Skip to main content
Top
Published in: Heart and Vessels 11/2019

01-11-2019 | Intravascular Ultrasound | Original Article

Real-world use of intravascular ultrasound in Japan: a report from contemporary multicenter PCI registry

Authors: Toshiki Kuno, Yohei Numasawa, Mitsuaki Sawano, Takayuki Abe, Ikuko Ueda, Masaki Kodaira, Masahiro Suzuki, Shigetaka Noma, Iwao Nakamura, Koji Negishi, Shiro Ishikawa, Keiichi Fukuda, Shun Kohsaka

Published in: Heart and Vessels | Issue 11/2019

Login to get access

Abstract

Clinical trial data suggest that intravascular ultrasound (IVUS) may improve clinical outcomes after PCI. The aim of this study was to investigate the safety of IVUS in its broader use for percutaneous coronary intervention (PCI). A total of 11,570 consecutive patients undergoing PCI between 2008 and 2014 in Japan were analyzed. Associations between IVUS use, PCI-related complications were assessed with logistic regression and propensity score matching analyses. Subgroup analysis was performed in elective PCI patients. IVUS was used in 84.8% of patients (N = 9814; IVUS group); its use was almost universal in elective PCIs (90.8 vs. 81.7% in urgent/emergent PCIs, P < 0.001). The non-IVUS group were older (68.7 ± 11.4 vs. 67.9 ± 10.8 years, P = 0.004), with more comorbid conditions. The non-IVUS group had smaller stent lumens (2.97 ± 0.42 mm vs. 3.09 ± 0.45 mm, P < 0.001) and a higher proportion of plain old balloon angioplasty. After matching, a lower rate of flow-impairing coronary dissections was observed in the IVUS group, although this was limited only to elective PCIs, not among urgent/emergent PCIs (non-IVUS vs. IVUS; 2.7% vs. 1.0%, P = 0.018, 0.7% vs. 1.2%, P = 0.32, respectively). With a multivariate logistic regression analysis, IVUS use remained an independent predictor to reduce risk of flow impairing severe coronary dissection among elective PCIs (odds ratio 0.38, 95% confidence interval 0.22–0.66: P = 0.001). In this Japanese PCI registry, IVUS was used extensively during the study period, particularly in elective cases. Using IVUS was associated with a lower event rate of flow-impairing coronary dissections that was limited to elective PCIs, not among urgent/emergent PCIs, without increasing PCI-related complications.
Literature
1.
go back to reference Uren NG, Schwarzacher SP, Metz JA, Lee DP, Honda Y, Yeung AC, Fitzgerald PJ, Yock PG, Investigators PR (2002) Predictors and outcomes of stent thrombosis: an intravascular ultrasound registry. Eur Heart J 23:124–132CrossRef Uren NG, Schwarzacher SP, Metz JA, Lee DP, Honda Y, Yeung AC, Fitzgerald PJ, Yock PG, Investigators PR (2002) Predictors and outcomes of stent thrombosis: an intravascular ultrasound registry. Eur Heart J 23:124–132CrossRef
2.
go back to reference Fujii K, Carlier SG, Mintz GS, Yang YM, Moussa I, Weisz G, Dangas G, Mehran R, Lansky AJ, Kreps EM, Collins M, Stone GW, Moses JW, Leon MB (2005) Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study. J Am Coll Cardiol 45:995–998CrossRef Fujii K, Carlier SG, Mintz GS, Yang YM, Moussa I, Weisz G, Dangas G, Mehran R, Lansky AJ, Kreps EM, Collins M, Stone GW, Moses JW, Leon MB (2005) Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study. J Am Coll Cardiol 45:995–998CrossRef
3.
go back to reference Sonoda S, Morino Y, Ako J, Terashima M, Hassan AH, Bonneau HN, Leon MB, Moses JW, Yock PG, Honda Y, Kuntz RE, Fitzgerald PJ, Investigators S (2004) Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial. J Am Coll Cardiol 43:1959–1963CrossRef Sonoda S, Morino Y, Ako J, Terashima M, Hassan AH, Bonneau HN, Leon MB, Moses JW, Yock PG, Honda Y, Kuntz RE, Fitzgerald PJ, Investigators S (2004) Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial. J Am Coll Cardiol 43:1959–1963CrossRef
4.
