Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 4/2015

01-05-2015 | General Review

Past and present of the use of cerclage wires in orthopedics

Authors: Andrea Angelini, Concetto Battiato

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 4/2015

Login to get access

Abstract

Cerclage wiring is a simple technique that has been practiced widely since the advent of surgical treatment of fractures. Many studies have reported the use of various cerclage technologies with a wide range of results and clinical applications. The increasing numbers of periprosthetic fractures have led to a revival of interest for this simple technique. When cerclages function as implants, they may be used alone or together with a protecting device such as external or internal splints (such as plates, nails, stems of prosthesis or a combination of thereof). This article presents a review of the available literature relating cerclage-wiring techniques and updates the recommendations for clinical use.
Literature
1.
go back to reference Evans PE (1983) Cerclage fixation of a fractured humerus in 1775. Fact or fiction? Clin Orthop 174:138–142PubMed Evans PE (1983) Cerclage fixation of a fractured humerus in 1775. Fact or fiction? Clin Orthop 174:138–142PubMed
2.
go back to reference Götze O (1933) Subcutane Drahnaht bei Tibiaschrägbrüchen. Arch Klin Chir 177:145 Götze O (1933) Subcutane Drahnaht bei Tibiaschrägbrüchen. Arch Klin Chir 177:145
3.
go back to reference Perren SM, Fernandez Dell’Oca A, Lenz M, Windolf M (2011) Cerclage, evolution and potential of a Cinderella technology. An overview with reference to periprosthetic fractures. Acta Chir Orthop Traumatol Cech 78(3):190–199PubMed Perren SM, Fernandez Dell’Oca A, Lenz M, Windolf M (2011) Cerclage, evolution and potential of a Cinderella technology. An overview with reference to periprosthetic fractures. Acta Chir Orthop Traumatol Cech 78(3):190–199PubMed
4.
go back to reference Lenz M, Perren SM, Gueorguiev B, Richards RG, Krause F, Fernandez Dell’Oca A, Höntzsch D, Windolf M (2012) Underneath the cerclage: an ex vivo study on the cerclage–bone interface mechanics. Arch Orthop Trauma Surg 132(10):1467–1472CrossRefPubMed Lenz M, Perren SM, Gueorguiev B, Richards RG, Krause F, Fernandez Dell’Oca A, Höntzsch D, Windolf M (2012) Underneath the cerclage: an ex vivo study on the cerclage–bone interface mechanics. Arch Orthop Trauma Surg 132(10):1467–1472CrossRefPubMed
5.
go back to reference Cheng SL, Smith TJ, Davey JR (1993) A comparison of the strength and stability of six techniques of cerclage wire fixation for fractures. J Orthop Trauma 7(3):222CrossRef Cheng SL, Smith TJ, Davey JR (1993) A comparison of the strength and stability of six techniques of cerclage wire fixation for fractures. J Orthop Trauma 7(3):222CrossRef
6.
go back to reference Habernek H, Walch G, Dengg C (1989) Cerclage for torsional fractures of the tibia. J Bone Joint Surg 71B:311–313 Habernek H, Walch G, Dengg C (1989) Cerclage for torsional fractures of the tibia. J Bone Joint Surg 71B:311–313
7.
go back to reference Soeur R (1981) Fractures of the limbs: the relationship between mechanism and treatment. Brussels: La. Clinique Orthopedique:542–3. 7 Soeur R (1981) Fractures of the limbs: the relationship between mechanism and treatment. Brussels: La. Clinique Orthopedique:542–3. 7
8.
go back to reference Schopfer A, Willett K, Powell J et al (1993) Cerclage wiring in internal fixation of acetabular fractures. J Orthop Trauma 7(3):236–241CrossRefPubMed Schopfer A, Willett K, Powell J et al (1993) Cerclage wiring in internal fixation of acetabular fractures. J Orthop Trauma 7(3):236–241CrossRefPubMed
10.
go back to reference Christensen CM, Seger BM, Schultz RB (1989) Management of intraoperative femur fractures associated with revision hip arthroplasty. Clin Orthop Rel Res 248:177–180 Christensen CM, Seger BM, Schultz RB (1989) Management of intraoperative femur fractures associated with revision hip arthroplasty. Clin Orthop Rel Res 248:177–180
