Published in: Archives of Orthopaedic and Trauma Surgery 7/2010

01-07-2010 | Orthopaedic Outcome Assessment

Bone remodeling in proximal HA-coated versus uncoated cementless SL-Plus® femoral components: a 5-year follow-up study

Authors: W. Steens, A. G. Schneeberger, R. Skripitz, P. Fennema, C. Goetze

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 7/2010

Login to get access

Abstract

Background and purpose

Bone resorption at the femoral stem due to stress shielding has been particularly observed secondary to cementless hip replacement. This prospective study of 126 total-hip replacements was performed to examine clinical outcomes and changes in peri-prosthetic bone density after implantation of a double-tapered cementless femoral component manufactured with versus without hydroxyapatite (HA) coating.

Methods

Sixty-seven femoral components with and 59 femoral components without proximal HA coating were implanted and examined after a mean follow-up of 5.8 (SD 1.1, 2.8–7.8) years. The Harris hip score (HHS) and plain radiographs were used for clinical and radiological follow-up evaluations. Possible changes in peri-prosthetic bone mineral density (BMD) were measured by dual-energy X-ray absorptiometry (DEXA).

Results

Clinical outcome, measured by HHS, was similar in both groups. On plain radiographs, significantly less radiolucent lines were observed for the coated implants. DEXA revealed a significant increase in BMD at the proximal zones, along the medial side, and at the stem tips in the coated compared with the non-coated implants.

