Skip to main content
Top
Published in: Hernia 5/2016

01-10-2016 | Original Article

Corona mortis: in vivo anatomical knowledge and the risk of injury in totally extraperitoneal inguinal hernia repair

Authors: M. Ates, E. Kinaci, E. Kose, V. Soyer, B. Sarici, S. Cuglan, F. Korkmaz, A. Dirican

Published in: Hernia | Issue 5/2016

Login to get access

Abstract

Purpose

Corona mortis (CMOR) is the arterial and/or venous vascular communication(s) between the obturator and external iliac vessels. Totally extraperitoneal (TEP) inguinal hernioplasty can be associated with vascular complications especially during the fixation of the mesh. Theoretically, CMOR is an important nominee. But, the data in literature are insufficient about CMOR injury. Additionally, most of the studies about CMOR have been usually performed on cadavers. We aimed to reveal the preperitoneal vascular anatomy of inguinal area and provide in vivo knowledge about CMOR. The risk of arterial injury was also evaluated.

Materials

The data of preperitoneal vascular anatomy of 321 patients who underwent TEP procedure between January 2005 and July 2014 were retrospectively evaluated.

Results

Mean age was 46 ± 8.9 years, 53 females vs 268 males. 391 hemipelvises were evaluated. Two types of arterial structure were identified; (1) an aberrant obturator artery forming an anastomosis with branches of ordinary obturator artery; (2) a pubic branch of inferior epigastric artery. The incidence of arterial CMOR was 28.4 % and of any arterial structure was 45.0 %. An arterial CMOR was considered as thick (≥2 mm) or thin (<2 mm). Injury of arterial CMOR during tack stapling on Cooper’s ligament was seen in six cases (1.5 %). All of them were thin (<2 mm) in structure. Venous CMOR was visible only under low pressure in work space.

