Skip to main content
Top
Published in: European Radiology 2/2005

01-02-2005 | Cardiac

Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time

Authors: Xavier L. Hamoir, Thomas Flohr, Vincent Hamoir, Laurent Labaki, Jean-Yves Tricquet, Alain Duhamel, Jacques Kirsch

Published in: European Radiology | Issue 2/2005

Login to get access

Abstract

Our objective was to evaluate the image quality of a 16-slice CT system with a rotation time of 375 ms in the assessment of coronary arteries. One hundred patients underwent iodine-enhanced CT coronary angiography within a single breath hold. Images were reconstructed in diastole, 300, 350, 400, 450, 500 and 550 ms prior to the onset of the next R-wave using absolute reverse retrospective ECG gating. The 15 coronary segments of the AHA classification were consensually reviewed by two radiologists. On the whole, best quality imaging was obtained with reconstruction intervals of −350 ms and −400 ms in high percentages of each segment (P<0.0001). Only 6.2% of the arteries with a diameter greater than or equal to 1.5 mm were not assessable because of extensive calcifications (3.9%), cardiac motion artifacts (1.9%), lack of enhancement (0.2%) and stent artifacts (0.3%). In patients with a heart rate above 70 beats per minute, the percentage of assessable segments decreased to 88%, while at a lower heart rate it increased to 95%. In 61% of the patients, all segments were assessable. In conclusion, this generation of CT technique may allow visualization of coronary arteries with a low percentage of non-assessable segments.
Literature
1.
go back to reference Rodenwaldt J (2003) Multislice computed tomography of the coronary arteries. Eur Radiol 13:748–757PubMed Rodenwaldt J (2003) Multislice computed tomography of the coronary arteries. Eur Radiol 13:748–757PubMed
2.
go back to reference Kopp AF, Kuettner A, Trabold T, Heuschmid M, Schroder S, Claussen CD (2003) MDCT: cardiology indications. Eur Radiol 13:M102–M115PubMed Kopp AF, Kuettner A, Trabold T, Heuschmid M, Schroder S, Claussen CD (2003) MDCT: cardiology indications. Eur Radiol 13:M102–M115PubMed
3.
go back to reference Jung B, Mahnken AH, Stargardt A, Simon J, Flohr TG, Schaller S, Koos R, Gunther RW, Wildberger JE (2003) Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart. Eur Radiol 13:2560–2566CrossRefPubMed Jung B, Mahnken AH, Stargardt A, Simon J, Flohr TG, Schaller S, Koos R, Gunther RW, Wildberger JE (2003) Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart. Eur Radiol 13:2560–2566CrossRefPubMed
4.
go back to reference Jakobs TF, Becker CR, Ohnesorge B, Flohr T, Suess C, Schoepf UJ, Reiser MF (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12:1081–1086CrossRefPubMed Jakobs TF, Becker CR, Ohnesorge B, Flohr T, Suess C, Schoepf UJ, Reiser MF (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12:1081–1086CrossRefPubMed
5.
go back to reference Flohr T, Schoepf J, Kuettner A, Halliburton S, Bruder H, Suess C, Schmidt B, Hofmann L, Yucel EK, Schaller S, Ohnesorge B (2003) Advances in cardiac imaging with 16-section CT systems. Acad Radiol 10:386–401CrossRefPubMed Flohr T, Schoepf J, Kuettner A, Halliburton S, Bruder H, Suess C, Schmidt B, Hofmann L, Yucel EK, Schaller S, Ohnesorge B (2003) Advances in cardiac imaging with 16-section CT systems. Acad Radiol 10:386–401CrossRefPubMed
6.
go back to reference Kopp AF, Schroeder S, Kuettner A, Heuschmid M, Georg C, Ohnesorge B, Kuzo R, Claussen CD (2001) Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window. Radiology 221:683–688PubMed Kopp AF, Schroeder S, Kuettner A, Heuschmid M, Georg C, Ohnesorge B, Kuzo R, Claussen CD (2001) Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window. Radiology 221:683–688PubMed
7.
go back to reference Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council Cardiovascular Surgery, American Heart Association (1975) A reporting system on patients evaluated for coronary artery disease. Circulation 51:5–40 Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council Cardiovascular Surgery, American Heart Association (1975) A reporting system on patients evaluated for coronary artery disease. Circulation 51:5–40
8.
go back to reference Flohr T, Ohnesorge B (2001) Heart rate adaptative optimization of spatial and temporal resolution for ECG-gated multi-slice spiral CT of the heart. J Comput Assist Tomogr 25:907–923CrossRefPubMed Flohr T, Ohnesorge B (2001) Heart rate adaptative optimization of spatial and temporal resolution for ECG-gated multi-slice spiral CT of the heart. J Comput Assist Tomogr 25:907–923CrossRefPubMed
9.