Interpretation

Hydroxyapatite-coated implants yield favorable radiographic characteristics, but no greater clinical benefit after 5 years’ implantation.
Literature
1.
go back to reference Bauer TW, Geesink RC, Zimmerman R, McMahon JT (1991) Hydroxyapatite-coated femoral stems: histological analysis of components retrieved at autopsy. J Bone Joint Surg Am 73:1439–1452PubMed Bauer TW, Geesink RC, Zimmerman R, McMahon JT (1991) Hydroxyapatite-coated femoral stems: histological analysis of components retrieved at autopsy. J Bone Joint Surg Am 73:1439–1452PubMed
2.
go back to reference Bergschmidt P, Bader R, Finze S, Gankovych A, Kundt G, Mittelmeier W (2010) Cementless total hip replacement: a prospective clinical study of the early functional and radiological outcomes of three different hip stems. Arch Orthop Trauma Surg 130:125–133CrossRef Bergschmidt P, Bader R, Finze S, Gankovych A, Kundt G, Mittelmeier W (2010) Cementless total hip replacement: a prospective clinical study of the early functional and radiological outcomes of three different hip stems. Arch Orthop Trauma Surg 130:125–133CrossRef
3.
go back to reference Bobyn JD, Mortimer ES, Glassman AH, Engh CA, Miller JE, Brooks CE (1992) Producing and avoiding stress shielding: laboratory and clinical observations of noncemented total hip arthroplasty. Clin Orthop 274:79–96PubMed Bobyn JD, Mortimer ES, Glassman AH, Engh CA, Miller JE, Brooks CE (1992) Producing and avoiding stress shielding: laboratory and clinical observations of noncemented total hip arthroplasty. Clin Orthop 274:79–96PubMed
4.
go back to reference Bobyn JD, Jacobs JJ, Tanzer M, Urban RM, Aribindi R, Sumner DR, Turner TM, Brooks CE (1995) The susceptibility of smooth implant surfaces to periimplant fibrosis and migration of polyethylene wear debris. Clin Orthop 311:21–39PubMed Bobyn JD, Jacobs JJ, Tanzer M, Urban RM, Aribindi R, Sumner DR, Turner TM, Brooks CE (1995) The susceptibility of smooth implant surfaces to periimplant fibrosis and migration of polyethylene wear debris. Clin Orthop 311:21–39PubMed
5.
go back to reference Brodner W, Bitzan P, Lomoschitz F, Krepler P, Jankovsky R, Lehr S, Kainberger F, Gottsauner-Wolf F (2004) Changes in bone mineral density in the proximal femur after cementless total hip arthroplasty: a five-year longitudinal study. J Bone Joint Surg Br 86:20–26PubMed Brodner W, Bitzan P, Lomoschitz F, Krepler P, Jankovsky R, Lehr S, Kainberger F, Gottsauner-Wolf F (2004) Changes in bone mineral density in the proximal femur after cementless total hip arthroplasty: a five-year longitudinal study. J Bone Joint Surg Br 86:20–26PubMed
6.
go back to reference Capello WN, D’Antonio JA, Manley MT, Feinberg JR (1998) Hydroxyapatite in total hip arthroplasty: clinical results and critical issues. Clin Orthop 355:200–211CrossRefPubMed Capello WN, D’Antonio JA, Manley MT, Feinberg JR (1998) Hydroxyapatite in total hip arthroplasty: clinical results and critical issues. Clin Orthop 355:200–211CrossRefPubMed
7.
go back to reference Coathup MJ, Blunn GW, Flynn N, Williams C, Thomas NP (2001) A comparison of bone remodelling around hydroxyapatite-coated, porous-coated and grit-blasted hip replacements retrieved at post-mortem. J Bone Joint Surg Br 83:118–123CrossRefPubMed Coathup MJ, Blunn GW, Flynn N, Williams C, Thomas NP (2001) A comparison of bone remodelling around hydroxyapatite-coated, porous-coated and grit-blasted hip replacements retrieved at post-mortem. J Bone Joint Surg Br 83:118–123CrossRefPubMed
8.
go back to reference Cohen B, Rushton N (1995) Accuracy of DEXA measurement of bone mineral density after total hip arthroplasty. J Bone Joint Surg Br 77:479–483PubMed Cohen B, Rushton N (1995) Accuracy of DEXA measurement of bone mineral density after total hip arthroplasty. J Bone Joint Surg Br 77:479–483PubMed
9.
go back to reference Dohle J, Becker W, Braun M (2001) Radiological analysis of osseointegration after implantation of the Zweymuller–Alloclassic total hip system. Z Orthop 139:517–524PubMed Dohle J, Becker W, Braun M (2001) Radiological analysis of osseointegration after implantation of the Zweymuller–Alloclassic total hip system. Z Orthop 139:517–524PubMed
10.
go back to reference Dorr LD, Wan Z, Song M, Ranawat A (1998) Bilateral total hip arthroplasty comparing hydroxyapatite coating to porous-coated fixation. J Arthroplasty 13:729–736CrossRefPubMed Dorr LD, Wan Z, Song M, Ranawat A (1998) Bilateral total hip arthroplasty comparing hydroxyapatite coating to porous-coated fixation. J Arthroplasty 13:729–736CrossRefPubMed
