Skip to main content
Top
Published in: BMC Ophthalmology 1/2016

Open Access 01-12-2016 | Research article

Partial thickness corneal tissue as a patch graft material for prevention of glaucoma drainage device exposure

Authors: Oriel Spierer, Michael Waisbourd, Yitzhak Golan, Hadas Newman, Rony Rachmiel

Published in: BMC Ophthalmology | Issue 1/2016

Login to get access

Abstract

Background

To protect from erosion of the tube in glaucoma drainage device (GDD), the tube is covered by a biologic tissue which is roofed by the conjunctiva. Sclera, pericardium, dura mater and cornea are available as a patch graft. Drawbacks of some of these materials may include high cost and poor appearance. The purpose of this study is to report the long-term outcomes of partial thickness corneal grafts to cover the tube and prevent its exposure, in GDD surgeries.

Methods

This was a retrospective review of all patients who underwent Ahmed glaucoma valve implantation and had a minimum follow-up of 12 months. The tube was covered by a 300-micron partial thickness corneal graft taken either from a previous Descemet stripping endothelial keratoplasty procedure or cut from a whole corneal graft button unsuitable for keratoplasty.

Results

Forty-four patients (45 eyes, mean follow-up of 27.6 ± 11.4 months) were enrolled. The partial thickness corneal grafts maintained clarity throughout follow-up with satisfactory cosmetic results. Mild conjunctival retraction occurred in 4 eyes (8.9 %) between 1 and 12 months after the surgery. Corneal graft melting occurred in 3 (6.7 %) eyes. Tube exposure and additional surgery to re-patch or suture the conjunctiva over the tube was needed in 1 (2.2 %) eye. None of the patients had graft infection or immunologic rejection.

