Skip to main content
Top
Published in: European Spine Journal 10/2022

10-06-2022 | Original Article

Radio-anatomical study of anterior–posterior placement sacroiliac screw channel

Authors: Tianfang Wang, Changbao Wei, Sanjun Gu, Yongwei Wu, Yu Liu, Yunhong Ma, Qudong Yin

Published in: European Spine Journal | Issue 10/2022

Login to get access

Abstract

Purpose

The outlet of the classic sacroiliac screw (SIS) cannot be precisely controlled by aiming devices, which may lead to malpositioned implants and neurovascular and visceral injury. This study aimed to radio-anatomically measure the parameters of the channel for anterior–posterior placement SIS (AP-SIS), which can be placed percutaneously with an aiming device.

Methods

Pelvic CT scan data of 80 healthy adults (40 males and 40 females) with an average age of 45 years (range 20–70 years) were collected. The length (L), width (W), height (H), cortical bone spacing (M), camber angle (E), anteversion angle (F), cross-sectional safety angle (P) and sagittal safety angle (Q) of the channel were measured by CT or Mimics software.

Results

The L, W, H, M, E, F, P and Q measures of S1 were 109.2 ± 8.0 mm, 18.5 ± 1.9 mm, 21.7 ± 1.7 mm, 8.1 ± 0.4 mm, 44.2 ± 3.2°, 42.4 ± 3.6°, 16.8 ± 1.1°, and 19.4 ± 2.0°, respectively, for S1, and 113.5 ± 9.4 mm, 18.2 ± 1.5 mm, 21.7 ± 1.7 mm, 7.7 ± 0.4 mm, 44.7 ± 3.2°, 31.2 ± 2.7°, 13.8 ± 1.0° and 15.4 ± 1.4°, respectively, for S2. Of the L measures, the intra-iliac segment was slightly longer than the intra-sacral segment. All parameters showed significant sex-related differences (p < 0.05).

