Circulation 115:2344–2351PubMedCrossRef Cutlip DE, Windecker S, Mehran R, Boam A, Cohen DJ, van Es GA, Steg PG, Morel MA, Mauri L, Vranckx P, McFadden E, Lansky A, Hamon M, Krucoff MW, Serruys PW (2007) Clinical end points in coronary stent trials: a case for standardized definitions. Circulation 115:2344–2351PubMedCrossRef
13.
go back to reference Kim U, Kim JS, Lee JM, Son JW, Kim J, Ko YG, Choi D, Jang Y (2010) The initial extent of malapposition in ST-elevation myocardial infarction treated with drug-eluting stent: the usefulness of optical coherence tomography. Yonsei Med J 51:332–338PubMedCrossRef Kim U, Kim JS, Lee JM, Son JW, Kim J, Ko YG, Choi D, Jang Y (2010) The initial extent of malapposition in ST-elevation myocardial infarction treated with drug-eluting stent: the usefulness of optical coherence tomography. Yonsei Med J 51:332–338PubMedCrossRef
14.
go back to reference Kim JS, Hong MK, Fan C, Kim TH, Shim JM, Park SM, Ko YG, Choi D, Jang Y (2010) Intracoronary thrombus formation after drug-eluting stents implantation: Optical coherence tomographic study. Am Heart J 159:278–283PubMedCrossRef Kim JS, Hong MK, Fan C, Kim TH, Shim JM, Park SM, Ko YG, Choi D, Jang Y (2010) Intracoronary thrombus formation after drug-eluting stents implantation: Optical coherence tomographic study. Am Heart J 159:278–283PubMedCrossRef
15.
go back to reference Takano M, Inami S, Jang IK, Yamamoto M, Murakami D, Seimiya K, Ohba T, Mizuno K (2007) Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent 3 months after implantation. Am J Cardiol 99:1033–1038PubMedCrossRef Takano M, Inami S, Jang IK, Yamamoto M, Murakami D, Seimiya K, Ohba T, Mizuno K (2007) Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent 3 months after implantation. Am J Cardiol 99:1033–1038PubMedCrossRef
16.
go back to reference Tanigawa J, Barlis P, Dimopoulos K, Dalby M, Moore P, Di Mario C (2008) The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography. Int J Cardiol 134:180–188PubMedCrossRef Tanigawa J, Barlis P, Dimopoulos K, Dalby M, Moore P, Di Mario C (2008) The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography. Int J Cardiol 134:180–188PubMedCrossRef
17.
go back to reference Kume T, Akasaka T, Kawamoto T, Ogasawara Y, Watanabe N, Toyota E, Neishi Y, Sukmawan R, Sadahira Y, Yoshida K (2006) Assessment of coronary arterial thrombus by optical coherence tomography. Am J Cardiol 97:1713–1717PubMedCrossRef Kume T, Akasaka T, Kawamoto T, Ogasawara Y, Watanabe N, Toyota E, Neishi Y, Sukmawan R, Sadahira Y, Yoshida K (2006) Assessment of coronary arterial thrombus by optical coherence tomography. Am J Cardiol 97:1713–1717PubMedCrossRef
18.
go back to reference Kwon SW, Kim BK, Kim TH, Kim JS, Ko YG, Choi D, Jang Y, Hong MK (2011) Qualitative assessment of neointimal tissue after drug-eluting stent implantation: comparison between follow-up optical coherence tomography and intravascular ultrasound. Am Heart J 161:367–372PubMedCrossRef Kwon SW, Kim BK, Kim TH, Kim JS, Ko YG, Choi D, Jang Y, Hong MK (2011) Qualitative assessment of neointimal tissue after drug-eluting stent implantation: comparison between follow-up optical coherence tomography and intravascular ultrasound. Am Heart J 161:367–372PubMedCrossRef
19.
go back to reference Stettler C, Wandel S, Allemann S, Kastrati A, Morice MC, Schomig A, Pfisterer ME, Stone GW, Leon MB, de Lezo JS, Goy JJ, Park SJ, Sabate M, Suttorp MJ, Kelbaek H, Spaulding C, Menichelli M, Vermeersch P, Dirksen MT, Cervinka P, Petronio AS, Nordmann AJ, Diem P, Meier B, Zwahlen M, Reichenbach S, Trelle S, Windecker S, Juni P (2007) Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis. Lancet 370:937–948PubMedCrossRef Stettler C, Wandel S, Allemann S, Kastrati A, Morice MC, Schomig A, Pfisterer ME, Stone GW, Leon MB, de Lezo JS, Goy JJ, Park SJ, Sabate M, Suttorp MJ, Kelbaek H, Spaulding C, Menichelli M, Vermeersch P, Dirksen MT, Cervinka P, Petronio AS, Nordmann AJ, Diem P, Meier B, Zwahlen M, Reichenbach S, Trelle S, Windecker S, Juni P (2007) Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis. Lancet 370:937–948PubMedCrossRef
20.
