Skip to main content
Top
Published in: European Spine Journal 12/2010

01-12-2010 | Original Article

Biomechanical and histological evaluation of an expandable pedicle screw in osteoporotic spine in sheep

Authors: Shiyong Wan, Wei Lei, Zixiang Wu, Da Liu, Mingxuan Gao, Suochao Fu

Published in: European Spine Journal | Issue 12/2010

Login to get access

Abstract

Transpedicular fixation can be challenging in the osteoporotic spine as reduced bone mineral density compromises the mechanical stability of the pedicle screw. Here, we sought to investigate the biomechanical and histological properties of stabilization of expandable pedicle screw (EPS) in the osteoporotic spine in sheep. EPSs and standard pedicle screws, SINO screws, were inserted on the vertebral bodies in four female ovariectomized sheep. Pull-out and cyclic bending resistance test were performed to compare the holding strength of these pedicle screws. High-resolution micro-computed tomography (CT) was performed for three-dimensional image reconstruction. We found that the EPSs provided a 59.6% increase in the pull-out strength over the SINO screws. Moreover, the EPSs withstood a greater number of cycles or load with less displacement before loosening. Micro-CT image reconstruction showed that the tissue mineral density, bone volume fraction, bone surface/bone volume ratio, trabecular thickness, and trabecular separation were significantly better in the expandable portion of the EPSs than those in the anterior portion of the SINO screws (P < 0.05). Furthermore, the trabecular architecture in the screw–bone interface was denser in the expandable portion of the EPS than that in the anterior portion of the SINO screw. Histologically, newly formed bone tissues grew into the center of EPS and were in close contact with the EPS. Our results show that the EPS demonstrates improved biomechanical and histological properties over the standard screw in the osteoporotic spine. The EPS may be of value in treating patients with osteoporosis and warrants further clinical studies.
Literature
1.
go back to reference Bai B, Kummer FJ, Spivak J (2001) Augmentation of anterior vertebral body screw fixation by an injectable, biodegradable calcium phosphate bone substitute. Spine (Phila Pa 1976) 26:2679–2683 Bai B, Kummer FJ, Spivak J (2001) Augmentation of anterior vertebral body screw fixation by an injectable, biodegradable calcium phosphate bone substitute. Spine (Phila Pa 1976) 26:2679–2683
2.
go back to reference Barbier A, Martel C, de Vernejoul MC, Tirode F, Nys M, Mocaer G, Morieux C, Murakami H, Lacheretz F (1999) The visualization and evaluation of bone architecture in the rat using three-dimensional X-ray microcomputed tomography. J Bone Miner Metab 17:37–44CrossRefPubMed Barbier A, Martel C, de Vernejoul MC, Tirode F, Nys M, Mocaer G, Morieux C, Murakami H, Lacheretz F (1999) The visualization and evaluation of bone architecture in the rat using three-dimensional X-ray microcomputed tomography. J Bone Miner Metab 17:37–44CrossRefPubMed
3.
go back to reference Branemark R, Ohrnell LO, Nilsson P, Thomsen P (1997) Biomechanical characterization of osseointegration during healing: an experimental in vivo study in the rat. Biomaterials 18:969–978CrossRefPubMed Branemark R, Ohrnell LO, Nilsson P, Thomsen P (1997) Biomechanical characterization of osseointegration during healing: an experimental in vivo study in the rat. Biomaterials 18:969–978CrossRefPubMed
4.
go back to reference Becker S, Chavanne A, Spitaler R, Kropik K, Aigner N, Ogon M, Redl H (2008) Assessment of different screw augmentation techniques and screw designs in osteoporotic spines. Eur Spine J 17:1462–1469CrossRefPubMed Becker S, Chavanne A, Spitaler R, Kropik K, Aigner N, Ogon M, Redl H (2008) Assessment of different screw augmentation techniques and screw designs in osteoporotic spines. Eur Spine J 17:1462–1469CrossRefPubMed
5.
go back to reference Cook SD, Barbera J, Rubi M, Salkeld SL, Whitecloud TS III (2001) Lumbosacral fixation using expandable pedicle screws: an alternative in reoperation and osteoporosis. Spine J 1:109–114CrossRefPubMed Cook SD, Barbera J, Rubi M, Salkeld SL, Whitecloud TS III (2001) Lumbosacral fixation using expandable pedicle screws: an alternative in reoperation and osteoporosis. Spine J 1:109–114CrossRefPubMed