11.
go back to reference Dumbleton JH, Manley MT, Edidin AA (2002) A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 17:649–661CrossRefPubMed Dumbleton JH, Manley MT, Edidin AA (2002) A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 17:649–661CrossRefPubMed
12.
go back to reference Engh CA Jr, Sychterz C, Engh C Sr (1999) Factors affecting femoral bone remodeling after cementless total hip arthroplasty. J Arthroplasty 14:637–644CrossRefPubMed Engh CA Jr, Sychterz C, Engh C Sr (1999) Factors affecting femoral bone remodeling after cementless total hip arthroplasty. J Arthroplasty 14:637–644CrossRefPubMed
13.
go back to reference Furlong RJ, Osborn JF (1991) Fixation of hip prostheses by hydroxyapatite ceramic coatings. J Bone Joint Surg Br 73:741–745PubMed Furlong RJ, Osborn JF (1991) Fixation of hip prostheses by hydroxyapatite ceramic coatings. J Bone Joint Surg Br 73:741–745PubMed
14.
go back to reference Garcia-Cimbrelo E, Cruz-Pardos A, Madero R, Ortega-Andreu M (2003) Total hip arthroplasty with use of the cementless Zweymuller Alloclassic system: a ten to thirteen-year follow-up study. J Bone Joint Surg Am 85-A:296–303PubMed Garcia-Cimbrelo E, Cruz-Pardos A, Madero R, Ortega-Andreu M (2003) Total hip arthroplasty with use of the cementless Zweymuller Alloclassic system: a ten to thirteen-year follow-up study. J Bone Joint Surg Am 85-A:296–303PubMed
15.
go back to reference Geesink RG, Hoefnagels NH (1995) Six-year results of hydroxyapatite-coated total hip replacement. J Bone Joint Surg Br 77:534–547PubMed Geesink RG, Hoefnagels NH (1995) Six-year results of hydroxyapatite-coated total hip replacement. J Bone Joint Surg Br 77:534–547PubMed
16.
go back to reference Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 141:17–27 Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 141:17–27
17.
go back to reference Grübl A, Chiari C, Gruber M, Kaider A, Gottsauner-Wolf F (2002) Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up. J Bone Joint Surg Am 84-A:425–431PubMed Grübl A, Chiari C, Gruber M, Kaider A, Gottsauner-Wolf F (2002) Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up. J Bone Joint Surg Am 84-A:425–431PubMed
18.
go back to reference Herrera A, Canales V, Anderson J, Garcia-Araujo C, Murcia-Mazon A, Tonino AJ (2004) Seven to 10 years followup of an anatomic hip prosthesis: an international study. Clin Orthop 423:129–137CrossRefPubMed Herrera A, Canales V, Anderson J, Garcia-Araujo C, Murcia-Mazon A, Tonino AJ (2004) Seven to 10 years followup of an anatomic hip prosthesis: an international study. Clin Orthop 423:129–137CrossRefPubMed
19.
go back to reference Jaffe WL, Scott DF (1993) Rationale and clinical application of hydroxyapatite coatings in pressfit total hip arthroplasty. Semin Arthroplasty 4:159–166PubMed Jaffe WL, Scott DF (1993) Rationale and clinical application of hydroxyapatite coatings in pressfit total hip arthroplasty. Semin Arthroplasty 4:159–166PubMed
20.
go back to reference Karrholm J, Malchau H, Snorrason F, Herberts P (1994) Micromotion of femoral stems in total hip arthroplasty: a randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis. J Bone Joint Surg Am 76:1692–1705PubMed Karrholm J, Malchau H, Snorrason F, Herberts P (1994) Micromotion of femoral stems in total hip arthroplasty: a randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis. J Bone Joint Surg Am 76:1692–1705PubMed
21.
go back to reference Kim YH, Kim JS, Oh SH, Kim JM (2003) Comparison of porous-coated titanium femoral stems with and without hydroxyapatite coating. J Bone Joint Surg Am 85-A:1682–1688PubMed Kim YH, Kim JS, Oh SH, Kim JM (2003) Comparison of porous-coated titanium femoral stems with and without hydroxyapatite coating. J Bone Joint Surg Am 85-A:1682–1688PubMed
22.
go back to reference Kroger H, Miettinen H, Arnala I, Koski E, Rushton N, Suomalainen O (1996) Evaluation of periprosthetic bone using dual-energy X-ray absorptiometry: precision of the method and effect of operation on bone mineral density. J Bone Miner Res 11:1526–1530CrossRefPubMed Kroger H, Miettinen H, Arnala I, Koski E, Rushton N, Suomalainen O (1996) Evaluation of periprosthetic bone using dual-energy X-ray absorptiometry: precision of the method and effect of operation on bone mineral density. J Bone Miner Res 11:1526–1530CrossRefPubMed
23.