go back to reference Giesler T, Baum U, Ropers D, Ulzheimer S, Wenkel E, Mennicke M, Bautz W, Kalender WA, Daniel WG, Achenbach S (2002) Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection. Am J Roentgenol 179:911–916 Giesler T, Baum U, Ropers D, Ulzheimer S, Wenkel E, Mennicke M, Bautz W, Kalender WA, Daniel WG, Achenbach S (2002) Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection. Am J Roentgenol 179:911–916
10.
go back to reference Nieman K, Oudkerk M, Rensing BJ, van Ooijen P, Munne A, van Geuns RJ, de Feyter PJ (2001) Coronary angiography with multi-slice computed tomography. Lancet 357:599–603CrossRefPubMed Nieman K, Oudkerk M, Rensing BJ, van Ooijen P, Munne A, van Geuns RJ, de Feyter PJ (2001) Coronary angiography with multi-slice computed tomography. Lancet 357:599–603CrossRefPubMed
11.
go back to reference Sato YS, Matsumoto N, Kato M, Inoue F, Horie T, Kusama J, Yoshimura A, Imazeki T, Fukui T, Furuhashi S, Takahashi M, Kanmatsuse K (2003) Noninvasive assessment of coronary artery disease by multislice spiral computed tomography using a new retrospectively ECG-gated image reconstruction technique. Circ J 67:401–405CrossRefPubMed Sato YS, Matsumoto N, Kato M, Inoue F, Horie T, Kusama J, Yoshimura A, Imazeki T, Fukui T, Furuhashi S, Takahashi M, Kanmatsuse K (2003) Noninvasive assessment of coronary artery disease by multislice spiral computed tomography using a new retrospectively ECG-gated image reconstruction technique. Circ J 67:401–405CrossRefPubMed
12.
go back to reference Vogl TJ, Abolmaali ND, Diebold T, Engelmann K, Ay M, Dogan M, Wimmer-Greinecker G, Moritz A, Herzog C (2002) Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. Radiology 223:212–220PubMed Vogl TJ, Abolmaali ND, Diebold T, Engelmann K, Ay M, Dogan M, Wimmer-Greinecker G, Moritz A, Herzog C (2002) Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. Radiology 223:212–220PubMed
13.
go back to reference Kopp AF, Kuttner A, Heuschmid M, Schroder S, Ohnesorge B, Claussen CD (2002) Multidetector-row CT cardiac imaging with 4 and 16 slices for coronary CTA and imaging of atherosclerotic plaques. Eur Radiol 12:S17–S24CrossRefPubMed Kopp AF, Kuttner A, Heuschmid M, Schroder S, Ohnesorge B, Claussen CD (2002) Multidetector-row CT cardiac imaging with 4 and 16 slices for coronary CTA and imaging of atherosclerotic plaques. Eur Radiol 12:S17–S24CrossRefPubMed
14.
go back to reference Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B, Schlundt C, Bautz W, Daniel WG, Achenbach S (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666CrossRefPubMed Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Ohnesorge B, Schlundt C, Bautz W, Daniel WG, Achenbach S (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666CrossRefPubMed
15.
go back to reference Dewey M, Schnapauff D, Laule M, Lembcke A, Borges AC, Rutsch W, Hamm B, Rogalla P (2004) Multislice CT coronary angiography: evaluation of an automatic vessel detection tool. Rofo 176:478–483PubMed Dewey M, Schnapauff D, Laule M, Lembcke A, Borges AC, Rutsch W, Hamm B, Rogalla P (2004) Multislice CT coronary angiography: evaluation of an automatic vessel detection tool. Rofo 176:478–483PubMed
16.
go back to reference Herzog C, Abolmaali N, Balzer JO, Baunach S, Ackermann H, Dogan S, Britten MB, Vogl TJ (2002) Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678PubMed Herzog C, Abolmaali N, Balzer JO, Baunach S, Ackermann H, Dogan S, Britten MB, Vogl TJ (2002) Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678PubMed
17.
go back to reference Nieman K, Rensing BJ, van Geuns RJM, Vos J, Pattynama PMT, Krestin GP, Serruys PW, de Feyter PJ (2002) Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate. Heart 88:470–474CrossRefPubMed Nieman K, Rensing BJ, van Geuns RJM, Vos J, Pattynama PMT, Krestin GP, Serruys PW, de Feyter PJ (2002) Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate. Heart 88:470–474CrossRefPubMed
18.
go back to reference Kopp AF, Schroeder S, Kuettner A, Baumbach A, Georg C, Kuzo R, Heuschmid M, Ohnesorge B, Karsch KR, Claussen CD (2002) Non-invasive coronary angiography with high resolution multidetector-row computed tomography: results in 102 patients. Eur Heart J 23:1714–1725PubMed Kopp AF, Schroeder S, Kuettner A, Baumbach A, Georg C, Kuzo R, Heuschmid M, Ohnesorge B, Karsch KR, Claussen CD (2002) Non-invasive coronary angiography with high resolution multidetector-row computed tomography: results in 102 patients. Eur Heart J 23:1714–1725PubMed
Metadata
Title
Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time
Authors
Xavier L. Hamoir
Thomas Flohr
Vincent Hamoir
Laurent Labaki
Jean-Yves Tricquet
Alain Duhamel
Jacques Kirsch
Publication date
01-02-2005
Publisher
Springer-Verlag
Published in
European Radiology / Issue 2/2005
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2541-8

Other articles of this Issue 2/2005

European Radiology 2/2005 Go to the issue