11.
go back to reference Fitzgerald RH Jr, Brindley GW, Kavanagh BF (1988) The uncemented total hip arthroplasty: intraoperative femoral fractures. Clin Orthop Relat Res 235:61–66PubMed Fitzgerald RH Jr, Brindley GW, Kavanagh BF (1988) The uncemented total hip arthroplasty: intraoperative femoral fractures. Clin Orthop Relat Res 235:61–66PubMed
12.
go back to reference Berend K, Lombardi A, Mallory T et al (2004) Cerclage wires or cables for the management of intraoperative fracture associated with a cementless, tapered femoral prosthesis results at 2 to 16 years. J Arthroplast 19:17–21CrossRef Berend K, Lombardi A, Mallory T et al (2004) Cerclage wires or cables for the management of intraoperative fracture associated with a cementless, tapered femoral prosthesis results at 2 to 16 years. J Arthroplast 19:17–21CrossRef
13.
go back to reference Mayle RE Jr, Paprosky WG (2012) Massive bone loss: allograft-prosthetic composites and beyond. J Bone Joint Surg Br 94(11 Suppl A):61–64CrossRefPubMed Mayle RE Jr, Paprosky WG (2012) Massive bone loss: allograft-prosthetic composites and beyond. J Bone Joint Surg Br 94(11 Suppl A):61–64CrossRefPubMed
14.
go back to reference Duncan C, Masri B (1995) Fractures of the femur after hip replacement. Instr Course Lect 44:293–304PubMed Duncan C, Masri B (1995) Fractures of the femur after hip replacement. Instr Course Lect 44:293–304PubMed
15.
go back to reference McCulloch RS, Roe SC, Marcellin-Little DJ, Mente PL (2012) Resistance to subsidence of an uncemented femoral stem after cerclage wiring of a fissure. Vet Surg 41(1):163–167CrossRefPubMed McCulloch RS, Roe SC, Marcellin-Little DJ, Mente PL (2012) Resistance to subsidence of an uncemented femoral stem after cerclage wiring of a fissure. Vet Surg 41(1):163–167CrossRefPubMed
16.
go back to reference Mallory TH, Kraus TJ, Vaughn BK (1989) Intraoperative femoral fractures associated with cementless total hip arthroplasty. Orthopedics 12(2):231–239PubMed Mallory TH, Kraus TJ, Vaughn BK (1989) Intraoperative femoral fractures associated with cementless total hip arthroplasty. Orthopedics 12(2):231–239PubMed
17.
go back to reference Otani T, Whiteside LA, White SE, McCarthy DS (1995) Reaming technique of the femoral diaphysis in cementless total hip arthroplasty. Clin Orthop Relat Res 311:210–221PubMed Otani T, Whiteside LA, White SE, McCarthy DS (1995) Reaming technique of the femoral diaphysis in cementless total hip arthroplasty. Clin Orthop Relat Res 311:210–221PubMed
18.
go back to reference Zeh A, Radetzki F, Diers V, Bach D, Röllinghoff M, Delank KS (2011) Is there an increased stem migration or compromised osteointegration of the Mayo short-stemmed prosthesis following cerclage wiring of an intrasurgical periprosthetic fracture? Arch Orthop Trauma Surg 131(12):1717–1722CrossRefPubMed Zeh A, Radetzki F, Diers V, Bach D, Röllinghoff M, Delank KS (2011) Is there an increased stem migration or compromised osteointegration of the Mayo short-stemmed prosthesis following cerclage wiring of an intrasurgical periprosthetic fracture? Arch Orthop Trauma Surg 131(12):1717–1722CrossRefPubMed
19.
go back to reference Fishkin Z, Han S, Ziv I (1999) Cerclage wiring technique after proximal femoral fracture in total hip arthroplasty. J Arthroplast 14:98–101CrossRef Fishkin Z, Han S, Ziv I (1999) Cerclage wiring technique after proximal femoral fracture in total hip arthroplasty. J Arthroplast 14:98–101CrossRef
21.
go back to reference Cho SH, Lee SH, Cho HL, Ku JH, Choi JH, Lee AJ (2011) Additional fixations for sliding hip screws in treating unstable pertrochanteric femoral fractures (AO Type 31-A2): short-term clinical results. Clin Orthop Surg 3(2):107–113CrossRefPubMedCentralPubMed Cho SH, Lee SH, Cho HL, Ku JH, Choi JH, Lee AJ (2011) Additional fixations for sliding hip screws in treating unstable pertrochanteric femoral fractures (AO Type 31-A2): short-term clinical results. Clin Orthop Surg 3(2):107–113CrossRefPubMedCentralPubMed