go back to reference Hong SJ, Kim BK, Shin DH, Nam CM, Kim JS, Ko YG, Choi D, Kang TS, Kang WC, Her AY, Kim Y, Hur SH, Hong BK, Kwon H, Jang Y, Hong MK, IVUS-XPL Investigators (2015) Effect of intravascular ultrasound-guided vs angiography-guided everolimus-eluting stent implantation: the IVUS-XPL randomized clinical trial. JAMA 314(20):2155–2163CrossRef Hong SJ, Kim BK, Shin DH, Nam CM, Kim JS, Ko YG, Choi D, Kang TS, Kang WC, Her AY, Kim Y, Hur SH, Hong BK, Kwon H, Jang Y, Hong MK, IVUS-XPL Investigators (2015) Effect of intravascular ultrasound-guided vs angiography-guided everolimus-eluting stent implantation: the IVUS-XPL randomized clinical trial. JAMA 314(20):2155–2163CrossRef
5.
go back to reference Zhang Y, Farooq V, Garcia-Garcia HM, Bourantas CV, Tian N, Dong S, Li M, Yang S, Serruys PW, Chen SL (2012) Comparison of intravascular ultrasound versus angiography-guided drug-eluting stent implantation: a meta-analysis of one randomised trial and ten observational studies involving 19,619 patients. EuroIntervention 8:855–865CrossRef Zhang Y, Farooq V, Garcia-Garcia HM, Bourantas CV, Tian N, Dong S, Li M, Yang S, Serruys PW, Chen SL (2012) Comparison of intravascular ultrasound versus angiography-guided drug-eluting stent implantation: a meta-analysis of one randomised trial and ten observational studies involving 19,619 patients. EuroIntervention 8:855–865CrossRef
6.
go back to reference Klersy C, Ferlini M, Raisaro A, Scotti V, Balduini A, Curti M, Bramucci E, De Silvestri A (2013) Use of IVUS guided coronary stenting with drug eluting stent: a systematic review and meta-analysis of randomized controlled clinical trials and high quality observational studies. Int J Cardiol 170:54–63CrossRef Klersy C, Ferlini M, Raisaro A, Scotti V, Balduini A, Curti M, Bramucci E, De Silvestri A (2013) Use of IVUS guided coronary stenting with drug eluting stent: a systematic review and meta-analysis of randomized controlled clinical trials and high quality observational studies. Int J Cardiol 170:54–63CrossRef
7.
go back to reference Jang JS, Song YJ, Kang W, Jin HY, Seo JS, Yang TH, Kim DK, Cho KI, Kim BH, Park YH, Je HG, Kim DS (2014) Intravascular ultrasound-guided implantation of drug-eluting stents to improve outcome: a meta-analysis. JACC Cardiovasc Interv 7:233–243CrossRef Jang JS, Song YJ, Kang W, Jin HY, Seo JS, Yang TH, Kim DK, Cho KI, Kim BH, Park YH, Je HG, Kim DS (2014) Intravascular ultrasound-guided implantation of drug-eluting stents to improve outcome: a meta-analysis. JACC Cardiovasc Interv 7:233–243CrossRef
8.
go back to reference Ahn JM, Kang SJ, Yoon SH, Park HW, Kang SM, Lee JY, Lee SW, Kim YH, Lee CW, Park SW, Mintz GS, Park SJ (2014) Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies. Am J Cardiol 113:1338–1347CrossRef Ahn JM, Kang SJ, Yoon SH, Park HW, Kang SM, Lee JY, Lee SW, Kim YH, Lee CW, Park SW, Mintz GS, Park SJ (2014) Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies. Am J Cardiol 113:1338–1347CrossRef
9.
