Skip to main content
Top
Published in: European Radiology 12/2003

01-12-2003 | Vascular–Interventional

Aneurysmal sizing after endovascular repair in patients with abdominal aortic aneurysm: interobserver variability of various measurement protocols and its clinical relevance

Authors: Hicham T. Abada, Marc R. Sapoval, Jean-François Paul, Viviane de Maertelaer, Elie Mousseaux, Jean-Claude Gaux

Published in: European Radiology | Issue 12/2003

Login to get access

Abstract

The aim of this study was to determine the variability of various measurement protocols for measurement of abdominal aortic aneurysm (AAA) and the clinical relevance of variability. Three radiologists performed computed tomographic angiography measurements of both the aorta and the largest portion of the aneurysm on selected axial slices. Then measurements of the largest portion of the aneurysm were performed on unselected axial slices, sagittal and coronal reformatted. Finally, aortic volume was calculated. Measurements and volume calculation were performed before and after endovascular repair and assessed: Part 1: interobserver variability for maximum anteroposterior (MAP) and maximum transverse (MTR) diameters on selected slices; part 2: interobserver variability for unselected slices considering MAP and MTR; part 3: interobserver variability considering maximum diameter in any direction (MAD); part 4: interobserver variability for sagittal (SAG) and coronal (COR) free curved multiplanar reformation (MPR); and part 5: volume calculations. We then determined which technique of measurement was the most clinically relevant for detecting changes in aneurysm size or aortic volume. Parts 1 and 2: interobserver variability was 4.1 mm for both MAP and MTR; part 3: interobserver variability was 7 mm for MAD; part 4: interobserver variability was 5.5 mm (COR) and 4.9 mm (SAG); part 5: interobserver variability for volume was 5.5 ml. A combination of MAP and MTR was the most useful for detecting aortic modification. Volume calculation was needed in only a few cases. We recommend avoiding MAD and MPR measurements and suggest instead measuring both maximum anteroposterior and maximum transverse diameters. If aneurysm size remains stable after endovascular repair, aneurysm volume should be measured.
Literature
1.
go back to reference Parodi JC, Criado FJ, Barone HD, Schonholz CS, Queral LA (1994) Endoluminal aortic aneurysm repair using a balloon-expandable stent-graft device: a progress report. Ann Vasc Surg 8:523–529PubMed Parodi JC, Criado FJ, Barone HD, Schonholz CS, Queral LA (1994) Endoluminal aortic aneurysm repair using a balloon-expandable stent-graft device: a progress report. Ann Vasc Surg 8:523–529PubMed
2.
go back to reference Blum U, Langer M, Spillner G et al. (1996) Abdominal aortic aneurysms: preliminary technical and clinical results with transfemoral placement of endovascular self-expanding stent-grafts. Radiol 198:25–31PubMed Blum U, Langer M, Spillner G et al. (1996) Abdominal aortic aneurysms: preliminary technical and clinical results with transfemoral placement of endovascular self-expanding stent-grafts. Radiol 198:25–31PubMed
3.
go back to reference Doffner R, Thurner S, Polterauer P, Kretscnmer G, Lammer J (1997) Treatment of abdominal aortic aneurysms with transfemoral placement of stent-grafts: complications and secondary radiologic intervention. Radiology 204:79–86PubMed Doffner R, Thurner S, Polterauer P, Kretscnmer G, Lammer J (1997) Treatment of abdominal aortic aneurysms with transfemoral placement of stent-grafts: complications and secondary radiologic intervention. Radiology 204:79–86PubMed
4.
go back to reference Uflacker R, Robinson J (2001) Endovascular treatment of abdominal aortic aneurysm: a review. Eur Radiol 11:739–753CrossRefPubMed Uflacker R, Robinson J (2001) Endovascular treatment of abdominal aortic aneurysm: a review. Eur Radiol 11:739–753CrossRefPubMed
5.
go back to reference Thomas PR, Shaw JC, Ashton HA, Kay DN, Scott RA (1994) Accuracy of ultrasound in a screening program for abdominal aortic aneurysms. J Med Screen 1:3–6PubMed Thomas PR, Shaw JC, Ashton HA, Kay DN, Scott RA (1994) Accuracy of ultrasound in a screening program for abdominal aortic aneurysms. J Med Screen 1:3–6PubMed
6.
go back to reference Golzarian J, Dussaussois L, Struyven J (1999) Imaging of abdominal aortic aneurysm after endoluminal repair. Semin Ultrasound CT MR 20:16–24PubMed Golzarian J, Dussaussois L, Struyven J (1999) Imaging of abdominal aortic aneurysm after endoluminal repair. Semin Ultrasound CT MR 20:16–24PubMed