6.
go back to reference Cook SD, Salkeld SL, Whitecloud TS III, Barbera J (2000) Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design. J Spinal Disord 13:230–236CrossRefPubMed Cook SD, Salkeld SL, Whitecloud TS III, Barbera J (2000) Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design. J Spinal Disord 13:230–236CrossRefPubMed
7.
go back to reference Fransen P (2007) Increasing pedicle screw anchoring in the osteoporotic spine by cement injection through the implant. Technical note and report of three cases. J Neurosurg Spine 7:366–369CrossRefPubMed Fransen P (2007) Increasing pedicle screw anchoring in the osteoporotic spine by cement injection through the implant. Technical note and report of three cases. J Neurosurg Spine 7:366–369CrossRefPubMed
8.
go back to reference Gaines RW Jr (2000) The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82A:1458–1476 Gaines RW Jr (2000) The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82A:1458–1476
9.
go back to reference Hirano T, Hasegawa K, Washio T, Hara T, Takahashi H (1998) Fracture risk during pedicle screw insertion in osteoporotic spine. J Spinal Disord 11:493–497CrossRefPubMed Hirano T, Hasegawa K, Washio T, Hara T, Takahashi H (1998) Fracture risk during pedicle screw insertion in osteoporotic spine. J Spinal Disord 11:493–497CrossRefPubMed
10.
go back to reference Jovanović JD, Jovanović MLJ (2004) Biomechanical model of vertebra based on bone remodeling. Med Biol 11:35–39 Jovanović JD, Jovanović MLJ (2004) Biomechanical model of vertebra based on bone remodeling. Med Biol 11:35–39
11.
go back to reference Kwok AW, Finkelstein JA, Woodside T, Hearn TC, Hu RW (1996) Insertional torque and pull-out strengths of conical and cylindrical pedicle screws in cadaveric bone. Spine 21:2429–2434CrossRefPubMed Kwok AW, Finkelstein JA, Woodside T, Hearn TC, Hu RW (1996) Insertional torque and pull-out strengths of conical and cylindrical pedicle screws in cadaveric bone. Spine 21:2429–2434CrossRefPubMed
12.
go back to reference Laib A, Barou O, Vico L, Lafage-Proust MH, Alexandre C, Rugsegger P (2000) 3D micro-computed tomography of trabecular and cortical bone architecture with application to a rat model of immobilisation osteoporosis. Med Biol Eng Comput 38:326–332CrossRefPubMed Laib A, Barou O, Vico L, Lafage-Proust MH, Alexandre C, Rugsegger P (2000) 3D micro-computed tomography of trabecular and cortical bone architecture with application to a rat model of immobilisation osteoporosis. Med Biol Eng Comput 38:326–332CrossRefPubMed
13.
go back to reference Lei W, Wu ZX (2006) Biomechanical evaluation of an expansive pedicle screw in calf vertebrae. Eur Spine J 15:321–326CrossRefPubMed Lei W, Wu ZX (2006) Biomechanical evaluation of an expansive pedicle screw in calf vertebrae. Eur Spine J 15:321–326CrossRefPubMed
14.
go back to reference Leung KS, Siu WS, Cheung NM, Lui PY, Chow DH, James A, Qin L (2001) Goats as an osteopenic animal model. J Bone Miner Res 16:2348–2355CrossRefPubMed Leung KS, Siu WS, Cheung NM, Lui PY, Chow DH, James A, Qin L (2001) Goats as an osteopenic animal model. J Bone Miner Res 16:2348–2355CrossRefPubMed
15.
go back to reference Lill CA, Fluegel AK, Schneider E (2000) Sheep model for fracture treatment in osteoporotic bone: a pilot study about different induction regimens. J Orthop Trauma 14:559–565CrossRefPubMed Lill CA, Fluegel AK, Schneider E (2000) Sheep model for fracture treatment in osteoporotic bone: a pilot study about different induction regimens. J Orthop Trauma 14:559–565CrossRefPubMed
16.
go back to reference Lill CA, Fluegel AK, Schneider E (2002) Effect of ovariectomy, malnutrition and glucocorticoid application on bone properties in sheep: a pilot study. Osteoporos Int 13:480–486CrossRefPubMed Lill CA, Fluegel AK, Schneider E (2002) Effect of ovariectomy, malnutrition and glucocorticoid application on bone properties in sheep: a pilot study. Osteoporos Int 13:480–486CrossRefPubMed
17.
go back to reference Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81:1519–1528PubMed Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81:1519–1528PubMed
18.