go back to reference Park KW, Kang SH, Yang HM, Lee HY, Kang HJ, Cho YS, Youn TJ, Koo BK, Chae IH, Kim HS (2013) Impact of intravascular ultrasound guidance in routine percutaneous coronary intervention for conventional lesions: data from the EXCELLENT trial. Int J Cardiol 167:721–726CrossRef Park KW, Kang SH, Yang HM, Lee HY, Kang HJ, Cho YS, Youn TJ, Koo BK, Chae IH, Kim HS (2013) Impact of intravascular ultrasound guidance in routine percutaneous coronary intervention for conventional lesions: data from the EXCELLENT trial. Int J Cardiol 167:721–726CrossRef
10.
go back to reference Levine GN, Bates ER, Blankenship JC, Bailey SR, Bittl JA, Cercek B, Chambers CE, Ellis SG, Guyton RA, Hollenberg SM, Khot UN, Lange RA, Mauri L, Mehran R, Moussa ID, Mukherjee D, Nallamothu BK, Ting HH (2011) 2011 ACCF/AHA/SCAI guideline for percutaneous coronary intervention: executive summary: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Society for Cardiovascular Angiography and Interventions. Circulation 124:2574–2609CrossRef Levine GN, Bates ER, Blankenship JC, Bailey SR, Bittl JA, Cercek B, Chambers CE, Ellis SG, Guyton RA, Hollenberg SM, Khot UN, Lange RA, Mauri L, Mehran R, Moussa ID, Mukherjee D, Nallamothu BK, Ting HH (2011) 2011 ACCF/AHA/SCAI guideline for percutaneous coronary intervention: executive summary: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Society for Cardiovascular Angiography and Interventions. Circulation 124:2574–2609CrossRef
11.
go back to reference de la Torre Hernandez JM, Baz Alonso JA, Gomez Hospital JA, Alfonso Manterola F, Garcia Camarero T, Gimeno de Carlos F, Roura Ferrer G, Recalde AS, Martinez-Luengas IL, Gomez Lara J, Hernandez Hernandez F, Perez-Vizcayno MJ, Cequier Fillat A, Perez de Prado A, Gonzalez-Trevilla AA, Jimenez Navarro MF, Mauri Ferre J, Fernandez Diaz JA, Pinar Bermudez E, Zueco Gil J, IVUS-TRONCO-ICP Spanish Study (2014) Clinical impact of intravascular ultrasound guidance in drug-eluting stent implantation for unprotected left main coronary disease: pooled analysis at the patient-level of 4 registries. JACC Cardiovasc Interv 7:244–254CrossRef de la Torre Hernandez JM, Baz Alonso JA, Gomez Hospital JA, Alfonso Manterola F, Garcia Camarero T, Gimeno de Carlos F, Roura Ferrer G, Recalde AS, Martinez-Luengas IL, Gomez Lara J, Hernandez Hernandez F, Perez-Vizcayno MJ, Cequier Fillat A, Perez de Prado A, Gonzalez-Trevilla AA, Jimenez Navarro MF, Mauri Ferre J, Fernandez Diaz JA, Pinar Bermudez E, Zueco Gil J, IVUS-TRONCO-ICP Spanish Study (2014) Clinical impact of intravascular ultrasound guidance in drug-eluting stent implantation for unprotected left main coronary disease: pooled analysis at the patient-level of 4 registries. JACC Cardiovasc Interv 7:244–254CrossRef
12.
go back to reference Onuma Y, Kimura T, Raber L, Magro M, Girasis C, van Domburg R, Windecker S, Mitsudo K, Serruys PW (2015) Differences in coronary risk factors, procedural characteristics, mortality and stent thrombosis between two all-comers percutaneous coronary intervention registries from Europe and Japan: a patient-level data analysis of the Bern-Rotterdam and j-Cypher registries. EuroIntervention 11:533–540CrossRef Onuma Y, Kimura T, Raber L, Magro M, Girasis C, van Domburg R, Windecker S, Mitsudo K, Serruys PW (2015) Differences in coronary risk factors, procedural characteristics, mortality and stent thrombosis between two all-comers percutaneous coronary intervention registries from Europe and Japan: a patient-level data analysis of the Bern-Rotterdam and j-Cypher registries. EuroIntervention 11:533–540CrossRef
13.
