Skip to main content
Top
Published in: Journal of Anesthesia 3/2014

01-06-2014 | Short Communication

Evaluation of multiwave pulse total-hemoglobinometer during general anesthesia

Authors: Daisuke Toyoda, Rie Yasumura, Mitsue Fukuda, Ryoichi Ochiai, Yoshifumi Kotake

Published in: Journal of Anesthesia | Issue 3/2014

Login to get access

Abstract

The purpose of this prospective study was to evaluate the accuracy and trending ability of a four-wavelength pulse-total hemoglobinometer that continuously and noninvasively measures hemoglobin in surgical patients. With IRB approval and informed consent, spectrophotometric hemoglobin (SpHb) was measured with a pulse-total hemoglobinometer manufactured by Nihon Kohden Corp (Tokyo, Japan) and compared to the CO-oximeter equipped with blood gas analyzer. Two hundred twenty-five samples from 56 subjects underwent analysis. Bland–Altman analysis revealed that the bias ± precision of the current technology was 0.0 ± 1.4 g/dl and −0.2 ± 1.3 g/dl for total samples and samples with 8 < Hb < 11 g/dl, respectively. The percentages of samples with intermediate risk of therapeutic error in error grid analysis and the concordance rate of 4-quadrant trending assay was 17 % and 77 %, respectively. The Cohen kappa statistic for Hb < 10 g/dl was 0.38, suggesting that the agreement between SpHb and CO-oximeter-derived Hb was fair. Collectively, wide limits of agreement, especially at the critical level of hemoglobin, and less than moderate agreement against CO-oximeter-derived hemoglobin preclude the use of the pulse-total hemoglobinometer as a decision-making tool for transfusion.
Literature
1.
go back to reference Aoyagi T, Fuse M, Kobayashi N, Machida K, Miyasaka K. Multiwavelength pulse oximetry: theory for the future. Anesth Analg. 2007;105:S53–8.PubMedCrossRef Aoyagi T, Fuse M, Kobayashi N, Machida K, Miyasaka K. Multiwavelength pulse oximetry: theory for the future. Anesth Analg. 2007;105:S53–8.PubMedCrossRef
2.
go back to reference Shamir MY, Avramovich A, Smaka T. The current status of continuous noninvasive measurement of total, carboxy, and methemoglobin concentration. Anesth Analg. 2012;114:972–8.PubMedCrossRef Shamir MY, Avramovich A, Smaka T. The current status of continuous noninvasive measurement of total, carboxy, and methemoglobin concentration. Anesth Analg. 2012;114:972–8.PubMedCrossRef
3.
go back to reference Noiri E, Kobayashi N, Takamura Y, Iijima T, Takagi T, Doi K, Nakao A, Yamamoto T, Takeda S, Fujita T. Pulse total-hemoglobinometer provides accurate noninvasive monitoring. Crit Care Med. 2005;33:2831–5.PubMedCrossRef Noiri E, Kobayashi N, Takamura Y, Iijima T, Takagi T, Doi K, Nakao A, Yamamoto T, Takeda S, Fujita T. Pulse total-hemoglobinometer provides accurate noninvasive monitoring. Crit Care Med. 2005;33:2831–5.PubMedCrossRef
4.
go back to reference Scharnhorst V, Van De Laar PJ, Vader HL. Hemoglobin in samples with leukocytosis can be measured on ABL 700 series blood gas analyzers. Clin Chem. 2003;49:2107–8.PubMedCrossRef Scharnhorst V, Van De Laar PJ, Vader HL. Hemoglobin in samples with leukocytosis can be measured on ABL 700 series blood gas analyzers. Clin Chem. 2003;49:2107–8.PubMedCrossRef
5.
go back to reference Morey TE, Gravenstein N, Rice MJ. Let’s think clinically instead of mathematically about device accuracy. Anesth Analg. 2011;113:89–91.PubMedCrossRef Morey TE, Gravenstein N, Rice MJ. Let’s think clinically instead of mathematically about device accuracy. Anesth Analg. 2011;113:89–91.PubMedCrossRef
6.
go back to reference Park YH, Lee JH, Song HG, Byon HJ, Kim HS, Kim JT. The accuracy of noninvasive hemoglobin monitoring using the radical-7 pulse CO-oximeter in children undergoing neurosurgery. Anesth Analg. 2012;115:1302–7.PubMedCrossRef Park YH, Lee JH, Song HG, Byon HJ, Kim HS, Kim JT. The accuracy of noninvasive hemoglobin monitoring using the radical-7 pulse CO-oximeter in children undergoing neurosurgery. Anesth Analg. 2012;115:1302–7.PubMedCrossRef