go back to reference Lotz JC, Hu SS, Chiu DF, Yu M, Colliou O, Poser RD (1997) Carbonated apatite cement augmentation of pedicle screw fixation in the lumbar spine. Spine 22:2716–2723CrossRefPubMed Lotz JC, Hu SS, Chiu DF, Yu M, Colliou O, Poser RD (1997) Carbonated apatite cement augmentation of pedicle screw fixation in the lumbar spine. Spine 22:2716–2723CrossRefPubMed
19.
go back to reference MacLeay JM, Olson JD, Enns RM, Les CM, Toth CA, Wheeler DL, Turner AS (2004) Dietary-induced metabolic acidosis decreases bone mineral density in mature ovariectomized ewes. Calcif Tissue Int 75:431–437CrossRefPubMed MacLeay JM, Olson JD, Enns RM, Les CM, Toth CA, Wheeler DL, Turner AS (2004) Dietary-induced metabolic acidosis decreases bone mineral density in mature ovariectomized ewes. Calcif Tissue Int 75:431–437CrossRefPubMed
20.
go back to reference Milcan A, Ayan I, Zeren A, Sinmazcelik T, Yilmaz A, Zeren M, Kuyurtar F (2005) Evaluation of cyanoacrylate augmentation of transpedicular screw pullout strength. J Spinal Disord Tech 18:511–514CrossRefPubMed Milcan A, Ayan I, Zeren A, Sinmazcelik T, Yilmaz A, Zeren M, Kuyurtar F (2005) Evaluation of cyanoacrylate augmentation of transpedicular screw pullout strength. J Spinal Disord Tech 18:511–514CrossRefPubMed
21.
go back to reference Mummaneni PV, Haddock SM, Liebschner MA, Keaveny TM, Rosenberg WS (2002) Biomechanical evaluation of a double-threaded pedicle screw in elderly vertebrae. J Spinal Disord Tech 15:64–68PubMed Mummaneni PV, Haddock SM, Liebschner MA, Keaveny TM, Rosenberg WS (2002) Biomechanical evaluation of a double-threaded pedicle screw in elderly vertebrae. J Spinal Disord Tech 15:64–68PubMed
22.
go back to reference Newman E, Turner AS, Wark JD (1995) The potential of sheep for the study of osteopenia: current status and comparison with other animal models. Bone 16:277S–284SPubMed Newman E, Turner AS, Wark JD (1995) The potential of sheep for the study of osteopenia: current status and comparison with other animal models. Bone 16:277S–284SPubMed
23.
go back to reference Ohlin A, Karlsson M, Düppe H, Hasserius R, Redlund-Johnell I (1994) Complications after transpedicular stabilization of the spine. A survivorship analysis of 163 cases. Spine (Phila Pa 1976) 19:2774–2779 Ohlin A, Karlsson M, Düppe H, Hasserius R, Redlund-Johnell I (1994) Complications after transpedicular stabilization of the spine. A survivorship analysis of 163 cases. Spine (Phila Pa 1976) 19:2774–2779
24.
go back to reference Patel V, Issever AS, Burghardt A, Laib A, Ries M, Majumdar S (2003) Micro CT evaluation of normal and osteoarthritic bone structure in human knee specimens. J Orthop Res 21:6–13CrossRefPubMed Patel V, Issever AS, Burghardt A, Laib A, Ries M, Majumdar S (2003) Micro CT evaluation of normal and osteoarthritic bone structure in human knee specimens. J Orthop Res 21:6–13CrossRefPubMed
25.
go back to reference Pfeifer BA, Krag MH, Johnson C (1994) Repair of failed transpedicle screw fixation. A biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction. Spine (Phila Pa 1976) 19:350–353 Pfeifer BA, Krag MH, Johnson C (1994) Repair of failed transpedicle screw fixation. A biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction. Spine (Phila Pa 1976) 19:350–353
26.
go back to reference Pihlajämaki H, Myllynen P, Böstman O (1997) Complications of transpedicular lumbosacral fixation for non-traumatic disorders. J Bone Joint Surg Br 79:183–189CrossRefPubMed Pihlajämaki H, Myllynen P, Böstman O (1997) Complications of transpedicular lumbosacral fixation for non-traumatic disorders. J Bone Joint Surg Br 79:183–189CrossRefPubMed
27.
go back to reference Reinhold M, Schwieger K, Goldhahn J, Linke B, Knop C, Blauth M (2006) Influence of screw positioning in a new anterior spine fixator on implant loosening in osteoporotic vertebrae. Spine (Phila Pa 1976) 31:406–413 Reinhold M, Schwieger K, Goldhahn J, Linke B, Knop C, Blauth M (2006) Influence of screw positioning in a new anterior spine fixator on implant loosening in osteoporotic vertebrae. Spine (Phila Pa 1976) 31:406–413
28.
go back to reference Renner SM, Lim TH, Kim WJ, Katolik L, An HS, Andersson GB (2004) Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method. Spine (Phila Pa 1976) 29:E212–E216 Renner SM, Lim TH, Kim WJ, Katolik L, An HS, Andersson GB (2004) Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method. Spine (Phila Pa 1976) 29:E212–E216
