Low-dose CT angiography using ASiR-V for potential living renal donors: a prospective analysis of image quality and diagnostic accuracy

Authors: Woong Kyu Han, Joon Chae Na, Sung Yoon Park

Published in: European Radiology | Issue 2/2020

Login to get access

Abstract

Purpose

To assess image quality and diagnostic accuracy of low-dose computed tomography (CT) angiography using adaptive statistical iterative reconstruction V (ASiR-V) for evaluating the anatomy of renal vasculature in potential living renal donors.

Materials and methods

Eighty of 100 potential living renal donors were prospectively enrolled and underwent multiphase CT angiography (e.g., unenhanced, arterial, and venous phases) to evaluate the kidney for donation. Either low-dose using ASiR-V or standard protocol was randomly applied. Image quality was analyzed qualitatively and quantitatively with contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). Renal artery and vein number, early branching vessel from renal arteries, and drainage of left-sided ascending lumbar vein to left renal vein were assessed. Reference standard for renal vasculature was surgical confirmation.

Results

Size-specific dose estimate of low-dose CT angiography (9.5 ± 0.8 mGy) was significantly lower than standard CT angiography (22.7 ± 4.1 mGy) (p < 0.001). Thus, radiation dose was reduced by 58.2% with low-dose CT. Both CNR and SNR of low-dose CT were significantly higher than those of standard CT (p < 0.001). Between the two CT methods, image quality was similar qualitatively (p > 0.05). Of 80 participants, 44 (55.0%) underwent nephrectomy. Both CT methods accurately predicted the anatomy of renal vasculature (standard CT, 100% for all variables; low-dose CT, 96.6% for renal vessel number or early branching vessel and 85.7% for drainage of left-sided ascending lumbar vein to left renal vein; p > 0.05 for all comparisons).

Conclusion

Low-dose CT angiography using ASiR-V is useful to evaluate renal vasculature for potential living renal donors.

