Skip to main content
Top
Published in: Magnetic Resonance Materials in Physics, Biology and Medicine 1/2014

01-02-2014 | Review Article

Measurement techniques for magnetic resonance imaging of fast relaxing nuclei

Authors: Simon Konstandin, Armin M. Nagel

Published in: Magnetic Resonance Materials in Physics, Biology and Medicine | Issue 1/2014

Login to get access

Abstract

In this review article, techniques for sodium (23Na) magnetic resonance imaging (MRI) are presented. These techniques can also be used to image other nuclei with short relaxation times (e.g., 39K, 35Cl, 17O). Twisted projection imaging, density-adapted 3D projection reconstruction, and 3D cones are preferred because of uniform k-space sampling and ultra-short echo times. Sampling density weighted apodization can be applied if intrinsic filtering is desired. This approach leads to an increased signal-to-noise ratio compared to postfiltered acquisition in cases of short readout durations relative to T 2 * relaxation time. Different MR approaches for anisotropic resolution are presented, which are important for imaging of thin structures such as myocardium, cartilage, and skin. The third part of this review article describes different methods to put more weighting either on the intracellular or the extracellular sodium signal by means of contrast agents, relaxation-weighted imaging, or multiple-quantum filtering.
Literature
1.
go back to reference Hilal SK, Ra JB, Oh CH, Mun IK, Einstein SG, Roschmann P (1988) Sodium imaging. In: Stark DD, Bradly WG (eds) Magnetic resonance imaging. C.V. Mosby, St. Louis, pp 715–729 Hilal SK, Ra JB, Oh CH, Mun IK, Einstein SG, Roschmann P (1988) Sodium imaging. In: Stark DD, Bradly WG (eds) Magnetic resonance imaging. C.V. Mosby, St. Louis, pp 715–729
2.
go back to reference Boada FE, Laverde G, Jungreis C, Nemoto E, Tanase C, Hancu I (2005) Loss of cell ion homeostasis and cell viability in the brain: what sodium MRI can tell us. Curr Top Dev Biol 70:77–101PubMed Boada FE, Laverde G, Jungreis C, Nemoto E, Tanase C, Hancu I (2005) Loss of cell ion homeostasis and cell viability in the brain: what sodium MRI can tell us. Curr Top Dev Biol 70:77–101PubMed
3.
go back to reference Sandstede JJ, Hillenbrand H, Beer M, Pabst T, Butter F, Machann W, Bauer W, Hahn D, Neubauer S (2004) Time course of 23Na signal intensity after myocardial infarction in humans. Magn Reson Med 52(3):545–551PubMed Sandstede JJ, Hillenbrand H, Beer M, Pabst T, Butter F, Machann W, Bauer W, Hahn D, Neubauer S (2004) Time course of 23Na signal intensity after myocardial infarction in humans. Magn Reson Med 52(3):545–551PubMed
4.
go back to reference Thulborn KR, Davis D, Adams H, Gindin T, Zhou J (1999) Quantitative tissue sodium concentration mapping of the growth of focal cerebral tumors with sodium magnetic resonance imaging. Magn Reson Med 41(2):351–359PubMed Thulborn KR, Davis D, Adams H, Gindin T, Zhou J (1999) Quantitative tissue sodium concentration mapping of the growth of focal cerebral tumors with sodium magnetic resonance imaging. Magn Reson Med 41(2):351–359PubMed
5.
go back to reference Ouwerkerk R, Bleich KB, Gillen JS, Pomper MG, Bottomley PA (2003) Tissue sodium concentration in human brain tumors as measured with 23Na MR imaging. Radiology 227(2):529–537PubMed Ouwerkerk R, Bleich KB, Gillen JS, Pomper MG, Bottomley PA (2003) Tissue sodium concentration in human brain tumors as measured with 23Na MR imaging. Radiology 227(2):529–537PubMed
6.
go back to reference Schepkin VD, Lee KC, Kuszpit K, Muthuswami M, Johnson TD, Chenevert TL, Rehemtulla A, Ross BD (2006) Proton and sodium MRI assessment of emerging tumor chemotherapeutic resistance. NMR Biomed 19(8):1035–1042PubMedCentralPubMed Schepkin VD, Lee KC, Kuszpit K, Muthuswami M, Johnson TD, Chenevert TL, Rehemtulla A, Ross BD (2006) Proton and sodium MRI assessment of emerging tumor chemotherapeutic resistance. NMR Biomed 19(8):1035–1042PubMedCentralPubMed
7.
go back to reference Nagel AM, Bock M, Hartmann C, Gerigk L, Neumann JO, Weber MA, Bendszus M, Radbruch A, Wick W, Schlemmer HP, Semmler W, Biller A (2011) The potential of relaxation-weighted sodium magnetic resonance imaging as demonstrated on brain tumors. Invest Radiol 46(9):539–547PubMed Nagel AM, Bock M, Hartmann C, Gerigk L, Neumann JO, Weber MA, Bendszus M, Radbruch A, Wick W, Schlemmer HP, Semmler W, Biller A (2011) The potential of relaxation-weighted sodium magnetic resonance imaging as demonstrated on brain tumors. Invest Radiol 46(9):539–547PubMed
8.
go back to reference Thulborn KR, Gindin TS, Davis D, Erb P (1999) Comprehensive MR imaging protocol for stroke management: tissue sodium concentration as a measure of tissue viability in nonhuman primate studies and in clinical studies. Radiology 213(1):156–166PubMed Thulborn KR, Gindin TS, Davis D, Erb P (1999) Comprehensive MR imaging protocol for stroke management: tissue sodium concentration as a measure of tissue viability in nonhuman primate studies and in clinical studies. Radiology 213(1):156–166PubMed
9.
go back to reference Thulborn KR, Davis D, Snyder J, Yonas H, Kassam A (2005) Sodium MR imaging of acute and subacute stroke for assessment of tissue viability. Neuroimaging Clin N Am 15(3):639–653PubMed Thulborn KR, Davis D, Snyder J, Yonas H, Kassam A (2005) Sodium MR imaging of acute and subacute stroke for assessment of tissue viability. Neuroimaging Clin N Am 15(3):639–653PubMed
10.
go back to reference Hussain MS, Stobbe RW, Bhagat YA, Emery D, Butcher KS, Manawadu D, Rizvi N, Maheshwari P, Scozzafava J, Shuaib A, Beaulieu C (2009) Sodium imaging intensity increases with time after human ischemic stroke. Ann Neurol 66(1):55–62PubMed Hussain MS, Stobbe RW, Bhagat YA, Emery D, Butcher KS, Manawadu D, Rizvi N, Maheshwari P, Scozzafava J, Shuaib A, Beaulieu C (2009) Sodium imaging intensity increases with time after human ischemic stroke. Ann Neurol 66(1):55–62PubMed
11.
go back to reference Tsang A, Stobbe RW, Asdaghi N, Hussain MS, Bhagat YA, Beaulieu C, Emery D, Butcher KS (2011) Relationship between sodium intensity and perfusion deficits in acute ischemic stroke. J Magn Reson Imaging 33(1):41–47PubMed Tsang A, Stobbe RW, Asdaghi N, Hussain MS, Bhagat YA, Beaulieu C, Emery D, Butcher KS (2011) Relationship between sodium intensity and perfusion deficits in acute ischemic stroke. J Magn Reson Imaging 33(1):41–47PubMed
12.
go back to reference Inglese M, Madelin G, Oesingmann N, Babb JS, Wu W, Stoeckel B, Herbert J, Johnson G (2010) Brain tissue sodium concentration in multiple sclerosis: a sodium imaging study at 3 Tesla. Brain 133(Pt 3):847–857PubMed Inglese M, Madelin G, Oesingmann N, Babb JS, Wu W, Stoeckel B, Herbert J, Johnson G (2010) Brain tissue sodium concentration in multiple sclerosis: a sodium imaging study at 3 Tesla. Brain 133(Pt 3):847–857PubMed
13.
