01-08-2012 | Original Article

Evaluation of impression accuracy for a four-implant mandibular model—a digital approach

Authors: Michael Stimmelmayr, Kurt Erdelt, Jan-Frederik Güth, Arndt Happe, Florian Beuer

Published in: Clinical Oral Investigations | Issue 4/2012

Login to get access

Abstract

Implant-supported prosthodontics requires precise impressions to achieve a passive fit. Since the early 1990s, in vitro studies comparing different implant impression techniques were performed, capturing the data mostly mechanically. The purpose of this study was to evaluate the accuracy of three different impression techniques digitally. Dental implants were inserted bilaterally in ten polymer lower-arch models at the positions of the first molars and canines. From each original model, three different impressions (A, transfer; B, pick-up; and C, splinted pick-up) were taken. Scan-bodies were mounted on the implants of the polymer and on the lab analogues of the stone models and digitized. The scan-body in position 36 (FDI) of the digitized original and master casts were each superimposed, and the deviations of the remaining three scan-bodies were measured three-dimensionally. The systematic error of digitizing the models was 13 μm for the polymer and 5 μm for the stone model. The mean discrepancies of the original model to the stone casts were 124 μm (±34) μm for the transfer technique, 116 (±46) μm for the pick-up technique, and 80 (±25) μm for the splinted pick-up technique. There were statistically significant discrepancies between the evaluated impression techniques (p ≤ 0.025; ANOVA test). The splinted pick-up impression showed the least deviation between original and stone model; transfer and pick-up techniques showed similar results. For better accuracy of implant-supported prosthodontics, the splinted pick-up technique should be used for impressions of four implants evenly spread in edentulous jaws.
Literature
1.
go back to reference Kan JY, Rungcharassaeng K, Bohsali K, Goodacre CJ, Lang BR (1999) Clinical methods for evaluating implant framework fit. J Prosthet Dent 81:7–13PubMedCrossRef Kan JY, Rungcharassaeng K, Bohsali K, Goodacre CJ, Lang BR (1999) Clinical methods for evaluating implant framework fit. J Prosthet Dent 81:7–13PubMedCrossRef
2.
go back to reference Cheshire PD, Hobkirk JA (1996) An in vivo quantitative analysis of the fit of Nobel Biocare implant superstructures. J Oral Rehabil 23:782–789PubMedCrossRef Cheshire PD, Hobkirk JA (1996) An in vivo quantitative analysis of the fit of Nobel Biocare implant superstructures. J Oral Rehabil 23:782–789PubMedCrossRef
3.
go back to reference Sahin S, Cehreli MC (2001) The significance of passive framework fit in implant prosthodontics: current status. Implant Dent 10:85–92PubMedCrossRef Sahin S, Cehreli MC (2001) The significance of passive framework fit in implant prosthodontics: current status. Implant Dent 10:85–92PubMedCrossRef
4.
go back to reference Kallus T, Bessing C (1994) Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implant 9:169–178 Kallus T, Bessing C (1994) Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implant 9:169–178
5.
6.
go back to reference Assuncao WG, Filho HG, Zaniquelli O (2004) Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent 13:358–366PubMed Assuncao WG, Filho HG, Zaniquelli O (2004) Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent 13:358–366PubMed
7.
go back to reference Carr AB (1991) Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implant 6:448–455 Carr AB (1991) Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implant 6:448–455
8.
go back to reference Assuncao WG, Britto RC, Ricardo Barao VA, Delben JA, dos Santos PH (2010) Evaluation of impression accuracy for implant at various angulations. Implant Dent 19:167–174PubMedCrossRef Assuncao WG, Britto RC, Ricardo Barao VA, Delben JA, dos Santos PH (2010) Evaluation of impression accuracy for implant at various angulations. Implant Dent 19:167–174PubMedCrossRef
9.
go back to reference Sorrentino R, Gherlone EF, Calesini G, Zarone F (2010) Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study. Clin Implant Dent Relat Res 12(Suppl 1):e63–e76PubMed Sorrentino R, Gherlone EF, Calesini G, Zarone F (2010) Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study. Clin Implant Dent Relat Res 12(Suppl 1):e63–e76PubMed
10.
go back to reference (2000) State of industry. Lab Manage Today 16:9–15. (2000) State of industry. Lab Manage Today 16:9–15.
11.
