Skip to main content
Top
Published in: European Radiology 2/2005

01-02-2005 | Vascular-Interventional

Abdominal aortic aneurysms: virtual imaging and analysis through a remote web server

Authors: Emanuele Neri, Irene Bargellini, Michael Rieger, Andrea Giachetti, Claudio Vignali, Massimiliano Tuveri, Werner Jaschke, Carlo Bartolozzi

Published in: European Radiology | Issue 2/2005

Login to get access

Abstract

The study describes the application of a web-based software in the planning of the endovascular treatment of abdominal aortic aneurysms (AAA). The software has been developed in the framework of a 2-year research project called Aneurysm QUAntification Through an Internet Collaborative System (AQUATICS); it allows to manage remotely Virtual Reality Modeling Language (VRML) models of the abdominal aorta, derived from multirow computed tomography angiography (CTA) data sets, and to obtain measurements of diameters, angles and centerline lengths. To test the reliability of measurements, two radiologists performed a detailed analysis of multiple 3D models generated from a synthetic phantom, mimicking an AAA. The system was tested on 30 patients with AAA; CTA data sets were mailed and the time required for segmentation and measurement were collected for each case. The Bland-Altman plot analysis showed that the mean intra- and inter-observer differences in measures on phantoms were clinically acceptable. The mean time required for segmentation was 1 h (range 45–120 min). The mean time required for measurements on the web was 7 min (range 4–11 min). The AQUATICS web server may provide a rapid, standardized and accurate tool for the evaluation of AAA prior to the endovascular treatment.
Literature
1.
go back to reference Parodi JC, Palmaz JC, Barone HD (1991) Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 5:491–499PubMed Parodi JC, Palmaz JC, Barone HD (1991) Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 5:491–499PubMed
2.
go back to reference D’Ayala M, Hollier LH, Marin ML (1998) Endovascular grafting for abdominal aortic aneurysms. Surg Clin North Am 78:845–862PubMed D’Ayala M, Hollier LH, Marin ML (1998) Endovascular grafting for abdominal aortic aneurysms. Surg Clin North Am 78:845–862PubMed
3.
go back to reference Moore WS, Rutherford RB (1996) Transfemoral endovascular repair of abdominal aortic aneurysm: results of the North American EVT phase 1 trial. EVT Investigators. J Vasc Surg 23:543–553PubMed Moore WS, Rutherford RB (1996) Transfemoral endovascular repair of abdominal aortic aneurysm: results of the North American EVT phase 1 trial. EVT Investigators. J Vasc Surg 23:543–553PubMed
4.
go back to reference May J, White GH, Yu W, Waugh RC, Stephen MS, Harris JP (1996) Results of endoluminal grafting of abdominal aortic aneurysms are dependent on aneurysm morphology. Ann Vasc Surg 10(3):254–261PubMed May J, White GH, Yu W, Waugh RC, Stephen MS, Harris JP (1996) Results of endoluminal grafting of abdominal aortic aneurysms are dependent on aneurysm morphology. Ann Vasc Surg 10(3):254–261PubMed
5.
go back to reference Tillich M, Bell RE, Paik DS et al (2001) Iliac arterial injuries after endovascular repair of abdominal aortic aneurysms: correlation with iliac curvature and diameter. Radiology 219(1):129–136PubMed Tillich M, Bell RE, Paik DS et al (2001) Iliac arterial injuries after endovascular repair of abdominal aortic aneurysms: correlation with iliac curvature and diameter. Radiology 219(1):129–136PubMed
6.
go back to reference Hovsepian DM, Hein AN, Pilgram TK et al (2001) Endovascular abdominal aortic aneurysm repair in 144 patients: correlation of aneurysm size, proximal aortic neck length, and procedure-related complications. J Vasc Interv Radiol 12(12):1373–1382PubMed Hovsepian DM, Hein AN, Pilgram TK et al (2001) Endovascular abdominal aortic aneurysm repair in 144 patients: correlation of aneurysm size, proximal aortic neck length, and procedure-related complications. J Vasc Interv Radiol 12(12):1373–1382PubMed
