Abstract

Objectives

Analysis of timing, type, electrocardiographic and patient characteristics of postinterventional bradyarrhythmias after CoreValve implantation.

Background

Transcatheter aortic valve implantation (TAVI) has become an accepted alternative to surgical therapy in patients with high risk. Among the major drawbacks of this procedure is the need for postprocedural permanent pacemaker implantation (PPM). Although predictors for the postinterventional need for PPM are increasingly recognized, thresholds and rates may vary between centers.

Methods

We conducted a retrospective single-center analysis in 130 consecutive patients with successful transfemoral CoreValve implantation without preexisting pacemaker implants.

Results

Postprocedural bradyarrhythmias occurred in 36.2% post-TAVI. Compared to those without postinterventional bradyarrhythmias, these patients had longer preprocedural PR intervals (P = 0.012), broader QRS-complexes (P = 0.001) and prolonged QTc intervals (P = 0.001). Patients with postinterventional bradyarrhythmias had significantly more often preprocedural RBBB (35.2 vs. 14.1%; P = 0.0059). In contrast, no difference was observed with respect to annulus/prosthesis ratio or the use of the large 29-mm prosthesis. The vast majority of patients developed bradyarrhythmias directly after CoreValve implantation or within the first 48 h thereafter. However, 7.6% developed significant bradyarrhythmia more than 48 h after TAVI, and 3.8% of the whole cohort developed significant bradyarrhythmias even >96 h after TAVI. One patient died at day 5 post-TAVI due to asystole.