go back to reference Lee H, So JS, Hochstedler JL, Ercoli C (2008) The accuracy of implant impressions: a systematic review. J Prosthet Dent 100:285–291PubMedCrossRef Lee H, So JS, Hochstedler JL, Ercoli C (2008) The accuracy of implant impressions: a systematic review. J Prosthet Dent 100:285–291PubMedCrossRef
12.
go back to reference Al-Bakri IA, Hussey D, Al-Omari WM (2007) The dimensional accuracy of four impression techniques with the use of addition silicone impression materials. J Clin Dent 18:29–33PubMed Al-Bakri IA, Hussey D, Al-Omari WM (2007) The dimensional accuracy of four impression techniques with the use of addition silicone impression materials. J Clin Dent 18:29–33PubMed
13.
go back to reference Spector MR, Donovan TE, Nicholls JI (1990) An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 63:444–447PubMedCrossRef Spector MR, Donovan TE, Nicholls JI (1990) An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 63:444–447PubMedCrossRef
14.
go back to reference Hsu CC, Millstein PL, Stein RS (1993) A comparative analysis of the accuracy of implant transfer techniques. J Prosthet Dent 69:588–593PubMedCrossRef Hsu CC, Millstein PL, Stein RS (1993) A comparative analysis of the accuracy of implant transfer techniques. J Prosthet Dent 69:588–593PubMedCrossRef
15.
go back to reference Harder S, Dimaczek B, Acil Y, Terheyden H, Freitag-Wolf S, Kern M (2010) Molecular leakage at implant-abutment connection—in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration. Clin Oral Investig 14:427–432PubMedCrossRef Harder S, Dimaczek B, Acil Y, Terheyden H, Freitag-Wolf S, Kern M (2010) Molecular leakage at implant-abutment connection—in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration. Clin Oral Investig 14:427–432PubMedCrossRef
16.
go back to reference Steinebrunner L, Wolfart S, Ludwig K, Kern M (2008) Implant-abutment interface design affects fatigue and fracture strength of implants. Clin Oral Implants Res 19:1276–1284PubMedCrossRef Steinebrunner L, Wolfart S, Ludwig K, Kern M (2008) Implant-abutment interface design affects fatigue and fracture strength of implants. Clin Oral Implants Res 19:1276–1284PubMedCrossRef
17.
go back to reference Aloise JP, Curcio R, Laporta MZ, Rossi L, da Silva AM, Rapoport A (2010) Microbial leakage through the implant-abutment interface of Morse taper implants in vitro. Clin Oral Implants Res 21:328–335PubMedCrossRef Aloise JP, Curcio R, Laporta MZ, Rossi L, da Silva AM, Rapoport A (2010) Microbial leakage through the implant-abutment interface of Morse taper implants in vitro. Clin Oral Implants Res 21:328–335PubMedCrossRef
18.
go back to reference Semper W, Heberer S, Mehrhof J, Schink T, Nelson K (2010) Effects of repeated manual disassembly and reassembly on the positional stability of various implant-abutment complexes: an experimental study. Int J Oral Maxillofac Implant 25:86–94 Semper W, Heberer S, Mehrhof J, Schink T, Nelson K (2010) Effects of repeated manual disassembly and reassembly on the positional stability of various implant-abutment complexes: an experimental study. Int J Oral Maxillofac Implant 25:86–94
19.
go back to reference Vigolo P, Fonzi F, Majzoub Z, Cordioli G (2004) An evaluation of impression techniques for multiple internal connection implant prostheses. J Prosthet Dent 92:470–476PubMedCrossRef Vigolo P, Fonzi F, Majzoub Z, Cordioli G (2004) An evaluation of impression techniques for multiple internal connection implant prostheses. J Prosthet Dent 92:470–476PubMedCrossRef
20.
go back to reference Kim S, Nicholls JI, Han CH, Lee KW (2006) Displacement of implant components from impressions to definitive casts. Int J Oral Maxillofac Implant 21:747–755 Kim S, Nicholls JI, Han CH, Lee KW (2006) Displacement of implant components from impressions to definitive casts. Int J Oral Maxillofac Implant 21:747–755
21.
go back to reference Cabral LM, Guedes CG (2007) Comparative analysis of 4 impression techniques for implants. Implant Dent 16:187–194PubMedCrossRef Cabral LM, Guedes CG (2007) Comparative analysis of 4 impression techniques for implants. Implant Dent 16:187–194PubMedCrossRef
22.
go back to reference Del'Acqua MA, Chavez AM, Compagnoni MA, Molo Fde A Jr (2010) Accuracy of impression techniques for an implant-supported prosthesis. Int J Oral Maxillofac Implant 25:715–721 Del'Acqua MA, Chavez AM, Compagnoni MA, Molo Fde A Jr (2010) Accuracy of impression techniques for an implant-supported prosthesis. Int J Oral Maxillofac Implant 25:715–721
23.