22.
go back to reference Ban I, Birkelund L, Palm H, Brix M, Troelsen A (2012) Circumferential wires as a supplement to intramedullary nailing in unstable trochanteric hip fractures: 4 reoperations in 60 patients followed for 1 year. Acta Orthop 83(3):240–243CrossRefPubMedCentralPubMed Ban I, Birkelund L, Palm H, Brix M, Troelsen A (2012) Circumferential wires as a supplement to intramedullary nailing in unstable trochanteric hip fractures: 4 reoperations in 60 patients followed for 1 year. Acta Orthop 83(3):240–243CrossRefPubMedCentralPubMed
23.
go back to reference Kennedy MT, Mitra A, Hierlihy TG, Harty JA, Reidy D, Dolan M (2011) Subtrochanteric hip fractures treated with cerclage cables and long cephalomedullary nails: a review of 17 consecutive cases over 2 years. Injury 42:1317–1321CrossRefPubMed Kennedy MT, Mitra A, Hierlihy TG, Harty JA, Reidy D, Dolan M (2011) Subtrochanteric hip fractures treated with cerclage cables and long cephalomedullary nails: a review of 17 consecutive cases over 2 years. Injury 42:1317–1321CrossRefPubMed
24.
go back to reference Winquist RA, Hansen ST Jr, Clawson DK (1984) Closed intramedullary nailing of femoral fractures. A report of five hundred and twenty cases. J Bone Joint Surg Am 66(4):529–539PubMed Winquist RA, Hansen ST Jr, Clawson DK (1984) Closed intramedullary nailing of femoral fractures. A report of five hundred and twenty cases. J Bone Joint Surg Am 66(4):529–539PubMed
25.
go back to reference Roberts CS, Nawab A, Wang M, Voor MJ, Seligson D (2002) Second generation intramedullary nailing of subtrochanteric femur fractures: a biomechanical study of fracture site motion. J Orthop Trauma 16(4):231–238CrossRefPubMed Roberts CS, Nawab A, Wang M, Voor MJ, Seligson D (2002) Second generation intramedullary nailing of subtrochanteric femur fractures: a biomechanical study of fracture site motion. J Orthop Trauma 16(4):231–238CrossRefPubMed
26.
go back to reference Lin HH, Hung SH, Su YP, Chiu FY, Liu CL (2012) Cerclage wiring in displaced associated anterior column and posterior hemi-transverse acetabular fractures. Injury 43(6):917–920CrossRefPubMed Lin HH, Hung SH, Su YP, Chiu FY, Liu CL (2012) Cerclage wiring in displaced associated anterior column and posterior hemi-transverse acetabular fractures. Injury 43(6):917–920CrossRefPubMed
27.
go back to reference Chen CM, Chiu FY, Lo WH, Chung TY (2001) Cerclage wiring in displaced both-column fractures of the acetabulum. Injury 32(5):391–394CrossRefPubMed Chen CM, Chiu FY, Lo WH, Chung TY (2001) Cerclage wiring in displaced both-column fractures of the acetabulum. Injury 32(5):391–394CrossRefPubMed
28.
go back to reference Pike J, Davidson D, Garbuz D, Duncan CP, O’Brien PJ, Masri BA (2009) Principles of treatment for periprosthetic femoral shaft fractures around well-fixed total hip arthroplasty. J Am Acad Orthop Surg 17(11):677–688PubMed Pike J, Davidson D, Garbuz D, Duncan CP, O’Brien PJ, Masri BA (2009) Principles of treatment for periprosthetic femoral shaft fractures around well-fixed total hip arthroplasty. J Am Acad Orthop Surg 17(11):677–688PubMed
29.
go back to reference Johannsson JE, McBroom R, Barrington TW, Hunter GA (1981) Fracture of the ipsilateral femur in patients with total hip replacement. J Bone Joint Surg Am 63(9):1435–1442 Johannsson JE, McBroom R, Barrington TW, Hunter GA (1981) Fracture of the ipsilateral femur in patients with total hip replacement. J Bone Joint Surg Am 63(9):1435–1442
30.
go back to reference Dennis MG, Simon JA, Kummer FJ, Koval KJ, DiCesare PE (2000) Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of five techniques. J Arthroplast 15(4):523–528CrossRef Dennis MG, Simon JA, Kummer FJ, Koval KJ, DiCesare PE (2000) Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of five techniques. J Arthroplast 15(4):523–528CrossRef
31.