go back to reference Lotfi A, Jeremias A, Fearon WF, Feldman MD, Mehran R, Messenger JC, Grines CL, Dean LS, Kern MJ, Klein LW, Society of Cardiovascular A, Interventions (2014) Expert consensus statement on the use of fractional flow reserve, intravascular ultrasound, and optical coherence tomography. Catheter Cardiovasc Interv 83:509–518.CrossRef Lotfi A, Jeremias A, Fearon WF, Feldman MD, Mehran R, Messenger JC, Grines CL, Dean LS, Kern MJ, Klein LW, Society of Cardiovascular A, Interventions (2014) Expert consensus statement on the use of fractional flow reserve, intravascular ultrasound, and optical coherence tomography. Catheter Cardiovasc Interv 83:509–518.CrossRef
14.
go back to reference Maluenda G, Lemesle G, Ben-Dor I, Collins SD, Syed AI, Torguson R, Kaneshige K, Xue Z, Suddath WO, Satler LF, Kent KM, Lindsay J, Pichard AD, Waksman R (2010) Impact of intravascular ultrasound guidance in patients with acute myocardial infarction undergoing percutaneous coronary intervention. Catheter Cardiovasc Interv 75:86–92PubMed Maluenda G, Lemesle G, Ben-Dor I, Collins SD, Syed AI, Torguson R, Kaneshige K, Xue Z, Suddath WO, Satler LF, Kent KM, Lindsay J, Pichard AD, Waksman R (2010) Impact of intravascular ultrasound guidance in patients with acute myocardial infarction undergoing percutaneous coronary intervention. Catheter Cardiovasc Interv 75:86–92PubMed
15.
go back to reference Nakatsuma K, Shiomi H, Morimoto T, Ando K, Kadota K, Watanabe H, Taniguchi T, Yamamoto T, Furukawa Y, Nakagawa Y, Horie M, Kimura T Investigators CR-KA (2016) Intravascular ultrasound guidance vs. angiographic guidance in primary percutaneous coronary intervention for ST-segment elevation myocardial infarction-long-term clinical outcomes from the CREDO-Kyoto AMI Registry. Circ J 80:477–484CrossRef Nakatsuma K, Shiomi H, Morimoto T, Ando K, Kadota K, Watanabe H, Taniguchi T, Yamamoto T, Furukawa Y, Nakagawa Y, Horie M, Kimura T Investigators CR-KA (2016) Intravascular ultrasound guidance vs. angiographic guidance in primary percutaneous coronary intervention for ST-segment elevation myocardial infarction-long-term clinical outcomes from the CREDO-Kyoto AMI Registry. Circ J 80:477–484CrossRef
16.
go back to reference Roe MT, Messenger JC, Weintraub WS, Cannon CP, Fonarow GC, Dai D, Chen AY, Klein LW, Masoudi FA, McKay C, Hewitt K, Brindis RG, Peterson ED, Rumsfeld JS (2010) Treatments, trends, and outcomes of acute myocardial infarction and percutaneous coronary intervention. J Am Coll Cardiol 56:254–263CrossRef Roe MT, Messenger JC, Weintraub WS, Cannon CP, Fonarow GC, Dai D, Chen AY, Klein LW, Masoudi FA, McKay C, Hewitt K, Brindis RG, Peterson ED, Rumsfeld JS (2010) Treatments, trends, and outcomes of acute myocardial infarction and percutaneous coronary intervention. J Am Coll Cardiol 56:254–263CrossRef
17.
go back to reference Anderson HV, Shaw RE, Brindis RG, McKay CR, Klein LW, Krone RJ, Ho KK, Rumsfeld JS, Smith SC Jr, Weintraub WS (2007) Risk-adjusted mortality analysis of percutaneous coronary interventions by American College of Cardiology/American Heart Association guidelines recommendations. Am J Cardiol 99:189–196CrossRef Anderson HV, Shaw RE, Brindis RG, McKay CR, Klein LW, Krone RJ, Ho KK, Rumsfeld JS, Smith SC Jr, Weintraub WS (2007) Risk-adjusted mortality analysis of percutaneous coronary interventions by American College of Cardiology/American Heart Association guidelines recommendations. Am J Cardiol 99:189–196CrossRef
18.
