Excerpt

I congratulate Bittner and colleagues for presenting this most valuable document on reviewed guidelines for laparoscopic (TAPP) and endoscopic (TEP) treatment of inguinal hernia [1]. However, two closely related topics on the handling of a large direct sac and the risk of seroma formation need further explanation. I believe that part of their statements and recommendations lacks precision and therefore could be misleading. …
Literature
1.
go back to reference Bittner R, Arregui ME, Bisgaard T, Dubai M, Ferzli GS, Fitzgibbons RJ, Fortelny RH, Klinge U, Kockerling F, Kuhry E, Kukleta J, Lomanto D, Misra MC, Montgomery A, Morales-Conde S, Reinpold W, Rosenberg J, Sauerland S, Schug-Pass C, Singh K, Timoney M, Weyhe D, Chowbey P (2011) Guidelines for laparoscopic (TAPP) and endoscopic (TEP) treatment of inguinal hernia. International endohernia society (IEHS). Surg Endosc 25:2773–2843PubMedCrossRef Bittner R, Arregui ME, Bisgaard T, Dubai M, Ferzli GS, Fitzgibbons RJ, Fortelny RH, Klinge U, Kockerling F, Kuhry E, Kukleta J, Lomanto D, Misra MC, Montgomery A, Morales-Conde S, Reinpold W, Rosenberg J, Sauerland S, Schug-Pass C, Singh K, Timoney M, Weyhe D, Chowbey P (2011) Guidelines for laparoscopic (TAPP) and endoscopic (TEP) treatment of inguinal hernia. International endohernia society (IEHS). Surg Endosc 25:2773–2843PubMedCrossRef
2.
go back to reference Moore M, Burak WE Jr, Nelson E, Kearney T, Simmons R, Mayers L, Spotnitz WD (2001) Fibrin sealant reduces the duration and amount of fluid drainage after axillary dissection: a randomized prospective clinical trial. J Am Coll Surg 192:591–599PubMedCrossRef Moore M, Burak WE Jr, Nelson E, Kearney T, Simmons R, Mayers L, Spotnitz WD (2001) Fibrin sealant reduces the duration and amount of fluid drainage after axillary dissection: a randomized prospective clinical trial. J Am Coll Surg 192:591–599PubMedCrossRef
3.
go back to reference Katkhouda N, Mavor E, Friedlander MH, Mason RJ, Kiyabu M, Grant SW, Achanta K, Kirkman EL, Narayanan K, Essani R (2001) Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair. Ann Surg 233:18–25PubMedCrossRef Katkhouda N, Mavor E, Friedlander MH, Mason RJ, Kiyabu M, Grant SW, Achanta K, Kirkman EL, Narayanan K, Essani R (2001) Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair. Ann Surg 233:18–25PubMedCrossRef
4.
go back to reference Shinde PT (2009) Fibrin sealant versus use of tackers for fixation of mesh in laparoscopic inguinal hernia repair. World J Laparosc Surg 2:42–48CrossRef Shinde PT (2009) Fibrin sealant versus use of tackers for fixation of mesh in laparoscopic inguinal hernia repair. World J Laparosc Surg 2:42–48CrossRef
5.
go back to reference Lowham AS, Filipi CJ, Fitzgibbons RJ Jr, Stoppa R, Wantz GE, Felix EL, Crafton WB (1997) Mechanisms of hernia recurrence after preperitoneal mesh repair: traditional and laparoscopic. Ann Surg 225:422–431PubMedCrossRef Lowham AS, Filipi CJ, Fitzgibbons RJ Jr, Stoppa R, Wantz GE, Felix EL, Crafton WB (1997) Mechanisms of hernia recurrence after preperitoneal mesh repair: traditional and laparoscopic. Ann Surg 225:422–431PubMedCrossRef
6.
go back to reference Khaleal F, Berney CR (2011) The role of fibrin glue in decreasing chronic pain in laparoscopic totally extraperitoneal (TEP) inguinal hernia repair: a single surgeon’s experience. ANZ J Surg 81:154–158PubMedCrossRef Khaleal F, Berney CR (2011) The role of fibrin glue in decreasing chronic pain in laparoscopic totally extraperitoneal (TEP) inguinal hernia repair: a single surgeon’s experience. ANZ J Surg 81:154–158PubMedCrossRef
7.
go back to reference Lau H (2005) Fibrin sealant versus mechanical stapling for mesh fixation during endoscopic extraperitoneal inguinal hernioplasty: a randomized prospective trial. Ann Surg 242:670–675PubMedCrossRef Lau H (2005) Fibrin sealant versus mechanical stapling for mesh fixation during endoscopic extraperitoneal inguinal hernioplasty: a randomized prospective trial. Ann Surg 242:670–675PubMedCrossRef
9.
go back to reference Berney CR (2011) The Endoloop technique for the primary closure of direct inguinal hernia defect during the endoscopic totally extraperitoneal approach. Hernia [Epub ahead of print] Berney CR (2011) The Endoloop technique for the primary closure of direct inguinal hernia defect during the endoscopic totally extraperitoneal approach. Hernia [Epub ahead of print]
Metadata
Title
Guidelines for laparoscopic (TAPP) and endoscopic (TEP) treatment of inguinal hernia
Author
Christophe R. Berney
Publication date
01-11-2012
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 11/2012
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-012-2293-5

Other articles of this Issue 11/2012

Surgical Endoscopy 11/2012 Go to the issue