7.
go back to reference Wolf YG, Tillich M, Lee WA, Rubin GD, Fogarty TJ, Zarins CK (2001) Impact of aortoiliac tortuosity on endovascular repair of abdominal aortic aneurysms: evaluation of 3D computer-based assessment. J Vasc Surg 34(4):594–599CrossRefPubMed Wolf YG, Tillich M, Lee WA, Rubin GD, Fogarty TJ, Zarins CK (2001) Impact of aortoiliac tortuosity on endovascular repair of abdominal aortic aneurysms: evaluation of 3D computer-based assessment. J Vasc Surg 34(4):594–599CrossRefPubMed
8.
go back to reference Gomes MN, Davros WJ, Zeman RK (1994) Preoperative assessment of abdominal aortic aneurysm: the value of helical and three-dimensional computed tomography. J Vasc Surg 20(3):367–375PubMed Gomes MN, Davros WJ, Zeman RK (1994) Preoperative assessment of abdominal aortic aneurysm: the value of helical and three-dimensional computed tomography. J Vasc Surg 20(3):367–375PubMed
9.
go back to reference Broeders IA, Blankensteijn JD, Olree M, Mali W, Eikelboom BC (1997) Preoperative sizing of grafts for transfemoral endovascular aneurysm management: a prospective comparative study of spiral CT angiography, arteriography, and conventional CT imaging. J Endovasc Surg 4(3):252–261CrossRefPubMed Broeders IA, Blankensteijn JD, Olree M, Mali W, Eikelboom BC (1997) Preoperative sizing of grafts for transfemoral endovascular aneurysm management: a prospective comparative study of spiral CT angiography, arteriography, and conventional CT imaging. J Endovasc Surg 4(3):252–261CrossRefPubMed
10.
go back to reference Broeders IA, Blankensteijn JD (1999) Preoperative imaging of the aortoiliac anatomy in endovascular aneurysm surgery. Semin Vasc Surg 12(4):306–314PubMed Broeders IA, Blankensteijn JD (1999) Preoperative imaging of the aortoiliac anatomy in endovascular aneurysm surgery. Semin Vasc Surg 12(4):306–314PubMed
11.
go back to reference Armon MP, Whitaker SC, Gregson RH, Wenham PW, Hopkinson BR (1998) Spiral CT angiography versus aortography in the assessment of aortoiliac length in patients undergoing endovascular abdominal aortic aneurysm repair. J Endovasc Surg 5(3):222–227CrossRefPubMed Armon MP, Whitaker SC, Gregson RH, Wenham PW, Hopkinson BR (1998) Spiral CT angiography versus aortography in the assessment of aortoiliac length in patients undergoing endovascular abdominal aortic aneurysm repair. J Endovasc Surg 5(3):222–227CrossRefPubMed
12.
go back to reference Beebe HG, Kritpracha B, Serres S, Pigott JP, Price CI, Williams DM (2000) Endograft planning without preoperative arteriography: a clinical feasibility study. J Endovasc Ther 7(1):8–15CrossRefPubMed Beebe HG, Kritpracha B, Serres S, Pigott JP, Price CI, Williams DM (2000) Endograft planning without preoperative arteriography: a clinical feasibility study. J Endovasc Ther 7(1):8–15CrossRefPubMed
13.
go back to reference Giachetti A, Tuveri M, Zanetti G (2003) Reconstruction and web distribution of measurable arterial models. Med Image Anal 7(1):79–93CrossRefPubMed Giachetti A, Tuveri M, Zanetti G (2003) Reconstruction and web distribution of measurable arterial models. Med Image Anal 7(1):79–93CrossRefPubMed
14.
go back to reference Kritpracha B, Wolfe J, Beebe HG (2002) CT artifacts of the proximal aortic neck: an important problem in endograft planning. J Endovasc Ther 9(1):103–110CrossRefPubMed Kritpracha B, Wolfe J, Beebe HG (2002) CT artifacts of the proximal aortic neck: an important problem in endograft planning. J Endovasc Ther 9(1):103–110CrossRefPubMed
15.
go back to reference Fillinger MF (1999) New imaging techniques in endovascular surgery. Surg Clin North Am 79:451–475PubMed Fillinger MF (1999) New imaging techniques in endovascular surgery. Surg Clin North Am 79:451–475PubMed
16.