go back to reference Zaaraoui W, Konstandin S, Audoin B, Nagel AM, Rico A, Malikova I, Soulier E, Viout P, Confort-Gouny S, Cozzone PJ, Pelletier J, Schad LR, Ranjeva JP (2012) Distribution of brain sodium accumulation correlates with disability in multiple sclerosis: a cross-sectional 23Na MR imaging study. Radiology 264(3):859–867PubMed Zaaraoui W, Konstandin S, Audoin B, Nagel AM, Rico A, Malikova I, Soulier E, Viout P, Confort-Gouny S, Cozzone PJ, Pelletier J, Schad LR, Ranjeva JP (2012) Distribution of brain sodium accumulation correlates with disability in multiple sclerosis: a cross-sectional 23Na MR imaging study. Radiology 264(3):859–867PubMed
14.
go back to reference Mellon EA, Pilkinton DT, Clark CM, Elliott MA, Witschey WR 2nd, Borthakur A, Reddy R (2009) Sodium MR imaging detection of mild Alzheimer disease: preliminary study. AJNR Am J Neuroradiol 30(5):978–984PubMedCentralPubMed Mellon EA, Pilkinton DT, Clark CM, Elliott MA, Witschey WR 2nd, Borthakur A, Reddy R (2009) Sodium MR imaging detection of mild Alzheimer disease: preliminary study. AJNR Am J Neuroradiol 30(5):978–984PubMedCentralPubMed
15.
go back to reference Henzler T, Konstandin S, Schmid-Bindert G, Apfaltrer P, Haneder S, Wenz F, Schad L, Manegold C, Schoenberg SO, Fink C (2012) Imaging of tumor viability in lung cancer: initial results using 23Na-MRI. Rofo 184(4):340–344PubMed Henzler T, Konstandin S, Schmid-Bindert G, Apfaltrer P, Haneder S, Wenz F, Schad L, Manegold C, Schoenberg SO, Fink C (2012) Imaging of tumor viability in lung cancer: initial results using 23Na-MRI. Rofo 184(4):340–344PubMed
16.
go back to reference Sandstede JJ, Pabst T, Beer M, Lipke C, Baurle K, Butter F, Harre K, Kenn W, Voelker W, Neubauer S, Hahn D (2001) Assessment of myocardial infarction in humans with (23)Na MR imaging: comparison with cine MR imaging and delayed contrast enhancement. Radiology 221(1):222–228PubMed Sandstede JJ, Pabst T, Beer M, Lipke C, Baurle K, Butter F, Harre K, Kenn W, Voelker W, Neubauer S, Hahn D (2001) Assessment of myocardial infarction in humans with (23)Na MR imaging: comparison with cine MR imaging and delayed contrast enhancement. Radiology 221(1):222–228PubMed
17.
go back to reference Jerecic R, Bock M, Nielles-Vallespin S, Wacker C, Bauer W, Schad LR (2004) ECG-gated 23Na-MRI of the human heart using a 3D-radial projection technique with ultra-short echo times. Magn Reson Mater Phy 16(6):297–302 Jerecic R, Bock M, Nielles-Vallespin S, Wacker C, Bauer W, Schad LR (2004) ECG-gated 23Na-MRI of the human heart using a 3D-radial projection technique with ultra-short echo times. Magn Reson Mater Phy 16(6):297–302
18.
go back to reference Ouwerkerk R, Bottomley PA, Solaiyappan M, Spooner AE, Tomaselli GF, Wu KC, Weiss RG (2008) Tissue sodium concentration in myocardial infarction in humans: a quantitative 23Na MR imaging study. Radiology 248(1):88–96PubMedCentralPubMed Ouwerkerk R, Bottomley PA, Solaiyappan M, Spooner AE, Tomaselli GF, Wu KC, Weiss RG (2008) Tissue sodium concentration in myocardial infarction in humans: a quantitative 23Na MR imaging study. Radiology 248(1):88–96PubMedCentralPubMed
19.
go back to reference Konstandin S, Schad LR (2012) Two-dimensional radial sodium heart MRI using variable-rate selective excitation and retrospective electrocardiogram gating with golden angle increments. Magn Reson Med. doi:10.1002/mrm.24523 Konstandin S, Schad LR (2012) Two-dimensional radial sodium heart MRI using variable-rate selective excitation and retrospective electrocardiogram gating with golden angle increments. Magn Reson Med. doi:10.​1002/​mrm.​24523
20.
go back to reference Maril N, Rosen Y, Reynolds GH, Ivanishev A, Ngo L, Lenkinski RE (2006) Sodium MRI of the human kidney at 3 Tesla. Magn Reson Med 56(6):1229–1234PubMed Maril N, Rosen Y, Reynolds GH, Ivanishev A, Ngo L, Lenkinski RE (2006) Sodium MRI of the human kidney at 3 Tesla. Magn Reson Med 56(6):1229–1234PubMed
21.
go back to reference Rosen Y, Lenkinski RE (2009) Sodium MRI of a human transplanted kidney. Acad Radiol 16(7):886–889PubMed Rosen Y, Lenkinski RE (2009) Sodium MRI of a human transplanted kidney. Acad Radiol 16(7):886–889PubMed
22.
go back to reference Haneder S, Konstandin S, Morelli JN, Nagel AM, Zoellner FG, Schad LR, Schoenberg SO, Michaely HJ (2011) Quantitative and qualitative (23)Na MR imaging of the human kidneys at 3 T: before and after a water load. Radiology 260(3):857–865PubMed Haneder S, Konstandin S, Morelli JN, Nagel AM, Zoellner FG, Schad LR, Schoenberg SO, Michaely HJ (2011) Quantitative and qualitative (23)Na MR imaging of the human kidneys at 3 T: before and after a water load. Radiology 260(3):857–865PubMed
23.
go back to reference Hausmann D, Konstandin S, Wetterling F, Haneder S, Nagel AM, Dinter DJ, Schonberg SO, Zollner FG, Schad LR (2012) Apparent diffusion coefficient and sodium concentration measurements in human prostate tissue via hydrogen-1 and sodium-23 magnetic resonance imaging in a clinical setting at 3T. Invest Radiol 47(12):677–682PubMed Hausmann D, Konstandin S, Wetterling F, Haneder S, Nagel AM, Dinter DJ, Schonberg SO, Zollner FG, Schad LR (2012) Apparent diffusion coefficient and sodium concentration measurements in human prostate tissue via hydrogen-1 and sodium-23 magnetic resonance imaging in a clinical setting at 3T. Invest Radiol 47(12):677–682PubMed
24.
go back to reference Constantinides CD, Gillen JS, Boada FE, Pomper MG, Bottomley PA (2000) Human skeletal muscle: sodium MR imaging and quantification-potential applications in exercise and disease. Radiology 216(2):559–568PubMed Constantinides CD, Gillen JS, Boada FE, Pomper MG, Bottomley PA (2000) Human skeletal muscle: sodium MR imaging and quantification-potential applications in exercise and disease. Radiology 216(2):559–568PubMed
25.
go back to reference Nielles-Vallespin S, Weber MA, Bock M, Bongers A, Speier P, Combs SE, Wohrle J, Lehmann-Horn F, Essig M, Schad LR (2007) 3D radial projection technique with ultrashort echo times for sodium MRI: clinical applications in human brain and skeletal muscle. Magn Reson Med 57(1):74–81PubMed Nielles-Vallespin S, Weber MA, Bock M, Bongers A, Speier P, Combs SE, Wohrle J, Lehmann-Horn F, Essig M, Schad LR (2007) 3D radial projection technique with ultrashort echo times for sodium MRI: clinical applications in human brain and skeletal muscle. Magn Reson Med 57(1):74–81PubMed
26.
go back to reference Nagel AM, Amarteifio E, Lehmann-Horn F, Jurkat-Rott K, Semmler W, Schad LR, Weber MA (2011) 3 Tesla sodium inversion recovery magnetic resonance imaging allows for improved visualization of intracellular sodium content changes in muscular channelopathies. Invest Radiol 46(12):759–766PubMed Nagel AM, Amarteifio E, Lehmann-Horn F, Jurkat-Rott K, Semmler W, Schad LR, Weber MA (2011) 3 Tesla sodium inversion recovery magnetic resonance imaging allows for improved visualization of intracellular sodium content changes in muscular channelopathies. Invest Radiol 46(12):759–766PubMed
27.