Key Points

• In this prospective study, adaptive statistical iterative reconstruction V (ASiR-V) allowed 58.2% dose reduction while maintaining diagnostic image quality for renal vessels.
• As compared with the standard protocol, the dose with ASiR-V was significantly lower (9.5 ± 0.8 mGy) than with standard computed tomography (CT) angiography (22.7 ± 4.1 mGy).
• Low-dose CT using ASiR-V is useful for living donor evaluation before nephrectomy.
Appendix
Available only for authorised users
Literature
1.
go back to reference Lentine KL, Kasiske BL, Levey AS et al (2017) KDIGO clinical practice guideline on the evaluation and care of living kidney donors. Transplantation 101:S1–S109PubMed Lentine KL, Kasiske BL, Levey AS et al (2017) KDIGO clinical practice guideline on the evaluation and care of living kidney donors. Transplantation 101:S1–S109PubMed
2.
go back to reference Pozniak MA, Balison DJ, Lee FT Jr, Tambeaux RH, Uehling DT, Moon TD (1998) CT angiography of potential renal transplant donors. Radiographics 18:565–587CrossRef Pozniak MA, Balison DJ, Lee FT Jr, Tambeaux RH, Uehling DT, Moon TD (1998) CT angiography of potential renal transplant donors. Radiographics 18:565–587CrossRef
3.
go back to reference Chai JW, Lee W, Yin YH et al (2008) CT angiography for living kidney donors: accuracy, cause of misinterpretation and prevalence of variation. Korean J Radiol 9:333–339CrossRef Chai JW, Lee W, Yin YH et al (2008) CT angiography for living kidney donors: accuracy, cause of misinterpretation and prevalence of variation. Korean J Radiol 9:333–339CrossRef
4.
go back to reference Kawamoto S, Montgomery RA, Lawler LP, Horton KM, Fishman EK (2003) Multidetector CT angiography for preoperative evaluation of living laparoscopic kidney donors. AJR Am J Roentgenol 180:1633–1638CrossRef Kawamoto S, Montgomery RA, Lawler LP, Horton KM, Fishman EK (2003) Multidetector CT angiography for preoperative evaluation of living laparoscopic kidney donors. AJR Am J Roentgenol 180:1633–1638CrossRef
5.
go back to reference Sebastia C, Peri L, Salvador R et al (2010) Multidetector CT of living renal donors: lessons learned from surgeons. Radiographics 30:1875–1890CrossRef Sebastia C, Peri L, Salvador R et al (2010) Multidetector CT of living renal donors: lessons learned from surgeons. Radiographics 30:1875–1890CrossRef
6.
go back to reference Raman SP, Mahesh M, Blasko RV, Fishman EK (2013) CT scan parameters and radiation dose: practical advice for radiologists. J Am Coll Radiol 10:840–846CrossRef Raman SP, Mahesh M, Blasko RV, Fishman EK (2013) CT scan parameters and radiation dose: practical advice for radiologists. J Am Coll Radiol 10:840–846CrossRef
7.
go back to reference Kwon H, Cho J, Oh J et al (2015) The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique. Br J Radiol 88:20150463CrossRef Kwon H, Cho J, Oh J et al (2015) The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique. Br J Radiol 88:20150463CrossRef
8.
go back to reference Fan J, Yue M, Melnyk (2014) Benefits of ASiR-V reconstruction for reducing patient radiation dose and preserving diagnostic quality in CT exams. GE white paper:1–8 Fan J, Yue M, Melnyk (2014) Benefits of ASiR-V reconstruction for reducing patient radiation dose and preserving diagnostic quality in CT exams. GE white paper:1–8
9.
go back to reference Euler A, Solomon J, Marin D, Nelson RC, Samei E (2018) A third-generation adaptive statistical iterative reconstruction technique: phantom study of image noise, spatial resolution, lesion detectability, and dose reduction potential. AJR Am J Roentgenol 210:1301–1308CrossRef Euler A, Solomon J, Marin D, Nelson RC, Samei E (2018) A third-generation adaptive statistical iterative reconstruction technique: phantom study of image noise, spatial resolution, lesion detectability, and dose reduction potential. AJR Am J Roentgenol 210:1301–1308CrossRef
10.
go back to reference Kim HG, Lee HJ, Lee SK, Kim HJ, Kim MJ (2017) Head CT: image quality improvement with ASIR-V using a reduced radiation dose protocol for children. Eur Radiol 27:3609–3617CrossRef Kim HG, Lee HJ, Lee SK, Kim HJ, Kim MJ (2017) Head CT: image quality improvement with ASIR-V using a reduced radiation dose protocol for children. Eur Radiol 27:3609–3617CrossRef
11.
go back to reference Gatti M, Marchisio F, Fronda M et al (2018) Adaptive statistical iterative reconstruction-V versus adaptive statistical iterative reconstruction: impact on dose reduction and image quality in body computed tomography. J Comput Assist Tomogr 42:191–196PubMed Gatti M, Marchisio F, Fronda M et al (2018) Adaptive statistical iterative reconstruction-V versus adaptive statistical iterative reconstruction: impact on dose reduction and image quality in body computed tomography. J Comput Assist Tomogr 42:191–196PubMed
