Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 8/2009

01-12-2009 | Original Paper

Reproducibility and accuracy of automated measurement for dynamic arterial lumen area by cardiovascular magnetic resonance

Authors: Clare E. Jackson, Cheerag C. Shirodaria, Justin M. S. Lee, Jane M. Francis, Robin P. Choudhury, Keith M. Channon, J. Alison Noble, Stefan Neubauer, Matthew D. Robson

Published in: The International Journal of Cardiovascular Imaging | Issue 8/2009

Login to get access

Abstract

Bright blood cine images acquired using Magnetic Resonance Imaging contain simple contrast that is tractable to automated analysis, which can be used to derive a measure of arterial compliance that is known to correlate with disease severity. The purpose of this work was to evaluate whether automated methods could be used reliably on a clinically relevant population, and to assess the precision of these measurements so that it could be compared with expert manual assessment. In this paper we apply an algorithm similar to that used by Krug et al., and the exact processing steps are described in detail to allowing easy reproduction of our methods. Phantoms of different sizes have been assessed and the MRI measurements are found to correlate well (r = 0.9998) with physical measurement. Reproducibility assessment was performed on 33 CAD subjects in three anatomical locations along the aorta. Six normal volunteers and ten patients with more severe aortic plaques were investigated to assess reproducibility and sensitivity to pathological changes, respectively. The performance was also assessed on carotid vessels in 40 patients with known arterial plaques. In the human aorta the method is found to be robust (failing in only 7% of cases, all due to clear errors with image acquisition), and to be quantifiably consistent with expert clinical measurement, but showing smaller errors than that approach [<1.21% (5.62 mm2) manual vs. <0.58% (2.71 mm2) automated, for the aortic area] and with reduced bias, and operated correctly in advanced disease. We have proved over a large number of subjects the superiority of this automated method for evaluating dynamic area changes over the Gold-standard manual approach.
Appendix
Available only for authorised users
Literature
1.
go back to reference Corti R (2006) Noninvasive imaging of atherosclerotic vessels by MRI for clinical assessment of the effectiveness of therapy. Pharmacol Therapeut 110:57–70CrossRef Corti R (2006) Noninvasive imaging of atherosclerotic vessels by MRI for clinical assessment of the effectiveness of therapy. Pharmacol Therapeut 110:57–70CrossRef
2.
go back to reference Wiesmann F, Petersen SE, Leeson PM, Francis JM, Robson MD, Wang Q et al (2004) Global impairment of brachial, carotid, and aortic vascular function in young smokers: direct quantification by high-resolution magnetic resonance imaging. J Am Coll Cardiol 44:2056–2064CrossRefPubMed Wiesmann F, Petersen SE, Leeson PM, Francis JM, Robson MD, Wang Q et al (2004) Global impairment of brachial, carotid, and aortic vascular function in young smokers: direct quantification by high-resolution magnetic resonance imaging. J Am Coll Cardiol 44:2056–2064CrossRefPubMed
3.
go back to reference Lee JM, Shirodaria C, Jackson CE, Robson MD, Antoniades C, Francis JM et al (2007) Multi-modal magnetic resonance imaging quantifies atherosclerosis and vascular dysfunction in patients with type 2 diabetes mellitus. Diab Vasc Dis Res 4:44–48CrossRefPubMed Lee JM, Shirodaria C, Jackson CE, Robson MD, Antoniades C, Francis JM et al (2007) Multi-modal magnetic resonance imaging quantifies atherosclerosis and vascular dysfunction in patients with type 2 diabetes mellitus. Diab Vasc Dis Res 4:44–48CrossRefPubMed
4.
go back to reference Shirodaria C, Antoniades C, Lee J, Jackson CE, Robson MD, Francis JM et al (2007) Global improvement of vascular function and redox state with low-dose folic acid: implications for folate therapy in patients with coronary artery disease. Circulation 115(17):2262–2270 Shirodaria C, Antoniades C, Lee J, Jackson CE, Robson MD, Francis JM et al (2007) Global improvement of vascular function and redox state with low-dose folic acid: implications for folate therapy in patients with coronary artery disease. Circulation 115(17):2262–2270
5.
go back to reference Mattace-Raso FUS, van der Cammen TJM, Hofman A, van Popele NM, Bos ML, Schalekamp MADH et al (2006) Arterial stiffness and risk of coronary heart disease and stroke—the Rotterdam study. Circulation 113:657–663CrossRefPubMed Mattace-Raso FUS, van der Cammen TJM, Hofman A, van Popele NM, Bos ML, Schalekamp MADH et al (2006) Arterial stiffness and risk of coronary heart disease and stroke—the Rotterdam study. Circulation 113:657–663CrossRefPubMed
6.
go back to reference Yuan C, Lin E, Millard J, Hwang JN (1999) Closed contour edge detection of blood vessel lumen and outer wall boundaries in black-blood MR images. Magn Reson Imaging 17:257–266CrossRefPubMed Yuan C, Lin E, Millard J, Hwang JN (1999) Closed contour edge detection of blood vessel lumen and outer wall boundaries in black-blood MR images. Magn Reson Imaging 17:257–266CrossRefPubMed
7.