7.
go back to reference Golzarian J, Struyven J (2001) Imaging of complications after endoluminal treatment of abdominal aortic aneurysm. Eur Radiol 11:2244–2251CrossRefPubMed Golzarian J, Struyven J (2001) Imaging of complications after endoluminal treatment of abdominal aortic aneurysm. Eur Radiol 11:2244–2251CrossRefPubMed
8.
go back to reference Golzarian J, Dussaussois L, Abada HT et al. (1998) Helical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition. AJR 171:329–331 Golzarian J, Dussaussois L, Abada HT et al. (1998) Helical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition. AJR 171:329–331
9.
go back to reference Bland JM, Altman DG (1986) Statistical notes: measurement error. Br Med J 313:744 Bland JM, Altman DG (1986) Statistical notes: measurement error. Br Med J 313:744
10.
go back to reference Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 8:307–310 Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 8:307–310
11.
go back to reference White GH, May J, Petrasek P, Waugh R, Stephen M, Harris J (1999) Endotension: an explanation for continued AAA growth after successful endoluminal repair. J Endovas Surg 6:308–315 White GH, May J, Petrasek P, Waugh R, Stephen M, Harris J (1999) Endotension: an explanation for continued AAA growth after successful endoluminal repair. J Endovas Surg 6:308–315
12.
go back to reference Jaakola P, Hippelainen M, Farin P, Rytkonen H, Kainulainen S, Partanen K (1996) Interobserver variability in measuring the dimensions of abdominal aorta: comparison of ultrasound and computed tomography. Eur J Vasc Endovasc Surg 12:230–237PubMed Jaakola P, Hippelainen M, Farin P, Rytkonen H, Kainulainen S, Partanen K (1996) Interobserver variability in measuring the dimensions of abdominal aorta: comparison of ultrasound and computed tomography. Eur J Vasc Endovasc Surg 12:230–237PubMed
13.
go back to reference Lederle FA, Wilson SE, Johnson GR et al. (1995) Variability in measurement of abdominal aortic aneurysms. J Vasc Surg:945–952 Lederle FA, Wilson SE, Johnson GR et al. (1995) Variability in measurement of abdominal aortic aneurysms. J Vasc Surg:945–952
14.
go back to reference Wever JJ, Blankensteijn, van Rijn, Broeders IA, Eikelboom, Mali WP (2000) Inter- and intraobserver variability of CT measurements obtained after endovascular repair. AJR 175:1279–1282 Wever JJ, Blankensteijn, van Rijn, Broeders IA, Eikelboom, Mali WP (2000) Inter- and intraobserver variability of CT measurements obtained after endovascular repair. AJR 175:1279–1282
15.
go back to reference Wolf YG, Tillich M, Lee A, Fogarty TJ, Zarins CK, Rubin GD (2002) Changes in aneurysm volume after endovascular repair of abdominal aortic aneurysm. J Vasc Surg 36:305–309CrossRefPubMed Wolf YG, Tillich M, Lee A, Fogarty TJ, Zarins CK, Rubin GD (2002) Changes in aneurysm volume after endovascular repair of abdominal aortic aneurysm. J Vasc Surg 36:305–309CrossRefPubMed
16.
go back to reference Shin H, Chavan, Witthus F et al. (2001) Precise determination of aortic length in patients with aortic stent-grafts: in-vivo evaluation of a thinning algorithm applied to CT angiography data. Eur Radiol 11:733–738CrossRefPubMed Shin H, Chavan, Witthus F et al. (2001) Precise determination of aortic length in patients with aortic stent-grafts: in-vivo evaluation of a thinning algorithm applied to CT angiography data. Eur Radiol 11:733–738CrossRefPubMed
17.
go back to reference Raman R, Napel S, Beaulieu CF, Bain ES, Brooke JR, Rubin GD (2002) Automated generation of curved planar reformations from volume data: method and evaluation. Radiology 223:275–280PubMed Raman R, Napel S, Beaulieu CF, Bain ES, Brooke JR, Rubin GD (2002) Automated generation of curved planar reformations from volume data: method and evaluation. Radiology 223:275–280PubMed
Metadata
Title
Aneurysmal sizing after endovascular repair in patients with abdominal aortic aneurysm: interobserver variability of various measurement protocols and its clinical relevance
Authors
Hicham T. Abada
Marc R. Sapoval
Jean-François Paul
Viviane de Maertelaer
Elie Mousseaux
Jean-Claude Gaux
Publication date
01-12-2003
Publisher
Springer-Verlag
Published in
European Radiology / Issue 12/2003
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-1914-8

Other articles of this Issue 12/2003

European Radiology 12/2003 Go to the issue