go back to reference Reddy R, Insko EK, Noyszewski EA, Dandora R, Kneeland JB, Leigh JS (1998) Sodium MRI of human articular cartilage in vivo. Magn Reson Med 39(5):697–701PubMed Reddy R, Insko EK, Noyszewski EA, Dandora R, Kneeland JB, Leigh JS (1998) Sodium MRI of human articular cartilage in vivo. Magn Reson Med 39(5):697–701PubMed
28.
go back to reference Borthakur A, Shapiro EM, Beers J, Kudchodkar S, Kneeland JB, Reddy R (2000) Sensitivity of MRI to proteoglycan depletion in cartilage: comparison of sodium and proton MRI. Osteoarthritis Cartilage 8(4):288–293PubMed Borthakur A, Shapiro EM, Beers J, Kudchodkar S, Kneeland JB, Reddy R (2000) Sensitivity of MRI to proteoglycan depletion in cartilage: comparison of sodium and proton MRI. Osteoarthritis Cartilage 8(4):288–293PubMed
29.
go back to reference Shapiro EM, Borthakur A, Gougoutas A, Reddy R (2002) 23Na MRI accurately measures fixed charge density in articular cartilage. Magn Reson Med 47(2):284–291PubMedCentralPubMed Shapiro EM, Borthakur A, Gougoutas A, Reddy R (2002) 23Na MRI accurately measures fixed charge density in articular cartilage. Magn Reson Med 47(2):284–291PubMedCentralPubMed
30.
go back to reference Wheaton AJ, Borthakur A, Shapiro EM, Regatte RR, Akella SV, Kneeland JB, Reddy R (2004) Proteoglycan loss in human knee cartilage: quantitation with sodium MR imaging—feasibility study. Radiology 231(3):900–905PubMed Wheaton AJ, Borthakur A, Shapiro EM, Regatte RR, Akella SV, Kneeland JB, Reddy R (2004) Proteoglycan loss in human knee cartilage: quantitation with sodium MR imaging—feasibility study. Radiology 231(3):900–905PubMed
31.
go back to reference Trattnig S, Welsch GH, Juras V, Szomolanyi P, Mayerhoefer ME, Stelzeneder D, Mamisch TC, Bieri O, Scheffler K, Zbyn S (2010) 23Na MR imaging at 7 T after knee matrix-associated autologous chondrocyte transplantation preliminary results. Radiology 257(1):175–184PubMed Trattnig S, Welsch GH, Juras V, Szomolanyi P, Mayerhoefer ME, Stelzeneder D, Mamisch TC, Bieri O, Scheffler K, Zbyn S (2010) 23Na MR imaging at 7 T after knee matrix-associated autologous chondrocyte transplantation preliminary results. Radiology 257(1):175–184PubMed
32.
go back to reference Thulborn KR, Lu A, Atkinson IC, Damen F, Villano JL (2009) Quantitative sodium MR imaging and sodium bioscales for the management of brain tumors. Neuroimaging Clin N Am 19(4):615–624PubMedCentralPubMed Thulborn KR, Lu A, Atkinson IC, Damen F, Villano JL (2009) Quantitative sodium MR imaging and sodium bioscales for the management of brain tumors. Neuroimaging Clin N Am 19(4):615–624PubMedCentralPubMed
33.
go back to reference Jennings RB, Sommers HM, Kaltenbach JP, West JJ (1964) Electrolyte alterations in acute myocardial ischemic injury. Circ Res 14:260–269PubMed Jennings RB, Sommers HM, Kaltenbach JP, West JJ (1964) Electrolyte alterations in acute myocardial ischemic injury. Circ Res 14:260–269PubMed
34.
go back to reference Jentsch TJ, Stein V, Weinreich F, Zdebik AA (2002) Molecular structure and physiological function of chloride channels. Physiol Rev 82(2):503–568PubMed Jentsch TJ, Stein V, Weinreich F, Zdebik AA (2002) Molecular structure and physiological function of chloride channels. Physiol Rev 82(2):503–568PubMed
35.
go back to reference Fieno DS, Kim RJ, Rehwald WG, Judd RM (1999) Physiological basis for potassium (39K) magnetic resonance imaging of the heart. Circ Res 84(8):913–920PubMed Fieno DS, Kim RJ, Rehwald WG, Judd RM (1999) Physiological basis for potassium (39K) magnetic resonance imaging of the heart. Circ Res 84(8):913–920PubMed
36.
go back to reference Augath M, Heiler P, Kirsch S, Schad LR (2009) In vivo 39K, 23Na and 1H MR imaging using a triple resonant RF coil setup. J Magn Reson 200(1):134–136PubMed Augath M, Heiler P, Kirsch S, Schad LR (2009) In vivo 39K, 23Na and 1H MR imaging using a triple resonant RF coil setup. J Magn Reson 200(1):134–136PubMed
37.
go back to reference Romanenko KV, Cano-Barrita PF, Balcom BJ (2009) (35)Cl profiling using centric scan SPRITE with variable flip angle excitation. J Magn Reson 198(1):24–30PubMed Romanenko KV, Cano-Barrita PF, Balcom BJ (2009) (35)Cl profiling using centric scan SPRITE with variable flip angle excitation. J Magn Reson 198(1):24–30PubMed
38.
go back to reference Kirsch S, Augath M, Seiffge D, Schilling L, Schad LR (2010) In vivo chlorine-35, sodium-23 and proton magnetic resonance imaging of the rat brain. NMR Biomed 23(6):592–600PubMed Kirsch S, Augath M, Seiffge D, Schilling L, Schad LR (2010) In vivo chlorine-35, sodium-23 and proton magnetic resonance imaging of the rat brain. NMR Biomed 23(6):592–600PubMed
39.
go back to reference Nagel AM, Weber MA, Lehmann-Horn F, Jurkat-Rott K, Radbruch A, Umathum R, Semmler W (2013) Chlorine (35Cl) MRI in humans: Cl—alterations do not correspond to disease-related Na + changes. In: Proceedings of the 21st scientific meeting, International Society for Magnetic Resonance in Medicine, Salt Lake City, p 116 Nagel AM, Weber MA, Lehmann-Horn F, Jurkat-Rott K, Radbruch A, Umathum R, Semmler W (2013) Chlorine (35Cl) MRI in humans: Cl—alterations do not correspond to disease-related Na + changes. In: Proceedings of the 21st scientific meeting, International Society for Magnetic Resonance in Medicine, Salt Lake City, p 116
40.
go back to reference Zhu XH, Zhang Y, Tian RX, Lei H, Zhang N, Zhang X, Merkle H, Ugurbil K, Chen W (2002) Development of (17)O NMR approach for fast imaging of cerebral metabolic rate of oxygen in rat brain at high field. Proc Natl Acad Sci USA 99(20):13194–13199PubMed Zhu XH, Zhang Y, Tian RX, Lei H, Zhang N, Zhang X, Merkle H, Ugurbil K, Chen W (2002) Development of (17)O NMR approach for fast imaging of cerebral metabolic rate of oxygen in rat brain at high field. Proc Natl Acad Sci USA 99(20):13194–13199PubMed
41.
go back to reference Fiat D, Hankiewicz J, Liu S, Trbovic S, Brint S (2004) 17O magnetic resonance imaging of the human brain. Neurol Res 26(8):803–808PubMed Fiat D, Hankiewicz J, Liu S, Trbovic S, Brint S (2004) 17O magnetic resonance imaging of the human brain. Neurol Res 26(8):803–808PubMed
42.
go back to reference Zhang N, Zhu XH, Lei H, Ugurbil K, Chen W (2004) Simplified methods for calculating cerebral metabolic rate of oxygen based on 17O magnetic resonance spectroscopic imaging measurement during a short 17O2 inhalation. J Cereb Blood Flow Metab 24(8):840–848PubMed Zhang N, Zhu XH, Lei H, Ugurbil K, Chen W (2004) Simplified methods for calculating cerebral metabolic rate of oxygen based on 17O magnetic resonance spectroscopic imaging measurement during a short 17O2 inhalation. J Cereb Blood Flow Metab 24(8):840–848PubMed
43.
go back to reference Zhu XH, Zhang N, Zhang Y, Zhang X, Ugurbil K, Chen W (2005) In vivo 17O NMR approaches for brain study at high field. NMR Biomed 18(2):83–103PubMed Zhu XH, Zhang N, Zhang Y, Zhang X, Ugurbil K, Chen W (2005) In vivo 17O NMR approaches for brain study at high field. NMR Biomed 18(2):83–103PubMed
44.
