Skip to main content
Top
Published in: Heart and Vessels 7/2017

01-07-2017 | Original Article

Comparison of 8-frame and 16-frame thallium-201 gated myocardial perfusion SPECT for determining left ventricular systolic and diastolic parameters

Authors: Satoshi Kurisu, Yoji Sumimoto, Hiroki Ikenaga, Noriaki Watanabe, Ken Ishibashi, Yoshihiro Dohi, Yukihiro Fukuda, Yasuki Kihara

Published in: Heart and Vessels | Issue 7/2017

Login to get access

Abstract

The myocardial perfusion single photon emission computed tomography synchronized with the electrocardiogram (gated SPECT) has been widely used for the assessment of left ventricular (LV) systolic and diastolic functions using Quantitative gated SPECT. The aim of this study was to compare the effects of 8-frame and 16-frame thallium-201 (Tl-201) gated SPECT for determining LV systolic and diastolic parameters. The study population included 42 patients with suspected coronary artery disease who underwent gated SPECT by clinical indication. LV systolic and diastolic parameters were assessed on 8-frame and 16-frame gated SPECT. There were good correlations in end-diastolic volume (r = 0.99, p < 0.001), end-systolic volume (ESV) (r = 0.97, p < 0.001) and ejection fraction (EF) (r = 0.95, p < 0.001) between 8-frame and 16-frame gated SPECT. Bland–Altman plot showed a significant negative slope of −0.08 in EDV indicating a larger difference for larger EDV. Eight-frame gated SPECT overestimated ESV by 2.3 ml, and underestimated EF by −4.2% than 16-frame gated SPECT. There were good correlations in peak filling rate (PFR) (r = 0.87, p < 0.001), one third mean filling rate (r = 0.87, p < 0.001) and time to PFR (r = 0.61, p < 0.001) between 8-frame and 16-frame gated SPECT. Eight-frame gated SPECT underestimated PFR by −0.22 than 16-frame gated SPECT. Eight-frame gated SPECT estimated as much MFR/3 and TPFR as 16-frame gated SPECT. According to the data, the study suggested that 8-frame Tl-201 gated SPECT could underestimate systolic and/or diastolic parameter when compared with 16-frame gated SPECT.
Literature
1.
go back to reference Germano G, Kiat H, Kavanagh PB, Moriel M, Mazzanti M, Su HT, Van Train KF, Berman DS (1995) Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 36:2138–2147PubMed Germano G, Kiat H, Kavanagh PB, Moriel M, Mazzanti M, Su HT, Van Train KF, Berman DS (1995) Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 36:2138–2147PubMed
2.
go back to reference Cwajg E, Cwajg J, He ZX, Hwang WS, Keng F, Nagueh SF, Verani MS (1999) Gated myocardial perfusion tomography for the assessment of left ventricular function and volumes: comparison with echocardiography. J Nucl Med 40:1857–1865PubMed Cwajg E, Cwajg J, He ZX, Hwang WS, Keng F, Nagueh SF, Verani MS (1999) Gated myocardial perfusion tomography for the assessment of left ventricular function and volumes: comparison with echocardiography. J Nucl Med 40:1857–1865PubMed
3.
go back to reference Patel CD, Nadig MR, Kurien S, Barai S, Narang R, Malhotra A (2006) Left ventricular ejection fraction and volumes on rest gated 201Tl perfusion SPECT: comparison with two-dimensional echocardiography. Nucl Med Commun 27:425–429CrossRefPubMed Patel CD, Nadig MR, Kurien S, Barai S, Narang R, Malhotra A (2006) Left ventricular ejection fraction and volumes on rest gated 201Tl perfusion SPECT: comparison with two-dimensional echocardiography. Nucl Med Commun 27:425–429CrossRefPubMed
4.