Conclusions

Late occurrence of bradyarrhythmias should be recognized as a significant contributor to postprocedural outcome after TAVI. Although this is a well known phenomenon after surgical valve replacement, it is less recognized after TAVI.
Literature
1.
go back to reference Krane M, Deutsch MA, Bleiziffer S, Schneider L, Ruge H, Mazzitelli D, Schreiber C, Brockmann G, Voss B, Bauernschmitt R, Lange R (2010) Quality of life among patients undergoing transcatheter aortic valve implantation. Am Heart J 160:451–457PubMedCrossRef Krane M, Deutsch MA, Bleiziffer S, Schneider L, Ruge H, Mazzitelli D, Schreiber C, Brockmann G, Voss B, Bauernschmitt R, Lange R (2010) Quality of life among patients undergoing transcatheter aortic valve implantation. Am Heart J 160:451–457PubMedCrossRef
2.
go back to reference Bekeredjian R, Krumsdorf U, Chorianopoulos E, Kallenbach K, Karck M, Katus HA, Rottbauer W (2010) Usefulness of percutaneous aortic valve implantation to improve quality of life in patients >80 years of age. Am J Cardiol 106:1777–1781PubMedCrossRef Bekeredjian R, Krumsdorf U, Chorianopoulos E, Kallenbach K, Karck M, Katus HA, Rottbauer W (2010) Usefulness of percutaneous aortic valve implantation to improve quality of life in patients >80 years of age. Am J Cardiol 106:1777–1781PubMedCrossRef
3.
go back to reference Figulla L, Neumann A, Figulla HR, Kahlert P, Erbel R, Neumann T (2011) Transcatheter aortic valve implantation: evidence on safety and efficacy compared with medical therapy. A systematic review of current literature. Clin Res Cardiol 100:265–276PubMedCrossRef Figulla L, Neumann A, Figulla HR, Kahlert P, Erbel R, Neumann T (2011) Transcatheter aortic valve implantation: evidence on safety and efficacy compared with medical therapy. A systematic review of current literature. Clin Res Cardiol 100:265–276PubMedCrossRef
4.
go back to reference Tamburino C, Capodanno D, Ramondo A, Petronio AS, Ettori F, Santoro G, Klugmann S, Bedogni F, Maisano F, Marzocchi A, Poli A, Antoniucci D, Napodano M, De Carlo M, Fiorina C, Ussia GP (2011) Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation 123:299–308PubMedCrossRef Tamburino C, Capodanno D, Ramondo A, Petronio AS, Ettori F, Santoro G, Klugmann S, Bedogni F, Maisano F, Marzocchi A, Poli A, Antoniucci D, Napodano M, De Carlo M, Fiorina C, Ussia GP (2011) Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation 123:299–308PubMedCrossRef
5.
go back to reference Nuis RJ, Piazza N, Van Mieghem NM, Otten AM, Tzikas A, Schultz CJ, van der Boon R, van Geuns RJ, van Domburg RT, Koudstaal PJ, Kappetein AP, Serruys PW, de Jaegere PP (2011) In-hospital complications after transcatheter aortic valve implantation revisited according to the valve academic research consortium definitions. Catheter Cardiovasc Interv 78:457–467PubMed Nuis RJ, Piazza N, Van Mieghem NM, Otten AM, Tzikas A, Schultz CJ, van der Boon R, van Geuns RJ, van Domburg RT, Koudstaal PJ, Kappetein AP, Serruys PW, de Jaegere PP (2011) In-hospital complications after transcatheter aortic valve implantation revisited according to the valve academic research consortium definitions. Catheter Cardiovasc Interv 78:457–467PubMed
6.
go back to reference Wenaweser P, Pilgrim T, Roth N, Kadner A, Stortecky S, Kalesan B, Meuli F, Büllesfeld L, Khattab AA, Huber C, Eberle B, Erdös G, Meier B, Jüni P, Carrel T, Windecker S (2011) Clinical outcome and predictors for adverse events after transcatheter aortic valve implantation with the use of different devices and access routes. Am Heart J 161:1114–1124PubMedCrossRef Wenaweser P, Pilgrim T, Roth N, Kadner A, Stortecky S, Kalesan B, Meuli F, Büllesfeld L, Khattab AA, Huber C, Eberle B, Erdös G, Meier B, Jüni P, Carrel T, Windecker S (2011) Clinical outcome and predictors for adverse events after transcatheter aortic valve implantation with the use of different devices and access routes. Am Heart J 161:1114–1124PubMedCrossRef
7.
go back to reference Fraccaro C, Buja G, Tarantini G, Gasparetto V, Leoni L, Razzolini R, Corrado D, Bonato R, Basso C, Thiene G, Gerosa G, Isabella G, Iliceto S, Napodano M (2011) Incidence, predictors, and outcome of conduction disorders after transcatheter self-expandable aortic valve implantation. Am J Cardiol 107:747–754PubMedCrossRef Fraccaro C, Buja G, Tarantini G, Gasparetto V, Leoni L, Razzolini R, Corrado D, Bonato R, Basso C, Thiene G, Gerosa G, Isabella G, Iliceto S, Napodano M (2011) Incidence, predictors, and outcome of conduction disorders after transcatheter self-expandable aortic valve implantation. Am J Cardiol 107:747–754PubMedCrossRef
8.
go back to reference Ferreira ND, Caeiro D, Adão L, Oliveira M, Gonçalves H, Ribeiro J, Teixeira M, Albuquerque A, Primo J, Braga P, Simões L, Ribeiro VG (2010) Incidence and predictors of permanent pacemaker requirement after transcatheter aortic valve implantation with a self-expanding bioprosthesis. Pacing Clin Electrophysiol 33:1364–1372PubMedCrossRef Ferreira ND, Caeiro D, Adão L, Oliveira M, Gonçalves H, Ribeiro J, Teixeira M, Albuquerque A, Primo J, Braga P, Simões L, Ribeiro VG (2010) Incidence and predictors of permanent pacemaker requirement after transcatheter aortic valve implantation with a self-expanding bioprosthesis. Pacing Clin Electrophysiol 33:1364–1372PubMedCrossRef