12.
go back to reference Chen LH, Jin C, Li JY et al (2018) Image quality comparison of two adaptive statistical iterative reconstruction (ASiR, ASiR-V) algorithms and filtered back projection in routine liver CT. Br J Radiol 91:20170655CrossRef Chen LH, Jin C, Li JY et al (2018) Image quality comparison of two adaptive statistical iterative reconstruction (ASiR, ASiR-V) algorithms and filtered back projection in routine liver CT. Br J Radiol 91:20170655CrossRef
13.
go back to reference Rothmann MD, Wiens BL, Chan ISF (2008) Design and analysis of non-inferiority trials. CRC Press, pp 268–271 Rothmann MD, Wiens BL, Chan ISF (2008) Design and analysis of non-inferiority trials. CRC Press, pp 268–271
14.
go back to reference Alkadhi H, Schindera ST (2011) State of the art low-dose CT angiography of the body. Eur J Radiol 80:36–40CrossRef Alkadhi H, Schindera ST (2011) State of the art low-dose CT angiography of the body. Eur J Radiol 80:36–40CrossRef
15.
go back to reference Schindera ST, Graca P, Patak MA et al (2009) Thoracoabdominal-aortoiliac multidetector-row CT angiography at 80 and 100 kVp: assessment of image quality and radiation dose. Invest Radiol 44:650–655CrossRef Schindera ST, Graca P, Patak MA et al (2009) Thoracoabdominal-aortoiliac multidetector-row CT angiography at 80 and 100 kVp: assessment of image quality and radiation dose. Invest Radiol 44:650–655CrossRef
16.
go back to reference Utsunomiya D, Oda S, Funama Y et al (2010) Comparison of standard- and low-tube voltage MDCT angiography in patients with peripheral arterial disease. Eur Radiol 20:2758–2765CrossRef Utsunomiya D, Oda S, Funama Y et al (2010) Comparison of standard- and low-tube voltage MDCT angiography in patients with peripheral arterial disease. Eur Radiol 20:2758–2765CrossRef
18.
go back to reference Davarpanah AH, Pahade JK, Cornfeld D, Ghita M, Kulkarni S, Israel GM (2013) CT angiography in potential living kidney donors: 80 kVp versus 120 kVp. AJR Am J Roentgenol 201:W753–W760CrossRef Davarpanah AH, Pahade JK, Cornfeld D, Ghita M, Kulkarni S, Israel GM (2013) CT angiography in potential living kidney donors: 80 kVp versus 120 kVp. AJR Am J Roentgenol 201:W753–W760CrossRef
19.
go back to reference Raman SS, Pojchamarnwiputh S, Muangsomboon K, Schulam PG, Gritsch HA, Lu DS (2007) Surgically relevant normal and variant renal parenchymal and vascular anatomy in preoperative 16-MDCT evaluation of potential laparoscopic renal donors. AJR Am J Roentgenol 188:105–114CrossRef Raman SS, Pojchamarnwiputh S, Muangsomboon K, Schulam PG, Gritsch HA, Lu DS (2007) Surgically relevant normal and variant renal parenchymal and vascular anatomy in preoperative 16-MDCT evaluation of potential laparoscopic renal donors. AJR Am J Roentgenol 188:105–114CrossRef
20.
go back to reference Yao Y, Okada Y, Yamato M, Ohtomo K (2003) Communicating vein between the left renal vein and left ascending lumber vein: incidence and significance on abdominal CT. Radiat Med 21:252–257PubMed Yao Y, Okada Y, Yamato M, Ohtomo K (2003) Communicating vein between the left renal vein and left ascending lumber vein: incidence and significance on abdominal CT. Radiat Med 21:252–257PubMed
21.
go back to reference Kawamoto S, Lawler LP, Fishman EK (2005) Evaluation of the renal venous system on late arterial and venous phase images with MDCT angiography in potential living laparoscopic renal donors. AJR Am J Roentgenol 184:539–545CrossRef Kawamoto S, Lawler LP, Fishman EK (2005) Evaluation of the renal venous system on late arterial and venous phase images with MDCT angiography in potential living laparoscopic renal donors. AJR Am J Roentgenol 184:539–545CrossRef
22.
go back to reference Arevalo Perez J, Gragera Torres F, Marin Toribio A, Koren Fernandez L, Hayoun C, Daimiel Naranjo I (2013) Angio CT assessment of anatomical variants in renal vasculature: its importance in the living donor. Insights Imaging 4:199–211CrossRef Arevalo Perez J, Gragera Torres F, Marin Toribio A, Koren Fernandez L, Hayoun C, Daimiel Naranjo I (2013) Angio CT assessment of anatomical variants in renal vasculature: its importance in the living donor. Insights Imaging 4:199–211CrossRef
23.
go back to reference Lim K, Kwon H, Cho J et al (2015) Initial phantom study comparing image quality in computed tomography using adaptive statistical iterative reconstruction and new adaptive statistical iterative reconstruction v. J Comput Assist Tomogr 39:443–448PubMed Lim K, Kwon H, Cho J et al (2015) Initial phantom study comparing image quality in computed tomography using adaptive statistical iterative reconstruction and new adaptive statistical iterative reconstruction v. J Comput Assist Tomogr 39:443–448PubMed
24.