go back to reference Kurisu S, Iwasaki T, Ikenaga H, Watanabe N, Higaki T, Shimonaga T, Ishibashi K, Mitsuba N, Dohi Y, Kihara Y (2014) Influence of left ventricular geometry on thallium-201 gated single-photon emission tomographic findings in patients with known or suspected coronary artery disease. Ann Nucl Med 28:120–127CrossRefPubMed Kurisu S, Iwasaki T, Ikenaga H, Watanabe N, Higaki T, Shimonaga T, Ishibashi K, Mitsuba N, Dohi Y, Kihara Y (2014) Influence of left ventricular geometry on thallium-201 gated single-photon emission tomographic findings in patients with known or suspected coronary artery disease. Ann Nucl Med 28:120–127CrossRefPubMed
5.
go back to reference Navare SM, Wackers FJ, Liu YH (2003) Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction. Eur J Nucl Med Mol Imaging 30:1330–1337CrossRefPubMed Navare SM, Wackers FJ, Liu YH (2003) Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction. Eur J Nucl Med Mol Imaging 30:1330–1337CrossRefPubMed
6.
go back to reference Montelatici G, Sciagrà R, Passeri A, Dona M, Pupi A (2008) Is 16-frame really superior to 8-frame gated SPECT for the assessment of left ventricular volumes and ejection fraction? Comparison of two simultaneously acquired gated SPECT studies. Eur J Nucl Med Mol Imaging 35:2059–2065CrossRefPubMed Montelatici G, Sciagrà R, Passeri A, Dona M, Pupi A (2008) Is 16-frame really superior to 8-frame gated SPECT for the assessment of left ventricular volumes and ejection fraction? Comparison of two simultaneously acquired gated SPECT studies. Eur J Nucl Med Mol Imaging 35:2059–2065CrossRefPubMed
7.
go back to reference DePuey EG, Parmett S, Ghesani M, Rozanski A, Nichols K, Salensky H (1999) Comparison of Tc-99m sestamibi and Tl-201 gated perfusion SPECT. J Nucl Cardiol 6:278–285CrossRefPubMed DePuey EG, Parmett S, Ghesani M, Rozanski A, Nichols K, Salensky H (1999) Comparison of Tc-99m sestamibi and Tl-201 gated perfusion SPECT. J Nucl Cardiol 6:278–285CrossRefPubMed
8.
go back to reference Kurisu S, Iwasaki T, Abe N, Tamura M, Ikenaga H, Watanabe N, Higaki T, Shimonaga T, Ishibashi K, Dohi Y, Fukuda Y, Kihara Y (2015) Effects of myocardial perfusion abnormalities on the accuracy of left ventricular volume and ejection fraction measured by thallium-201 gated single-photon emission tomography: comparison with echocardiography as the reference standard. Nucl Med Commun 36:1127–1133CrossRefPubMed Kurisu S, Iwasaki T, Abe N, Tamura M, Ikenaga H, Watanabe N, Higaki T, Shimonaga T, Ishibashi K, Dohi Y, Fukuda Y, Kihara Y (2015) Effects of myocardial perfusion abnormalities on the accuracy of left ventricular volume and ejection fraction measured by thallium-201 gated single-photon emission tomography: comparison with echocardiography as the reference standard. Nucl Med Commun 36:1127–1133CrossRefPubMed
9.
go back to reference Kurisu S, Iwasaki T, Ikenaga H, Watanabe N, Higaki T, Shimonaga T, Ishibashi K, Dohi Y, Hidaka T, Fukuda Y, Kihara Y (2016) Association of mitral annular velocity with myocardial ischemia assessed by single-photon emission computed tomography in patients with suspected coronary artery disease and preserved ejection fraction. Nucl Med Commun 37:278–282PubMed Kurisu S, Iwasaki T, Ikenaga H, Watanabe N, Higaki T, Shimonaga T, Ishibashi K, Dohi Y, Hidaka T, Fukuda Y, Kihara Y (2016) Association of mitral annular velocity with myocardial ischemia assessed by single-photon emission computed tomography in patients with suspected coronary artery disease and preserved ejection fraction. Nucl Med Commun 37:278–282PubMed
10.
go back to reference Manrique A, Faraggi M, Véra P, Vilain D, Lebtahi R, Cribier A, Le Guludec D (1999) 201Tl and 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction: comparison with equilibrium radionuclide angiography. J Nucl Med 40:805–809PubMed Manrique A, Faraggi M, Véra P, Vilain D, Lebtahi R, Cribier A, Le Guludec D (1999) 201Tl and 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction: comparison with equilibrium radionuclide angiography. J Nucl Med 40:805–809PubMed