go back to reference Fillinger MF (2001) Computed tomographic scanning. In: Moore WS, Ahn SA (eds) Endovascular surgery, 3rd edn. Saunders, Philadelphia, pp 114–124 Fillinger MF (2001) Computed tomographic scanning. In: Moore WS, Ahn SA (eds) Endovascular surgery, 3rd edn. Saunders, Philadelphia, pp 114–124
17.
go back to reference Abada HT, Sapoval MR, Paul JF, de Maertelaer V, Mousseaux E, Gaux JC (2003) Aneurysmal sizing after endovascular repair in patients with abdominal aortic aneurysm: interobserver variability of various measurement protocols and its clinical relevance. Eur Radiol 13(12):2699–2704CrossRefPubMed Abada HT, Sapoval MR, Paul JF, de Maertelaer V, Mousseaux E, Gaux JC (2003) Aneurysmal sizing after endovascular repair in patients with abdominal aortic aneurysm: interobserver variability of various measurement protocols and its clinical relevance. Eur Radiol 13(12):2699–2704CrossRefPubMed
18.
go back to reference Rubin GD, Paik DS, Johnston PC, Napel S (1998) Measurement of the aorta and its branches with helical CT. Radiology 206(3):823–829PubMed Rubin GD, Paik DS, Johnston PC, Napel S (1998) Measurement of the aorta and its branches with helical CT. Radiology 206(3):823–829PubMed
19.
go back to reference Tillich M, Hill BB, Paik DS et al (2001) Prediction of aortoiliac stent-graft length: comparison of measurement methods. Radiology 220:475–483PubMed Tillich M, Hill BB, Paik DS et al (2001) Prediction of aortoiliac stent-graft length: comparison of measurement methods. Radiology 220:475–483PubMed
20.
go back to reference Lutz AM, Willmann JK, Pfammatter T et al (2003) Evaluation of aortoiliac aneurysm before endovascular repair: comparison of contrast-enhanced magnetic resonance angiography with multidetector row computed tomographic angiography with an automated analysis software tool. J Vasc Surg 37(3):619–627CrossRefPubMed Lutz AM, Willmann JK, Pfammatter T et al (2003) Evaluation of aortoiliac aneurysm before endovascular repair: comparison of contrast-enhanced magnetic resonance angiography with multidetector row computed tomographic angiography with an automated analysis software tool. J Vasc Surg 37(3):619–627CrossRefPubMed
21.
go back to reference Aziz I, Lee J, Lee JT et al (2003) Accuracy of Three-dimensional Simulation in the Sizing of Aortic Endoluminal Devices. Ann Vasc Surg 17(2):129–136CrossRefPubMed Aziz I, Lee J, Lee JT et al (2003) Accuracy of Three-dimensional Simulation in the Sizing of Aortic Endoluminal Devices. Ann Vasc Surg 17(2):129–136CrossRefPubMed
22.
go back to reference Coenegrachts K, Rigauts H, De Letter J (2003) Prediction of aortoiliac stent graft length: comparison of a semiautomated computed tomography angiography method and calibrated aortography. J Comput Assist Tomogr 27(2):284–288 Coenegrachts K, Rigauts H, De Letter J (2003) Prediction of aortoiliac stent graft length: comparison of a semiautomated computed tomography angiography method and calibrated aortography. J Comput Assist Tomogr 27(2):284–288
23.
go back to reference Rott A, Boehm T, Soldner J et al (2002) Computerized modeling based on spiral CT data for noninvasive determination of aortic stent-graft length. J Endovasc Ther 9(4):520–528CrossRefPubMed Rott A, Boehm T, Soldner J et al (2002) Computerized modeling based on spiral CT data for noninvasive determination of aortic stent-graft length. J Endovasc Ther 9(4):520–528CrossRefPubMed
Metadata
Title
Abdominal aortic aneurysms: virtual imaging and analysis through a remote web server
Authors
Emanuele Neri
Irene Bargellini
Michael Rieger
Andrea Giachetti
Claudio Vignali
Massimiliano Tuveri
Werner Jaschke
Carlo Bartolozzi
Publication date
01-02-2005
Publisher
Springer-Verlag
Published in
European Radiology / Issue 2/2005
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2500-4

Other articles of this Issue 2/2005

European Radiology 2/2005 Go to the issue

Calendar of Events

February 2005