Abstract

We carried out a multicentre study to compare the postoperative femorotibial radiographic axis in two total knee replacement groups; one using manual instrumentation and the other using navigation. In the latter group, three navigation systems were used: Stryker, Orthopilot and Navitrack. The prior circumstances of patients in terms of age, weight, aetiology, epicondylar perimeter, patellar tendon length and knee deformity was similar in both groups. The duration of the operation was longer in the group with navigation (16.7 min). A normal femorotibial axis was more frequently obtained in the group with a navigator compared to the manual group (48.1% and 30%, respectively). A varus axis was most common in the manual group (42.2 and 26.9%, respectively). When we analysed the final postoperative radiographic axis, taking 180° to be a normal result, we noted that cases where manual instrumentation was used deviated by 1.19° more than those carried out with navigation, with this difference being statistically significant (P<0.001). No significant differences were found in the final angle of the extremity with the different navigation systems. The navigation systems used in this study improve the frontal angle of the arthroplasty.
Literature
1.
go back to reference Bargren JH, Blaha JD, Freeman MA (1983) Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop 173:178–183PubMed Bargren JH, Blaha JD, Freeman MA (1983) Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop 173:178–183PubMed
2.
go back to reference Bäthis H, Perlick L, Tingart M, Lüring C, Perlick C, Grifka J (2004) Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty. Int Orthop 28:87–90PubMedCrossRef Bäthis H, Perlick L, Tingart M, Lüring C, Perlick C, Grifka J (2004) Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty. Int Orthop 28:87–90PubMedCrossRef
3.
go back to reference Chauhan SK, Scott RG, Breidhal W, Beaver RJ (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique in terms of component alignment. J Bone Joint Surg Br 86 B:372–377CrossRef Chauhan SK, Scott RG, Breidhal W, Beaver RJ (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique in terms of component alignment. J Bone Joint Surg Br 86 B:372–377CrossRef
4.
go back to reference Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP (2005) Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing navigated and manual implantation. J Arthroplasty 20:282–290PubMedCrossRef Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP (2005) Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing navigated and manual implantation. J Arthroplasty 20:282–290PubMedCrossRef
5.
go back to reference Delp SL, Stulberg SD, Davies B, Picard F, Leitner F (1988) Computer assisted knee replacement. Clin Orthop 354:49–56 Delp SL, Stulberg SD, Davies B, Picard F, Leitner F (1988) Computer assisted knee replacement. Clin Orthop 354:49–56
7.
go back to reference Grutzner PA, Suhm N (2004) Computer aided long bone fracture treatment. Injury 35(Suppl 1):57–64CrossRef Grutzner PA, Suhm N (2004) Computer aided long bone fracture treatment. Injury 35(Suppl 1):57–64CrossRef
8.
go back to reference Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop 433:152–159PubMed Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop 433:152–159PubMed
9.
go back to reference Hart R, Janecek M, Chaker A, Bucek P (2003) Total knee arthroplasty implanted with and without kinematic navigation. Int Orthop 27:366–369PubMedCrossRef Hart R, Janecek M, Chaker A, Bucek P (2003) Total knee arthroplasty implanted with and without kinematic navigation. Int Orthop 27:366–369PubMedCrossRef
10.
go back to reference Jenny JY, Boeri C (2001) Computer-assisted implantation of a total knee arthroplasty: a case controlled study in comparison with classical instrumentation. Rev Chir Orthop 87:645–652PubMed Jenny JY, Boeri C (2001) Computer-assisted implantation of a total knee arthroplasty: a case controlled study in comparison with classical instrumentation. Rev Chir Orthop 87:645–652PubMed
11.
go back to reference Jenny JY, Boeri C (2004) Low reproductibility of the intra-operative measurement of the transepicondylar axis during total knee replacement. Acta Orthop Scand 75:74–77PubMedCrossRef Jenny JY, Boeri C (2004) Low reproductibility of the intra-operative measurement of the transepicondylar axis during total knee replacement. Acta Orthop Scand 75:74–77PubMedCrossRef
12.
go back to reference Laskin RS (2003) Instrumentation pitfalls: you just can’t go on autopilot. J Arthroplasty 18(Suppl 1):18–22PubMedCrossRef Laskin RS (2003) Instrumentation pitfalls: you just can’t go on autopilot. J Arthroplasty 18(Suppl 1):18–22PubMedCrossRef