go back to reference Kroger H, Venesmaa P, Jurvelin J, Miettinen H, Suomalainen O, Alhava E (1998) Bone density at the proximal femur after total hip arthroplasty. Clin Orthop 352:66–74PubMed Kroger H, Venesmaa P, Jurvelin J, Miettinen H, Suomalainen O, Alhava E (1998) Bone density at the proximal femur after total hip arthroplasty. Clin Orthop 352:66–74PubMed
24.
go back to reference Kroon PO, Freeman MA (1992) Hydroxyapatite coating of hip prostheses: effect on migration into the femur. J Bone Joint Surg Br 74:518–522PubMed Kroon PO, Freeman MA (1992) Hydroxyapatite coating of hip prostheses: effect on migration into the femur. J Bone Joint Surg Br 74:518–522PubMed
25.
go back to reference Mirsky EC, Einhorn TA (1998) Bone densitometry in orthopaedic practice. J Bone Joint Surg Am 80:1687–1698PubMed Mirsky EC, Einhorn TA (1998) Bone densitometry in orthopaedic practice. J Bone Joint Surg Am 80:1687–1698PubMed
26.
go back to reference McPherson EJ, Dorr LD, Gruen TA, Saberi MT (1995) Hydroxyapatite-coated proximal ingrowth femoral stems: a matched pair control study. Clin Orthop 315:223–230PubMed McPherson EJ, Dorr LD, Gruen TA, Saberi MT (1995) Hydroxyapatite-coated proximal ingrowth femoral stems: a matched pair control study. Clin Orthop 315:223–230PubMed
27.
go back to reference Palm L, Jacobsson SA, Ivarsson I (2002) Hydroxyapatite coating improves 8- to 10-year performance of the link RS cementless femoral stem. J Arthroplasty 17:172–175CrossRefPubMed Palm L, Jacobsson SA, Ivarsson I (2002) Hydroxyapatite coating improves 8- to 10-year performance of the link RS cementless femoral stem. J Arthroplasty 17:172–175CrossRefPubMed
28.
go back to reference Parvizi J, Sharkey PF, Hozack WJ, Orzoco F, Bissett GA, Rothman RH (2004) Prospective matched-pair analysis of hydroxyapatite-coated and uncoated femoral stems in total hip arthroplasty: a concise follow-up of a previous report. J Bone Joint Surg Am 86-A:783–786PubMed Parvizi J, Sharkey PF, Hozack WJ, Orzoco F, Bissett GA, Rothman RH (2004) Prospective matched-pair analysis of hydroxyapatite-coated and uncoated femoral stems in total hip arthroplasty: a concise follow-up of a previous report. J Bone Joint Surg Am 86-A:783–786PubMed
29.
go back to reference Pieringer H, Auersperg V, Labek G, Bohler N (2004) Radiological appearance of the cementless ALLOCLASSIC SL-stem implanted in very old patients with primary hip osteoarthritis. Z Orthop 142:322–327CrossRefPubMed Pieringer H, Auersperg V, Labek G, Bohler N (2004) Radiological appearance of the cementless ALLOCLASSIC SL-stem implanted in very old patients with primary hip osteoarthritis. Z Orthop 142:322–327CrossRefPubMed
30.
go back to reference Pospischill M, Knahr K (2005) Cementless total hip arthroplasty using a threaded cup and a rectangular tapered stem: follow-up for ten to 17 years. J Bone Joint Surg Br 87:1210–1215CrossRefPubMed Pospischill M, Knahr K (2005) Cementless total hip arthroplasty using a threaded cup and a rectangular tapered stem: follow-up for ten to 17 years. J Bone Joint Surg Br 87:1210–1215CrossRefPubMed
31.
go back to reference Rahmy AI, Gosens T, Blake GM, Tonino A, Fogelman I (2004) Periprosthetic bone remodelling of two types of uncemented femoral implant with proximal hydroxyapatite coating: a 3-year follow-up study addressing the influence of prosthesis design and preoperative bone density on periprosthetic bone loss. Osteoporos Int 15:281–289CrossRefPubMed Rahmy AI, Gosens T, Blake GM, Tonino A, Fogelman I (2004) Periprosthetic bone remodelling of two types of uncemented femoral implant with proximal hydroxyapatite coating: a 3-year follow-up study addressing the influence of prosthesis design and preoperative bone density on periprosthetic bone loss. Osteoporos Int 15:281–289CrossRefPubMed
32.
go back to reference Roth A, Winzer T, Babisch J, Fuhrmann R, Sander K, Venbrocks R (2005) Radiological changes around the stem after cementless hip implantation in case of the anatomic medullary locking hip system—five years results. Acta Chir Orthop Traumatol Cech 72:42–46PubMed Roth A, Winzer T, Babisch J, Fuhrmann R, Sander K, Venbrocks R (2005) Radiological changes around the stem after cementless hip implantation in case of the anatomic medullary locking hip system—five years results. Acta Chir Orthop Traumatol Cech 72:42–46PubMed
33.
go back to reference Rothman RH, Hozack WJ, Ranawat A, Moriarty L (1996) Hydroxyapatite-coated femoral stems: a matched-pair analysis of coated and uncoated implants. J Bone Joint Surg Am 78:319–324PubMed Rothman RH, Hozack WJ, Ranawat A, Moriarty L (1996) Hydroxyapatite-coated femoral stems: a matched-pair analysis of coated and uncoated implants. J Bone Joint Surg Am 78:319–324PubMed