Conclusion

During TEP hernia repair, CMOR and/or pubic branch of inferior epigastric artery can be damaged. To prevent this complication, tacks should be stapled to Cooper’s ligament close to symphysis pubis and dissection should be careful on the posterior surface of superior pubic ramus. Small caliber (<2 mm) arterial CMOR is more prone to be injured during TEP procedure. To explore venous structures properly, pressure in workspace should be kept as low as possible.
Literature
2.
go back to reference Berberoğlu M, Uz A, Ozmen MM, Bozkurt MC, Erkuran C, Taner S, Tekin A, Tekdemir I (2001) Corona mortis: an anatomic study in seven cadavers and an endoscopic study in 28 patients. Surg Endosc 15:72–75CrossRefPubMed Berberoğlu M, Uz A, Ozmen MM, Bozkurt MC, Erkuran C, Taner S, Tekin A, Tekdemir I (2001) Corona mortis: an anatomic study in seven cadavers and an endoscopic study in 28 patients. Surg Endosc 15:72–75CrossRefPubMed
4.
go back to reference Darmanis S, Lewis A, Mansoor A, Bircher M (2007) Corona mortis: an anatomical study with clinical implications in approaches to the pelvis and acetabulum. Clin Anat 20:433–439. doi:10.1002/ca.20390 CrossRefPubMed Darmanis S, Lewis A, Mansoor A, Bircher M (2007) Corona mortis: an anatomical study with clinical implications in approaches to the pelvis and acetabulum. Clin Anat 20:433–439. doi:10.​1002/​ca.​20390 CrossRefPubMed
5.
go back to reference Sarikcioglu L, Sindel M, Akyildiz F, Gur S (2003) Anastomotic vessels in the retropubic region: corona mortis. Folia Morphol (Warsz) 62:179–182 Sarikcioglu L, Sindel M, Akyildiz F, Gur S (2003) Anastomotic vessels in the retropubic region: corona mortis. Folia Morphol (Warsz) 62:179–182
9.
go back to reference Garrido-Gómez J, Pena-Rodríguez C, Martín-Noguerol T, Hernández-Cortes P (2012) Corona mortis artery avulsion due to a stable pubic ramus fracture. Orthopedics 35:80–82. doi:10.3928/01477447-20111122-25 Garrido-Gómez J, Pena-Rodríguez C, Martín-Noguerol T, Hernández-Cortes P (2012) Corona mortis artery avulsion due to a stable pubic ramus fracture. Orthopedics 35:80–82. doi:10.​3928/​01477447-20111122-25
12.
go back to reference Ramser M, Messmer AS, Zbinden I, Von Holzen U, Nebiker CA (2014) Incarcerated obturator hernia-laparoscopic repair with intraoperative view of the corona mortis. J Surg Case Rep 25:2014. doi:10.1093/jscr/rju081 Ramser M, Messmer AS, Zbinden I, Von Holzen U, Nebiker CA (2014) Incarcerated obturator hernia-laparoscopic repair with intraoperative view of the corona mortis. J Surg Case Rep 25:2014. doi:10.​1093/​jscr/​rju081
13.
go back to reference Moreno-Egea A, Paredes PG, Perello JM, Campillo-Soto A, Baena EG, Muñoz JR, Aguayo-Albasini JL (2010) Vascular injury by tacks during totally extraperitoneal endoscopic inguinal hernioplasty. Surg Laparosc Endosc Percutan Tech 20:129–131. doi:10.1097/SLE.0b013e3181df22a8 CrossRef Moreno-Egea A, Paredes PG, Perello JM, Campillo-Soto A, Baena EG, Muñoz JR, Aguayo-Albasini JL (2010) Vascular injury by tacks during totally extraperitoneal endoscopic inguinal hernioplasty. Surg Laparosc Endosc Percutan Tech 20:129–131. doi:10.​1097/​SLE.​0b013e3181df22a8​ CrossRef
14.
go back to reference Poelman MM, van den Heuvel B, Deelder JD, Abis GS, Beudeker N, Bittner RR, Campanelli G, van Dam D, Dwars BJ, Eker HH, Fingerhut A, Khatkov I, Koeckerling F, Kukleta JF, Miserez M, Montgomery A, Munoz Brands RM, Morales Conde S, Muysoms FE, Soltes M, Tromp W, Yavuz Y, Bonjer HJ (2013) EAES consensus development conference on endoscopic repair of groin hernias. Surg Endosc 27:3505–3519. doi:10.1007/s00464-013-3001-9 CrossRefPubMed Poelman MM, van den Heuvel B, Deelder JD, Abis GS, Beudeker N, Bittner RR, Campanelli G, van Dam D, Dwars BJ, Eker HH, Fingerhut A, Khatkov I, Koeckerling F, Kukleta JF, Miserez M, Montgomery A, Munoz Brands RM, Morales Conde S, Muysoms FE, Soltes M, Tromp W, Yavuz Y, Bonjer HJ (2013) EAES consensus development conference on endoscopic repair of groin hernias. Surg Endosc 27:3505–3519. doi:10.​1007/​s00464-013-3001-9 CrossRefPubMed
16.
go back to reference Pick JW, Anson BJ, Ashley FL (1942) The origin of the obturator artery: a study of 640 body-halves. Am J Anat 70:317–343CrossRef Pick JW, Anson BJ, Ashley FL (1942) The origin of the obturator artery: a study of 640 body-halves. Am J Anat 70:317–343CrossRef
18.
go back to reference Colborn GL, Skandalakis JE (1998) Laparoscopic inguinal anatomy. Hernia 2:179–191CrossRef Colborn GL, Skandalakis JE (1998) Laparoscopic inguinal anatomy. Hernia 2:179–191CrossRef
20.
go back to reference Tornetta P 3rd, Hochwald N, Levine R (1996) Corona mortis. Incidence and location. Clin Orthop Relat Res 329:97–101CrossRefPubMed Tornetta P 3rd, Hochwald N, Levine R (1996) Corona mortis. Incidence and location. Clin Orthop Relat Res 329:97–101CrossRefPubMed
21.
go back to reference Hong HX, Pan ZJ, Chen X, Huang ZJ (2004) An anatomical study of corona mortis and its clinical significance. Chin J Traumatol 7:165–169PubMed Hong HX, Pan ZJ, Chen X, Huang ZJ (2004) An anatomical study of corona mortis and its clinical significance. Chin J Traumatol 7:165–169PubMed
22.
go back to reference Lu CK, Lee YC, Sun PL, Liang CL, Liliang PC (2010) Life-threatening bleeding from the pubic branch of the inferior epigastric artery after pubic ramus fracture. Hong Kong J Emerg Med 17:372–376 Lu CK, Lee YC, Sun PL, Liang CL, Liliang PC (2010) Life-threatening bleeding from the pubic branch of the inferior epigastric artery after pubic ramus fracture. Hong Kong J Emerg Med 17:372–376
23.
go back to reference Meyers TJ, Smith WR, Ferrari JD, Morgan SJ, Franciose RJ, Echeverri JA (2000) Avulsion of the pubic branch of the inferior epigastric artery: a cause of hemodynamic instability in minimally displaced fractures of the pubic rami. J Trauma 49:750–753CrossRefPubMed Meyers TJ, Smith WR, Ferrari JD, Morgan SJ, Franciose RJ, Echeverri JA (2000) Avulsion of the pubic branch of the inferior epigastric artery: a cause of hemodynamic instability in minimally displaced fractures of the pubic rami. J Trauma 49:750–753CrossRefPubMed
Metadata
Title
Corona mortis: in vivo anatomical knowledge and the risk of injury in totally extraperitoneal inguinal hernia repair
Authors
M. Ates
E. Kinaci
E. Kose
V. Soyer
B. Sarici
S. Cuglan
F. Korkmaz
A. Dirican
Publication date
01-10-2016
Publisher
Springer Paris
Published in
Hernia / Issue 5/2016
Print ISSN: 1265-4906
Electronic ISSN: 1248-9204
DOI
https://doi.org/10.1007/s10029-015-1444-8

Other articles of this Issue 5/2016

Hernia 5/2016 Go to the issue