Conclusion

The AP-SIS channels of S1-2 have sufficient width and length to accommodate a cancellous screw with a Φ 7.0–8.0 mm and a length 90–130 mm. The intra-iliac segment is a long channel screw with better mechanical properties over classic SIS.
Appendix
Available only for authorised users
Literature
1.
go back to reference Bousbaa H, Ouahidi M, Louaste J, Bennani M, Cherrad T, Jezzari H, Kasmaoui EH, Rachid K, Amhajji L (2017) Percutaneous iliosacral screw fixation in unstable pelvic fractures. Pan Afr Med J 27:244CrossRef Bousbaa H, Ouahidi M, Louaste J, Bennani M, Cherrad T, Jezzari H, Kasmaoui EH, Rachid K, Amhajji L (2017) Percutaneous iliosacral screw fixation in unstable pelvic fractures. Pan Afr Med J 27:244CrossRef
2.
go back to reference Tidwell J, Cho R, Reid JS, Boateng H, Copeland C, Sirlin E (2016) Percutaneous sacroiliac screw technique. J Orthop Trauma 30(Suppl 2):S19-20CrossRef Tidwell J, Cho R, Reid JS, Boateng H, Copeland C, Sirlin E (2016) Percutaneous sacroiliac screw technique. J Orthop Trauma 30(Suppl 2):S19-20CrossRef
3.
go back to reference Iorio JA, Jakoi AM, Rehman S (2015) Percutaneous sacroiliac screw fixation of the posterior pelvic ring. Orthop Clin North Am 46(4):511–521CrossRef Iorio JA, Jakoi AM, Rehman S (2015) Percutaneous sacroiliac screw fixation of the posterior pelvic ring. Orthop Clin North Am 46(4):511–521CrossRef
4.
go back to reference Roetman B, Ilchuk I, Khatib B, Goerigk U, Gothner M (2019) Precise sacroiliac joint screw insertion without computed tomography, digital volume tomography or navigation systems. Oper Orthop Traumatol 31(6):474–490CrossRef Roetman B, Ilchuk I, Khatib B, Goerigk U, Gothner M (2019) Precise sacroiliac joint screw insertion without computed tomography, digital volume tomography or navigation systems. Oper Orthop Traumatol 31(6):474–490CrossRef
5.
go back to reference Krappinger D, Lindtner RA, Benedikt S (2019) Preoperative planning and safe intraoperative placement of iliosacral screws under fluoroscopic control. Oper Orthop Traumatol 31(6):465–473CrossRef Krappinger D, Lindtner RA, Benedikt S (2019) Preoperative planning and safe intraoperative placement of iliosacral screws under fluoroscopic control. Oper Orthop Traumatol 31(6):465–473CrossRef
6.
go back to reference Khaled SA, Soliman OW (2015) Functional outcome of unstable pelvic ring injuries after iliosacral screw fixation: single versus two screw fixation. Eur J Trauma Emerg Surg 41(4):387–392CrossRef Khaled SA, Soliman OW (2015) Functional outcome of unstable pelvic ring injuries after iliosacral screw fixation: single versus two screw fixation. Eur J Trauma Emerg Surg 41(4):387–392CrossRef
7.
go back to reference Zwingmann J, Hauschild O, Bode G, Südkamp NP, Schmal H (2013) Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis. Arch Orthop Trauma Surg 133(9):1257–1265CrossRef Zwingmann J, Hauschild O, Bode G, Südkamp NP, Schmal H (2013) Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis. Arch Orthop Trauma Surg 133(9):1257–1265CrossRef
8.
go back to reference Elzohairy MM, Salama AM (2017) Open reduction internal fixation versus percutaneous iliosacral screw fixation for unstable posterior pelvic ring disruptions. Orthop Traumatol Surg Res 103(2):223–227CrossRef Elzohairy MM, Salama AM (2017) Open reduction internal fixation versus percutaneous iliosacral screw fixation for unstable posterior pelvic ring disruptions. Orthop Traumatol Surg Res 103(2):223–227CrossRef
9.
go back to reference Sun X, Li S, Qiu Y, Chen Z, Chen X, Xu L, Zhu Z (2018) Anatomical study of a novel iliosacral screw placement for sacrum-pelvis in adult via computed tomography reconstruction. Spine (Phila Pa 1976) 43(13):e740–e745CrossRef Sun X, Li S, Qiu Y, Chen Z, Chen X, Xu L, Zhu Z (2018) Anatomical study of a novel iliosacral screw placement for sacrum-pelvis in adult via computed tomography reconstruction. Spine (Phila Pa 1976) 43(13):e740–e745CrossRef
10.
go back to reference Hack J, Krügera MA, Aigner R, Ruchholtz S, Oberkircher L (2018) Cement-augmented sacroiliac screw fixation with cannulated versus perforated screws—a biomechanical study in an osteoporotic hemipelvis model. Injury 49(8):1520–1525CrossRef Hack J, Krügera MA, Aigner R, Ruchholtz S, Oberkircher L (2018) Cement-augmented sacroiliac screw fixation with cannulated versus perforated screws—a biomechanical study in an osteoporotic hemipelvis model. Injury 49(8):1520–1525CrossRef