go back to reference Luthardt RG, Walter MH, Quaas S, Koch R, Rudolph H (2010) Comparison of the three-dimensional correctness of impression techniques: a randomized controlled trial. Quintessence Int 41:845–853PubMed Luthardt RG, Walter MH, Quaas S, Koch R, Rudolph H (2010) Comparison of the three-dimensional correctness of impression techniques: a randomized controlled trial. Quintessence Int 41:845–853PubMed
24.
go back to reference Stimmelmayr M, Güth JF, Erdelt K, Edelhoff D, Beuer F (2010) Digital evaluationof the reproducibility of implant scan-body fit—an in vitro study. Clin Oral Investig. doi:10.1007/s00784-011-0564-5 Stimmelmayr M, Güth JF, Erdelt K, Edelhoff D, Beuer F (2010) Digital evaluationof the reproducibility of implant scan-body fit—an in vitro study. Clin Oral Investig. doi:10.​1007/​s00784-011-0564-5
25.
go back to reference Barrett MG, de Rijk WG, Burgess JO (1993) The accuracy of six impression techniques for osseointegrated implants. J Prosthodont 2:75–82PubMedCrossRef Barrett MG, de Rijk WG, Burgess JO (1993) The accuracy of six impression techniques for osseointegrated implants. J Prosthodont 2:75–82PubMedCrossRef
26.
go back to reference Del'Acqua MA, Arioli-Filho JN, Compagnoni MA, Mollo Fde A Jr (2008) Accuracy of impression and pouring techniques for an implant-supported prosthesis. Int J Oral Maxillofac Implant 23:226–236 Del'Acqua MA, Arioli-Filho JN, Compagnoni MA, Mollo Fde A Jr (2008) Accuracy of impression and pouring techniques for an implant-supported prosthesis. Int J Oral Maxillofac Implant 23:226–236
27.
go back to reference Herbst D, Nel JC, Driessen CH, Becker PJ (2000) Evaluation of impression accuracy for osseointegrated implant supported superstructures. J Prosthet Dent 83:555–561PubMedCrossRef Herbst D, Nel JC, Driessen CH, Becker PJ (2000) Evaluation of impression accuracy for osseointegrated implant supported superstructures. J Prosthet Dent 83:555–561PubMedCrossRef
28.
go back to reference Humphries RM, Yaman P, Bloem TJ (1990) The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implant 5:331–336 Humphries RM, Yaman P, Bloem TJ (1990) The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implant 5:331–336
29.
go back to reference Naconecy MM, Teixeira ER, Shinkai RS, Frasca LC, Cervieri A (2004) Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments. Int J Oral Maxillofac Implant 19:192–198 Naconecy MM, Teixeira ER, Shinkai RS, Frasca LC, Cervieri A (2004) Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments. Int J Oral Maxillofac Implant 19:192–198
30.
go back to reference Carr AB (1992) Comparison of impression techniques for a two-implant 15-degree divergent model. Int J Oral Maxillofac Implant 7:468–475 Carr AB (1992) Comparison of impression techniques for a two-implant 15-degree divergent model. Int J Oral Maxillofac Implant 7:468–475
31.
go back to reference Conrad HJ, Pesun IJ, DeLong R, Hodges JS (2007) Accuracy of two impression techniques with angulated implants. J Prosthet Dent 97:349–356PubMedCrossRef Conrad HJ, Pesun IJ, DeLong R, Hodges JS (2007) Accuracy of two impression techniques with angulated implants. J Prosthet Dent 97:349–356PubMedCrossRef
32.
go back to reference Daoudi MF, Setchell DJ, Searson LJ (2004) An evaluation of three implant level impression techniques for single tooth implant. Eur J Prosthodont Restor Dent 12:9–14PubMed Daoudi MF, Setchell DJ, Searson LJ (2004) An evaluation of three implant level impression techniques for single tooth implant. Eur J Prosthodont Restor Dent 12:9–14PubMed
33.
go back to reference De La Cruz JE, Funkenbusch PD, Ercoli C, Moss ME, Graser GN, Tallents RH (2002) Verification jig for implant-supported prostheses: a comparison of standard impressions with verification jigs made of different materials. J Prosthet Dent 88:329–336CrossRef De La Cruz JE, Funkenbusch PD, Ercoli C, Moss ME, Graser GN, Tallents RH (2002) Verification jig for implant-supported prostheses: a comparison of standard impressions with verification jigs made of different materials. J Prosthet Dent 88:329–336CrossRef
34.
go back to reference Wenz HJ, Hertrampf K (2008) Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection. Int J Oral Maxillofac Implant 23:39–47 Wenz HJ, Hertrampf K (2008) Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection. Int J Oral Maxillofac Implant 23:39–47
35.
go back to reference Burawi G, Houston F, Byrne D, Claffey N (1997) A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system. J Prosthet Dent 77:68–75PubMedCrossRef Burawi G, Houston F, Byrne D, Claffey N (1997) A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system. J Prosthet Dent 77:68–75PubMedCrossRef