Conclusions

Partial thickness corneal grafts have favorable long-term outcome as a patch for GDD tubes with low rates of tube exposure and other complications.
Literature
1.
go back to reference Minckler DS, Francis BA, Hodapp EA, Jampel HD, Lin SC, Samples JR, et al. Aqueous shunts in glaucoma: a report by the American Academy of Ophthalmology. Ophthalmology. 2008;115:1089–98.CrossRefPubMed Minckler DS, Francis BA, Hodapp EA, Jampel HD, Lin SC, Samples JR, et al. Aqueous shunts in glaucoma: a report by the American Academy of Ophthalmology. Ophthalmology. 2008;115:1089–98.CrossRefPubMed
3.
go back to reference Gedde SJ, Scott IU, Tabandeh H, Luu KK, Budenz DL, Greenfield DS, et al. Late endophthalmitis associated with glaucoma drainage implants. Ophthalmology. 2001;108:1323–7.CrossRefPubMed Gedde SJ, Scott IU, Tabandeh H, Luu KK, Budenz DL, Greenfield DS, et al. Late endophthalmitis associated with glaucoma drainage implants. Ophthalmology. 2001;108:1323–7.CrossRefPubMed
4.
go back to reference Singh M, Chew PT, Tan D. Corneal patch graft repair of exposed glaucoma drainage implants. Cornea. 2008;27:1171–3.CrossRefPubMed Singh M, Chew PT, Tan D. Corneal patch graft repair of exposed glaucoma drainage implants. Cornea. 2008;27:1171–3.CrossRefPubMed
5.
go back to reference Smith MF, Doyle JW, Ticrney Jr JW. A comparison of glaucoma drainage implant tube coverage. J Glaucoma. 2002;11:143–7.CrossRefPubMed Smith MF, Doyle JW, Ticrney Jr JW. A comparison of glaucoma drainage implant tube coverage. J Glaucoma. 2002;11:143–7.CrossRefPubMed
6.
go back to reference Lankaranian D, Reis R, Henderer JD, Choe S, Moster MR. Comparison of single thickness and double thickness processed pericardium patch graft in glaucoma drainage device surgery: a single surgeon comparison of outcome. J Glaucoma. 2008;17:48–51.CrossRefPubMed Lankaranian D, Reis R, Henderer JD, Choe S, Moster MR. Comparison of single thickness and double thickness processed pericardium patch graft in glaucoma drainage device surgery: a single surgeon comparison of outcome. J Glaucoma. 2008;17:48–51.CrossRefPubMed
7.
go back to reference Tamcelik N, Ozkok A, Sarıcı AM, Atalay E, Yetik H, Gungor K. Tenon advancement and duplication technique to prevent postoperative Ahmed valve tube exposure in patients with refractory glaucoma. Jpn J Ophthalmol. 2013;57:359–64.CrossRefPubMed Tamcelik N, Ozkok A, Sarıcı AM, Atalay E, Yetik H, Gungor K. Tenon advancement and duplication technique to prevent postoperative Ahmed valve tube exposure in patients with refractory glaucoma. Jpn J Ophthalmol. 2013;57:359–64.CrossRefPubMed
8.
go back to reference Kugu S, Erdogan G, Sevim MS, Ozerturk Y. Efficacy of long scleral tunnel technique in preventing Ahmed glaucoma valve tube exposure through conjunctiva. Semin Ophthalmol. 2015;30:1–5.CrossRefPubMed Kugu S, Erdogan G, Sevim MS, Ozerturk Y. Efficacy of long scleral tunnel technique in preventing Ahmed glaucoma valve tube exposure through conjunctiva. Semin Ophthalmol. 2015;30:1–5.CrossRefPubMed
9.
go back to reference Gedde SJ, Parrish RK, Budenz DL, Heuer DK. Update on aqueous shunts. Exp Eye Res. 2011;93:284–90.CrossRefPubMed Gedde SJ, Parrish RK, Budenz DL, Heuer DK. Update on aqueous shunts. Exp Eye Res. 2011;93:284–90.CrossRefPubMed
10.
go back to reference Geffen N, Buys YM, Smith M, Anraku A, Alasbali T, Rachmiel R, et al. Conjunctival complications related to Ahmed glaucoma valve insertion. J Glaucoma. 2014;23:109–14.CrossRefPubMed Geffen N, Buys YM, Smith M, Anraku A, Alasbali T, Rachmiel R, et al. Conjunctival complications related to Ahmed glaucoma valve insertion. J Glaucoma. 2014;23:109–14.CrossRefPubMed
11.
go back to reference Huang MC, Netland PA, Coleman AL, Siegner SW, Moster MR, Hill RA. Intermediate-term clinical experience with the Ahmed Glaucoma Valve implant. Am J Ophthalmol. 1999;127:27–33.CrossRefPubMed Huang MC, Netland PA, Coleman AL, Siegner SW, Moster MR, Hill RA. Intermediate-term clinical experience with the Ahmed Glaucoma Valve implant. Am J Ophthalmol. 1999;127:27–33.CrossRefPubMed
12.
go back to reference Wilson MR, Mendis U, Paliwal A, Haynatzka V. Long-term follow-up of primary glaucoma surgery with Ahmed glaucoma valve implant versus trabeculectomy. Am J Ophthalmol. 2003;136:464–70.CrossRefPubMed Wilson MR, Mendis U, Paliwal A, Haynatzka V. Long-term follow-up of primary glaucoma surgery with Ahmed glaucoma valve implant versus trabeculectomy. Am J Ophthalmol. 2003;136:464–70.CrossRefPubMed
13.
go back to reference Smith M, Buys YM, Trope GE. Replacement of Ahmed aqueous drainage devices in eyes with device-related complications. J Glaucoma. 2009;18:484–7.CrossRefPubMed Smith M, Buys YM, Trope GE. Replacement of Ahmed aqueous drainage devices in eyes with device-related complications. J Glaucoma. 2009;18:484–7.CrossRefPubMed
14.