go back to reference Krug R, Boese JM, Schad LR (2003) Determination of aortic compliance from magnetic resonance images using an automatic active contour model. Phys Med Biol 48:2391–2404CrossRefPubMed Krug R, Boese JM, Schad LR (2003) Determination of aortic compliance from magnetic resonance images using an automatic active contour model. Phys Med Biol 48:2391–2404CrossRefPubMed
8.
go back to reference Monga O, Deriche R, Rocchisani JM (1991) 3d edge-detection using recursive filtering—application to scanner images. CVGIP-Image Underst 53:76–87CrossRef Monga O, Deriche R, Rocchisani JM (1991) 3d edge-detection using recursive filtering—application to scanner images. CVGIP-Image Underst 53:76–87CrossRef
9.
go back to reference Wang Q, Robson MD, Francis JM, Petersen SE, Channon KM, Neubauer S et al (2004) Accuracy of quantitative MR vessel wall imaging applying a semi-automated gradient detection algorithm—a validation study. J Cardiovasc Magn Reson 6:895–907CrossRefPubMed Wang Q, Robson MD, Francis JM, Petersen SE, Channon KM, Neubauer S et al (2004) Accuracy of quantitative MR vessel wall imaging applying a semi-automated gradient detection algorithm—a validation study. J Cardiovasc Magn Reson 6:895–907CrossRefPubMed
10.
go back to reference Glagov S, Weisenburg E, Zarins CK, Stankunvicius R, Kolettis GJ (1987) Compensatory enlargement of human atherosclerotic coronary arteries. The New Engl J Med 316:1371–1375 Glagov S, Weisenburg E, Zarins CK, Stankunvicius R, Kolettis GJ (1987) Compensatory enlargement of human atherosclerotic coronary arteries. The New Engl J Med 316:1371–1375
11.
go back to reference Rueckert D, Burger P, Forbat SM, Mohiaddin RD, Yang GZ (1997) Automatic tracking of the aorta in cardiovascular MR images using deformable models. IEEE Trans Med Imaging 16:581–590CrossRefPubMed Rueckert D, Burger P, Forbat SM, Mohiaddin RD, Yang GZ (1997) Automatic tracking of the aorta in cardiovascular MR images using deformable models. IEEE Trans Med Imaging 16:581–590CrossRefPubMed
12.
go back to reference Adame IM, van der Geest RJ, Bluemke DA, Lima JAC, Reiber JHC, Lelieveldt BPF (2006) Automatic vessel wall contour detection and quantification of wall thickness in in vivo MR images of the human aorta. J Magn Reson Imaging 24:595–602CrossRefPubMed Adame IM, van der Geest RJ, Bluemke DA, Lima JAC, Reiber JHC, Lelieveldt BPF (2006) Automatic vessel wall contour detection and quantification of wall thickness in in vivo MR images of the human aorta. J Magn Reson Imaging 24:595–602CrossRefPubMed
13.
go back to reference Liu F, Xu DX, Ferguson MS, Chu BC, Saam T, Takaya N et al (2006) Automated in vivo segmentation of carotid plaque MRI with morphology-enhanced probability maps. Magnet Reson Med 55:659–668CrossRef Liu F, Xu DX, Ferguson MS, Chu BC, Saam T, Takaya N et al (2006) Automated in vivo segmentation of carotid plaque MRI with morphology-enhanced probability maps. Magnet Reson Med 55:659–668CrossRef
14.
go back to reference Mansard CD, Canet Soulas EP, Anwander A, Chaabane L, Neyran B, Serfaty JM et al (2004) Quantification of multicontrast vascular MR images with NLSnake, an active contour model: in vitro validation and in vivo evaluation. Magn Reson Med 51:370–379CrossRefPubMed Mansard CD, Canet Soulas EP, Anwander A, Chaabane L, Neyran B, Serfaty JM et al (2004) Quantification of multicontrast vascular MR images with NLSnake, an active contour model: in vitro validation and in vivo evaluation. Magn Reson Med 51:370–379CrossRefPubMed
15.
go back to reference Kozerke S, Botnar R, Oyre S, Scheidegger MB, Pedersen EM, Boesiger P (1999) Automatic vessel segmentation using active contours in cine phase contrast flow measurements. J Magn Reson Imaging 10:41–51CrossRefPubMed Kozerke S, Botnar R, Oyre S, Scheidegger MB, Pedersen EM, Boesiger P (1999) Automatic vessel segmentation using active contours in cine phase contrast flow measurements. J Magn Reson Imaging 10:41–51CrossRefPubMed
16.
go back to reference Lorenzo-Valdes M, Sanchez-Ortiz GI, Bogren H, Mohiaddin R, Rueckert D (2004) Determination of aortic distensibility using non-rigid registration of Cine MR images. Medical Image Computing and Computer-Assisted Intervention—Miccai 2004, Pt 1. In: Proceedings 3216:754–762 Lorenzo-Valdes M, Sanchez-Ortiz GI, Bogren H, Mohiaddin R, Rueckert D (2004) Determination of aortic distensibility using non-rigid registration of Cine MR images. Medical Image Computing and Computer-Assisted Intervention—Miccai 2004, Pt 1. In: Proceedings 3216:754–762
17.
go back to reference Lalande A, Van Kien PK, Salve N, Ben Salem D, Legrand L, Walker PM et al (2002) Automatic determination of aortic compliance with cine-magnetic resonance imaging—an application of fuzzy logic theory. Invest Radiol 37:685–691CrossRefPubMed Lalande A, Van Kien PK, Salve N, Ben Salem D, Legrand L, Walker PM et al (2002) Automatic determination of aortic compliance with cine-magnetic resonance imaging—an application of fuzzy logic theory. Invest Radiol 37:685–691CrossRefPubMed
Metadata
Title
Reproducibility and accuracy of automated measurement for dynamic arterial lumen area by cardiovascular magnetic resonance
Authors
Clare E. Jackson
Cheerag C. Shirodaria
Justin M. S. Lee
Jane M. Francis
Robin P. Choudhury
Keith M. Channon
J. Alison Noble
Stefan Neubauer
Matthew D. Robson
Publication date
01-12-2009
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 8/2009
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-009-9495-5

Other articles of this Issue 8/2009