13.
go back to reference Mahaluxmivala J, Bankes MJK, Nicolai P, Aldam CH, Allen W (2001) The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplasty 16:635–640PubMedCrossRef Mahaluxmivala J, Bankes MJK, Nicolai P, Aldam CH, Allen W (2001) The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplasty 16:635–640PubMedCrossRef
14.
go back to reference Mielke RK, Clemens U, Jens JH, Kershally S (2001) Navigation in knee endoprosthesis implantation. Preliminary experiences and prospective comparative study with conventional implantation technique. Z Orthop Ihre Grenzgeb 139:109–116PubMedCrossRef Mielke RK, Clemens U, Jens JH, Kershally S (2001) Navigation in knee endoprosthesis implantation. Preliminary experiences and prospective comparative study with conventional implantation technique. Z Orthop Ihre Grenzgeb 139:109–116PubMedCrossRef
15.
go back to reference Mihalko WM, Boyle J,Clark LD, Krackow KA (2005) The variability of intramedullary alignment of the femoral component during total knee arthroplasty. J Arthroplasty 20:25–28PubMedCrossRef Mihalko WM, Boyle J,Clark LD, Krackow KA (2005) The variability of intramedullary alignment of the femoral component during total knee arthroplasty. J Arthroplasty 20:25–28PubMedCrossRef
16.
go back to reference Moreland JR, Bassett LW, Hanker GJ (1987) Radiographic analysis of the axial alignment of the lower extremity. J Bone Joint Surg Am 69A:745–749 Moreland JR, Bassett LW, Hanker GJ (1987) Radiographic analysis of the axial alignment of the lower extremity. J Bone Joint Surg Am 69A:745–749
17.
go back to reference Perlick L, Bathis H, Tingart M,Perlick C, Grifka J (2004) Navigation in total-knee arthroplasty. CT-based implantation compared with the conventional technique. Acta Orthop Scand 75:464–770PubMedCrossRef Perlick L, Bathis H, Tingart M,Perlick C, Grifka J (2004) Navigation in total-knee arthroplasty. CT-based implantation compared with the conventional technique. Acta Orthop Scand 75:464–770PubMedCrossRef
18.
go back to reference Plaskos CH, Hodgson AJ, Inkpen K, McGrow RW (2002) Bone cutting errors in total knee arthroplasty. J Arthroplasty 17:698–705PubMedCrossRef Plaskos CH, Hodgson AJ, Inkpen K, McGrow RW (2002) Bone cutting errors in total knee arthroplasty. J Arthroplasty 17:698–705PubMedCrossRef
19.
go back to reference Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop 299:153–156PubMed Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop 299:153–156PubMed
20.
go back to reference Saragaglia D, Picard F, Chaussard C, Montbarbon E, Leitner F, Cinquin P (2001) Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study. Rev Chir Orthop 87:18–28PubMed Saragaglia D, Picard F, Chaussard C, Montbarbon E, Leitner F, Cinquin P (2001) Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study. Rev Chir Orthop 87:18–28PubMed
21.
go back to reference Sikorski JM, Chauhan S (2003) Aspects of current management. Computer-assisted orthopaedic surgery. Do we need CAOS? J Bone Joint Surg Br 85B:319–323CrossRef Sikorski JM, Chauhan S (2003) Aspects of current management. Computer-assisted orthopaedic surgery. Do we need CAOS? J Bone Joint Surg Br 85B:319–323CrossRef
22.
go back to reference Sikorski JM (2004) Computer-assisted revision total knee replacement. J Bone Joint Surg Br 86B:510–514 Sikorski JM (2004) Computer-assisted revision total knee replacement. J Bone Joint Surg Br 86B:510–514
23.
go back to reference Sparmann M, Wolke B, Chupalla H, Banzer A, Zink A (2003) Positioning of total knee arthtroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85B:830–835 Sparmann M, Wolke B, Chupalla H, Banzer A, Zink A (2003) Positioning of total knee arthtroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85B:830–835
24.
go back to reference Stöckl B, Nogler M, Rosiek R, Fisher M, Krismer M, Kessler O (2004) Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop 426:180–186PubMed Stöckl B, Nogler M, Rosiek R, Fisher M, Krismer M, Kessler O (2004) Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop 426:180–186PubMed
Metadata
Title
Navigation in total knee arthroplasty. A multicenter study
Authors
F. Maculé-Beneyto
D. Hernández-Vaquero
J. M. Segur-Vilalta
R. Colomina-Rodríguez
P. Hinarejos-Gomez
I. García-Forcada
B. Seral Garcia
Publication date
01-12-2006
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 6/2006
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-006-0126-7

Other articles of this Issue 6/2006

International Orthopaedics 6/2006 Go to the issue