11.
go back to reference Osterhoff G, Dodd AE, Unno F, Wong A, Amiri S, Lefaivre KA, Guy P (2016) Cement augmentation in sacroiliac screw fixation offers modest biomechanical advantages in a cadaver model. Clin Orthop Relat Res 474(11):2522–2530CrossRef Osterhoff G, Dodd AE, Unno F, Wong A, Amiri S, Lefaivre KA, Guy P (2016) Cement augmentation in sacroiliac screw fixation offers modest biomechanical advantages in a cadaver model. Clin Orthop Relat Res 474(11):2522–2530CrossRef
12.
go back to reference Suero EM, Greiner A, Becker CA, Cavalcanti Kußmaul A, Weidert S, Pfeufer D, Woiczinski M, Braun C, Flatz W, Böcker W, Kammerlander C (2021) Biomechanical stability of sacroiliac screw osteosynthesis with and without cement augmentation. Injury 52(10):2707–2711CrossRef Suero EM, Greiner A, Becker CA, Cavalcanti Kußmaul A, Weidert S, Pfeufer D, Woiczinski M, Braun C, Flatz W, Böcker W, Kammerlander C (2021) Biomechanical stability of sacroiliac screw osteosynthesis with and without cement augmentation. Injury 52(10):2707–2711CrossRef
13.
go back to reference Gao Z, Sun X, Chen C, Teng Z, Xu B, Ma X, Wang Z, Yang Q (2021) Comparative radiological outcomes and complications of sacral-2-alar iliac screw versus iliac screw for sacropelvic fixation. Eur Spine J 30(8):2257–2270CrossRef Gao Z, Sun X, Chen C, Teng Z, Xu B, Ma X, Wang Z, Yang Q (2021) Comparative radiological outcomes and complications of sacral-2-alar iliac screw versus iliac screw for sacropelvic fixation. Eur Spine J 30(8):2257–2270CrossRef
14.
go back to reference Osterhoff G, Ossendorf C, Wanner GA, Simmen HP, Werner CM (2011) Percutaneous iliosacral screw fixation in S1 and S2 for posterior pelvic ring injuries: technique and perioperative complications. Arch Orthop Trauma Surg 131(6):809–813CrossRef Osterhoff G, Ossendorf C, Wanner GA, Simmen HP, Werner CM (2011) Percutaneous iliosacral screw fixation in S1 and S2 for posterior pelvic ring injuries: technique and perioperative complications. Arch Orthop Trauma Surg 131(6):809–813CrossRef
15.
go back to reference Yilmaz E, Abdul-Jabbar A, Tawfik T, Iwanaga J, Schmidt CK, Chapman J, Blecher R, Tubbs RS, Oskouian RJ (2018) S2 alar-iliac screw insertion: technical note with pictorial guide. World Neurosurg 113:e296–e301CrossRef Yilmaz E, Abdul-Jabbar A, Tawfik T, Iwanaga J, Schmidt CK, Chapman J, Blecher R, Tubbs RS, Oskouian RJ (2018) S2 alar-iliac screw insertion: technical note with pictorial guide. World Neurosurg 113:e296–e301CrossRef
16.
go back to reference Shabtai L, Andras LM, Portman M, Harris LR, Skaggs DL (2017) Sacral alar iliac (SAI) screws fail 75% less frequently than iliac screws in neuromuscular scoliosis. J Pediatr Orthop 37:e470–e475CrossRef Shabtai L, Andras LM, Portman M, Harris LR, Skaggs DL (2017) Sacral alar iliac (SAI) screws fail 75% less frequently than iliac screws in neuromuscular scoliosis. J Pediatr Orthop 37:e470–e475CrossRef
17.
go back to reference Hoernschemeyer DG, Pashuck TD, Pfeiffer FM (2017) Analysis of the s2 alar-iliac screw as compared with the traditional iliac screw: does it increase stability with sacroiliac fixation of the spine? Spine J 17(6):875–879CrossRef Hoernschemeyer DG, Pashuck TD, Pfeiffer FM (2017) Analysis of the s2 alar-iliac screw as compared with the traditional iliac screw: does it increase stability with sacroiliac fixation of the spine? Spine J 17(6):875–879CrossRef
18.
go back to reference Hyun SJ, Jung JM, Kim KJ, Jahng TA (2020) Durability and failure types of S2-alar-iliac screws: an analysis of 312 consecutive screws. Oper Neurosurg (Hagerstown) 20(1):91–97CrossRef Hyun SJ, Jung JM, Kim KJ, Jahng TA (2020) Durability and failure types of S2-alar-iliac screws: an analysis of 312 consecutive screws. Oper Neurosurg (Hagerstown) 20(1):91–97CrossRef
19.
go back to reference Ma YH, Wang J, Yin QD, Liu Y, Li D, Wu YW (2021) Effect of iliosacral screw implantation through a new channel in three-dimensional printing pelvic model. Indian J Orthop 56(2):244–248CrossRef Ma YH, Wang J, Yin QD, Liu Y, Li D, Wu YW (2021) Effect of iliosacral screw implantation through a new channel in three-dimensional printing pelvic model. Indian J Orthop 56(2):244–248CrossRef