go back to reference Ohno Y, Maekawa Y, Miyata H, Inoue S, Ishikawa S, Sueyoshi K, Noma S, Kawamura A, Kohsaka S, Fukuda K (2013) Impact of periprocedural bleeding on incidence of contrast-induced acute kidney injury in patients treated with percutaneous coronary intervention. J Am Coll Cardiol 62:1260CrossRef Ohno Y, Maekawa Y, Miyata H, Inoue S, Ishikawa S, Sueyoshi K, Noma S, Kawamura A, Kohsaka S, Fukuda K (2013) Impact of periprocedural bleeding on incidence of contrast-induced acute kidney injury in patients treated with percutaneous coronary intervention. J Am Coll Cardiol 62:1260CrossRef
19.
go back to reference Numasawa Y, Kohsaka S, Miyata H, Kawamura A, Noma S, Suzuki M, Nakagawa S, Momiyama Y, Takahashi T, Sato Y, Fukuda K (2013) Use of thrombolysis in myocardial infarction risk score to predict bleeding complications in patients with unstable angina and non-ST elevation myocardial infarction undergoing percutaneous coronary intervention. Cardiovasc Interv Ther 28:242–249CrossRef Numasawa Y, Kohsaka S, Miyata H, Kawamura A, Noma S, Suzuki M, Nakagawa S, Momiyama Y, Takahashi T, Sato Y, Fukuda K (2013) Use of thrombolysis in myocardial infarction risk score to predict bleeding complications in patients with unstable angina and non-ST elevation myocardial infarction undergoing percutaneous coronary intervention. Cardiovasc Interv Ther 28:242–249CrossRef
20.
go back to reference Huber MS, Mooney JF, Madison J, Mooney MR (1991) Use of a morphologic classification to predict clinical outcome after dissection from coronary angioplasty. Am J Cardiol 68:467–471CrossRef Huber MS, Mooney JF, Madison J, Mooney MR (1991) Use of a morphologic classification to predict clinical outcome after dissection from coronary angioplasty. Am J Cardiol 68:467–471CrossRef
21.
go back to reference Arai T, Yuasa S, Miyata H, Kawamura A, Maekawa Y, Ishikawa S, Noma S, Inoue S, Sato Y, Kohsaka S, Fukuda K (2013) Incidence of periprocedural myocardial infarction and cardiac biomarker testing after percutaneous coronary intervention in Japan: results from a multicenter registry. Heart Vessels 28:714–719CrossRef Arai T, Yuasa S, Miyata H, Kawamura A, Maekawa Y, Ishikawa S, Noma S, Inoue S, Sato Y, Kohsaka S, Fukuda K (2013) Incidence of periprocedural myocardial infarction and cardiac biomarker testing after percutaneous coronary intervention in Japan: results from a multicenter registry. Heart Vessels 28:714–719CrossRef
22.
go back to reference Mehta SK, Frutkin AD, Lindsey JB, House JA, Spertus JA, Rao SV, Ou FS, Roe MT, Peterson ED, Marso SP, National Cardiovascular Data R (2009) Bleeding in patients undergoing percutaneous coronary intervention: the development of a clinical risk algorithm from the National Cardiovascular Data Registry. Circ Cardiovasc Interv 2:222–229CrossRef Mehta SK, Frutkin AD, Lindsey JB, House JA, Spertus JA, Rao SV, Ou FS, Roe MT, Peterson ED, Marso SP, National Cardiovascular Data R (2009) Bleeding in patients undergoing percutaneous coronary intervention: the development of a clinical risk algorithm from the National Cardiovascular Data Registry. Circ Cardiovasc Interv 2:222–229CrossRef
23.