9.
go back to reference Jilaihawi H, Chin D, Vasa-Nicotera M, Jeilan M, Spyt T, Ng GA, Bence J, Logtens E, Kovac J (2009) Predictors for permanent pacemaker requirement after transcatheter aortic valve implantation with the CoreValve bioprosthesis. Am Heart J 157:860–866PubMedCrossRef Jilaihawi H, Chin D, Vasa-Nicotera M, Jeilan M, Spyt T, Ng GA, Bence J, Logtens E, Kovac J (2009) Predictors for permanent pacemaker requirement after transcatheter aortic valve implantation with the CoreValve bioprosthesis. Am Heart J 157:860–866PubMedCrossRef
10.
go back to reference Khawaja MZ, Rajani R, Cook A, Khavandi A, Moynagh A, Chowdhary S, Spence MS, Brown S, Khan SQ, Walker N, Trivedi U, Hutchinson N, De Belder AJ, Moat N, Blackman DJ, Levy RD, Manoharan G, Roberts D, Khogali SS, Crean P, Brecker SJ, Baumbach A, Mullen M, Laborde JC, Hildick-Smith D (2011) Permanent pacemaker insertion after CoreValve transcatheter aortic valve implantation: incidence and contributing factors (the UK CoreValve Collaborative). Circulation 123:951–960PubMedCrossRef Khawaja MZ, Rajani R, Cook A, Khavandi A, Moynagh A, Chowdhary S, Spence MS, Brown S, Khan SQ, Walker N, Trivedi U, Hutchinson N, De Belder AJ, Moat N, Blackman DJ, Levy RD, Manoharan G, Roberts D, Khogali SS, Crean P, Brecker SJ, Baumbach A, Mullen M, Laborde JC, Hildick-Smith D (2011) Permanent pacemaker insertion after CoreValve transcatheter aortic valve implantation: incidence and contributing factors (the UK CoreValve Collaborative). Circulation 123:951–960PubMedCrossRef
11.
go back to reference Nuis RJ, Van Mieghem NM, Schultz CJ, Tzikas A, Van der Boon RM, Maugenest AM, Cheng J, Piazza N, van Domburg RT, Serruys PW, de Jaegere PP (2011) Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis. Eur Heart J 32:2067–2074PubMedCrossRef Nuis RJ, Van Mieghem NM, Schultz CJ, Tzikas A, Van der Boon RM, Maugenest AM, Cheng J, Piazza N, van Domburg RT, Serruys PW, de Jaegere PP (2011) Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis. Eur Heart J 32:2067–2074PubMedCrossRef
12.
go back to reference Roten L, Wenaweser P, Delacrétaz E, Hellige G, Stortecky S, Tanner H, Pilgrim T, Kadner A, Eberle B, Zwahlen M, Carrel T, Meier B, Windecker S (2010) Incidence and predictors of atrioventricular conduction impairment after transcatheter aortic valve implantation. Am J Cardiol 106:1473–1480PubMedCrossRef Roten L, Wenaweser P, Delacrétaz E, Hellige G, Stortecky S, Tanner H, Pilgrim T, Kadner A, Eberle B, Zwahlen M, Carrel T, Meier B, Windecker S (2010) Incidence and predictors of atrioventricular conduction impairment after transcatheter aortic valve implantation. Am J Cardiol 106:1473–1480PubMedCrossRef
13.
go back to reference Bleiziffer S, Ruge H, Hörer J, Hutter A, Geisbüsch S, Brockmann G, Mazzitelli D, Bauernschmitt R, Lange R (2010) Predictors for new-onset complete heart block after transcatheter aortic valve implantation. JACC Cardiovasc Interv 3:524–530PubMedCrossRef Bleiziffer S, Ruge H, Hörer J, Hutter A, Geisbüsch S, Brockmann G, Mazzitelli D, Bauernschmitt R, Lange R (2010) Predictors for new-onset complete heart block after transcatheter aortic valve implantation. JACC Cardiovasc Interv 3:524–530PubMedCrossRef
14.
go back to reference Rubín JM, Avanzas P, Del Valle R, Renilla A, Ríos E, Calvo D, Lozano I, Anguera I, Díaz-Molina B, Cequier A, Morís de la Tassa C (2011) Atrioventricular conduction disturbance characterization in transcatheter aortic valve implantation with the CoreValve prosthesis. Circ Cardiovasc Interv 4:280–286PubMedCrossRef Rubín JM, Avanzas P, Del Valle R, Renilla A, Ríos E, Calvo D, Lozano I, Anguera I, Díaz-Molina B, Cequier A, Morís de la Tassa C (2011) Atrioventricular conduction disturbance characterization in transcatheter aortic valve implantation with the CoreValve prosthesis. Circ Cardiovasc Interv 4:280–286PubMedCrossRef
15.
go back to reference Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, Brown DL, Block PC, Guyton RA, Pichard AD, Bavaria JE, Herrmann HC, Douglas PS, Petersen JL, Akin JJ, Anderson WN, Wang D, Pocock S, PARTNER Trial Investigators (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363:1597–1607PubMedCrossRef Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, Brown DL, Block PC, Guyton RA, Pichard AD, Bavaria JE, Herrmann HC, Douglas PS, Petersen JL, Akin JJ, Anderson WN, Wang D, Pocock S, PARTNER Trial Investigators (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363:1597–1607PubMedCrossRef
Metadata
Title
Incidence of late occurring bradyarrhythmias after TAVI with the self-expanding CoreValve® aortic bioprosthesis
Authors
Emmanuel Chorianopoulos
Ulrike Krumsdorf
Sven T. Pleger
Hugo A. Katus
Raffi Bekeredjian
Publication date
01-05-2012
Publisher
Springer-Verlag
Published in
Clinical Research in Cardiology / Issue 5/2012
Print ISSN: 1861-0684
Electronic ISSN: 1861-0692
DOI
https://doi.org/10.1007/s00392-011-0398-9

Other articles of this Issue 5/2012

Clinical Research in Cardiology 5/2012 Go to the issue