36.
go back to reference Inturregui JA, Aquilino SA, Ryther JS, Lund PS (1993) Evaluation of three impression techniques for osseointegrated oral implants. J Prosthet Dent 69:503–509PubMedCrossRef Inturregui JA, Aquilino SA, Ryther JS, Lund PS (1993) Evaluation of three impression techniques for osseointegrated oral implants. J Prosthet Dent 69:503–509PubMedCrossRef
37.
go back to reference Assif D, Fenton A, Zarb G, Schmitt A (1992) Comparative accuracy of implant impression procedures. Int J Periodontic Restor Dent 12:112–121 Assif D, Fenton A, Zarb G, Schmitt A (1992) Comparative accuracy of implant impression procedures. Int J Periodontic Restor Dent 12:112–121
38.
go back to reference Assif D, Marshak B, Schmidt A (1996) Accuracy of implant impression techniques. Int J Oral Maxillofac Implant 11:216–222 Assif D, Marshak B, Schmidt A (1996) Accuracy of implant impression techniques. Int J Oral Maxillofac Implant 11:216–222
39.
go back to reference Vigolo P, Majzoub Z, Cordioli G (2003) Evaluation of the accuracy of three techniques used for multiple implant abutment impressions. J Prosthet Dent 89:186–192PubMedCrossRef Vigolo P, Majzoub Z, Cordioli G (2003) Evaluation of the accuracy of three techniques used for multiple implant abutment impressions. J Prosthet Dent 89:186–192PubMedCrossRef
40.
go back to reference Choi JH, Lim YJ, Yim SH, Kim CW (2007) Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models. Int J Oral Maxillofac Implant 22:761–768 Choi JH, Lim YJ, Yim SH, Kim CW (2007) Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models. Int J Oral Maxillofac Implant 22:761–768
41.
go back to reference Del Corso M, Aba G, Vazquez L, Dargaud J, Dohan Ehrenfest DM (2009) Optical three-dimensional scanning acquisition of the position of osseointegrated implants: an in vitro study to determine method accuracy and operational feasibility. Clin Implant Dent Relat Res 11:214–221PubMedCrossRef Del Corso M, Aba G, Vazquez L, Dargaud J, Dohan Ehrenfest DM (2009) Optical three-dimensional scanning acquisition of the position of osseointegrated implants: an in vitro study to determine method accuracy and operational feasibility. Clin Implant Dent Relat Res 11:214–221PubMedCrossRef
42.
go back to reference Mehl A, Ender A, Mormann W, Attin T (2009) Accuracy testing of a new intraoral 3D camera. Int J Comput Dent 12:11–28PubMed Mehl A, Ender A, Mormann W, Attin T (2009) Accuracy testing of a new intraoral 3D camera. Int J Comput Dent 12:11–28PubMed
43.
go back to reference Ma T, Nicholls JI, Rubenstein JE (1997) Tolerance measurements of various implant components. Int J Oral Maxillofac Implant 12:371–375 Ma T, Nicholls JI, Rubenstein JE (1997) Tolerance measurements of various implant components. Int J Oral Maxillofac Implant 12:371–375
44.
go back to reference Semper W, Kraft S, Kruger T, Nelson K (2009) Theoretical considerations: implant positional index design. J Dent Res 88:725–730PubMedCrossRef Semper W, Kraft S, Kruger T, Nelson K (2009) Theoretical considerations: implant positional index design. J Dent Res 88:725–730PubMedCrossRef
45.
go back to reference Binon PP (2000) Implants and components: entering the new millennium. Int J Oral Maxillofac Implant 15:76–94 Binon PP (2000) Implants and components: entering the new millennium. Int J Oral Maxillofac Implant 15:76–94
46.
go back to reference Semper W, Kraft S, Kruger T, Nelson K (2009) Theoretical optimum of implant positional index design. J Dent Res 88:731–735PubMedCrossRef Semper W, Kraft S, Kruger T, Nelson K (2009) Theoretical optimum of implant positional index design. J Dent Res 88:731–735PubMedCrossRef
47.
go back to reference Semper W, Kraft S, Mehrhof J, Nelson K (2010) Impact of abutment rotation and angulation on marginal fit: theoretical considerations. Int J Oral Maxillofac Implant 25:752–758 Semper W, Kraft S, Mehrhof J, Nelson K (2010) Impact of abutment rotation and angulation on marginal fit: theoretical considerations. Int J Oral Maxillofac Implant 25:752–758
Metadata
Title
Evaluation of impression accuracy for a four-implant mandibular model—a digital approach
Authors
Michael Stimmelmayr
Kurt Erdelt
Jan-Frederik Güth
Arndt Happe
Florian Beuer
Publication date
01-08-2012
Publisher
Springer-Verlag
Published in
Clinical Oral Investigations / Issue 4/2012
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-011-0622-z

Other articles of this Issue 4/2012

Clinical Oral Investigations 4/2012 Go to the issue