go back to reference Mehran R, Rao SV, Bhatt DL, Gibson CM, Caixeta A, Eikelboom J, Kaul S, Wiviott SD, Menon V, Nikolsky E, Serebruany V, Valgimigli M, Vranckx P, Taggart D, Sabik JF, Cutlip DE, Krucoff MW, Ohman EM, Steg PG, White H (2011) Standardized bleeding definitions for cardiovascular clinical trials: a consensus report from the Bleeding Academic Research Consortium. Circulation 123:2736–2747CrossRef Mehran R, Rao SV, Bhatt DL, Gibson CM, Caixeta A, Eikelboom J, Kaul S, Wiviott SD, Menon V, Nikolsky E, Serebruany V, Valgimigli M, Vranckx P, Taggart D, Sabik JF, Cutlip DE, Krucoff MW, Ohman EM, Steg PG, White H (2011) Standardized bleeding definitions for cardiovascular clinical trials: a consensus report from the Bleeding Academic Research Consortium. Circulation 123:2736–2747CrossRef
24.
go back to reference Austin PC (2009) The relative ability of different propensity score methods to balance measured covariates between treated and untreated subjects in observational studies. Med Decis Mak 29:661–677CrossRef Austin PC (2009) The relative ability of different propensity score methods to balance measured covariates between treated and untreated subjects in observational studies. Med Decis Mak 29:661–677CrossRef
25.
go back to reference Hur SH, Kang SJ, Kim YH, Ahn JM, Park DW, Lee SW, Yun SC, Lee CW, Park SW, Park SJ (2013) Impact of intravascular ultrasound-guided percutaneous coronary intervention on long-term clinical outcomes in a real world population. Catheter Cardiovasc Interv 81:407–416CrossRef Hur SH, Kang SJ, Kim YH, Ahn JM, Park DW, Lee SW, Yun SC, Lee CW, Park SW, Park SJ (2013) Impact of intravascular ultrasound-guided percutaneous coronary intervention on long-term clinical outcomes in a real world population. Catheter Cardiovasc Interv 81:407–416CrossRef
26.
go back to reference Ahn JM, Han S, Park YK, Lee WS, Jang JY, Kwon CH, Park GM, Cho YR, Lee JY, Kim WJ, Park DW, Kang SJ, Lee SW, Kim YH, Lee CW, Kim JJ, Park SW, Park SJ (2013) Differential prognostic effect of intravascular ultrasound use according to implanted stent length. Am J Cardiol 111:829–835CrossRef Ahn JM, Han S, Park YK, Lee WS, Jang JY, Kwon CH, Park GM, Cho YR, Lee JY, Kim WJ, Park DW, Kang SJ, Lee SW, Kim YH, Lee CW, Kim JJ, Park SW, Park SJ (2013) Differential prognostic effect of intravascular ultrasound use according to implanted stent length. Am J Cardiol 111:829–835CrossRef
27.
go back to reference Claessen BE, Mehran R, Mintz GS, Weisz G, Leon MB, Dogan O, de Ribamar Costa Jr J, Stone GW, Apostolidou I, Morales A, Chantziara V, Syros G, Sanidas E, Xu K, Tijssen JG, Henriques JP, Piek JJ, Moses JW, Maehara A, Dangas GD (2011) Impact of intravascular ultrasound imaging on early and late clinical outcomes following percutaneous coronary intervention with drug-eluting stents. JACC Cardiovasc Interv 4:974–981CrossRef Claessen BE, Mehran R, Mintz GS, Weisz G, Leon MB, Dogan O, de Ribamar Costa Jr J, Stone GW, Apostolidou I, Morales A, Chantziara V, Syros G, Sanidas E, Xu K, Tijssen JG, Henriques JP, Piek JJ, Moses JW, Maehara A, Dangas GD (2011) Impact of intravascular ultrasound imaging on early and late clinical outcomes following percutaneous coronary intervention with drug-eluting stents. JACC Cardiovasc Interv 4:974–981CrossRef
28.
go back to reference Biondi-Zoccai G, Sheiban I, Romagnoli E, De Servi S, Tamburino C, Colombo A, Burzotta F, Presbitero P, Bolognese L, Paloscia L, Rubino P, Sardella G, Briguori C, Niccoli L, Franco G, Di Girolamo D, Piatti L, Greco C, Capodanno D, Sangiorgi G (2011) Is intravascular ultrasound beneficial for percutaneous coronary intervention of bifurcation lesions? Evidence from a 4314-patient registry. Clin Res Cardiol 100:1021–1108CrossRef Biondi-Zoccai G, Sheiban I, Romagnoli E, De Servi S, Tamburino C, Colombo A, Burzotta F, Presbitero P, Bolognese L, Paloscia L, Rubino P, Sardella G, Briguori C, Niccoli L, Franco G, Di Girolamo D, Piatti L, Greco C, Capodanno D, Sangiorgi G (2011) Is intravascular ultrasound beneficial for percutaneous coronary intervention of bifurcation lesions? Evidence from a 4314-patient registry. Clin Res Cardiol 100:1021–1108CrossRef
29.