go back to reference Tang H, Yu N, Jia Y et al (2018) Assessment of noise reduction potential and image quality improvement of a new generation adaptive statistical iterative reconstruction (ASIR-V) in chest CT. Br J Radiol 91:20170521CrossRef Tang H, Yu N, Jia Y et al (2018) Assessment of noise reduction potential and image quality improvement of a new generation adaptive statistical iterative reconstruction (ASIR-V) in chest CT. Br J Radiol 91:20170521CrossRef
25.
go back to reference Chen Y, Wang Q, Li J, Jia Y, Yang Q, He T (2018) Triple-rule-out CT angiography using two axial scans with 16 cm wide-detector for radiation dose reduction. Eur Radiol 28:4654–4661CrossRef Chen Y, Wang Q, Li J, Jia Y, Yang Q, He T (2018) Triple-rule-out CT angiography using two axial scans with 16 cm wide-detector for radiation dose reduction. Eur Radiol 28:4654–4661CrossRef
26.
go back to reference Chen Y, Liu Z, Li M et al (2019) Reducing both radiation and contrast doses in coronary CT angiography in lean patients on a 16-cm wide-detector CT using 70 kVp and ASiR-V algorithm, in comparison with the conventional 100-kVp protocol. Eur Radiol 29:3036–3043CrossRef Chen Y, Liu Z, Li M et al (2019) Reducing both radiation and contrast doses in coronary CT angiography in lean patients on a 16-cm wide-detector CT using 70 kVp and ASiR-V algorithm, in comparison with the conventional 100-kVp protocol. Eur Radiol 29:3036–3043CrossRef
27.
go back to reference Benz DC, Grani C, Mikulicic F et al (2016) Adaptive statistical iterative reconstruction-V: impact on image quality in ultralow-dose coronary computed tomography angiography. J Comput Assist Tomogr 40:958–963CrossRef Benz DC, Grani C, Mikulicic F et al (2016) Adaptive statistical iterative reconstruction-V: impact on image quality in ultralow-dose coronary computed tomography angiography. J Comput Assist Tomogr 40:958–963CrossRef
28.
go back to reference Chen CW, Chen PA, Chou CC et al (2019) Combination of adaptive statistical iterative reconstruction-V and lower tube voltage during craniocervical computed tomographic angiography yields better image quality with a reduced radiation dose. Acad Radiol 26:e233–e240CrossRef Chen CW, Chen PA, Chou CC et al (2019) Combination of adaptive statistical iterative reconstruction-V and lower tube voltage during craniocervical computed tomographic angiography yields better image quality with a reduced radiation dose. Acad Radiol 26:e233–e240CrossRef
30.
go back to reference Klatte T, Ficarra V, Gratzke C et al (2015) A literature review of renal surgical anatomy and surgical strategies for partial nephrectomy. Eur Urol 68:980–992CrossRef Klatte T, Ficarra V, Gratzke C et al (2015) A literature review of renal surgical anatomy and surgical strategies for partial nephrectomy. Eur Urol 68:980–992CrossRef
31.
go back to reference Liang J, Wang H, Xu L et al (2017) Diagnostic performance of 256-row detector coronary CT angiography in patients with high heart rates within a single cardiac cycle: a preliminary study. Clin Radiol 72:694 e697–694 e614CrossRef Liang J, Wang H, Xu L et al (2017) Diagnostic performance of 256-row detector coronary CT angiography in patients with high heart rates within a single cardiac cycle: a preliminary study. Clin Radiol 72:694 e697–694 e614CrossRef
32.
go back to reference Willemink MJ, Noel PB (2019) The evolution of image reconstruction for CT-from filtered back projection to artificial intelligence. Eur Radiol 29:2185–2195CrossRef Willemink MJ, Noel PB (2019) The evolution of image reconstruction for CT-from filtered back projection to artificial intelligence. Eur Radiol 29:2185–2195CrossRef
33.
go back to reference Laurent G, Villani N, Hossu G et al (2019) Full model-based iterative reconstruction (MBIR) in abdominal CT increases objective image quality, but decreases subjective acceptance. Eur Radiol 29:4016–4025CrossRef Laurent G, Villani N, Hossu G et al (2019) Full model-based iterative reconstruction (MBIR) in abdominal CT increases objective image quality, but decreases subjective acceptance. Eur Radiol 29:4016–4025CrossRef
35.
go back to reference Hu JC, Liu CH, Treat EG et al (2014) Determinants of laparoscopic donor nephrectomy outcomes. Eur Urol 65:659–664CrossRef Hu JC, Liu CH, Treat EG et al (2014) Determinants of laparoscopic donor nephrectomy outcomes. Eur Urol 65:659–664CrossRef
Metadata
Title
Low-dose CT angiography using ASiR-V for potential living renal donors: a prospective analysis of image quality and diagnostic accuracy
Authors
Woong Kyu Han
Joon Chae Na
Sung Yoon Park
Publication date
01-02-2020
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 2/2020
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-019-06423-1

Other articles of this Issue 2/2020

European Radiology 2/2020 Go to the issue