go back to reference Spaulding C, Daemen J, Boersma E, Cutlip DE, Serruys PW (2007) A pooled analysis of data comparing sirolimus-eluting stents with bare-metal stents. N Engl J Med 356:989–997PubMedCrossRef Spaulding C, Daemen J, Boersma E, Cutlip DE, Serruys PW (2007) A pooled analysis of data comparing sirolimus-eluting stents with bare-metal stents. N Engl J Med 356:989–997PubMedCrossRef
21.
go back to reference Stone GW, Moses JW, Ellis SG, Schofer J, Dawkins KD, Morice MC, Colombo A, Schampaert E, Grube E, Kirtane AJ, Cutlip DE, Fahy M, Pocock SJ, Mehran R, Leon MB (2007) Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents. N Engl J Med 356:998–1008PubMedCrossRef Stone GW, Moses JW, Ellis SG, Schofer J, Dawkins KD, Morice MC, Colombo A, Schampaert E, Grube E, Kirtane AJ, Cutlip DE, Fahy M, Pocock SJ, Mehran R, Leon MB (2007) Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents. N Engl J Med 356:998–1008PubMedCrossRef
22.
go back to reference Serruys PW, Daemen J (2007) Are drug-eluting stents associated with a higher rate of late thrombosis than bare metal stents? Late stent thrombosis: a nuisance in both bare metal and drug-eluting stents. Circulation 115:1433–1439PubMedCrossRef Serruys PW, Daemen J (2007) Are drug-eluting stents associated with a higher rate of late thrombosis than bare metal stents? Late stent thrombosis: a nuisance in both bare metal and drug-eluting stents. Circulation 115:1433–1439PubMedCrossRef
23.
go back to reference Doyle B, Rihal CS, O’Sullivan CJ, Lennon RJ, Wiste HJ, Bell M, Bresnahan J, Holmes DR Jr (2007) Outcomes of stent thrombosis and restenosis during extended follow-up of patients treated with bare-metal coronary stents. Circulation 116:2391–2398PubMedCrossRef Doyle B, Rihal CS, O’Sullivan CJ, Lennon RJ, Wiste HJ, Bell M, Bresnahan J, Holmes DR Jr (2007) Outcomes of stent thrombosis and restenosis during extended follow-up of patients treated with bare-metal coronary stents. Circulation 116:2391–2398PubMedCrossRef
24.
go back to reference Finn AV, Nakazawa G, Joner M, Kolodgie FD, Mont EK, Gold HK, Virmani R (2007) Vascular responses to drug eluting stents: importance of delayed healing. Arterioscler Thromb Vasc Biol 27:1500–1510PubMedCrossRef Finn AV, Nakazawa G, Joner M, Kolodgie FD, Mont EK, Gold HK, Virmani R (2007) Vascular responses to drug eluting stents: importance of delayed healing. Arterioscler Thromb Vasc Biol 27:1500–1510PubMedCrossRef
25.
go back to reference Cook S, Wenaweser P, Togni M, Billinger M, Morger C, Seiler C, Vogel R, Hess O, Meier B, Windecker S (2007) Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. Circulation 115:2426–2434PubMedCrossRef Cook S, Wenaweser P, Togni M, Billinger M, Morger C, Seiler C, Vogel R, Hess O, Meier B, Windecker S (2007) Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. Circulation 115:2426–2434PubMedCrossRef
26.
go back to reference Hassan AK, Bergheanu SC, Stijnen T, van der Hoeven BL, Snoep JD, Plevier JW, Schalij MJ, Wouter Jukema J (2010) Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis. Eur Heart J 31:1172–1180PubMedCrossRef Hassan AK, Bergheanu SC, Stijnen T, van der Hoeven BL, Snoep JD, Plevier JW, Schalij MJ, Wouter Jukema J (2010) Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis. Eur Heart J 31:1172–1180PubMedCrossRef
27.