34.
go back to reference Smart RC, Barbagallo S, Slater GL, Kuo RS, Butler SP, Drummond RP, Sekel R (1996) Measurement of periprosthetic bone density in hip arthroplasty using dual-energy X-ray absorptiometry: reproducibility of measurements. J Arthroplasty 11:445–452CrossRefPubMed Smart RC, Barbagallo S, Slater GL, Kuo RS, Butler SP, Drummond RP, Sekel R (1996) Measurement of periprosthetic bone density in hip arthroplasty using dual-energy X-ray absorptiometry: reproducibility of measurements. J Arthroplasty 11:445–452CrossRefPubMed
35.
go back to reference Soballe K, Toksvig-Larsen S, Gelineck J, Fruensgaard S, Hansen ES, Ryd L, Lucht U, Bunger C (1993) Migration of hydroxyapatite coated femoral prostheses: a Roentgen stereophotogrammetric study. J Bone Joint Surg Br 75:681–687PubMed Soballe K, Toksvig-Larsen S, Gelineck J, Fruensgaard S, Hansen ES, Ryd L, Lucht U, Bunger C (1993) Migration of hydroxyapatite coated femoral prostheses: a Roentgen stereophotogrammetric study. J Bone Joint Surg Br 75:681–687PubMed
36.
go back to reference Soderman P, Malchau H (2001) Is the Harris hip score system useful to study the outcome of total hip replacement? Clin Orthop 384:189–197CrossRefPubMed Soderman P, Malchau H (2001) Is the Harris hip score system useful to study the outcome of total hip replacement? Clin Orthop 384:189–197CrossRefPubMed
37.
go back to reference Tanzer M, Gollish J, Leighton R, Orrell K, Giacchino A, Welsh P, Shea B, Wells G (2004) The effect of adjuvant calcium phosphate coating on a porous-coated femoral stem. Clin Orthop 424:153–160CrossRefPubMed Tanzer M, Gollish J, Leighton R, Orrell K, Giacchino A, Welsh P, Shea B, Wells G (2004) The effect of adjuvant calcium phosphate coating on a porous-coated femoral stem. Clin Orthop 424:153–160CrossRefPubMed
38.
go back to reference Venesmaa PK, Kroger HP, Miettinen HJ, Jurvelin JS, Suomalainen OT, Alhava EM (2001) Monitoring of periprosthetic BMD after uncemented total hip arthroplasty with dual-energy X-ray absorptiometry—a 3-year follow-up study. J Bone Miner Res 16:1056–1061CrossRefPubMed Venesmaa PK, Kroger HP, Miettinen HJ, Jurvelin JS, Suomalainen OT, Alhava EM (2001) Monitoring of periprosthetic BMD after uncemented total hip arthroplasty with dual-energy X-ray absorptiometry—a 3-year follow-up study. J Bone Miner Res 16:1056–1061CrossRefPubMed
39.
go back to reference Vervest TM, Van Heeswijk WHJC, Anderson PG, Van Limbeek J (2003) Bone mineral density 10 years after a Zweymüller uncemented stem prosthesis. Hip Int 13:205–214 Vervest TM, Van Heeswijk WHJC, Anderson PG, Van Limbeek J (2003) Bone mineral density 10 years after a Zweymüller uncemented stem prosthesis. Hip Int 13:205–214
40.
go back to reference Yee AJ, Kreder HK, Bookman I, Davey JR (1999) A randomized trial of hydroxyapatite coated prostheses in total hip arthroplasty. Clin Orthop 366:120–132CrossRefPubMed Yee AJ, Kreder HK, Bookman I, Davey JR (1999) A randomized trial of hydroxyapatite coated prostheses in total hip arthroplasty. Clin Orthop 366:120–132CrossRefPubMed
41.
go back to reference Zwatelé RE, Olsthoorn PGM, Pöll RG, Brand R, Doets HC (2008) Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6–10 years follow-up. Arch Orthop Trauma Surg 128:1379–1386CrossRef Zwatelé RE, Olsthoorn PGM, Pöll RG, Brand R, Doets HC (2008) Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6–10 years follow-up. Arch Orthop Trauma Surg 128:1379–1386CrossRef
42.
go back to reference Zweymuller KA, Schwarzinger UM, Steindl MS (2006) Radiolucent lines and osteolysis along tapered straight cementless titanium hip stems: a comparison of 6-year and 10-year follow-up results in 95 patients. Acta Orthop 77:871–876CrossRefPubMed Zweymuller KA, Schwarzinger UM, Steindl MS (2006) Radiolucent lines and osteolysis along tapered straight cementless titanium hip stems: a comparison of 6-year and 10-year follow-up results in 95 patients. Acta Orthop 77:871–876CrossRefPubMed
Metadata
Title
Bone remodeling in proximal HA-coated versus uncoated cementless SL-Plus® femoral components: a 5-year follow-up study
Authors
W. Steens
A. G. Schneeberger
R. Skripitz
P. Fennema
C. Goetze
Publication date
01-07-2010
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 7/2010
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-009-1040-4

Other articles of this Issue 7/2010

Archives of Orthopaedic and Trauma Surgery 7/2010 Go to the issue