Skip to main content
Top
Published in: Skeletal Radiology 4/2020

Open Access 01-04-2020 | Computed Tomography | Scientific Article

Ultra-low-dose CT for extremities in an acute setting: initial experience with 203 subjects

Authors: Zlatan Alagic, Robert Bujila, Anders Enocson, Subhash Srivastava, Seppo K. Koskinen

Published in: Skeletal Radiology | Issue 4/2020

Login to get access

Abstract

Objective

The purpose of this study was to assess if ultra-low-dose CT is a useful clinical alternative to digital radiographs in the evaluation of acute wrist and ankle fractures.

Materials and methods

An ultra-low-dose protocol was designed on a 256-slice multi-detector CT. Patients from the emergency department were evaluated prospectively. After initial digital radiographs, an ultra-low-dose CT was performed. Two readers independently analyzed the images. Also, the radiation dose, examination time, and time to preliminary report was compared between digital radiographs and CT.

Results

In 207 extremities, digital radiography and ultra-low-dose CT detected 73 and 109 fractures, respectively (p < 0.001). The odds ratio for fracture detection with ultra-low-dose CT vs. digital radiography was 2.0 (95% CI, 1.4–3.0). CT detected additional fracture-related findings in 33 cases (15.9%) and confirmed or ruled out suspected fractures in 19 cases (9.2%). The mean effective dose was comparable between ultra-low-dose CT and digital radiography (0.59 ± 0.33 μSv, 95% CI 0.47–0.59 vs. 0.53 ± 0.43 μSv, 95% CI 0.54–0.64). The mean combined examination time plus time to preliminary report was shorter for ultra-low-dose CT compared to digital radiography (7.6 ± 2.5 min, 95% CI 7.1–8.1 vs. 9.8 ± 4.7 min, 95% CI 8.8–10.7) (p = 0.002). The recommended treatment changed in 34 (16.4%) extremities.

Conclusions

Ultra-low-dose CT is a useful alternative to digital radiography for imaging the peripheral skeleton in the acute setting as it detects significantly more fractures and provides additional clinically important information, at a comparable radiation dose. It also provides faster combined examination and reporting times.
Literature
1.
go back to reference Guly HR. Diagnostic errors in an accident and emergency department. Emerg Med J. 2001;18(4):263–9.CrossRef Guly HR. Diagnostic errors in an accident and emergency department. Emerg Med J. 2001;18(4):263–9.CrossRef
2.
go back to reference Goldfarb CA, Yin Y, Gilula LA, Fisher AJ, Boyer MI. Wrist fractures: what the clinician wants to know. Radiology. 2001;219(1):11–28.8.CrossRef Goldfarb CA, Yin Y, Gilula LA, Fisher AJ, Boyer MI. Wrist fractures: what the clinician wants to know. Radiology. 2001;219(1):11–28.8.CrossRef
3.
go back to reference Manaster BJ, Roberts CC, Andrews CL, et al. Diagnostic and surgical imaging anatomy: musculoskeletal. Salt Lake City, Utah: Amirsys; 2006. Manaster BJ, Roberts CC, Andrews CL, et al. Diagnostic and surgical imaging anatomy: musculoskeletal. Salt Lake City, Utah: Amirsys; 2006.
4.
go back to reference Hindman BW, Kulik WJ, Lee G, Avolio RE. Occult fractures of the carpals and metacarpals: demonstration by CT. AJR Am J Roentgenol. 1989;153(3):529–32.CrossRef Hindman BW, Kulik WJ, Lee G, Avolio RE. Occult fractures of the carpals and metacarpals: demonstration by CT. AJR Am J Roentgenol. 1989;153(3):529–32.CrossRef
5.
go back to reference Welling RD, Jacobson JA, Jamadar DA, Chong S, Caoili EM, Jebson PJ. MDCT and radiography of wrist fractures: radiographic sensitivity and fracture patterns. AJR Am J Roentgenol. 2008;190(1):10–6.CrossRef Welling RD, Jacobson JA, Jamadar DA, Chong S, Caoili EM, Jebson PJ. MDCT and radiography of wrist fractures: radiographic sensitivity and fracture patterns. AJR Am J Roentgenol. 2008;190(1):10–6.CrossRef
6.
go back to reference Braunstein EM, Goldstein SA, Ku J, Smith P, Matthews LS. Computed tomography and plain radiography in experimental fracture healing. Skelet Radiol. 1986;15(1):27–31.CrossRef Braunstein EM, Goldstein SA, Ku J, Smith P, Matthews LS. Computed tomography and plain radiography in experimental fracture healing. Skelet Radiol. 1986;15(1):27–31.CrossRef
7.
go back to reference Koivisto J, Kiljunen T, