Abstract

The value of a computer-aided detection tool (CAD) as second reader in combination with experienced and inexperienced radiologists for the diagnosis of acute pulmonary embolism (PE) was assessed prospectively. Computed tomographic angiography (CTA) scans (64 × 0.6 mm collimation; 61.4 mm/rot table feed) of 56 patients (31 women, 34–89 years, mean = 66 years) with suspected PE were analysed by two experienced (R1, R2) and two inexperienced (R3, R4) radiologists for the presence and distribution of emboli using a five-point confidence rating, and by CAD. Informed consent was obtained from all patients. Results were compared with an independent reference standard. Inter-observer agreement was calculated by kappa, confidence assessed by ROC analysis. A total of 1,116 emboli [within mediastinal (n = 72), lobar (n = 133), segmental (n = 465) and subsegmental arteries (n = 455)] were included. CAD detected 343 emboli (sensitivity = 30.74%, correct-positive rate = 6.13/patient; false-positive rate = 4.1/patient). Inter-observer agreement was good (R1, R2: κ = 0.84, 95% CI = 0.81–0.87; R3, R4: κ = 0.79, 95% CI = 0.76–0.81). Extended inter-observer agreement was higher in mediastinal and lobar than in segmental and subsegmental arteries (κ = 0.84–0.86 and κ = 0.51–0.58 for mediastinal/lobar and segmental/subsegmental arteries, respectively P < 0.05). Agreement between experienced and inexperienced readers was improved by CAD (κ = 0.60–0.62 and κ = 0.69–0.72 before and after CAD consensus, respectively P < 0.05). The experienced outperformed the inexperienced readers (Az = 0.95, 0.93, 0.89 and 0.86 for R1–4, respectively, P < 0.05). CAD significantly improved overall performances of readers 3 and 4 (Az = 0.86 for R3, R4 and Az = 0.89 for R3, R4 with CAD, P < 0.05), by enhancing sensitivities in segmental/subsegmental arteries. CAD improved experienced readers’ sensitivities in segmental/subsegmental arteries (sens. = 0.93 and 0.90 for R1, R2 before and 0.97 and 0.94 for R1, R2 after CAD consensus, P < 0.05), without significant improvement of their overall performances (P > 0.05). Particularly inexperienced readers benefit from consensus with CAD data, greatly improving detection of segmental and subsegmental emboli. This system is advocated as a second reader.
Literature
1.
go back to reference Dalen J, Alpert J (1975) Natural history of pulmonary embolism. Progr Cardiovasc Dis 17:257–270CrossRef Dalen J, Alpert J (1975) Natural history of pulmonary embolism. Progr Cardiovasc Dis 17:257–270CrossRef
2.
go back to reference The PIOPED Investigators (1990) Value of the ventilation/perfusion scan in acute pulmonary embolism. Results of the Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED). JAMA 263:2753–2759CrossRef The PIOPED Investigators (1990) Value of the ventilation/perfusion scan in acute pulmonary embolism. Results of the Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED). JAMA 263:2753–2759CrossRef
3.
4.
go back to reference Engelke C, Rummeny EJ, Marten K (2006) Pulmonary embolism at multi-detector row CT of chest: one-year survival of treated and untreated patients. Radiology 239:563–575PubMedCrossRef Engelke C, Rummeny EJ, Marten K (2006) Pulmonary embolism at multi-detector row CT of chest: one-year survival of treated and untreated patients. Radiology 239:563–575PubMedCrossRef
5.
go back to reference Stein PD, Fowler SE, Goodman LR et al (2006) Multidetector computed tomography for acute pulmonary embolism. N Engl J Med 354:2317–2327PubMedCrossRef Stein PD, Fowler SE, Goodman LR et al (2006) Multidetector computed tomography for acute pulmonary embolism. N Engl J Med 354:2317–2327PubMedCrossRef
6.
go back to reference Remy-Jardin M, Remy J, Wattinne L, Giraud F (1992) Central pulmonary thromboembolism diagnosis with spiral volumetric CT with the single-breath-hold technique-comparison with pulmonary angiography. Radiology 185:381–387PubMed Remy-Jardin M, Remy J, Wattinne L, Giraud F (1992) Central pulmonary thromboembolism diagnosis with spiral volumetric CT with the single-breath-hold technique-comparison with pulmonary angiography. Radiology 185:381–387PubMed
7.
go back to reference McCollough C, Zink F (1999) Performance evaluation of a multi-slice CT system. Med Phys 26:2223–2230PubMedCrossRef McCollough C, Zink F (1999) Performance evaluation of a multi-slice CT system. Med Phys 26:2223–2230PubMedCrossRef
8.
go back to reference Rubin GD, Paik DS, Johnston PC, Napel S (1998) Measurements of the aorta and its branches with helical CT. Radiology 206:823–829PubMed Rubin GD, Paik DS, Johnston PC, Napel S (1998) Measurements of the aorta and its branches with helical CT. Radiology 206:823–829PubMed
9.
go back to reference Stein PD (1999) Reassessment of pulmonary angiography for the diagnosis of pulmonary embolism: relation of interpreter agreement to the order of the involved pulmonary arterial branch. Radiology 210:689–691PubMed Stein PD (1999) Reassessment of pulmonary angiography for the diagnosis of pulmonary embolism: relation of interpreter agreement to the order of the involved pulmonary arterial branch. Radiology 210:689–691PubMed
10.
go back to reference Ghaye B, Szapiro D, Mastora I et al (2001) Peripheral pulmonary arteries: how far in the lung does multi-detector row spiral CT allow analysis? Radiology 219:629–636PubMed Ghaye B, Szapiro D, Mastora I et al (2001) Peripheral pulmonary arteries: how far in the lung does multi-detector row spiral CT allow analysis? Radiology 219:629–636PubMed
11.
go back to reference Raptopoulos V, Boiselle P (2001) Multi-detector row spiral CT pulmonary angiography comparison with single-detector row spiral CT. Radiology 221:606–613PubMedCrossRef Raptopoulos V, Boiselle P (2001) Multi-detector row spiral CT pulmonary angiography comparison with single-detector row spiral CT. Radiology 221:606–613PubMedCrossRef
12.
go back to reference Schoepf U, Holzknecht M, Helmberger TK et al (2002) Subsegmental pulmonary emboli improved detection with thin-collimation multi-detector row spiral CT. Radiology 222:482–490CrossRef Schoepf U, Holzknecht M, Helmberger TK et al (2002) Subsegmental pulmonary emboli improved detection with thin-collimation multi-detector row spiral CT. Radiology 222:482–490CrossRef
13.
go back to reference Diffin D, Leyendecker J, Johnson S et al (1998) Effect of anatomic distribution of pulmonary emboli on interobserver agreement in the interpretation of pulmonary angiography, AJR Am J Roentgenol 171:1085–1089PubMed Diffin D, Leyendecker J, Johnson S et al (1998) Effect of anatomic distribution of pulmonary emboli on interobserver agreement in the interpretation of pulmonary angiography, AJR Am J Roentgenol 171:1085–1089PubMed
14.
go back to reference Mayo J, Remy-Jardin M, Muller N (1997) Pulmonary embolism: prospective comparison of spiral CT with ventilation perfusion scintigraphy. Radiology 205:447–452PubMed Mayo J, Remy-Jardin M, Muller N (1997) Pulmonary embolism: prospective comparison of spiral CT with ventilation perfusion scintigraphy. Radiology 205:447–452PubMed
15.
go back to reference Qanadli S, Hajjam ME, Mesurille B (2000) Pulmonary embolism detection: prospective evaluation of dual-section helical CT versus selective pulmonary arteriography in 157 patients. Radiology 217:447–455PubMed Qanadli S, Hajjam ME, Mesurille B (2000) Pulmonary embolism detection: prospective evaluation of dual-section helical CT versus selective pulmonary arteriography in 157 patients. Radiology 217:447–455PubMed
16.
go back to reference Goodman LR, Curtin J, Mewissen M (1995) Detection of pulmonary embolism in patients with unsolved clinical and scintigraphic diagnosis. Helical CT versus angiography. AJR Am J Roentgenol 164:1369–1374PubMed Goodman LR, Curtin J, Mewissen M (1995) Detection of pulmonary embolism in patients with unsolved clinical and scintigraphic diagnosis. Helical CT versus angiography. AJR Am J Roentgenol 164:1369–1374PubMed
17.
go back to reference Senac J, Verhnet H, Bousquet C (1995) Embolie pulmonaire: apport de la tomodensitometrie helicoidale. J Radiol 76:339–345PubMed Senac J, Verhnet H, Bousquet C (1995) Embolie pulmonaire: apport de la tomodensitometrie helicoidale. J Radiol 76:339–345PubMed
18.
go back to reference van Rossum AB, Pattynama PM, Ton ER, Treurniet FE, Arndt JW, van Eck B, Kieft GJ (1996) Pulmonary embolism Validation of spiral CT angiography in 149 patients. Radiology 201:467–470PubMed van Rossum AB, Pattynama PM, Ton ER, Treurniet FE, Arndt JW, van Eck B, Kieft GJ (1996) Pulmonary embolism Validation of spiral CT angiography in 149 patients. Radiology 201:467–470PubMed
19.
go back to reference Remy-Jardin M, Remy J, Petyt L, Duhamel A (1996). Diagnosis of acute pulmonary embolism with spiral CT Comparison with pulmonary angiography and scintigraphy. Radiology 200:699–706PubMed Remy-Jardin M, Remy J, Petyt L, Duhamel A (1996). Diagnosis of acute pulmonary embolism with spiral CT Comparison with pulmonary angiography and scintigraphy. Radiology 200:699–706PubMed
20.
go back to reference Ferretti G, Bosson J, Buffaz P (1997) Acute pulmonary embolism role of helical CT in 164 patients with intermediate probability at ventilation-perfusion scintigraphy and normal results at duplex US of the legs. Radiology 205:453–458PubMed Ferretti G, Bosson J, Buffaz P (1997) Acute pulmonary embolism role of helical CT in 164 patients with intermediate probability at ventilation-perfusion scintigraphy and normal results at duplex US of the legs. Radiology 205:453–458PubMed
21.
go back to reference van Rossum AB, Pattynama PM, Mallens WM, Hermans J, Heijerman HG (1998) Can helical CT replace scintigraphy in the diagnostic process in suspected pulmonary embolism? A retrolective-prolective cohort study focusing on total diagnostic yield. Eur Radiol 8:90–96PubMedCrossRef van Rossum AB, Pattynama PM, Mallens WM, Hermans J, Heijerman HG (1998) Can helical CT replace scintigraphy in the diagnostic process in suspected pulmonary embolism? A retrolective-prolective cohort study focusing on total diagnostic yield. Eur Radiol 8:90–96PubMedCrossRef
22.
go back to reference Drucker E, Rivitz S, Shepard J (1998) Acute pulmonary embolism: assessment of helical CT for diagnosis. Radiology 209:235–241PubMed Drucker E, Rivitz S, Shepard J (1998) Acute pulmonary embolism: assessment of helical CT for diagnosis. Radiology 209:235–241PubMed
23.
go back to reference Herold C, Remy-Jardin M, Grenier P (1998) Prospective evaluation of pulmonary embolism initial results of the European multicenter trial (ESTIPEP) [abstract]. Radiology 209:299 Herold C, Remy-Jardin M, Grenier P (1998) Prospective evaluation of pulmonary embolism initial results of the European multicenter trial (ESTIPEP) [abstract]. Radiology 209:299
24.
go back to reference Garg K, Welsh C, Feyerabend A (1998) Pulmonary embolism diagnosis with spiral CT and ventilation-perfusion scanning-correlation with pulmonary angiographic results or clinical outcome. Radiology 208:201–208PubMed Garg K, Welsh C, Feyerabend A (1998) Pulmonary embolism diagnosis with spiral CT and ventilation-perfusion scanning-correlation with pulmonary angiographic results or clinical outcome. Radiology 208:201–208PubMed
25.
go back to reference Baghaie F, Remy-Jardin M, Remy J, Fribourg M (1998) Diagnosis of peripheral acute pulmonary emboli: optimization of the spiral CT acquisition protocol [abstract]. Radiology 209:299 Baghaie F, Remy-Jardin M, Remy J, Fribourg M (1998) Diagnosis of peripheral acute pulmonary emboli: optimization of the spiral CT acquisition protocol [abstract]. Radiology 209:299
26.
go back to reference Kim K, Muller N, Mayo J (1999) Clinically suspected pulmonary embolism: utility of spiral CT. Radiology 210:693–697PubMed Kim K, Muller N, Mayo J (1999) Clinically suspected pulmonary embolism: utility of spiral CT. Radiology 210:693–697PubMed
27.
go back to reference Brunot S, Corneloup O, Latrabe V, Montaudon M, Laurent F (2005) Reproducibility of multi-detector spiral computed tomography in detection of sub-segmental acute pulmonary embolism. Eur Radiol 15:2057–2063PubMedCrossRef Brunot S, Corneloup O, Latrabe V, Montaudon M, Laurent F (2005) Reproducibility of multi-detector spiral computed tomography in detection of sub-segmental acute pulmonary embolism. Eur Radiol 15:2057–2063PubMedCrossRef
28.
go back to reference Le Gal G, Righini M, Parent F, van Strijen M, Couturaud F (2006) Diagnosis and management of subsegmental pulmonary embolism. J Thromb Haemost 4:724–731PubMedCrossRef Le Gal G, Righini M, Parent F, van Strijen M, Couturaud F (2006) Diagnosis and management of subsegmental pulmonary embolism. J Thromb Haemost 4:724–731PubMedCrossRef
29.
go back to reference Wood KE (2002) Major pulmonary embolism: review of a pathophysiologic approach to the golden hour of hemodynamically significant pulmonary embolism. Chest 121:877–905PubMedCrossRef Wood KE (2002) Major pulmonary embolism: review of a pathophysiologic approach to the golden hour of hemodynamically significant pulmonary embolism. Chest 121:877–905PubMedCrossRef
30.
go back to reference Egermayer P (2001) Differences in the rate of anticoagulant complications between routine practice and controlled prospective trials [letter]. J Intern Med 250:258–261PubMedCrossRef Egermayer P (2001) Differences in the rate of anticoagulant complications between routine practice and controlled prospective trials [letter]. J Intern Med 250:258–261PubMedCrossRef
31.
go back to reference Zhou C, Chan HP, Patel S, Cascade PN, Sahiner B, Hadjiiski LM, Kazerooni EA (2005) Preliminary investigation of computer-aided detection of pulmonary embolism in three-dimensional computed tomography pulmonary angiography images. Acad Radiol 12:782–792PubMedCrossRef Zhou C, Chan HP, Patel S, Cascade PN, Sahiner B, Hadjiiski LM, Kazerooni EA (2005) Preliminary investigation of computer-aided detection of pulmonary embolism in three-dimensional computed tomography pulmonary angiography images. Acad Radiol 12:782–792PubMedCrossRef
32.
go back to reference Masutani Y, MacMahon H, Doi K (2002) Computerized detection of pulmonary embolism in spiral CT angiography based on volumetric image analysis. IEEE Trans Med Imaging 21:1517–1523PubMedCrossRef Masutani Y, MacMahon H, Doi K (2002) Computerized detection of pulmonary embolism in spiral CT angiography based on volumetric image analysis. IEEE Trans Med Imaging 21:1517–1523PubMedCrossRef
33.
go back to reference Liang J, Bi J (2007) Computer aided detection of pulmonary embolism with tobogganing and multiple instance classification in CT pulmonary angiography. Inf Process Med Imaging 20:630–641PubMedCrossRef Liang J, Bi J (2007) Computer aided detection of pulmonary embolism with tobogganing and multiple instance classification in CT pulmonary angiography. Inf Process Med Imaging 20:630–641PubMedCrossRef
34.
go back to reference Armitage P, Berry G, Matthews JNS (2002) Statistical methods in medical research (4th edn). Blackwell, Oxford Armitage P, Berry G, Matthews JNS (2002) Statistical methods in medical research (4th edn). Blackwell, Oxford
35.
go back to reference Press WH et al (1992) Numerical recipes: the art of scientific computing (2nd edn). Cambridge University Press, Cambridge Press WH et al (1992) Numerical recipes: the art of scientific computing (2nd edn). Cambridge University Press, Cambridge
36.
go back to reference Hanley JA, McNeil BJ (1982) The meaning and use of area under a Receiver Operating Characteristic (ROC) curve. Radiology 143:29–36PubMed Hanley JA, McNeil BJ (1982) The meaning and use of area under a Receiver Operating Characteristic (ROC) curve. Radiology 143:29–36PubMed
37.
go back to reference DeLong ER, DeLong DM, Clark-Pearson DL (1988) Comparing the areas under two or more correlated receiver operating curves: a nonparametric approach. Biometrics 44:837–845PubMedCrossRef DeLong ER, DeLong DM, Clark-Pearson DL (1988) Comparing the areas under two or more correlated receiver operating curves: a nonparametric approach. Biometrics 44:837–845PubMedCrossRef
38.
go back to reference Fleiss JL (1981) Statistical methods for rates and proportions (2nd edn). Wiley, New York Fleiss JL (1981) Statistical methods for rates and proportions (2nd edn). Wiley, New York
39.
go back to reference Fleiss JL, Nee CM, Landis JR (1979) Large sample variance of kappa in the case of different sets of raters. Psychol Bull 86:974–977CrossRef Fleiss JL, Nee CM, Landis JR (1979) Large sample variance of kappa in the case of different sets of raters. Psychol Bull 86:974–977CrossRef
40.
go back to reference Marten K, Grillhösl A, Seyfarth T, Obenauer S, Rummeny EJ, Engelke C (2005) Computer-assisted detection of pulmonary nodules: evaluation of diagnostic performance using an expert knowledge-based detection system with variable reconstruction slice thickness settings. Eur Radiol 15:203–212PubMedCrossRef Marten K, Grillhösl A, Seyfarth T, Obenauer S, Rummeny EJ, Engelke C (2005) Computer-assisted detection of pulmonary nodules: evaluation of diagnostic performance using an expert knowledge-based detection system with variable reconstruction slice thickness settings. Eur Radiol 15:203–212PubMedCrossRef
41.
go back to reference Croisille P, Souto M, Cova M, Wood S, Afework Y, Kuhlman J, Zerhouni E (1995) Pulmonary nodules: improved detection with vascular segmentation and extraction with spiral CT. Radiology 197:397–401PubMed Croisille P, Souto M, Cova M, Wood S, Afework Y, Kuhlman J, Zerhouni E (1995) Pulmonary nodules: improved detection with vascular segmentation and extraction with spiral CT. Radiology 197:397–401PubMed
42.
go back to reference Wormanns D, Fiebich M, Saidi M, Diederich S, Heindel W (2002) Automatic detection of pulmonary nodules at spiral CT: clinical application of a computer-aided diagnosis system. Eur Radiol 12:1052–1057PubMedCrossRef Wormanns D, Fiebich M, Saidi M, Diederich S, Heindel W (2002) Automatic detection of pulmonary nodules at spiral CT: clinical application of a computer-aided diagnosis system. Eur Radiol 12:1052–1057PubMedCrossRef
43.
go back to reference Marten K, Engelke C (2007) Computer-aided detection and automated CT volumetry of pulmonary nodules. Eur Radiol 17:888–901PubMedCrossRef Marten K, Engelke C (2007) Computer-aided detection and automated CT volumetry of pulmonary nodules. Eur Radiol 17:888–901PubMedCrossRef
44.
go back to reference Armato SG III, Giger ML, Moran CJ, Blackburn JT, Doi K, MacMahon H (1999) Computerized detection of pulmonary nodules on CT scans. Radiographics 19:1303–1311PubMed Armato SG III, Giger ML, Moran CJ, Blackburn JT, Doi K, MacMahon H (1999) Computerized detection of pulmonary nodules on CT scans. Radiographics 19:1303–1311PubMed
45.
go back to reference Armato SG III, Li F, Giger ML, MacMahon H, Sone S, Doi K (2002) Lung cancer: performance of automated lung nodule detection applied to cancers missed in a CT screening program. Radiology 225:685–692PubMedCrossRef Armato SG III, Li F, Giger ML, MacMahon H, Sone S, Doi K (2002) Lung cancer: performance of automated lung nodule detection applied to cancers missed in a CT screening program. Radiology 225:685–692PubMedCrossRef
46.
go back to reference Rubin G, Naidich D, Sherbondy A, Lyo J, Napel S (2003) Inadequacy of lung nodule reference standard based upon standard methods of expert consensus review using cine-paging of transverse thin-section MDCT lung scans [abstract]. Radiology 229:441–442 Rubin G, Naidich D, Sherbondy A, Lyo J, Napel S (2003) Inadequacy of lung nodule reference standard based upon standard methods of expert consensus review using cine-paging of transverse thin-section MDCT lung scans [abstract]. Radiology 229:441–442
47.
go back to reference Marten K, Seyfarth T, Auer F, Wiener E, Grillhösl A, Obenauer S, Rummeny EJ, Engelke C (2004) Computer-assisted detection of pulmonary nodules: performance evaluation of an expert knowledge-based detection system in consensus reading with experienced and inexperienced chest radiologists. Eur Radiol 14:1930–1938PubMedCrossRef Marten K, Seyfarth T, Auer F, Wiener E, Grillhösl A, Obenauer S, Rummeny EJ, Engelke C (2004) Computer-assisted detection of pulmonary nodules: performance evaluation of an expert knowledge-based detection system in consensus reading with experienced and inexperienced chest radiologists. Eur Radiol 14:1930–1938PubMedCrossRef
48.
go back to reference Awai K, Murao K, Ozawa A et al (2004) Pulmonary nodules at chest CT: effect of computer-aided diagnosis on radiologists´detection performance. Radiology 230:347–352PubMedCrossRef Awai K, Murao K, Ozawa A et al (2004) Pulmonary nodules at chest CT: effect of computer-aided diagnosis on radiologists´detection performance. Radiology 230:347–352PubMedCrossRef
49.
go back to reference Schoepf UJ, Das M, Schneider AC et al (2002) Computer-aided detection (CAD) of segmental and subsegmental pulmonary embolism on 1-mm multidetector-row CT (MDCT) studies [abstract]. Radiology 225:384 Schoepf UJ, Das M, Schneider AC et al (2002) Computer-aided detection (CAD) of segmental and subsegmental pulmonary embolism on 1-mm multidetector-row CT (MDCT) studies [abstract]. Radiology 225:384
50.
go back to reference Zhou C, Hadjiiski LM, Sahiner B et al (2003) Computerized detection of pulmonary embolism in 3D computed tomographic (CT) images: vessel tracking and segmentation techniques. Proc SPIE 5032:1613–1620CrossRef Zhou C, Hadjiiski LM, Sahiner B et al (2003) Computerized detection of pulmonary embolism in 3D computed tomographic (CT) images: vessel tracking and segmentation techniques. Proc SPIE 5032:1613–1620CrossRef
51.
go back to reference Buhmann S, Herzog P, Liang J, Wolf M, Salganicoff M, Kirchhoff C, Reiser M, Becker CH (2007) Clinical evaluation of a computer-aided diagnosis (CAD) prototype for the detection of pulmonary embolism. Acad Radiol 14:651–658PubMedCrossRef Buhmann S, Herzog P, Liang J, Wolf M, Salganicoff M, Kirchhoff C, Reiser M, Becker CH (2007) Clinical evaluation of a computer-aided diagnosis (CAD) prototype for the detection of pulmonary embolism. Acad Radiol 14:651–658PubMedCrossRef
52.
go back to reference Quiroz R, Kucher N, Schoepf UJ et al (2004) Right ventricular enlargement on chest computed tomography: prognostic role in acute pulmonary embolism. Circulation 109:2401–2404PubMedCrossRef Quiroz R, Kucher N, Schoepf UJ et al (2004) Right ventricular enlargement on chest computed tomography: prognostic role in acute pulmonary embolism. Circulation 109:2401–2404PubMedCrossRef
53.
go back to reference Engelke C, Rummeny EJ, Marten K (2006) Acute pulmonary embolism on multidetector-row CT of the chest: prediction of cor pulmonale and short-term patient survival from morphological embolus burden. AJR Am J Roentgenol 186:1265–1271PubMedCrossRef Engelke C, Rummeny EJ, Marten K (2006) Acute pulmonary embolism on multidetector-row CT of the chest: prediction of cor pulmonale and short-term patient survival from morphological embolus burden. AJR Am J Roentgenol 186:1265–1271PubMedCrossRef
54.
go back to reference Mastora I, Remy-Jardin M, Masson P et al (2003) Severity of acute pulmonary embolism: evaluation of a new spiral CT angiographic score in correlation with echocardiographic data. Eur Radiol 13:29–35PubMed Mastora I, Remy-Jardin M, Masson P et al (2003) Severity of acute pulmonary embolism: evaluation of a new spiral CT angiographic score in correlation with echocardiographic data. Eur Radiol 13:29–35PubMed
55.
go back to reference Pech M, Wieners G, Dul P, Fischbach F, Dudeck O, Hänninen EL, Ricke J (2007) Computed tomography pulmonary embolism index for the assessment of survival in patients with pulmonary embolism. Eur Radiol 17:1954–1959PubMedCrossRef Pech M, Wieners G, Dul P, Fischbach F, Dudeck O, Hänninen EL, Ricke J (2007) Computed tomography pulmonary embolism index for the assessment of survival in patients with pulmonary embolism. Eur Radiol 17:1954–1959PubMedCrossRef
Metadata
Title
Computer-assisted detection of pulmonary embolism: performance evaluation in consensus with experienced and inexperienced chest radiologists
Authors
Christoph Engelke
Stephan Schmidt
Annemarie Bakai
Florian Auer
Katharina Marten
Publication date
01-02-2008
Publisher
Springer-Verlag
Published in
European Radiology / Issue 2/2008
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-007-0770-3

Other articles of this Issue 2/2008

European Radiology 2/2008 Go to the issue