go back to reference Ainsworth G, Rotchford A, Dua HS, King AJ. A novel use of amniotic membrane in the management of tube exposure following glaucoma tube shunt surgery. Br J Ophthalmol. 2006;90:417–9.PubMedCentralCrossRefPubMed Ainsworth G, Rotchford A, Dua HS, King AJ. A novel use of amniotic membrane in the management of tube exposure following glaucoma tube shunt surgery. Br J Ophthalmol. 2006;90:417–9.PubMedCentralCrossRefPubMed
15.
go back to reference Rootman DB, Trope GE, Rootman DS. Glaucoma aqueous drainage device erosion repair with buccal mucous membrane grafts. J Glaucoma. 2009;18:618–22.CrossRefPubMed Rootman DB, Trope GE, Rootman DS. Glaucoma aqueous drainage device erosion repair with buccal mucous membrane grafts. J Glaucoma. 2009;18:618–22.CrossRefPubMed
16.
go back to reference Huddleston SM, Feldman RM, Budenz DL, Bell NP, Lee DA, Chuang AZ, et al. Aqueous shunt exposure: a retrospective review of repair outcome. J Glaucoma. 2013;22:433–8.CrossRefPubMed Huddleston SM, Feldman RM, Budenz DL, Bell NP, Lee DA, Chuang AZ, et al. Aqueous shunt exposure: a retrospective review of repair outcome. J Glaucoma. 2013;22:433–8.CrossRefPubMed
17.
go back to reference Koval MS, El Sayyad FF, Bell NP, Chuang AZ, Lee DA, Hypes SM, et al. Risk factors for tube shunt exposure: a matched case–control study. J Ophthalmol. 2013;2013:196215.PubMedCentralCrossRefPubMed Koval MS, El Sayyad FF, Bell NP, Chuang AZ, Lee DA, Hypes SM, et al. Risk factors for tube shunt exposure: a matched case–control study. J Ophthalmol. 2013;2013:196215.PubMedCentralCrossRefPubMed
18.
go back to reference Byun YS, Lee NY, Park CK. Risk factors of implant exposure outside the conjunctiva after Ahmed glaucoma valve implantation. Jpn J Ophthalmol. 2009;53:114–9.CrossRefPubMed Byun YS, Lee NY, Park CK. Risk factors of implant exposure outside the conjunctiva after Ahmed glaucoma valve implantation. Jpn J Ophthalmol. 2009;53:114–9.CrossRefPubMed
19.
go back to reference Pakravan M, Yazdani S, Shahabi C, Yaseri M. Superior versus inferior Ahmed glaucoma valve implantation. Ophthalmology. 2009;116:208–13.CrossRefPubMed Pakravan M, Yazdani S, Shahabi C, Yaseri M. Superior versus inferior Ahmed glaucoma valve implantation. Ophthalmology. 2009;116:208–13.CrossRefPubMed
20.
go back to reference Rachmiel R, Trope GE, Buys YM, Flanagan JG, Chipman ML. Intermediate-term outcome and success of superior versus inferior Ahmed Glaucoma Valve implantation. J Glaucoma. 2008;17:584–90.CrossRefPubMed Rachmiel R, Trope GE, Buys YM, Flanagan JG, Chipman ML. Intermediate-term outcome and success of superior versus inferior Ahmed Glaucoma Valve implantation. J Glaucoma. 2008;17:584–90.CrossRefPubMed
21.
go back to reference Stewart WC, Kristoffersen CJ, Demos CM, Fsadni MG, Stewart JA. Incidence of conjunctival exposure following drainage device implantation in patients with glaucoma. Eur J Ophthalmol. 2010;20:124–30.PubMed Stewart WC, Kristoffersen CJ, Demos CM, Fsadni MG, Stewart JA. Incidence of conjunctival exposure following drainage device implantation in patients with glaucoma. Eur J Ophthalmol. 2010;20:124–30.PubMed
22.
go back to reference Lawrence SD, Netland PA. Gamma-irradiated cornea allograft for glaucoma surgery. J Glaucoma. 2013;22:355–7.CrossRefPubMed Lawrence SD, Netland PA. Gamma-irradiated cornea allograft for glaucoma surgery. J Glaucoma. 2013;22:355–7.CrossRefPubMed
23.
go back to reference Spierer O, Rachmiel R, Lazar M, Alba M, Varssano D. Double use of corneal graft for Descemet stripping automated endothelial keratoplasty and coverage of glaucoma drainage device tube. J Glaucoma. 2012;21:490–2.CrossRefPubMed Spierer O, Rachmiel R, Lazar M, Alba M, Varssano D. Double use of corneal graft for Descemet stripping automated endothelial keratoplasty and coverage of glaucoma drainage device tube. J Glaucoma. 2012;21:490–2.CrossRefPubMed
24.
go back to reference Anand A, Sheha H, Teng CC, Liebmann JM, Ritch R, Tello C. Use of amniotic membrane graft in glaucoma shunt surgery. Ophthalmic Surg Lasers Imaging. 2011;42:184–9.CrossRefPubMed Anand A, Sheha H, Teng CC, Liebmann JM, Ritch R, Tello C. Use of amniotic membrane graft in glaucoma shunt surgery. Ophthalmic Surg Lasers Imaging. 2011;42:184–9.CrossRefPubMed
25.
go back to reference Gupta VS, Sethi HS, Gupta M, Mehta A, Singh S, Yadav P, et al. Posterior migration of Ahmed glaucoma valve tube in a patient with Reiger anomaly: a case report. BMC Ophthalmol. 2010;10:23.PubMedCentralCrossRefPubMed Gupta VS, Sethi HS, Gupta M, Mehta A, Singh S, Yadav P, et al. Posterior migration of Ahmed glaucoma valve tube in a patient with Reiger anomaly: a case report. BMC Ophthalmol. 2010;10:23.PubMedCentralCrossRefPubMed
Metadata
Title
Partial thickness corneal tissue as a patch graft material for prevention of glaucoma drainage device exposure
Authors
Oriel Spierer
Michael Waisbourd
Yitzhak Golan
Hadas Newman
Rony Rachmiel
Publication date
01-12-2016
Publisher
BioMed Central
Published in
BMC Ophthalmology / Issue 1/2016
Electronic ISSN: 1471-2415
DOI
https://doi.org/10.1186/s12886-016-0196-2

Other articles of this Issue 1/2016

BMC Ophthalmology 1/2016 Go to the issue