go back to reference Atkinson IC, Sonstegaard R, Pliskin NH, Thulborn KR (2010) Vital signs and cognitive function are not affected by 23-sodium and 17-oxygen magnetic resonance imaging of the human brain at 9.4 T. J Magn Reson Imaging 32(1):82–87PubMed Atkinson IC, Sonstegaard R, Pliskin NH, Thulborn KR (2010) Vital signs and cognitive function are not affected by 23-sodium and 17-oxygen magnetic resonance imaging of the human brain at 9.4 T. J Magn Reson Imaging 32(1):82–87PubMed
45.
go back to reference Atkinson IC, Thulborn KR (2010) Feasibility of mapping the tissue mass corrected bioscale of cerebral metabolic rate of oxygen consumption using 17-oxygen and 23-sodium MR imaging in a human brain at 9.4 T. Neuroimage 51(2):723–733PubMed Atkinson IC, Thulborn KR (2010) Feasibility of mapping the tissue mass corrected bioscale of cerebral metabolic rate of oxygen consumption using 17-oxygen and 23-sodium MR imaging in a human brain at 9.4 T. Neuroimage 51(2):723–733PubMed
46.
go back to reference Hoffmann SH, Begovatz P, Nagel AM, Umathum R, Schommer K, Bachert P, Bock M (2011) A measurement setup for direct 17O MRI at 7 T. Magn Reson Med 66(4):1109–1115PubMed Hoffmann SH, Begovatz P, Nagel AM, Umathum R, Schommer K, Bachert P, Bock M (2011) A measurement setup for direct 17O MRI at 7 T. Magn Reson Med 66(4):1109–1115PubMed
47.
go back to reference McCommis KS, He X, Abendschein DR, Gupte PM, Gropler RJ, Zheng J (2010) Cardiac 17O MRI: toward direct quantification of myocardial oxygen consumption. Magn Reson Med 63(6):1442–1447PubMedCentralPubMed McCommis KS, He X, Abendschein DR, Gupte PM, Gropler RJ, Zheng J (2010) Cardiac 17O MRI: toward direct quantification of myocardial oxygen consumption. Magn Reson Med 63(6):1442–1447PubMedCentralPubMed
48.
go back to reference Gupta RK, Gupta P (1982) Direct observation of resolved resonances from intra- and extracellular sodium-23 ions in NMR studies of intact cells and tissues using dysprosium(III)tripolyphosphate as paramagnetic shift reagent. J Magn Reson (1969) 47:344–350 Gupta RK, Gupta P (1982) Direct observation of resolved resonances from intra- and extracellular sodium-23 ions in NMR studies of intact cells and tissues using dysprosium(III)tripolyphosphate as paramagnetic shift reagent. J Magn Reson (1969) 47:344–350
49.
go back to reference Winter PM, Bansal N (2001) TmDOTP(5-) as a (23)Na shift reagent for the subcutaneously implanted 9L gliosarcoma in rats. Magn Reson Med 45(3):436–442PubMed Winter PM, Bansal N (2001) TmDOTP(5-) as a (23)Na shift reagent for the subcutaneously implanted 9L gliosarcoma in rats. Magn Reson Med 45(3):436–442PubMed
50.
go back to reference Kline RP, Wu EX, Petrylak DP, Szabolcs M, Alderson PO, Weisfeldt ML, Cannon P, Katz J (2000) Rapid in vivo monitoring of chemotherapeutic response using weighted sodium magnetic resonance imaging. Clin Cancer Res 6(6):2146–2156PubMed Kline RP, Wu EX, Petrylak DP, Szabolcs M, Alderson PO, Weisfeldt ML, Cannon P, Katz J (2000) Rapid in vivo monitoring of chemotherapeutic response using weighted sodium magnetic resonance imaging. Clin Cancer Res 6(6):2146–2156PubMed
51.
go back to reference Borthakur A, Hancu I, Boada FE, Shen GX, Shapiro EM, Reddy R (1999) In vivo triple quantum filtered twisted projection sodium MRI of human articular cartilage. J Magn Reson 141(2):286–290PubMed Borthakur A, Hancu I, Boada FE, Shen GX, Shapiro EM, Reddy R (1999) In vivo triple quantum filtered twisted projection sodium MRI of human articular cartilage. J Magn Reson 141(2):286–290PubMed
52.
go back to reference Harris RK, Becker ED, Cabral de Menezes SM, Goodfellow R, Granger P (2002) NMR nomenclature: nuclear spin properties and conventions for chemical shifts. IUPAC Recommendations 2001. International Union of Pure and Applied Chemistry. Physical Chemistry Division. Commission on Molecular Structure and Spectroscopy. Magn Reson Chem 40(7):489–505 Harris RK, Becker ED, Cabral de Menezes SM, Goodfellow R, Granger P (2002) NMR nomenclature: nuclear spin properties and conventions for chemical shifts. IUPAC Recommendations 2001. International Union of Pure and Applied Chemistry. Physical Chemistry Division. Commission on Molecular Structure and Spectroscopy. Magn Reson Chem 40(7):489–505
53.
go back to reference Hilal SK, Maudsley AA, Simon HE, Perman WH, Bonn J, Mawad ME, Silver AJ, Ganti SR, Sane P, Chien IC (1983) In vivo NMR imaging of tissue sodium in the intact cat before and after acute cerebral stroke. AJNR Am J Neuroradiol 4(3):245–249PubMed Hilal SK, Maudsley AA, Simon HE, Perman WH, Bonn J, Mawad ME, Silver AJ, Ganti SR, Sane P, Chien IC (1983) In vivo NMR imaging of tissue sodium in the intact cat before and after acute cerebral stroke. AJNR Am J Neuroradiol 4(3):245–249PubMed
54.
go back to reference Hilal SK, Maudsley AA, Ra JB, Simon HE, Roschmann P, Wittekoek S, Cho ZH, Mun SK (1985) In vivo NMR imaging of sodium-23 in the human head. J Comput Assist Tomogr 9(1):1–7PubMed Hilal SK, Maudsley AA, Ra JB, Simon HE, Roschmann P, Wittekoek S, Cho ZH, Mun SK (1985) In vivo NMR imaging of sodium-23 in the human head. J Comput Assist Tomogr 9(1):1–7PubMed
55.
go back to reference Hahn EL (1950) Spin echoes. Phys Rev 80(4):580 Hahn EL (1950) Spin echoes. Phys Rev 80(4):580
56.
go back to reference Berendsen HJ, Edzes HT (1973) The observation and general interpretation of sodium magnetic resonance in biological material. Ann N Y Acad Sci 204:459–485PubMed Berendsen HJ, Edzes HT (1973) The observation and general interpretation of sodium magnetic resonance in biological material. Ann N Y Acad Sci 204:459–485PubMed
57.
go back to reference Haase A, Frahm J, Matthaei D, Hanicke W, Merboldt KD (1986) FLASH imaging. Rapid NMR imaging using low flip-angle pulses. J Magn Reson (1969) 67(2):258–266 Haase A, Frahm J, Matthaei D, Hanicke W, Merboldt KD (1986) FLASH imaging. Rapid NMR imaging using low flip-angle pulses. J Magn Reson (1969) 67(2):258–266
58.
go back to reference Granot J (1986) Sodium imaging by gradient reversal. J Magn Reson (1969) 68(3):575–581 Granot J (1986) Sodium imaging by gradient reversal. J Magn Reson (1969) 68(3):575–581
59.
go back to reference Kharrazian R, Jakob PM (2006) Dynamics of 23Na during completely balanced steady-state free precession. J Magn Reson 179(1):73–84PubMed Kharrazian R, Jakob PM (2006) Dynamics of 23Na during completely balanced steady-state free precession. J Magn Reson 179(1):73–84PubMed
60.
go back to reference Parrish TB, Fieno DS, Fitzgerald SW, Judd RM (1997) Theoretical basis for sodium and potassium MRI of the human heart at 1.5 T. Magn Reson Med 38(4):653–661PubMed Parrish TB, Fieno DS, Fitzgerald SW, Judd RM (1997) Theoretical basis for sodium and potassium MRI of the human heart at 1.5 T. Magn Reson Med 38(4):653–661PubMed
61.