29.
go back to reference Richter M, Wilke HJ, Kluger P, Neller S, Claes L, Puhl W (2000) Biomechanical evaluation of a new modular rod-screw implant system for posterior instrumentation of the occipito-cervical spine: in vitro comparison with two established implant systems. Eur Spine J 9:417–425CrossRefPubMed Richter M, Wilke HJ, Kluger P, Neller S, Claes L, Puhl W (2000) Biomechanical evaluation of a new modular rod-screw implant system for posterior instrumentation of the occipito-cervical spine: in vitro comparison with two established implant systems. Eur Spine J 9:417–425CrossRefPubMed
30.
go back to reference Rohmiller MT, Schwalm D, Glattes RC, Elalayli TG, Spengler DM (2002) Evaluation of calcium sulfate paste for augmentation of lumbar pedicle screw pullout strength. Spine J 2:255–260CrossRefPubMed Rohmiller MT, Schwalm D, Glattes RC, Elalayli TG, Spengler DM (2002) Evaluation of calcium sulfate paste for augmentation of lumbar pedicle screw pullout strength. Spine J 2:255–260CrossRefPubMed
31.
go back to reference Turner AS, Alvis M, Myers W, Stevens ML, Lundy MW (1995) Changes in bone mineral density and bone-specific alkaline phosphatase in ovariectomized ewes. Bone 17:395S–402SCrossRefPubMed Turner AS, Alvis M, Myers W, Stevens ML, Lundy MW (1995) Changes in bone mineral density and bone-specific alkaline phosphatase in ovariectomized ewes. Bone 17:395S–402SCrossRefPubMed
33.
go back to reference Viljanen JT, Pihlajamäki HK, Törmälä PO, Rokkanen PU (1997) Comparison of the tissue response to absorbable self-reinforced polylactide screws and metallic screws in the fixation of cancellous bone osteotomies: an experimental study on the rabbit distal femur. J Orthop Res 15:398–407CrossRefPubMed Viljanen JT, Pihlajamäki HK, Törmälä PO, Rokkanen PU (1997) Comparison of the tissue response to absorbable self-reinforced polylactide screws and metallic screws in the fixation of cancellous bone osteotomies: an experimental study on the rabbit distal femur. J Orthop Res 15:398–407CrossRefPubMed
34.
go back to reference Wilkes RA, Mackinnon JG, Thomas WG (1994) Neurological deterioration after cement injection into a vertebral body. J Bone Joint Surg Br 76:155PubMed Wilkes RA, Mackinnon JG, Thomas WG (1994) Neurological deterioration after cement injection into a vertebral body. J Bone Joint Surg Br 76:155PubMed
35.
go back to reference Wu ZX, Lei W, Hu YY, Wang HQ, Wan SY, Ma ZS, Sang HX, Fu SC, Han YS (2008) Effect of ovariectomy on BMD, micro-architecture and biomechanics of cortical and cancellous bones in a sheep model. Med Eng Phys 30:1112–1118CrossRefPubMed Wu ZX, Lei W, Hu YY, Wang HQ, Wan SY, Ma ZS, Sang HX, Fu SC, Han YS (2008) Effect of ovariectomy on BMD, micro-architecture and biomechanics of cortical and cancellous bones in a sheep model. Med Eng Phys 30:1112–1118CrossRefPubMed
36.
go back to reference Yamazaki M, Shirota T, Tokugawa Y, Motohashi M, Ohno K, Michi K, Yamaguchi A (1999) Bone reactions to titanium screw implants in ovariectomized animals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 87:411–418CrossRefPubMed Yamazaki M, Shirota T, Tokugawa Y, Motohashi M, Ohno K, Michi K, Yamaguchi A (1999) Bone reactions to titanium screw implants in ovariectomized animals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 87:411–418CrossRefPubMed
37.
go back to reference Zarrinkalam MR, Beard H, Schultz CG, Moore RJ (2009) Validation of the sheep as a large animal model for the study of vertebral osteoporosis. Eur Spine J J18:244–253CrossRef Zarrinkalam MR, Beard H, Schultz CG, Moore RJ (2009) Validation of the sheep as a large animal model for the study of vertebral osteoporosis. Eur Spine J J18:244–253CrossRef
Metadata
Title
Biomechanical and histological evaluation of an expandable pedicle screw in osteoporotic spine in sheep
Authors
Shiyong Wan
Wei Lei
Zixiang Wu
Da Liu
Mingxuan Gao
Suochao Fu
Publication date
01-12-2010
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 12/2010
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-010-1489-4

Other articles of this Issue 12/2010

European Spine Journal 12/2010 Go to the issue