20.
go back to reference de Sousa Pontes MD, Ismael LK, Francisco LA, Herrero CFPDS (2020) Description of the sacropelvic parameters measurement method for S2-alar iliac screw insertion. Rev Bras Ortop (Sao Paulo) 55(6):702–707 de Sousa Pontes MD, Ismael LK, Francisco LA, Herrero CFPDS (2020) Description of the sacropelvic parameters measurement method for S2-alar iliac screw insertion. Rev Bras Ortop (Sao Paulo) 55(6):702–707
21.
go back to reference Pontes MDS, Francisco LA, Ismael LK, Herrero CFPDS (2021) Reproducibility of S2-alar iliac screw morphometric analysis. Acta Ortop Bras. 29(2):97–100CrossRef Pontes MDS, Francisco LA, Ismael LK, Herrero CFPDS (2021) Reproducibility of S2-alar iliac screw morphometric analysis. Acta Ortop Bras. 29(2):97–100CrossRef
22.
go back to reference Yamada K, Higashi T, Kaneko K, Ide M, Sekiya T, Saito T (2017) Optimal trajectory and insertion accuracy of sacral alar iliac screws. Acta Orthop Traumatol Turc 51(4):313–318CrossRef Yamada K, Higashi T, Kaneko K, Ide M, Sekiya T, Saito T (2017) Optimal trajectory and insertion accuracy of sacral alar iliac screws. Acta Orthop Traumatol Turc 51(4):313–318CrossRef
23.
go back to reference Tavares Junior MCM, de Souza JPV, Araujo TPF, Marcon RM, Cristante AF, de Barros Filho TEP, Letaif OB (2019) Comparative tomographic study of the S2-alar-iliac screw versus the iliac screw. Eur Spine J 28(4):855–862CrossRef Tavares Junior MCM, de Souza JPV, Araujo TPF, Marcon RM, Cristante AF, de Barros Filho TEP, Letaif OB (2019) Comparative tomographic study of the S2-alar-iliac screw versus the iliac screw. Eur Spine J 28(4):855–862CrossRef
24.
go back to reference Lin JD, Tan LA, Wei C, Shillingford JN, Laratta JL, Lombardi JM, Kim YJ, Lehman RA, Lenke LG (2018) The posterior superior iliac spine and sacral laminar slope: key anatomical landmarks for freehand S2-alar-iliac screw placement. J Neurosurg Spine 29(4):429–434CrossRef Lin JD, Tan LA, Wei C, Shillingford JN, Laratta JL, Lombardi JM, Kim YJ, Lehman RA, Lenke LG (2018) The posterior superior iliac spine and sacral laminar slope: key anatomical landmarks for freehand S2-alar-iliac screw placement. J Neurosurg Spine 29(4):429–434CrossRef
25.
go back to reference Kubaszewski Ł, Miękisiak G, Nowakowski A, Pezowicz C, Bajor G, Kiełbowicz Z, Kinda W, Wojtków M, Kaczmarczyk J (2016) Feasibility and accuracy of new insertion technique of S1 transpedicular screw. Computed tomography-based morphometric analysis. Neurol Neurochir Pol 50(5):363–369CrossRef Kubaszewski Ł, Miękisiak G, Nowakowski A, Pezowicz C, Bajor G, Kiełbowicz Z, Kinda W, Wojtków M, Kaczmarczyk J (2016) Feasibility and accuracy of new insertion technique of S1 transpedicular screw. Computed tomography-based morphometric analysis. Neurol Neurochir Pol 50(5):363–369CrossRef
26.
go back to reference Zheng J, Feng X, Xiang J, Liu F, Leung FKL, Chen B (2021) S2-alar-iliac screw and S1 pedicle screw fixation for the treatment of non-osteoporotic sacral fractures: a finite element study. J Orthop Surg Res 16(1):651CrossRef Zheng J, Feng X, Xiang J, Liu F, Leung FKL, Chen B (2021) S2-alar-iliac screw and S1 pedicle screw fixation for the treatment of non-osteoporotic sacral fractures: a finite element study. J Orthop Surg Res 16(1):651CrossRef
27.
go back to reference O’Brien JR, Yu W, Kaufman BE, Bucklen B, Salloum K, Khalil S, Gudipally M (2013) Biomechanical evaluation of S2 alar-iliac screws: effect of length and quad-cortical purchase as compared with iliac fixation. Spine (Phila Pa 1976) 38(20):E1250-1255CrossRef O’Brien JR, Yu W, Kaufman BE, Bucklen B, Salloum K, Khalil S, Gudipally M (2013) Biomechanical evaluation of S2 alar-iliac screws: effect of length and quad-cortical purchase as compared with iliac fixation. Spine (Phila Pa 1976) 38(20):E1250-1255CrossRef
Metadata
Title
Radio-anatomical study of anterior–posterior placement sacroiliac screw channel
Authors
Tianfang Wang
Changbao Wei
Sanjun Gu
Yongwei Wu
Yu Liu
Yunhong Ma
Qudong Yin
Publication date
10-06-2022
Publisher
Springer Berlin Heidelberg
Published in
European Spine Journal / Issue 10/2022
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-022-07257-0

Other articles of this Issue 10/2022

European Spine Journal 10/2022 Go to the issue