Open Access 29-06-2022 | Transcatheter Aortic Valve Implantation | Original Paper

Bioprosthetic valve dysfunction and failure after TAVI in bicuspid aortic valve stenosis during one-year follow-up according to VARC-3

Authors: Verena Veulemans, Philippe Nuyens, Shouheng Goh, Oliver Maier, Stephan Binnebößel, Jacqueline Heermann, Christian Jung, Ralf Westenfeld, Malte Kelm, Ole de Backer, Tobias Zeus

Published in: Clinical Research in Cardiology | Issue 12/2022

Login to get access

Abstract

Background

Transcatheter aortic valve implantation (TAVI) in bicuspid aortic valve (BAV) stenosis has become more frequent in the last years. This may pose challenges for long-time valve durability. Therefore, we aimed to evaluate the prevalence of bioprosthetic valve dysfunction (BVD) with the newest-generation devices in BAV stenosis up to one-year follow-up (FU).

Methods

The primary endpoint was defined as the prevalence of BVD during the first procedural year according to Valve Academic Research Consortium (VARC)-3 criteria. Secondary endpoints were defined as failure in device success and clinical endpoints according to VARC-3.

Results

A total of 107 patients were included. Of these, 34 subjects (31.8%) met the criteria for BVD during a mean FU of 263 ± 180 days, of which 20.2% were already documented after thirty days. Device success after one year was lower in the + BVD cohort (57.6% vs. 98.7%, p < 0.0001*). The rates of structural valve deterioration were 6.5%, non-structural valve deterioration (NSVD) 17.8%, subclinical leaflet thickening 10.3%, and endocarditis 0.9%. NSVD was foremost triggered by patient prosthesis mismatch in balloon-expandable valves. Hemodynamic valve deterioration stage 1 and 2 was confirmed in 16.8% of + BVD patients, while stage 1 and 3 bioprosthetic valve failure occurred in 1.9%. There was no impact of BVD on mortality.

Conclusion

There is critical evidence of early BVD after TAVI in BAV during one-year FU in one-third of patients, also lowering device success. The most frequently observed bioprosthetic valve dysfunction was NSVD due to patient prosthesis mismatch following TAVI with a balloon-expandable valve.
Appendix
Available only for authorised users
Literature
2.
8.
go back to reference Capodanno D, Petronio AS, Prendergast B et al (2017) Standardized definitions of structural deterioration and valve failure in assessing long-term durability of transcatheter and surgical aortic bioprosthetic valves: a consensus statement from the European association of percutaneous cardiovascular interventions (EAPCI) endorsed by the European society of cardiology (ESC) and the European association for cardio-thoracic surgery (EACTS). Eur Heart J 38:3382–3390. https://doi.org/10.1093/eurheartj/ehx303CrossRefPubMed Capodanno D, Petronio AS, Prendergast B et al (2017) Standardized definitions of structural deterioration and valve failure in assessing long-term durability of transcatheter and surgical aortic bioprosthetic valves: a consensus statement from the European association of percutaneous cardiovascular interventions (EAPCI) endorsed by the European society of cardiology (ESC) and the European association for cardio-thoracic surgery (EACTS). Eur Heart J 38:3382–3390. https://​doi.​org/​10.​1093/​eurheartj/​ehx303CrossRefPubMed
17.
go back to reference Prasitlumkum N, Thangjui S, Leesutipornchai T, Kewcharoen J, Limpruttidham N, Pai RG (2021) Comparison of infective endocarditis risk between balloon and self-expandable valves following transcatheter aortic valve replacement: systematic review and meta-analysis. Cardiovasc Interv Ther 36:363–374. https://doi.org/10.1007/s12928-020-00675-1CrossRefPubMed Prasitlumkum N, Thangjui S, Leesutipornchai T, Kewcharoen J, Limpruttidham N, Pai RG (2021) Comparison of infective endocarditis risk between balloon and self-expandable valves following transcatheter aortic valve replacement: systematic review and meta-analysis. Cardiovasc Interv Ther 36:363–374. https://​doi.​org/​10.​1007/​s12928-020-00675-1CrossRefPubMed
Metadata
Title
Bioprosthetic valve dysfunction and failure after TAVI in bicuspid aortic valve stenosis during one-year follow-up according to VARC-3
Authors
Verena Veulemans
Philippe Nuyens
Shouheng Goh
Oliver Maier
Stephan Binnebößel
Jacqueline Heermann
Christian Jung
Ralf Westenfeld
Malte Kelm
Ole de Backer
Tobias Zeus
Publication date
29-06-2022
Publisher
Springer Berlin Heidelberg
Published in
Clinical Research in Cardiology / Issue 12/2022
Print ISSN: 1861-0684
Electronic ISSN: 1861-0692
DOI
https://doi.org/10.1007/s00392-022-02052-9

Other articles of this Issue 12/2022

Clinical Research in Cardiology 12/2022 Go to the issue