go back to reference Zeglin-Sawczuk M, Jang IK, Kato K, Yonetsu T, Kim S, Choi SY, Kratlian C, Lee H, Dauerman HL (2013) Lipid rich plaque, female gender and proximal coronary stent edge dissections. J Thromb Thrombolysis 36:507–513CrossRef Zeglin-Sawczuk M, Jang IK, Kato K, Yonetsu T, Kim S, Choi SY, Kratlian C, Lee H, Dauerman HL (2013) Lipid rich plaque, female gender and proximal coronary stent edge dissections. J Thromb Thrombolysis 36:507–513CrossRef
30.
go back to reference Liu X, Tsujita K, Maehara A, Mintz GS, Weisz G, Dangas GD, Lansky AJ, Kreps EM, Rabbani LE, Collins M, Stone GW, Moses JW, Mehran R, Leon MB (2009) Intravascular ultrasound assessment of the incidence and predictors of edge dissections after drug-eluting stent implantation. JACC Cardiovasc Interv 2:997–1004CrossRef Liu X, Tsujita K, Maehara A, Mintz GS, Weisz G, Dangas GD, Lansky AJ, Kreps EM, Rabbani LE, Collins M, Stone GW, Moses JW, Mehran R, Leon MB (2009) Intravascular ultrasound assessment of the incidence and predictors of edge dissections after drug-eluting stent implantation. JACC Cardiovasc Interv 2:997–1004CrossRef
31.
go back to reference Choi SY, Witzenbichler B, Maehara A, Lansky AJ, Guagliumi G, Brodie B, Kellett MA Jr, Dressler O, Parise H, Mehran R, Dangas GD, Mintz GS, Stone GW (2011) Intravascular ultrasound findings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: a Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy. Circ Cardiovasc Interv 4:239–247CrossRef Choi SY, Witzenbichler B, Maehara A, Lansky AJ, Guagliumi G, Brodie B, Kellett MA Jr, Dressler O, Parise H, Mehran R, Dangas GD, Mintz GS, Stone GW (2011) Intravascular ultrasound findings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: a Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy. Circ Cardiovasc Interv 4:239–247CrossRef
32.
go back to reference Okura H, Nakamura M, Kotani J, Kozuma K, Taxus Japan Postmarket Surveillance Study Taxus-PMS Investigators (2013) Gender-specific outcome after paclitaxel-eluting stent implantation in Japanese patients with coronary artery disease—sub-analysis of the Japan TAXUS Express2 post-marketing survey. Circ J 77:1430–1435CrossRef Okura H, Nakamura M, Kotani J, Kozuma K, Taxus Japan Postmarket Surveillance Study Taxus-PMS Investigators (2013) Gender-specific outcome after paclitaxel-eluting stent implantation in Japanese patients with coronary artery disease—sub-analysis of the Japan TAXUS Express2 post-marketing survey. Circ J 77:1430–1435CrossRef
33.
go back to reference Radke PW, Friese K, Buhr A, Nagel B, Harland LC, Kaiser A, Remmel M, Hanrath P, Schunkert H, Hoffmann R (2006) Comparison of coronary restenosis rates in matched patients with versus without diabetes mellitus. Am J Cardiol 98:1218–1222CrossRef Radke PW, Friese K, Buhr A, Nagel B, Harland LC, Kaiser A, Remmel M, Hanrath P, Schunkert H, Hoffmann R (2006) Comparison of coronary restenosis rates in matched patients with versus without diabetes mellitus. Am J Cardiol 98:1218–1222CrossRef
34.
