Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 4/2019

01-05-2019 | Magnetic Resonance Imaging | Technical Note • ELBOW - ARTHROSCOPY

Outcomes of distal biceps tendon reattachment using the ToggleLoc™ fixation device with ZipLoop™ technology with single mini-open technique

Authors: Florie Alech-Tournier, Kamil Elkholti, Vincent Locquet, Michel Ninou, Nicolas Gibert, Marc Pozzetto, Frédéric Breden, Pascal Rostoucher, Antoine Marc, Lionel Erhard, Jérôme Vogels

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 4/2019

Login to get access

Abstract

Anatomical repair of distal biceps tendon ruptures has been shown to restore elbow supination and flexion strength. Here, we report the outcomes of distal biceps tendon reattachment using the ToggleLoc fixation device with ZipLoop technology through a single incision. This was a retrospective study of 38 patients with a mean age of 49.5 years. The mean follow-up time was 15 months (range 4/28). The average time to surgery was 21 days. The fixation button was introduced in a bone tunnel and the tendon passed through a bone window using the ToggleLoc™, which allows the tendon to be tensioned using sutures. The tendon was reattached in 30° elbow flexion. The mean strength deficit in supination was 23.9% in comparison with the contralateral side. We discovered four instances of heterotopic ossification on follow-up radiographs. There were seven cases of persistent lateral antebrachial cutaneous nerve paresthesia, but no damage to the posterior interosseous nerve. This new technique places the tendon in a bone tunnel using a single surgical approach. It provides the surgeon with good feedback on the tension of the repair, which is unique among endobutton-type devices. We recommend using the ToggleLoc™ with ZipLoop™ technology as it is a simple, reliable and reproducible technique for distal biceps tendon reattachment.
Literature
1.
go back to reference Athwal GS (2016) Management of elbow trauma, an issue of hand clinics 31-4, E-Book. Elsevier Health Sciences, New York Athwal GS (2016) Management of elbow trauma, an issue of hand clinics 31-4, E-Book. Elsevier Health Sciences, New York
2.
go back to reference Baker BE, Bierwagen D (1985) Rupture of the distal tendon of the biceps brachii. Operative versus non-operative treatment. J Bone Joint Surg Am 67:414–417CrossRefPubMed Baker BE, Bierwagen D (1985) Rupture of the distal tendon of the biceps brachii. Operative versus non-operative treatment. J Bone Joint Surg Am 67:414–417CrossRefPubMed
3.
go back to reference Baker CLJ, Plancher KD (2006) Operative treatment of elbow injuries. Springer, Berlin Baker CLJ, Plancher KD (2006) Operative treatment of elbow injuries. Springer, Berlin
4.
go back to reference Cain RA, Nydick JA, Stein MI, Williams BD, Polikandriotis JA, Hess AV (2012) Complications following distal biceps repair. J Hand Surg 37:2112–2117CrossRef Cain RA, Nydick JA, Stein MI, Williams BD, Polikandriotis JA, Hess AV (2012) Complications following distal biceps repair. J Hand Surg 37:2112–2117CrossRef
5.
go back to reference Chavan PR, Duquin TR, Bisson LJ (2008) Repair of the ruptured distal biceps tendon: a systematic review. Am J Sports Med 36:1618–1624CrossRefPubMed Chavan PR, Duquin TR, Bisson LJ (2008) Repair of the ruptured distal biceps tendon: a systematic review. Am J Sports Med 36:1618–1624CrossRefPubMed
6.
go back to reference D’Alessandro DF, Shields CL, Tibone JE, Chandler RW (1993) Repair of distal biceps tendon ruptures in athletes. Am J Sports Med 21:114–119CrossRefPubMed D’Alessandro DF, Shields CL, Tibone JE, Chandler RW (1993) Repair of distal biceps tendon ruptures in athletes. Am J Sports Med 21:114–119CrossRefPubMed
7.
go back to reference Dillon MT, Bollier MJ, King JC (2011) Repair of acute and chronic distal biceps tendon ruptures using the EndoButton. Hand N Y N 6:39–46CrossRef Dillon MT, Bollier MJ, King JC (2011) Repair of acute and chronic distal biceps tendon ruptures using the EndoButton. Hand N Y N 6:39–46CrossRef
8.
go back to reference DiRaimo MJ, Maney MD, Deitch JR (2008) Distal biceps tendon repair using the toggle loc with zip loop. Orthopedics 31:1201–1203CrossRef DiRaimo MJ, Maney MD, Deitch JR (2008) Distal biceps tendon repair using the toggle loc with zip loop. Orthopedics 31:1201–1203CrossRef
9.
go back to reference Greenberg JA, Fernandez JJ, Wang T, Turner C (2003) EndoButton-assisted repair of distal biceps tendon ruptures. J Shoulder Elbow Surg 12:484–490CrossRefPubMed Greenberg JA, Fernandez JJ, Wang T, Turner C (2003) EndoButton-assisted repair of distal biceps tendon ruptures. J Shoulder Elbow Surg 12:484–490CrossRefPubMed
10.