go back to reference Noll DC, Nishimura DG, Macovski A (1991) Homodyne detection in magnetic resonance imaging. IEEE Trans Med Imaging 10(2):154–163PubMed Noll DC, Nishimura DG, Macovski A (1991) Homodyne detection in magnetic resonance imaging. IEEE Trans Med Imaging 10(2):154–163PubMed
62.
go back to reference Cuppen J, van Est A (1987) Reducing MR imaging time by one-sided reconstruction. Magn Reson Imaging 5(6):526–527 Cuppen J, van Est A (1987) Reducing MR imaging time by one-sided reconstruction. Magn Reson Imaging 5(6):526–527
63.
go back to reference Haacke EM, Lindskogj ED, Lin W (1991) A fast, iterative, partial-Fourier technique capable of local phase recovery. J Magn Reson (1969) 92(1):126–145 Haacke EM, Lindskogj ED, Lin W (1991) A fast, iterative, partial-Fourier technique capable of local phase recovery. J Magn Reson (1969) 92(1):126–145
64.
go back to reference Hubbard PS (1970) Nonexponential nuclear magnetic relaxation by quadrupole interactions. J Chem Phys 53(3):985–987 Hubbard PS (1970) Nonexponential nuclear magnetic relaxation by quadrupole interactions. J Chem Phys 53(3):985–987
65.
go back to reference Boada FE, Christensen JD, Huang-Hellinger FR, Reese TG, Thulborn KR (1994) Quantitative in vivo tissue sodium concentration maps: the effects of biexponential relaxation. Magn Reson Med 32(2):219–223PubMed Boada FE, Christensen JD, Huang-Hellinger FR, Reese TG, Thulborn KR (1994) Quantitative in vivo tissue sodium concentration maps: the effects of biexponential relaxation. Magn Reson Med 32(2):219–223PubMed
66.
go back to reference Lauterbur PC (1973) Image formation by induced local interactions: examples employing nuclear magnetic resonance. Nature 242(5394):190–191 Lauterbur PC (1973) Image formation by induced local interactions: examples employing nuclear magnetic resonance. Nature 242(5394):190–191
67.
go back to reference Glover GH, Pauly JM, Bradshaw KM (1992) Boron-11 imaging with a three-dimensional reconstruction method. J Magn Reson Imaging 2(1):47–52PubMed Glover GH, Pauly JM, Bradshaw KM (1992) Boron-11 imaging with a three-dimensional reconstruction method. J Magn Reson Imaging 2(1):47–52PubMed
68.
go back to reference Rakhmanov EA, Saff EB, Zhou YM (1994) Minimal discrete energy on the sphere. Math Res Lett 1:647–662 Rakhmanov EA, Saff EB, Zhou YM (1994) Minimal discrete energy on the sphere. Math Res Lett 1:647–662
69.
go back to reference Liao JR, Pauly JM, Brosnan TJ, Pelc NJ (1997) Reduction of motion artifacts in cine MRI using variable-density spiral trajectories. Magn Reson Med 37(4):569–575PubMed Liao JR, Pauly JM, Brosnan TJ, Pelc NJ (1997) Reduction of motion artifacts in cine MRI using variable-density spiral trajectories. Magn Reson Med 37(4):569–575PubMed
70.
go back to reference Pipe JG, Duerk JL (1995) Analytical resolution and noise characteristics of linearly reconstructed magnetic resonance data with arbitrary k-space sampling. Magn Reson Med 34(2):170–178PubMed Pipe JG, Duerk JL (1995) Analytical resolution and noise characteristics of linearly reconstructed magnetic resonance data with arbitrary k-space sampling. Magn Reson Med 34(2):170–178PubMed
71.
go back to reference Gurney PT, Hargreaves BA, Nishimura DG (2006) Design and analysis of a practical 3D cones trajectory. Magn Reson Med 55(3):575–582PubMed Gurney PT, Hargreaves BA, Nishimura DG (2006) Design and analysis of a practical 3D cones trajectory. Magn Reson Med 55(3):575–582PubMed
72.
go back to reference Rahmer J, Bornert P, Groen J, Bos C (2006) Three-dimensional radial ultrashort echo-time imaging with T 2 adapted sampling. Magn Reson Med 55(5):1075–1082PubMed Rahmer J, Bornert P, Groen J, Bos C (2006) Three-dimensional radial ultrashort echo-time imaging with T 2 adapted sampling. Magn Reson Med 55(5):1075–1082PubMed
73.
go back to reference O’Donnell M, Edelstein WA (1985) NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities. Med Phys 12(1):20–26PubMed O’Donnell M, Edelstein WA (1985) NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities. Med Phys 12(1):20–26PubMed
74.
go back to reference Cooley JW, Tukey JW (1965) An algorithm for the machine calculation of complex Fourier series. Math Comput 19:297–301 Cooley JW, Tukey JW (1965) An algorithm for the machine calculation of complex Fourier series. Math Comput 19:297–301
75.
go back to reference O’Sullivan JD (1985) A fast sinc function gridding algorithm for Fourier inversion in computer tomography. IEEE Trans Med Imaging MI 4:200–207 O’Sullivan JD (1985) A fast sinc function gridding algorithm for Fourier inversion in computer tomography. IEEE Trans Med Imaging MI 4:200–207
76.
go back to reference Fessler JA, Sutton BP (2003) Nonuniform fast Fourier transforms using min-max interpolation. IEEE Trans Signal Proc 51(2):560–574 Fessler JA, Sutton BP (2003) Nonuniform fast Fourier transforms using min-max interpolation. IEEE Trans Signal Proc 51(2):560–574
77.
go back to reference Beatty PJ, Nishimura DG, Pauly JM (2005) Rapid gridding reconstruction with a minimal oversampling ratio. IEEE Trans Med Imaging 24(6):799–808PubMed Beatty PJ, Nishimura DG, Pauly JM (2005) Rapid gridding reconstruction with a minimal oversampling ratio. IEEE Trans Med Imaging 24(6):799–808PubMed
78.
go back to reference Atkinson IC, Liu G, Obeid N, Thulborn KR, Hwu WM (2013) Rapid computation of sodium bioscales using GPU-accelerated image reconstruction. Int J Imag Syst Technol 23:29–35 Atkinson IC, Liu G, Obeid N, Thulborn KR, Hwu WM (2013) Rapid computation of sodium bioscales using GPU-accelerated image reconstruction. Int J Imag Syst Technol 23:29–35
79.
go back to reference Oesterle C, Markl M, Strecker R, Kraemer FM, Hennig J (1999) Spiral reconstruction by regridding to a large rectilinear matrix: a practical solution for routine systems. J Magn Reson Imaging 10(1):84–92PubMed Oesterle C, Markl M, Strecker R, Kraemer FM, Hennig J (1999) Spiral reconstruction by regridding to a large rectilinear matrix: a practical solution for routine systems. J Magn Reson Imaging 10(1):84–92PubMed
80.
go back to reference Nuttal AH (1981) Some windows with very good sidelobe behavior. IEEE Trans Acoust Speech 29(1):84–91 Nuttal AH (1981) Some windows with very good sidelobe behavior. IEEE Trans Acoust Speech 29(1):84–91
81.
go back to reference Jackson JI, Meyer CH, Nishimura DG, Macovski A (1991) Selection of a convolution function for Fourier inversion using gridding. IEEE Trans Med Imaging 10(3):473–478PubMed Jackson JI, Meyer CH, Nishimura DG, Macovski A (1991) Selection of a convolution function for Fourier inversion using gridding. IEEE Trans Med Imaging 10(3):473–478PubMed
82.
go back to reference Boada FE, Gillen JS, Shen GX, Chang SY, Thulborn KR (1997) Fast three dimensional sodium imaging. Magn Reson Med 37(5):706–715PubMed Boada FE, Gillen JS, Shen GX, Chang SY, Thulborn KR (1997) Fast three dimensional sodium imaging. Magn Reson Med 37(5):706–715PubMed
83.
go back to reference Nagel AM, Laun FB, Weber MA, Matthies C, Semmler W, Schad LR (2009) Sodium MRI using a density-adapted 3D radial acquisition technique. Magn Reson Med 62(6):1565–1573PubMed Nagel AM, Laun FB, Weber MA, Matthies C, Semmler W, Schad LR (2009) Sodium MRI using a density-adapted 3D radial acquisition technique. Magn Reson Med 62(6):1565–1573PubMed
84.
