Objective

To compare the efficacy and safety of the Baerveldt® glaucoma implant (BGI) between a preserved donor scleral patch alone and double scleral flaps, comprising a preserved donor scleral patch and an autologous scleral pedicle flap.

Methods

This was an open-label retrospective study. We analyzed the cases of 52 consecutive patients (56 eyes) who underwent BGI surgery with the Hoffman elbow (#BG 102–350, Abbott) and were followed up for >1 year. Twenty-one eyes underwent BGI surgery with a preserved donor scleral patch alone (donor-patch group), and the other 35 eyes underwent BGI surgery with a preserved donor scleral patch and an autologous scleral pedicle flap (double-flap group). The main outcome was the incidence of Hoffman elbow exposure associated with each surgical approach.

Results

Three patients in the donor-patch group (14.3%) developed Hoffman elbow exposure, whereas in the double-flap group, no cases had Hoffman elbow exposure (p = 0.048).

Conclusions

The use of the double scleral flaps technique was more efficient in preventing Hoffman elbow exposure.
Literature
2.
go back to reference Nguyen QH (2004) Avoiding and managing complications of glaucoma drainage implants. Curr Opin Ophthalmol 15:147–150CrossRefPubMed Nguyen QH (2004) Avoiding and managing complications of glaucoma drainage implants. Curr Opin Ophthalmol 15:147–150CrossRefPubMed
4.
go back to reference Smith MF, Doyle JW, Sherwood MB (1995) Comparison of the Baerveldt glaucoma implant with the double-plate Molteno drainage implant. Arch Ophthalmol 113:444–447CrossRefPubMed Smith MF, Doyle JW, Sherwood MB (1995) Comparison of the Baerveldt glaucoma implant with the double-plate Molteno drainage implant. Arch Ophthalmol 113:444–447CrossRefPubMed
5.
go back to reference Ranganath A, Hashim A (2011) Late-onset endophthalmitis secondary to exposed glaucoma tube implant in a rare case of paediatric glaucoma. Case Rep Ophthalmol Med 183647. doi:10.1155/2011/183647 Ranganath A, Hashim A (2011) Late-onset endophthalmitis secondary to exposed glaucoma tube implant in a rare case of paediatric glaucoma. Case Rep Ophthalmol Med 183647. doi:10.​1155/​2011/​183647
6.
go back to reference Zeppa L, Romano MR, Capasso L, Tortori A, Majorana MA, Costagliola C (2010) Sutureless human sclera donor patch graft for Ahmed glaucoma valve. Eur J Ophthalmol 20:546–551PubMed Zeppa L, Romano MR, Capasso L, Tortori A, Majorana MA, Costagliola C (2010) Sutureless human sclera donor patch graft for Ahmed glaucoma valve. Eur J Ophthalmol 20:546–551PubMed
8.
go back to reference Lankaranian D, Reis R, Henderer JD, Choe S, Moster MR (2008) Comparison of single thickness and double thickness processed pericardium patch graft in glaucoma drainage device surgery: a single surgeon comparison of outcome. J Glaucoma 17:48–51. doi:10.1097/IJG.0b013e318133fc49 CrossRefPubMed Lankaranian D, Reis R, Henderer JD, Choe S, Moster MR (2008) Comparison of single thickness and double thickness processed pericardium patch graft in glaucoma drainage device surgery: a single surgeon comparison of outcome. J Glaucoma 17:48–51. doi:10.​1097/​IJG.​0b013e318133fc49​ CrossRefPubMed
9.
go back to reference Smith MF, Doyle JW, Ticrney JW Jr (2002) A comparison of glaucoma drainage implant tube coverage. J Glaucoma 11:143–147CrossRefPubMed Smith MF, Doyle JW, Ticrney JW Jr (2002) A comparison of glaucoma drainage implant tube coverage. J Glaucoma 11:143–147CrossRefPubMed
10.
go back to reference Brandt JD (1993) Patch grafts of dehydrated cadaveric dura mater for tube-shunt glaucoma surgery. Arch Ophthalmol 111:1436–1439CrossRefPubMed Brandt JD (1993) Patch grafts of dehydrated cadaveric dura mater for tube-shunt glaucoma surgery. Arch Ophthalmol 111:1436–1439CrossRefPubMed
14.
go back to reference Gutierrez-Diaz E, Montero-Rodriguez M, Mencia-Gutierrez E, Cabello A, Monescillo J (2005) Long-term persistence of fascia lata patch graft in glaucoma drainage device surgery. Eur J Ophthalmol 15:412–414 Gutierrez-Diaz E, Montero-Rodriguez M, Mencia-Gutierrez E, Cabello A, Monescillo J (2005) Long-term persistence of fascia lata patch graft in glaucoma drainage device surgery. Eur J Ophthalmol 15:412–414
17.
19.
go back to reference Stewart WC, Kristoffersen CJ, Demos CM, Fsadni MG, Stewart JA (2010) Incidence of conjunctival exposure following drainage device implantation in patients with glaucoma. Eur J Ophthalmol 20:124–130PubMed Stewart WC, Kristoffersen CJ, Demos CM, Fsadni MG, Stewart JA (2010) Incidence of conjunctival exposure following drainage device implantation in patients with glaucoma. Eur J Ophthalmol 20:124–130PubMed
20.
go back to reference Budenz DL, Feuer WJ, Barton K, Schiffman J, Costa VP, Godfrey DG, Buys YM, Ahmed Baerveldt Comparison Study G (2016) Postoperative complications in the Ahmed Baerveldt comparison study during five years of follow-up. Am J Ophthalmol 163:75–82 e73. doi:10.1016/j.ajo.2015.11.023 CrossRefPubMed Budenz DL, Feuer WJ, Barton K, Schiffman J, Costa VP, Godfrey DG, Buys YM, Ahmed Baerveldt Comparison Study G (2016) Postoperative complications in the Ahmed Baerveldt comparison study during five years of follow-up. Am J Ophthalmol 163:75–82 e73. doi:10.​1016/​j.​ajo.​2015.​11.​023 CrossRefPubMed
21.
Metadata
Title
Baerveldt® glaucoma implant surgery with the double scleral flap technique to prevent Hoffman elbow exposure
Authors
Naoki Tojo
Tomoko Ueda-Consolvo
Shuichiro Yanagisawa
Atsushi Hayashi
Publication date
01-10-2017
Publisher
Springer Berlin Heidelberg
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 10/2017
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-017-3726-6

Other articles of this Issue 10/2017

Graefe's Archive for Clinical and Experimental Ophthalmology 10/2017 Go to the issue