go back to reference Apivatthakakul T, Phaliphot J, Leuvitoonvechkit S (2013) Percutaneous cerclage wiring, does it disrupt femoral blood supply? A cadaveric injection study. Injury 44(2):168–174 Apivatthakakul T, Phaliphot J, Leuvitoonvechkit S (2013) Percutaneous cerclage wiring, does it disrupt femoral blood supply? A cadaveric injection study. Injury 44(2):168–174
32.
go back to reference Xue H, Tu Y, Cai M, Yang A (2011) Locking compression plate and cerclage band for type B1 periprosthetic femoral fractures preliminary results at average 30-month follow-up. J Arthroplast 26(3):467–471CrossRef Xue H, Tu Y, Cai M, Yang A (2011) Locking compression plate and cerclage band for type B1 periprosthetic femoral fractures preliminary results at average 30-month follow-up. J Arthroplast 26(3):467–471CrossRef
33.
go back to reference Younger TI, Bradford MS, Magnus RE et al (1995) Extended proximal femoral osteotomy. A new technique for femoral revision arthroplasty. J Arthroplast 10(3):329–338CrossRef Younger TI, Bradford MS, Magnus RE et al (1995) Extended proximal femoral osteotomy. A new technique for femoral revision arthroplasty. J Arthroplast 10(3):329–338CrossRef
34.
go back to reference Jakubowitz E, Kinkel S, Nadorf J, Heisel C, Kretzer JP, Thomsen MN (2011) The effect of multifilaments and monofilaments on cementless femoral revision hip components: an experimental study. Clin Biomech (Bristol, Avon) 26(3):257–261CrossRef Jakubowitz E, Kinkel S, Nadorf J, Heisel C, Kretzer JP, Thomsen MN (2011) The effect of multifilaments and monofilaments on cementless femoral revision hip components: an experimental study. Clin Biomech (Bristol, Avon) 26(3):257–261CrossRef
35.
go back to reference Schwab JH, Camacho J, Kaufman K, Chen Q, Berry DJ, Trousdale RT (2008) Optimal fixation for the extended trochanteric osteotomy: a pilot study comparing 3 cables vs 2 cables. J Arthroplast 23(4):534–538CrossRef Schwab JH, Camacho J, Kaufman K, Chen Q, Berry DJ, Trousdale RT (2008) Optimal fixation for the extended trochanteric osteotomy: a pilot study comparing 3 cables vs 2 cables. J Arthroplast 23(4):534–538CrossRef
36.
go back to reference Campbell JT, Moore RS, Iannotti JP, Norris TR, Williams GR (1998) Periprosthetic humeral fractures: mechanisms of fracture and treatment options. J Shoulder Elbow Surg 7:406–413CrossRefPubMed Campbell JT, Moore RS, Iannotti JP, Norris TR, Williams GR (1998) Periprosthetic humeral fractures: mechanisms of fracture and treatment options. J Shoulder Elbow Surg 7:406–413CrossRefPubMed
37.
go back to reference Mavrogenis AF, Angelini A, Guerra E, Papagelopoulos PJ, Ruggieri P, Rotini R (2009) Periprosthetic fractures of the humerus. J Long Term Eff Med Implants 19(4):305–311CrossRefPubMed Mavrogenis AF, Angelini A, Guerra E, Papagelopoulos PJ, Ruggieri P, Rotini R (2009) Periprosthetic fractures of the humerus. J Long Term Eff Med Implants 19(4):305–311CrossRefPubMed
38.
go back to reference Wutzler S, Laurer HL, Huhnstock S, Geiger EV, Buehren V, Marzi I (2009) Periprosthetic humeral fractures after shoulder arthroplasty: operative management and functional outcome. Arch Orthop Trauma Surg 129:237–243CrossRefPubMed Wutzler S, Laurer HL, Huhnstock S, Geiger EV, Buehren V, Marzi I (2009) Periprosthetic humeral fractures after shoulder arthroplasty: operative management and functional outcome. Arch Orthop Trauma Surg 129:237–243CrossRefPubMed
39.
go back to reference Cameron B, Iannotti JP (1999) Periprosthetic fractures of the humerus and scapula: management and prevention. Orthop Clin North Am 30:305–318CrossRefPubMed Cameron B, Iannotti JP (1999) Periprosthetic fractures of the humerus and scapula: management and prevention. Orthop Clin North Am 30:305–318CrossRefPubMed
40.
go back to reference Mavrogenis AF, Angelini A, Guerra E, Rotini R (2011) Humeral fracture between a total elbow and total shoulder arthroplasty. Orthopedics. 34(4) Mavrogenis AF, Angelini A, Guerra E, Rotini R (2011) Humeral fracture between a total elbow and total shoulder arthroplasty. Orthopedics. 34(4)
41.
