Skip to main content
Top
Published in: European Radiology 2/2020

01-02-2020 | Computed Tomography | Interventional

CT guidance assisted by electromagnetic navigation system for percutaneous fixation by internal cemented screws (FICS)

Authors: Benjamin Moulin, Lambros Tselikas, Thierry De Baere, Florent Varin, Abdellahi Abed, Laura Debays, Cécile Bardoulat, Antoine Hakime, Christophe Teriitehau, Fréderic Deschamps, Guillaume Gravel

Published in: European Radiology | Issue 2/2020

Login to get access

Abstract

Purpose

To evaluate electromagnetic navigation system (ENS) for percutaneous fixation by internal cemented screw (FICS) under CT guidance.

Background

FICS is a recently developed modality that consists in inserting screws, under imaging guidance, into bone through a minimal skin incision. FICS recently showed good efficacy for the palliation or prevention of pathologic fractures of the pelvic ring and femoral neck.

Materials and methods

In this single-center retrospective study, we reviewed all consecutive cancer patients treated with percutaneous FICS under ENS-assisted CT guidance for the prevention or palliation of pelvic or femoral neck fractures. The primary endpoint was technical success. Secondary endpoints were screw placement accuracy (defined by proximal deviation p, distal deviation d, and angle deviation θ), radiation dose exposure, number of CT acquisitions, duration of procedures, and complications.

Results

Mean duration of FICS procedures was 111 ± 51 min. Mean post-procedure hospitalization length was 2.1 days. Technical success was achieved in 48 cases (96%) with a total of 76 screws inserted. Mean distance p, mean distance d, and mean angle θ were respectively 8.0 ± 4.5 mm, 7.5 ± 4.4 mm, and 5.4 ± 2°. Angle θ accuracy was higher for screws with a craniocaudal angulation of less than 20° (4.4° vs 6.4°, p = 0.02). The mean number of CT acquisitions during procedures was 6.4 ± 3.0. The mean dose length product was 1524 ± 953 mGy cm and the mean dose area product was 12 ± 8 Gy cm2. Five complications occurred in 4 patients.

Conclusion

CT guidance assisted by ENS is an effective approach for percutaneous FICS.

Key Points

• ENS-assisted CT enables screw insertion in the pelvic ring and femoral neck, with a wide range of trajectories, even when a significant craniocaudal angulation is required.
• ENS-assisted CT can be used as an alternative to CBCT guidance for percutaneous fixation by internal cemented screw.
• ENS-assisted CT provides high technical success rate with excellent placement accuracy.
Appendix
Available only for authorised users
Literature
1.
go back to reference Coleman RE (2006) Clinical features of metastatic bone disease and risk of skeletal morbidity. Clin Cancer Res 12:6243s–6249sCrossRef Coleman RE (2006) Clinical features of metastatic bone disease and risk of skeletal morbidity. Clin Cancer Res 12:6243s–6249sCrossRef
2.
go back to reference Deschamps F, de Baere T, Hakime A et al (2016) Percutaneous osteosynthesis in the pelvis in cancer patients. Eur Radiol 26:1631–1639CrossRef Deschamps F, de Baere T, Hakime A et al (2016) Percutaneous osteosynthesis in the pelvis in cancer patients. Eur Radiol 26:1631–1639CrossRef
3.
go back to reference Roux C, Tselikas L, Yevich S et al (2019) Fluoroscopy and cone-beam CT-guided fixation by internal cemented screw for pathologic pelvic fractures. Radiology 290:418–425CrossRef Roux C, Tselikas L, Yevich S et al (2019) Fluoroscopy and cone-beam CT-guided fixation by internal cemented screw for pathologic pelvic fractures. Radiology 290:418–425CrossRef
4.
go back to reference Deschamps F, Farouil G, Hakime A, Teriitehau C, Barah A, de Baere T (2012) Percutaneous stabilization of impending pathological fracture of the proximal femur. Cardiovasc Intervent Radiol 35:1428–1432CrossRef Deschamps F, Farouil G, Hakime A, Teriitehau C, Barah A, de Baere T (2012) Percutaneous stabilization of impending pathological fracture of the proximal femur. Cardiovasc Intervent Radiol 35:1428–1432CrossRef
5.
go back to reference Durand P, Moreau-Gaudry A, Silvent AS et al (2017) Computer assisted electromagnetic navigation improves accuracy in computed tomography guided interventions: a prospective randomized clinical trial. PLoS One 12:e0173751CrossRef Durand P, Moreau-Gaudry A, Silvent AS et al (2017) Computer assisted electromagnetic navigation improves accuracy in computed tomography guided interventions: a prospective randomized clinical trial. PLoS One 12:e0173751CrossRef
7.
go back to reference Kanda Y (2013) Investigation of the freely available easy-to-use software “EZR” for medical statistics. Bone Marrow Transplant 48:452–458CrossRef Kanda Y (2013) Investigation of the freely available easy-to-use software “EZR” for medical statistics. Bone Marrow Transplant 48:452–458CrossRef
8.
go back to reference Santos RS, Gupta A, Ebright MI et al (2010) Electromagnetic navigation to aid radiofrequency ablation and biopsy of lung tumors. Ann Thorac Surg 89:265–268CrossRef Santos RS, Gupta A, Ebright MI et al (2010) Electromagnetic navigation to aid radiofrequency ablation and biopsy of lung tumors. Ann Thorac Surg 89:265–268CrossRef
9.
go back to reference Appelbaum L, Sosna J, Nissenbaum Y, Benshtein A, Goldberg SN (2011) Electromagnetic navigation system for CT-guided biopsy of small lesions. AJR Am J Roentgenol 196:1194–1200CrossRef Appelbaum L, Sosna J, Nissenbaum Y, Benshtein A, Goldberg SN (2011) Electromagnetic navigation system for CT-guided biopsy of small lesions. AJR Am J Roentgenol 196:1194–1200CrossRef
10.
go back to reference Cazzato RL, Koch G, Buy X et al (2016) Percutaneous image-guided screw fixation of bone lesions in cancer patients: double-centre analysis of outcomes including local evolution of the treated focus. Cardiovasc Intervent Radiol 39:1455–1463CrossRef Cazzato RL, Koch G, Buy X et al (2016) Percutaneous image-guided screw fixation of bone lesions in cancer patients: double-centre analysis of outcomes including local evolution of the treated focus. Cardiovasc Intervent Radiol 39:1455–1463CrossRef
Metadata
Title
CT guidance assisted by electromagnetic navigation system for percutaneous fixation by internal cemented screws (FICS)
Authors
Benjamin Moulin
Lambros Tselikas
Thierry De Baere
Florent Varin
Abdellahi Abed
Laura Debays
Cécile Bardoulat
Antoine Hakime
Christophe Teriitehau
Fréderic Deschamps
Guillaume Gravel
Publication date
01-02-2020
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 2/2020
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-019-06408-0

Other articles of this Issue 2/2020

European Radiology 2/2020 Go to the issue