35.
go back to reference Kohsaka S, Miyata H, Ueda I, Masoudi FA, Peterson ED, Maekawa Y, Kawamura A, Fukuda K, Roe MT, Rumsfeld JS, KiCS JCD, Ncdr (2015) An international comparison of patients undergoing percutaneous coronary intervention: a collaborative study of the National Cardiovascular Data Registry (NCDR) and Japan Cardiovascular Database-Keio interhospital Cardiovascular Studies (JCD-KiCS). Am Heart J 170:1077–1085CrossRef Kohsaka S, Miyata H, Ueda I, Masoudi FA, Peterson ED, Maekawa Y, Kawamura A, Fukuda K, Roe MT, Rumsfeld JS, KiCS JCD, Ncdr (2015) An international comparison of patients undergoing percutaneous coronary intervention: a collaborative study of the National Cardiovascular Data Registry (NCDR) and Japan Cardiovascular Database-Keio interhospital Cardiovascular Studies (JCD-KiCS). Am Heart J 170:1077–1085CrossRef
36.
go back to reference Hernandez I, Baik SH, Pinera A, Zhang Y (2015) Risk of bleeding with dabigatran in atrial fibrillation. JAMA Intern Med 175:18–24CrossRef Hernandez I, Baik SH, Pinera A, Zhang Y (2015) Risk of bleeding with dabigatran in atrial fibrillation. JAMA Intern Med 175:18–24CrossRef
37.
go back to reference Kim JS, Kang TS, Mintz GS, Park BE, Shin DH, Kim BK, Ko YG, Choi D, Jang Y, Hong MK (2013) Randomized comparison of clinical outcomes between intravascular ultrasound and angiography-guided drug-eluting stent implantation for long coronary artery stenoses. JACC Cardiovasc Interv 6:369–376CrossRef Kim JS, Kang TS, Mintz GS, Park BE, Shin DH, Kim BK, Ko YG, Choi D, Jang Y, Hong MK (2013) Randomized comparison of clinical outcomes between intravascular ultrasound and angiography-guided drug-eluting stent implantation for long coronary artery stenoses. JACC Cardiovasc Interv 6:369–376CrossRef
38.
go back to reference Cho S, Shin DH, Kim JS, Kim BK, Ko YG, Choi D, Jang Y, Hong MK (2015) Rationale and design: impact of intravascular ultrasound guidance on long-term clinical outcomes of everolimus-eluting stents in long coronary lesions. Contemp Clin Trials 40:90–94CrossRef Cho S, Shin DH, Kim JS, Kim BK, Ko YG, Choi D, Jang Y, Hong MK (2015) Rationale and design: impact of intravascular ultrasound guidance on long-term clinical outcomes of everolimus-eluting stents in long coronary lesions. Contemp Clin Trials 40:90–94CrossRef
39.
go back to reference Gaster AL, Slothuus Skjoldborg U, Larsen J, Korsholm L, von Birgelen C, Jensen S, Thayssen P, Pedersen KE, Haghfelt TH (2003) Continued improvement of clinical outcome and cost effectiveness following intravascular ultrasound guided PCI: insights from a prospective, randomised study. Heart 89:1043–1049CrossRef Gaster AL, Slothuus Skjoldborg U, Larsen J, Korsholm L, von Birgelen C, Jensen S, Thayssen P, Pedersen KE, Haghfelt TH (2003) Continued improvement of clinical outcome and cost effectiveness following intravascular ultrasound guided PCI: insights from a prospective, randomised study. Heart 89:1043–1049CrossRef
Metadata
Title
Real-world use of intravascular ultrasound in Japan: a report from contemporary multicenter PCI registry
Authors
Toshiki Kuno
Yohei Numasawa
Mitsuaki Sawano
Takayuki Abe
Ikuko Ueda
Masaki Kodaira
Masahiro Suzuki
Shigetaka Noma
Iwao Nakamura
Koji Negishi
Shiro Ishikawa
Keiichi Fukuda
Shun Kohsaka
Publication date
01-11-2019
Publisher
Springer Japan
Published in
Heart and Vessels / Issue 11/2019
Print ISSN: 0910-8327
Electronic ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-019-01427-9

Other articles of this Issue 11/2019

Heart and Vessels 11/2019 Go to the issue