11.
go back to reference Faber TL, Vansant JP, Pettigrew RI, Galt JR, Blais M, Chatzimavroudis G, Cooke CD, Folks RD, Waldrop SM, Gurtler-Krawczynska E, Wittry MD, Garcia EV (2001) Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: comparison of two methods. J Nucl Cardiol 8:645–651CrossRefPubMed Faber TL, Vansant JP, Pettigrew RI, Galt JR, Blais M, Chatzimavroudis G, Cooke CD, Folks RD, Waldrop SM, Gurtler-Krawczynska E, Wittry MD, Garcia EV (2001) Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: comparison of two methods. J Nucl Cardiol 8:645–651CrossRefPubMed
12.
go back to reference Persson E, Carlsson M, Palmer J, Pahlm O, Arheden H (2005) Evaluation of left ventricular volumes and ejection fraction by automated gated myocardial SPECT versus cardiovascular magnetic resonance. Clin Physiol Funct Imaging 25:135–141CrossRefPubMed Persson E, Carlsson M, Palmer J, Pahlm O, Arheden H (2005) Evaluation of left ventricular volumes and ejection fraction by automated gated myocardial SPECT versus cardiovascular magnetic resonance. Clin Physiol Funct Imaging 25:135–141CrossRefPubMed
13.
go back to reference Kumita S, Cho K, Nakajo H, Toba M, Uwamori M, Mizumura S, Kumazaki T, Sano J, Sakai S, Munakata K (2001) Assessment of left ventricular diastolic function with electrocardiography-gated myocardial perfusion SPECT: comparison with multigated equilibrium radionuclide angiography. J Nucl Cardiol 8:568–574CrossRefPubMed Kumita S, Cho K, Nakajo H, Toba M, Uwamori M, Mizumura S, Kumazaki T, Sano J, Sakai S, Munakata K (2001) Assessment of left ventricular diastolic function with electrocardiography-gated myocardial perfusion SPECT: comparison with multigated equilibrium radionuclide angiography. J Nucl Cardiol 8:568–574CrossRefPubMed
14.
go back to reference Takeuchi T, Tomita T, Yoshie K, Hioki H, Oguchi Y, Miura T, Ebisawa S, Motoki H, Okada A, Aizawa K, Izawa A, Miyashita Y, Koyama J, Ikeda U (2015) Electrocardiographic J waves are associated with right ventricular morphology and function: evaluation by cardiac magnetic resonance imaging. Heart Vessels 30:98–107CrossRefPubMed Takeuchi T, Tomita T, Yoshie K, Hioki H, Oguchi Y, Miura T, Ebisawa S, Motoki H, Okada A, Aizawa K, Izawa A, Miyashita Y, Koyama J, Ikeda U (2015) Electrocardiographic J waves are associated with right ventricular morphology and function: evaluation by cardiac magnetic resonance imaging. Heart Vessels 30:98–107CrossRefPubMed
15.
go back to reference Nozue T, Yamada M, Tsunoda T, Katoh H, Ito S, Iwaki T, Michishita I (2016) Effects of liraglutide, a glucagon-like peptide-1 analog, on left ventricular remodeling assessed by cardiac magnetic resonance imaging in patients with acute myocardial infarction undergoing primary percutaneous coronary intervention. Heart Vessels 31:1239–1246CrossRefPubMed Nozue T, Yamada M, Tsunoda T, Katoh H, Ito S, Iwaki T, Michishita I (2016) Effects of liraglutide, a glucagon-like peptide-1 analog, on left ventricular remodeling assessed by cardiac magnetic resonance imaging in patients with acute myocardial infarction undergoing primary percutaneous coronary intervention. Heart Vessels 31:1239–1246CrossRefPubMed
Metadata
Title
Comparison of 8-frame and 16-frame thallium-201 gated myocardial perfusion SPECT for determining left ventricular systolic and diastolic parameters
Authors
Satoshi Kurisu
Yoji Sumimoto
Hiroki Ikenaga
Noriaki Watanabe
Ken Ishibashi
Yoshihiro Dohi
Yukihiro Fukuda
Yasuki Kihara
Publication date
01-07-2017
Publisher
Springer Japan
Published in
Heart and Vessels / Issue 7/2017
Print ISSN: 0910-8327
Electronic ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-016-0935-6

Other articles of this Issue 7/2017

Heart and Vessels 7/2017 Go to the issue