7.
go back to reference Barker SJ, Badal JJ. The measurement of dyshemoglobins and total hemoglobin by pulse oximetry. Curr Opin Anaesthesiol. 2008;21:805–10.PubMedCrossRef Barker SJ, Badal JJ. The measurement of dyshemoglobins and total hemoglobin by pulse oximetry. Curr Opin Anaesthesiol. 2008;21:805–10.PubMedCrossRef
8.
go back to reference Macknet MR, Allard M, Applegate RL 2nd, Rook J. The accuracy of noninvasive and continuous total hemoglobin measurement by pulse CO-oximetry in human subjects undergoing hemodilution. Anesth Analg. 2010;111:1424–6.PubMedCrossRef Macknet MR, Allard M, Applegate RL 2nd, Rook J. The accuracy of noninvasive and continuous total hemoglobin measurement by pulse CO-oximetry in human subjects undergoing hemodilution. Anesth Analg. 2010;111:1424–6.PubMedCrossRef
9.
go back to reference Nguyen BV, Vincent JL, Nowak E, Coat M, Paleiron N, Gouny P, Ould-Ahmed M, Guillouet M, Arvieux CC, Gueret G. The accuracy of noninvasive hemoglobin measurement by multiwavelength pulse oximetry after cardiac surgery. Anesth Analg. 2011;113:1052–7.PubMedCrossRef Nguyen BV, Vincent JL, Nowak E, Coat M, Paleiron N, Gouny P, Ould-Ahmed M, Guillouet M, Arvieux CC, Gueret G. The accuracy of noninvasive hemoglobin measurement by multiwavelength pulse oximetry after cardiac surgery. Anesth Analg. 2011;113:1052–7.PubMedCrossRef
10.
go back to reference Miller RD, Ward TA, Shiboski SC, Cohen NH. A comparison of three methods of hemoglobin monitoring in patients undergoing spine surgery. Anesth Analg. 2011;112:858–63.PubMedCrossRef Miller RD, Ward TA, Shiboski SC, Cohen NH. A comparison of three methods of hemoglobin monitoring in patients undergoing spine surgery. Anesth Analg. 2011;112:858–63.PubMedCrossRef
11.
go back to reference Butwick A, Hilton G, Carvalho B. Non-invasive haemoglobin measurement in patients undergoing elective Caesarean section. Br J Anaesth. 2012;108:271–7.PubMedCrossRef Butwick A, Hilton G, Carvalho B. Non-invasive haemoglobin measurement in patients undergoing elective Caesarean section. Br J Anaesth. 2012;108:271–7.PubMedCrossRef
12.
go back to reference Vos JJ, Kalmar AF, Struys MM, Porte RJ, Wietasch JK, Scheeren TW, Hendriks HG. Accuracy of non-invasive measurement of haemoglobin concentration by pulse co-oximetry during steady-state and dynamic conditions in liver surgery. Br J Anaesth. 2012;109:522–8.PubMedCrossRef Vos JJ, Kalmar AF, Struys MM, Porte RJ, Wietasch JK, Scheeren TW, Hendriks HG. Accuracy of non-invasive measurement of haemoglobin concentration by pulse co-oximetry during steady-state and dynamic conditions in liver surgery. Br J Anaesth. 2012;109:522–8.PubMedCrossRef
13.
go back to reference Miller RD, Ward TA, McCulloch CE, Cohen NH. Does a digital regional nerve block improve the accuracy of noninvasive hemoglobin monitoring? J Anesth. 2012;26:845–50.PubMedCrossRef Miller RD, Ward TA, McCulloch CE, Cohen NH. Does a digital regional nerve block improve the accuracy of noninvasive hemoglobin monitoring? J Anesth. 2012;26:845–50.PubMedCrossRef
14.
go back to reference Isosu T, Obara S, Hosono A, Ohashi S, Nakano Y, Imaizumi T, Mogami M, Murakawa M. Validation of continuous and noninvasive hemoglobin monitoring by pulse CO-oximetry in Japanese surgical patients. J Clin Monit Comput. 2013;27:55–60.PubMedCrossRef Isosu T, Obara S, Hosono A, Ohashi S, Nakano Y, Imaizumi T, Mogami M, Murakawa M. Validation of continuous and noninvasive hemoglobin monitoring by pulse CO-oximetry in Japanese surgical patients. J Clin Monit Comput. 2013;27:55–60.PubMedCrossRef
15.