go back to reference Irarrazabal P, Nishimura DG (1995) Fast three dimensional magnetic resonance imaging. Magn Reson Med 33(5):656–662PubMed Irarrazabal P, Nishimura DG (1995) Fast three dimensional magnetic resonance imaging. Magn Reson Med 33(5):656–662PubMed
85.
go back to reference Peters DC, Derbyshire JA, McVeigh ER (2003) Centering the projection reconstruction trajectory: reducing gradient delay errors. Magn Reson Med 50(1):1–6PubMedCentralPubMed Peters DC, Derbyshire JA, McVeigh ER (2003) Centering the projection reconstruction trajectory: reducing gradient delay errors. Magn Reson Med 50(1):1–6PubMedCentralPubMed
86.
go back to reference Atkinson IC, Lu A, Thulborn KR (2009) Characterization and correction of system delays and eddy currents for MR imaging with ultrashort echo-time and time-varying gradients. Magn Reson Med 62(2):532–537PubMed Atkinson IC, Lu A, Thulborn KR (2009) Characterization and correction of system delays and eddy currents for MR imaging with ultrashort echo-time and time-varying gradients. Magn Reson Med 62(2):532–537PubMed
87.
go back to reference Lu A, Atkinson IC, Vaughn JT, Thulborn KR (2011) Impact of gradient timing error on the tissue sodium concentration bioscale measured using flexible twisted projection imaging. J Magn Reson 213(1):176–181PubMedCentralPubMed Lu A, Atkinson IC, Vaughn JT, Thulborn KR (2011) Impact of gradient timing error on the tissue sodium concentration bioscale measured using flexible twisted projection imaging. J Magn Reson 213(1):176–181PubMedCentralPubMed
88.
go back to reference Barger AV, Block WF, Toropov Y, Grist TM, Mistretta CA (2002) Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory. Magn Reson Med 48(2):297–305PubMed Barger AV, Block WF, Toropov Y, Grist TM, Mistretta CA (2002) Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory. Magn Reson Med 48(2):297–305PubMed
89.
go back to reference Lu A, Atkinson IC, Claiborne TC, Damen FC, Thulborn KR (2010) Quantitative sodium imaging with a flexible twisted projection pulse sequence. Magn Reson Med 63(6):1583–1593PubMedCentralPubMed Lu A, Atkinson IC, Claiborne TC, Damen FC, Thulborn KR (2010) Quantitative sodium imaging with a flexible twisted projection pulse sequence. Magn Reson Med 63(6):1583–1593PubMedCentralPubMed
90.
go back to reference Mareci TH, Brooker HR (1991) Essential considerations for spectral localization using indirect gradient encoding of spatial information. J Magn Reson (1969) 92(2):229–246 Mareci TH, Brooker HR (1991) Essential considerations for spectral localization using indirect gradient encoding of spatial information. J Magn Reson (1969) 92(2):229–246
91.
go back to reference Heiler PM, Langhauser FL, Wetterling F, Ansar S, Grudzenski S, Konstandin S, Fatar M, Meairs S, Schad LR (2011) Chemical shift sodium imaging in a mouse model of thromboembolic stroke at 9.4 T. J Magn Reson Imaging 34(4):935–940PubMed Heiler PM, Langhauser FL, Wetterling F, Ansar S, Grudzenski S, Konstandin S, Fatar M, Meairs S, Schad LR (2011) Chemical shift sodium imaging in a mouse model of thromboembolic stroke at 9.4 T. J Magn Reson Imaging 34(4):935–940PubMed
92.
go back to reference Stobbe RW, Beaulieu C (2008) Advantage of sampling density weighted apodization over postacquisition filtering apodization for sodium MRI of the human brain. Magn Reson Med 60(4):981–986PubMed Stobbe RW, Beaulieu C (2008) Advantage of sampling density weighted apodization over postacquisition filtering apodization for sodium MRI of the human brain. Magn Reson Med 60(4):981–986PubMed
93.
go back to reference Konstandin S, Nagel AM (2013) Performance of sampling density-weighted and postfiltered density-adapted projection reconstruction in sodium magnetic resonance imaging. Magn Reson Med 69(2):495–502PubMed Konstandin S, Nagel AM (2013) Performance of sampling density-weighted and postfiltered density-adapted projection reconstruction in sodium magnetic resonance imaging. Magn Reson Med 69(2):495–502PubMed
94.
go back to reference Harris FJ (1978) On the use of windows for harmonic analysis with the discrete Fourier transform. Proc IEEE 66(1):51–83 Harris FJ (1978) On the use of windows for harmonic analysis with the discrete Fourier transform. Proc IEEE 66(1):51–83
95.
go back to reference Boada FE, Shen GX, Chang SY, Thulborn KR (1997) Spectrally weighted twisted projection imaging: reducing T 2 signal attenuation effects in fast three-dimensional sodium imaging. Magn Reson Med 38(6):1022–1028PubMed Boada FE, Shen GX, Chang SY, Thulborn KR (1997) Spectrally weighted twisted projection imaging: reducing T 2 signal attenuation effects in fast three-dimensional sodium imaging. Magn Reson Med 38(6):1022–1028PubMed
96.
go back to reference Bergin CJ, Pauly JM, Macovski A (1991) Lung parenchyma: projection reconstruction MR imaging. Radiology 179(3):777–781PubMed Bergin CJ, Pauly JM, Macovski A (1991) Lung parenchyma: projection reconstruction MR imaging. Radiology 179(3):777–781PubMed
97.
go back to reference Jackson JI, Nishimura DG, Macovski A (1992) Twisting radial lines with application to robust magnetic resonance imaging of irregular flow. Magn Reson Med 25(1):128–139PubMed Jackson JI, Nishimura DG, Macovski A (1992) Twisting radial lines with application to robust magnetic resonance imaging of irregular flow. Magn Reson Med 25(1):128–139PubMed
98.
go back to reference Konstandin S, Nagel AM, Heiler PM, Schad LR (2011) Two-dimensional radial acquisition technique with density adaption in sodium MRI. Magn Reson Med 65(4):1090–1096PubMed Konstandin S, Nagel AM, Heiler PM, Schad LR (2011) Two-dimensional radial acquisition technique with density adaption in sodium MRI. Magn Reson Med 65(4):1090–1096PubMed
99.
go back to reference Conolly S, Nishimura D, Macovski A, Glover G (1988) Variable-rate selective excitation. J Magn Reson (1969) 78(3):440–458 Conolly S, Nishimura D, Macovski A, Glover G (1988) Variable-rate selective excitation. J Magn Reson (1969) 78(3):440–458
100.
go back to reference Song J, Liu Y, Gewalt SL, Cofer G, Johnson GA, Liu QH (2009) Least-square NUFFT methods applied to 2-D and 3-D radially encoded MR image reconstruction. IEEE Trans Biomed Eng 56(4):1134–1142PubMedCentralPubMed Song J, Liu Y, Gewalt SL, Cofer G, Johnson GA, Liu QH (2009) Least-square NUFFT methods applied to 2-D and 3-D radially encoded MR image reconstruction. IEEE Trans Biomed Eng 56(4):1134–1142PubMedCentralPubMed
101.
go back to reference Qian Y, Boada FE (2008) Acquisition-weighted stack of spirals for fast high-resolution three-dimensional ultra-short echo time MR imaging. Magn Reson Med 60(1):135–145PubMed Qian Y, Boada FE (2008) Acquisition-weighted stack of spirals for fast high-resolution three-dimensional ultra-short echo time MR imaging. Magn Reson Med 60(1):135–145PubMed
102.
go back to reference Qian Y, Zhao T, Zheng H, Weimer J, Boada FE (2012) High-resolution sodium imaging of human brain at 7 T. Magn Reson Med 68(1):227–233PubMedCentralPubMed Qian Y, Zhao T, Zheng H, Weimer J, Boada FE (2012) High-resolution sodium imaging of human brain at 7 T. Magn Reson Med 68(1):227–233PubMedCentralPubMed
103.