go back to reference Haute Autorité de Santé - Programmes de récupération améliorée après chirurgie (RAAC) Haute Autorité de Santé - Programmes de récupération améliorée après chirurgie (RAAC)
11.
go back to reference Keener JD (2011) Controversies in the surgical treatment of distal biceps tendon ruptures: single versus double-incision repairs. J Shoulder Elbow Surg 20:S113–S125CrossRefPubMed Keener JD (2011) Controversies in the surgical treatment of distal biceps tendon ruptures: single versus double-incision repairs. J Shoulder Elbow Surg 20:S113–S125CrossRefPubMed
12.
go back to reference Kodde IF, Bekerom MPJ van den, Eygendaal DE (2013) Reconstruction of distal biceps tendon ruptures with a cortical button. Knee Surg Sports Traumatol Arthrosc 23(3):919–925CrossRef Kodde IF, Bekerom MPJ van den, Eygendaal DE (2013) Reconstruction of distal biceps tendon ruptures with a cortical button. Knee Surg Sports Traumatol Arthrosc 23(3):919–925CrossRef
13.
go back to reference Lo EY, Li C-S, Van den Bogaerde JM (2011) The effect of drill trajectory on proximity to the posterior interosseous nerve during cortical button distal biceps repair. Arthrosc J Arthrosc Relat Surg Off Publ Arthrosc Assoc N Am Int Arthrosc Assoc 27:1048–1054CrossRef Lo EY, Li C-S, Van den Bogaerde JM (2011) The effect of drill trajectory on proximity to the posterior interosseous nerve during cortical button distal biceps repair. Arthrosc J Arthrosc Relat Surg Off Publ Arthrosc Assoc N Am Int Arthrosc Assoc 27:1048–1054CrossRef
14.
go back to reference Mazzocca AD, Burton KJ, Romeo AA, Santangelo S, Adams DA, Arciero RA (2007) Biomechanical evaluation of 4 techniques of distal biceps brachii tendon repair. Am J Sports Med 35:252–258CrossRefPubMed Mazzocca AD, Burton KJ, Romeo AA, Santangelo S, Adams DA, Arciero RA (2007) Biomechanical evaluation of 4 techniques of distal biceps brachii tendon repair. Am J Sports Med 35:252–258CrossRefPubMed
15.
go back to reference Morrey BF (2009) The elbow and its disorders. Elsevier Health Sciences, New York Morrey BF (2009) The elbow and its disorders. Elsevier Health Sciences, New York
16.
go back to reference Morrey ME, Abdel MP, Sanchez-Sotelo J, Morrey BF (2014) Primary repair of retracted distal biceps tendon ruptures in extreme flexion. J Shoulder Elbow Surg 23:679–685CrossRefPubMed Morrey ME, Abdel MP, Sanchez-Sotelo J, Morrey BF (2014) Primary repair of retracted distal biceps tendon ruptures in extreme flexion. J Shoulder Elbow Surg 23:679–685CrossRefPubMed
17.
go back to reference Peeters T, Ching-Soon NG, Jansen N, Sneyers C, Declercq G, Verstreken F (2009) Functional outcome after repair of distal biceps tendon ruptures using the endobutton technique. J Shoulder Elbow Surg 18:283–287CrossRefPubMed Peeters T, Ching-Soon NG, Jansen N, Sneyers C, Declercq G, Verstreken F (2009) Functional outcome after repair of distal biceps tendon ruptures using the endobutton technique. J Shoulder Elbow Surg 18:283–287CrossRefPubMed
18.
go back to reference Ramsey ML (1999) Distal biceps tendon injuries: diagnosis and management. J Am Acad Orthop Surg 7:199–207CrossRefPubMed Ramsey ML (1999) Distal biceps tendon injuries: diagnosis and management. J Am Acad Orthop Surg 7:199–207CrossRefPubMed
20.
go back to reference Rose DM, Archibald JD, Sutter EG, Belkoff SM, Wilckens JH (2011) Biomechanical analysis suggests early rehabilitation is possible after single-incision EndoButton distal biceps repair with FiberWire. Knee Surg Sports Traumatol Arthrosc Off J ESSKA 19:1019–1022CrossRef Rose DM, Archibald JD, Sutter EG, Belkoff SM, Wilckens JH (2011) Biomechanical analysis suggests early rehabilitation is possible after single-incision EndoButton distal biceps repair with FiberWire. Knee Surg Sports Traumatol Arthrosc Off J ESSKA 19:1019–1022CrossRef
21.
go back to reference Spang JT, Weinhold PS, Karas SG (2006) A biomechanical comparison of EndoButton versus suture anchor repair of distal biceps tendon injuries. J Shoulder Elbow Surg 15:509–514CrossRefPubMed Spang JT, Weinhold PS, Karas SG (2006) A biomechanical comparison of EndoButton versus suture anchor repair of distal biceps tendon injuries. J Shoulder Elbow Surg 15:509–514CrossRefPubMed
Metadata
Title
Outcomes of distal biceps tendon reattachment using the ToggleLoc™ fixation device with ZipLoop™ technology with single mini-open technique
Authors
Florie Alech-Tournier
Kamil Elkholti
Vincent Locquet
Michel Ninou
Nicolas Gibert
Marc Pozzetto
Frédéric Breden
Pascal Rostoucher
Antoine Marc
Lionel Erhard
Jérôme Vogels
Publication date
01-05-2019
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 4/2019
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-019-02376-9

Other articles of this Issue 4/2019

European Journal of Orthopaedic Surgery & Traumatology 4/2019 Go to the issue