go back to reference Hebert PC, Wells G, Blajchman MA, Marshall J, Martin C, Pagliarello G, Tweeddale M, Schweitzer I, Yetisir E. A multicenter, randomized, controlled clinical trial of transfusion requirements in critical care. Transfusion requirements in critical care investigators, Canadian Critical Care Trials Group. N Engl J Med. 1999;340:409–17.PubMedCrossRef Hebert PC, Wells G, Blajchman MA, Marshall J, Martin C, Pagliarello G, Tweeddale M, Schweitzer I, Yetisir E. A multicenter, randomized, controlled clinical trial of transfusion requirements in critical care. Transfusion requirements in critical care investigators, Canadian Critical Care Trials Group. N Engl J Med. 1999;340:409–17.PubMedCrossRef
16.
go back to reference Hebert PC, Yetisir E, Martin C, Blajchman MA, Wells G, Marshall J, Tweeddale M, Pagliarello G, Schweitzer I. Is a low transfusion threshold safe in critically ill patients with cardiovascular diseases? Crit Care Med. 2001;29:227–34.PubMedCrossRef Hebert PC, Yetisir E, Martin C, Blajchman MA, Wells G, Marshall J, Tweeddale M, Pagliarello G, Schweitzer I. Is a low transfusion threshold safe in critically ill patients with cardiovascular diseases? Crit Care Med. 2001;29:227–34.PubMedCrossRef
17.
go back to reference Carson JL, Terrin ML, Noveck H, Sanders DW, Chaitman BR, Rhoads GG, Nemo G, Dragert K, Beaupre L, Hildebrand K, Macaulay W, Lewis C, Cook DR, Dobbin G, Zakriya KJ, Apple FS, Horney RA, Magaziner J. Liberal or restrictive transfusion in high-risk patients after hip surgery. N Engl J Med. 2011;365:2453–62.PubMedCentralPubMedCrossRef Carson JL, Terrin ML, Noveck H, Sanders DW, Chaitman BR, Rhoads GG, Nemo G, Dragert K, Beaupre L, Hildebrand K, Macaulay W, Lewis C, Cook DR, Dobbin G, Zakriya KJ, Apple FS, Horney RA, Magaziner J. Liberal or restrictive transfusion in high-risk patients after hip surgery. N Engl J Med. 2011;365:2453–62.PubMedCentralPubMedCrossRef
18.
go back to reference Wu P, Morey TE, Harris NS, Gravenstein N, Rice MJ. Intravenous fluids cause systemic bias in a conductivity-based point-of-care hematocrit meter. Anesth Analg. 2012;114:314–21.PubMedCrossRef Wu P, Morey TE, Harris NS, Gravenstein N, Rice MJ. Intravenous fluids cause systemic bias in a conductivity-based point-of-care hematocrit meter. Anesth Analg. 2012;114:314–21.PubMedCrossRef
19.
go back to reference Prakash S, Reddan D, Heidenheim AP, Kianfar C, Lindsay RM. Central, peripheral, and other blood volume changes during hemodialysis. ASAIO J. 2002;48:379–82.PubMedCrossRef Prakash S, Reddan D, Heidenheim AP, Kianfar C, Lindsay RM. Central, peripheral, and other blood volume changes during hemodialysis. ASAIO J. 2002;48:379–82.PubMedCrossRef
20.
go back to reference Slight RD, Bappu NJ, Nzewi OC, McClelland DB, Mankad PS. Perioperative red cell, plasma, and blood volume change in patients undergoing cardiac surgery. Transfusion. 2006;46:392–7.PubMedCrossRef Slight RD, Bappu NJ, Nzewi OC, McClelland DB, Mankad PS. Perioperative red cell, plasma, and blood volume change in patients undergoing cardiac surgery. Transfusion. 2006;46:392–7.PubMedCrossRef
21.
go back to reference Feiner JR, Bickler PE, Mannheimer PD. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia. Anesth Analg. 2010;111:143–8.PubMed Feiner JR, Bickler PE, Mannheimer PD. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia. Anesth Analg. 2010;111:143–8.PubMed
Metadata
Title
Evaluation of multiwave pulse total-hemoglobinometer during general anesthesia
Authors
Daisuke Toyoda
Rie Yasumura
Mitsue Fukuda
Ryoichi Ochiai
Yoshifumi Kotake
Publication date
01-06-2014
Publisher
Springer Japan
Published in
Journal of Anesthesia / Issue 3/2014
Print ISSN: 0913-8668
Electronic ISSN: 1438-8359
DOI
https://doi.org/10.1007/s00540-013-1730-5

Other articles of this Issue 3/2014

Journal of Anesthesia 3/2014 Go to the issue