go back to reference Cook S, Ladich E, Nakazawa G, Eshtehardi P, Neidhart M, Vogel R, Togni M, Wenaweser P, Billinger M, Seiler C, Gay S, Meier B, Pichler WJ, Juni P, Virmani R, Windecker S (2009) Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis. Circulation 120:391–399PubMedCrossRef Cook S, Ladich E, Nakazawa G, Eshtehardi P, Neidhart M, Vogel R, Togni M, Wenaweser P, Billinger M, Seiler C, Gay S, Meier B, Pichler WJ, Juni P, Virmani R, Windecker S (2009) Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis. Circulation 120:391–399PubMedCrossRef
28.
go back to reference Matsumoto D, Shite J, Shinke T, Otake H, Tanino Y, Ogasawara D, Sawada T, Paredes OL, Hirata K, Yokoyama M (2007) Neointimal coverage of sirolimus-eluting stents at 6 month follow-up: evaluated by optical coherence tomography. Eur Heart J 28:961–967PubMedCrossRef Matsumoto D, Shite J, Shinke T, Otake H, Tanino Y, Ogasawara D, Sawada T, Paredes OL, Hirata K, Yokoyama M (2007) Neointimal coverage of sirolimus-eluting stents at 6 month follow-up: evaluated by optical coherence tomography. Eur Heart J 28:961–967PubMedCrossRef
29.
go back to reference Hasegawa K, Tamai H, Kyo E, Kosuga K, Ikeguchi S, Hata T, Okada M, Fujita S, Tsuji T, Takeda S, Fukuhara R, Kikuta Y, Motohara S, Ono K, Takeuchi E (2006) Histopathological findings of new in-stent lesions developed beyond 5 years. Catheter Cardiovasc Interv 68:554–558PubMedCrossRef Hasegawa K, Tamai H, Kyo E, Kosuga K, Ikeguchi S, Hata T, Okada M, Fujita S, Tsuji T, Takeda S, Fukuhara R, Kikuta Y, Motohara S, Ono K, Takeuchi E (2006) Histopathological findings of new in-stent lesions developed beyond 5 years. Catheter Cardiovasc Interv 68:554–558PubMedCrossRef
30.
go back to reference Nakazawa G, Vorpahl M, Finn AV, Narula J, Virmani R (2009) One step forward and two steps back with drug-eluting-stents: from preventing restenosis to causing late thrombosis and nouveau atherosclerosis. JACC: Cardiovascular Imaging 2:625–628PubMedCrossRef Nakazawa G, Vorpahl M, Finn AV, Narula J, Virmani R (2009) One step forward and two steps back with drug-eluting-stents: from preventing restenosis to causing late thrombosis and nouveau atherosclerosis. JACC: Cardiovascular Imaging 2:625–628PubMedCrossRef
31.
go back to reference Nakazawa G, Otsuka F, Nakano M, Vorpahl M, Yazdani SK, Ladich E, Kolodgie FD, Finn AV, Virmani R (2011) The pathology of neoatherosclerosis in human coronary implants bare-metal and drug-eluting stents. J Am Coll Cardiol 57(11):1314–1322PubMedCrossRef Nakazawa G, Otsuka F, Nakano M, Vorpahl M, Yazdani SK, Ladich E, Kolodgie FD, Finn AV, Virmani R (2011) The pathology of neoatherosclerosis in human coronary implants bare-metal and drug-eluting stents. J Am Coll Cardiol 57(11):1314–1322PubMedCrossRef
33.
go back to reference Prati F, Regar E, Mintz GS, Arbustini E, Di Mario C, Jang IK, Akasaka T, Costa M, Guagliumi G, Grube E, Ozaki Y, Pinto F, Serruys PW (2010) Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. Euro Heart J 31(4):401–415CrossRef Prati F, Regar E, Mintz GS, Arbustini E, Di Mario C, Jang IK, Akasaka T, Costa M, Guagliumi G, Grube E, Ozaki Y, Pinto F, Serruys PW (2010) Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. Euro Heart J 31(4):401–415CrossRef
Metadata
Title
Optical coherence tomography findings of very late stent thrombosis after drug-eluting stent implantation
Authors
Young-Guk Ko
Dong-Min Kim
Jin Man Cho
So Yeon Choi
Jung Han Yoon
Jung-Sun Kim
Byeong-Keuk Kim
Donghoon Choi
Yangsoo Jang
Myeong-Ki Hong
Publication date
01-04-2012
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 4/2012
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-011-9905-3

Other articles of this Issue 4/2012

The International Journal of Cardiovascular Imaging 4/2012 Go to the issue