go back to reference Staroswiecki E, Bangerter NK, Gurney PT, Grafendorfer T, Gold GE, Hargreaves BA (2010) In vivo sodium imaging of human patellar cartilage with a 3D cones sequence at 3 T and 7 T. J Magn Reson Imaging 32(2):446–451PubMedCentralPubMed Staroswiecki E, Bangerter NK, Gurney PT, Grafendorfer T, Gold GE, Hargreaves BA (2010) In vivo sodium imaging of human patellar cartilage with a 3D cones sequence at 3 T and 7 T. J Magn Reson Imaging 32(2):446–451PubMedCentralPubMed
104.
go back to reference Watts A, Stobbe RW, Beaulieu C (2011) Signal-to-noise optimization for sodium MRI of the human knee at 4.7 Tesla using steady state. Magn Reson Med 66(3):697–705PubMed Watts A, Stobbe RW, Beaulieu C (2011) Signal-to-noise optimization for sodium MRI of the human knee at 4.7 Tesla using steady state. Magn Reson Med 66(3):697–705PubMed
105.
go back to reference Nagel AM, Weber MA, Wolf MB, Semmler W (2012) 3D Density-adapted projection reconstruction 23Na-MRI with anisotropic resolution and field-of-view. In: Proceedings of the 20th scientific meeting, International Society for Magnetic Resonance in Medicine, Melbourne, p 2282 Nagel AM, Weber MA, Wolf MB, Semmler W (2012) 3D Density-adapted projection reconstruction 23Na-MRI with anisotropic resolution and field-of-view. In: Proceedings of the 20th scientific meeting, International Society for Magnetic Resonance in Medicine, Melbourne, p 2282
106.
go back to reference Larson PZ, Gurney PT, Nishimura DG (2008) Anisotropic field-of-views in radial imaging. IEEE Trans Med Imaging 27(1):47–57PubMed Larson PZ, Gurney PT, Nishimura DG (2008) Anisotropic field-of-views in radial imaging. IEEE Trans Med Imaging 27(1):47–57PubMed
107.
go back to reference Scheffler K, Hennig J (1998) Reduced circular field-of-view imaging. Magn Reson Med 40(3):474–480PubMed Scheffler K, Hennig J (1998) Reduced circular field-of-view imaging. Magn Reson Med 40(3):474–480PubMed
108.
go back to reference Bansal N, Germann MJ, Seshan V, Shires GT 3rd, Malloy CR, Sherry AD (1993) Thulium 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetrakis(methylene phosphonate) as a 23Na shift reagent for the in vivo rat liver. Biochemistry 32(21):5638–5643PubMed Bansal N, Germann MJ, Seshan V, Shires GT 3rd, Malloy CR, Sherry AD (1993) Thulium 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetrakis(methylene phosphonate) as a 23Na shift reagent for the in vivo rat liver. Biochemistry 32(21):5638–5643PubMed
109.
go back to reference Naritomi H, Kanashiro M, Sasaki M, Kuribayashi Y, Sawada T (1987) In vivo measurements of intra- and extracellular Na+ and water in the brain and muscle by nuclear magnetic resonance spectroscopy with shift reagent. Biophys J 52(4):611–616PubMedCentralPubMed Naritomi H, Kanashiro M, Sasaki M, Kuribayashi Y, Sawada T (1987) In vivo measurements of intra- and extracellular Na+ and water in the brain and muscle by nuclear magnetic resonance spectroscopy with shift reagent. Biophys J 52(4):611–616PubMedCentralPubMed
110.
go back to reference Bansal N, Germann MJ, Lazar I, Malloy CR, Sherry AD (1992) In vivo Na-23 MR imaging and spectroscopy of rat brain during TmDOTP5-infusion. J Magn Reson Imaging 2(4):385–391PubMed Bansal N, Germann MJ, Lazar I, Malloy CR, Sherry AD (1992) In vivo Na-23 MR imaging and spectroscopy of rat brain during TmDOTP5-infusion. J Magn Reson Imaging 2(4):385–391PubMed
111.
go back to reference Stobbe R, Beaulieu C (2005) In vivo sodium magnetic resonance imaging of the human brain using soft inversion recovery fluid attenuation. Magn Reson Med 54(5):1305–1310PubMed Stobbe R, Beaulieu C (2005) In vivo sodium magnetic resonance imaging of the human brain using soft inversion recovery fluid attenuation. Magn Reson Med 54(5):1305–1310PubMed
112.
go back to reference Madelin G, Lee JS, Inati S, Jerschow A, Regatte RR (2010) Sodium inversion recovery MRI of the knee joint in vivo at 7T. J Magn Reson 207(1):42–52PubMedCentralPubMed Madelin G, Lee JS, Inati S, Jerschow A, Regatte RR (2010) Sodium inversion recovery MRI of the knee joint in vivo at 7T. J Magn Reson 207(1):42–52PubMedCentralPubMed
113.
go back to reference Slichter CP (1989) Principles of magnetic resonance. Springer, Berlin Slichter CP (1989) Principles of magnetic resonance. Springer, Berlin
114.
go back to reference Bodenhausen G (1981) Multiple-quantum NMR. Prog Nucl Mag Res Spectrosc 14:137–173 Bodenhausen G (1981) Multiple-quantum NMR. Prog Nucl Mag Res Spectrosc 14:137–173
115.
go back to reference Pekar J, Renshaw PF, Leigh JS (1987) Selective detection of intracellular sodium by coherence-transfer NMR. J Magn Reson (1969) 72(1):159–161 Pekar J, Renshaw PF, Leigh JS (1987) Selective detection of intracellular sodium by coherence-transfer NMR. J Magn Reson (1969) 72(1):159–161
116.
go back to reference Jaccard G, Wimperis S, Bodenhausen G (1986) Multiple-quantum NMR spectroscopy of S = 3/2 spins in isotropic phase: a new probe for multiexponential relaxation. J Chem Phys 85(11):6282–6293 Jaccard G, Wimperis S, Bodenhausen G (1986) Multiple-quantum NMR spectroscopy of S = 3/2 spins in isotropic phase: a new probe for multiexponential relaxation. J Chem Phys 85(11):6282–6293
117.
go back to reference Chung CW, Wimperis S (1990) Optimum detection of spin-3/2 biexponential relaxation using multiple-quantum filtration techniques. J Magn Reson (1969) 88(2):440–447 Chung CW, Wimperis S (1990) Optimum detection of spin-3/2 biexponential relaxation using multiple-quantum filtration techniques. J Magn Reson (1969) 88(2):440–447
118.
go back to reference Wimperis S, Cole P, Styles P (1992) Triple-quantum-filtration NMR imaging of 200 mM sodium at 1.9 Tesla. J Magn Reson (1969) 98(3):628–636 Wimperis S, Cole P, Styles P (1992) Triple-quantum-filtration NMR imaging of 200 mM sodium at 1.9 Tesla. J Magn Reson (1969) 98(3):628–636
119.
go back to reference Hancu I, Boada FE, Shen GX (1999) Three-dimensional triple-quantum-filtered 23Na imaging of in vivo human brain. Magn Reson Med 42(6):1146–1154PubMed Hancu I, Boada FE, Shen GX (1999) Three-dimensional triple-quantum-filtered 23Na imaging of in vivo human brain. Magn Reson Med 42(6):1146–1154PubMed
120.
go back to reference Maudsley AA, Wokaun A, Ernst RR (1978) Coherence transfer echoes. Chem Phys Lett 55(1):9–14 Maudsley AA, Wokaun A, Ernst RR (1978) Coherence transfer echoes. Chem Phys Lett 55(1):9–14
121.
go back to reference Wimperis S, Wood B (1991) Triple-quantum sodium imaging. J Magn Reson (1969) 95(2):428–436 Wimperis S, Wood B (1991) Triple-quantum sodium imaging. J Magn Reson (1969) 95(2):428–436
122.
go back to reference Keltner JR, Wong ST, Roos MS (1994) Three-dimensional triple-quantum-filtered imaging of 0.012 and 0.024 M sodium-23 using short repetition times. J Magn Reson B 104(3):219–229PubMed Keltner JR, Wong ST, Roos MS (1994) Three-dimensional triple-quantum-filtered imaging of 0.012 and 0.024 M sodium-23 using short repetition times. J Magn Reson B 104(3):219–229PubMed
123.