go back to reference Choo A, Ramsey ML (2013) Total elbow arthroplasty: current options. J Am Acad Orthop Surg 21(7):427–437CrossRefPubMed Choo A, Ramsey ML (2013) Total elbow arthroplasty: current options. J Am Acad Orthop Surg 21(7):427–437CrossRefPubMed
42.
go back to reference Bostrom MP, Asnis SE, Ernberg JJ, Wright TM, Giddings VL, Berberian WS et al (1994) Fatigue testing of cerclage stainless steel wire fixation. J Orthop Trauma 8:422–428CrossRefPubMed Bostrom MP, Asnis SE, Ernberg JJ, Wright TM, Giddings VL, Berberian WS et al (1994) Fatigue testing of cerclage stainless steel wire fixation. J Orthop Trauma 8:422–428CrossRefPubMed
43.
go back to reference Shaw JA, Daubert HB (1988) Compression capability of cerclage fixation systems: a biomechanical study. Orthopedics 11:1169–1177PubMed Shaw JA, Daubert HB (1988) Compression capability of cerclage fixation systems: a biomechanical study. Orthopedics 11:1169–1177PubMed
44.
go back to reference Lenz M, Perren SM, Richards RG, Mückley T, Hofmann GO, Gueorguiev B, Windolf M (2013) Biomechanical performance of different cable and wire cerclage configurations. Int Orthop 37(1):125–130CrossRefPubMedCentralPubMed Lenz M, Perren SM, Richards RG, Mückley T, Hofmann GO, Gueorguiev B, Windolf M (2013) Biomechanical performance of different cable and wire cerclage configurations. Int Orthop 37(1):125–130CrossRefPubMedCentralPubMed
45.
go back to reference Ritter MA, Lutgring JD, Davis KE, Berend ME, Meding JB (2006) A clinical, radiographic, and cost comparison of cerclage techniques: wires vs cables. J Arthroplast 21(7):1064–1067CrossRef Ritter MA, Lutgring JD, Davis KE, Berend ME, Meding JB (2006) A clinical, radiographic, and cost comparison of cerclage techniques: wires vs cables. J Arthroplast 21(7):1064–1067CrossRef
46.
go back to reference Wähnert D, Lenz M, Schlegel U, Perren S, Windolf M (2011) Cerclage handling for improved fracture treatment. A biomechanical study on the twisting procedure. Acta Chir Orthop Traumatol Cech 78(3):208–214PubMed Wähnert D, Lenz M, Schlegel U, Perren S, Windolf M (2011) Cerclage handling for improved fracture treatment. A biomechanical study on the twisting procedure. Acta Chir Orthop Traumatol Cech 78(3):208–214PubMed
47.
go back to reference Wilson JW (1987) Effect of cerclage wires on periosteal bone in growing dogs. Vet Surg 16(4):299–302CrossRefPubMed Wilson JW (1987) Effect of cerclage wires on periosteal bone in growing dogs. Vet Surg 16(4):299–302CrossRefPubMed
48.
go back to reference Aleto T, Ritter M, Berend ME (2008) Case report: superficial femoral artery injury resulting from cerclage wiring during revision THA. Clin Orthop Relat Res 466(3):749–753CrossRefPubMedCentralPubMed Aleto T, Ritter M, Berend ME (2008) Case report: superficial femoral artery injury resulting from cerclage wiring during revision THA. Clin Orthop Relat Res 466(3):749–753CrossRefPubMedCentralPubMed
49.
go back to reference Biddau F, Fioriti M, Benelli G (2006) Migration of a broken cerclage wire from the patella into the heart. A case report. JBone Jt Surg Am 88(9):2057–2059CrossRef Biddau F, Fioriti M, Benelli G (2006) Migration of a broken cerclage wire from the patella into the heart. A case report. JBone Jt Surg Am 88(9):2057–2059CrossRef
50.
go back to reference Wirth MA, Lakoski SG, Rockwood CA Jr (2000) Migration of broken cerclage wire from the shoulder girdle into the heart: a case report. J Shoulder Elbow Surg 9:543–544CrossRefPubMed Wirth MA, Lakoski SG, Rockwood CA Jr (2000) Migration of broken cerclage wire from the shoulder girdle into the heart: a case report. J Shoulder Elbow Surg 9:543–544CrossRefPubMed
Metadata
Title
Past and present of the use of cerclage wires in orthopedics
Authors
Andrea Angelini
Concetto Battiato
Publication date
01-05-2015
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 4/2015
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-014-1520-2

Other articles of this Issue 4/2015

European Journal of Orthopaedic Surgery & Traumatology 4/2015 Go to the issue