go back to reference Zhu JM, Smith ICP (1995) Selection of coherence transfer pathways by pulsed-field gradients in NMR spectroscopy. Concept Magn Res 7(4):281–291 Zhu JM, Smith ICP (1995) Selection of coherence transfer pathways by pulsed-field gradients in NMR spectroscopy. Concept Magn Res 7(4):281–291
124.
go back to reference Tanase C, Boada FE (2005) Triple-quantum-filtered imaging of sodium in presence of B 0 inhomogeneities. J Magn Reson 174(2):270–278PubMed Tanase C, Boada FE (2005) Triple-quantum-filtered imaging of sodium in presence of B 0 inhomogeneities. J Magn Reson 174(2):270–278PubMed
125.
go back to reference Matthies C, Nagel AM, Schad LR, Bachert P (2010) Reduction of B 0 inhomogeneity effects in triple-quantum-filtered sodium imaging. J Magn Reson 202(2):239–244PubMed Matthies C, Nagel AM, Schad LR, Bachert P (2010) Reduction of B 0 inhomogeneity effects in triple-quantum-filtered sodium imaging. J Magn Reson 202(2):239–244PubMed
126.
go back to reference Fleysher L, Oesingmann N, Inglese M (2010) B 0 inhomogeneity-insensitive triple-quantum-filtered sodium imaging using a 12-step phase-cycling scheme. NMR Biomed 23(10):1191–1198PubMedCentralPubMed Fleysher L, Oesingmann N, Inglese M (2010) B 0 inhomogeneity-insensitive triple-quantum-filtered sodium imaging using a 12-step phase-cycling scheme. NMR Biomed 23(10):1191–1198PubMedCentralPubMed
127.
go back to reference Tsang A, Stobbe RW, Beaulieu C (2013) Evaluation of B-inhomogeneity correction for triple-quantum-filtered sodium MRI of the human brain at 4.7T. J Magn Reson 230C:134–144 Tsang A, Stobbe RW, Beaulieu C (2013) Evaluation of B-inhomogeneity correction for triple-quantum-filtered sodium MRI of the human brain at 4.7T. J Magn Reson 230C:134–144
128.
go back to reference Fiege DP, Romanzetti S, Tse DH, Brenner D, Celik A, Felder J, Jon Shah N (2013) B 0 insensitive multiple-quantum resolved sodium imaging using a phase-rotation scheme. J Magn Reson 228:32–36PubMed Fiege DP, Romanzetti S, Tse DH, Brenner D, Celik A, Felder J, Jon Shah N (2013) B 0 insensitive multiple-quantum resolved sodium imaging using a phase-rotation scheme. J Magn Reson 228:32–36PubMed
129.
go back to reference Fiege DP, Romanzetti S, Mirkes CC, Brenner D, Shah NJ (2013) Simultaneous single-quantum and triple-quantum-filtered MRI of 23Na (SISTINA). Magn Reson Med 69(6):1691–1696PubMed Fiege DP, Romanzetti S, Mirkes CC, Brenner D, Shah NJ (2013) Simultaneous single-quantum and triple-quantum-filtered MRI of 23Na (SISTINA). Magn Reson Med 69(6):1691–1696PubMed
130.
go back to reference Benkhedah N, Bachert P, Semmler W, Nagel AM (2012) Three-dimensional biexponential weighted 23Na imaging of the human brain with higher SNR and shorter acquisition time. Magn Reson Med. doi:10.1002/mrm.24516 PubMed Benkhedah N, Bachert P, Semmler W, Nagel AM (2012) Three-dimensional biexponential weighted 23Na imaging of the human brain with higher SNR and shorter acquisition time. Magn Reson Med. doi:10.​1002/​mrm.​24516 PubMed
131.
go back to reference Atkinson IC, Renteria L, Burd H, Pliskin NH, Thulborn KR (2007) Safety of human MRI at static fields above the FDA 8 T guideline: sodium imaging at 9.4 T does not affect vital signs or cognitive ability. J Magn Reson Imaging 26(5):1222–1227PubMed Atkinson IC, Renteria L, Burd H, Pliskin NH, Thulborn KR (2007) Safety of human MRI at static fields above the FDA 8 T guideline: sodium imaging at 9.4 T does not affect vital signs or cognitive ability. J Magn Reson Imaging 26(5):1222–1227PubMed
132.
go back to reference Nagel AM, Schmitter S, Bock M, Moser E, Semmler W, Schad LR (2009) Parameter optimization for 7T 23Na-MRI. In: Proceedings of the 17th scientific meeting, International Society for Magnetic Resonance in Medicine, Honolulu, p 2465 Nagel AM, Schmitter S, Bock M, Moser E, Semmler W, Schad LR (2009) Parameter optimization for 7T 23Na-MRI. In: Proceedings of the 17th scientific meeting, International Society for Magnetic Resonance in Medicine, Honolulu, p 2465
133.
go back to reference Hoult DI, Richards RE (1976) The signal-to-noise ratio of the nuclear magnetic resonance experiment. J Magn Reson (1969) 24(1):71–85 Hoult DI, Richards RE (1976) The signal-to-noise ratio of the nuclear magnetic resonance experiment. J Magn Reson (1969) 24(1):71–85
134.
go back to reference Lu M, Zhang Y, Ugurbil K, Chen W, Zhu XH (2013) In vitro and in vivo studies of (17) O NMR sensitivity at 9.4 and 16.4 T. Magn Reson Med 69(6):1523–1527PubMed Lu M, Zhang Y, Ugurbil K, Chen W, Zhu XH (2013) In vitro and in vivo studies of (17) O NMR sensitivity at 9.4 and 16.4 T. Magn Reson Med 69(6):1523–1527PubMed
135.
go back to reference Qian Y, Zhao T, Wiggins GC, Wald LL, Zheng H, Weimer J, Boada FE (2012) Sodium imaging of human brain at 7 T with 15-channel array coil. Magn Reson Med 68(6):1807–1814PubMed Qian Y, Zhao T, Wiggins GC, Wald LL, Zheng H, Weimer J, Boada FE (2012) Sodium imaging of human brain at 7 T with 15-channel array coil. Magn Reson Med 68(6):1807–1814PubMed
136.
go back to reference Idiyatullin D, Corum C, Park JY, Garwood M (2006) Fast and quiet MRI using a swept radiofrequency. J Magn Reson 181(2):342–349PubMed Idiyatullin D, Corum C, Park JY, Garwood M (2006) Fast and quiet MRI using a swept radiofrequency. J Magn Reson 181(2):342–349PubMed
137.
138.
go back to reference Nagel AM, Meise FM, Weber MA, Jurkat-Rott K, Lehmann-Horn F, Bock M, Semmler W, Umathum R (2012) Chlorine 35Cl magnetic resonance imaging of the human brain and muscle. In: Proceedings of the 20th scientific meeting, International Society for Magnetic Resonance in Medicine, Melbourne, p 1699 Nagel AM, Meise FM, Weber MA, Jurkat-Rott K, Lehmann-Horn F, Bock M, Semmler W, Umathum R (2012) Chlorine 35Cl magnetic resonance imaging of the human brain and muscle. In: Proceedings of the 20th scientific meeting, International Society for Magnetic Resonance in Medicine, Melbourne, p 1699
140.
go back to reference Atkinson IC, Claiborne TC, Thulborn KR (2013) Feasibility of 39-potassium MR imaging of a human brain at 9.4 Tesla. Magn Reson Med. doi:10.1002/mrm.24821 Atkinson IC, Claiborne TC, Thulborn KR (2013) Feasibility of 39-potassium MR imaging of a human brain at 9.4 Tesla. Magn Reson Med. doi:10.​1002/​mrm.​24821
Metadata
Title
Measurement techniques for magnetic resonance imaging of fast relaxing nuclei
Authors
Simon Konstandin
Armin M. Nagel
Publication date
01-02-2014
Publisher
Springer Berlin Heidelberg
Published in
Magnetic Resonance Materials in Physics, Biology and Medicine / Issue 1/2014
Print ISSN: 0968-5243
Electronic ISSN: 1352-8661
DOI
https://doi.org/10.1007/s10334-013-0394-3

Other articles of this Issue 1/2014

Magnetic Resonance Materials in Physics, Biology and Medicine 1/2014 Go to the issue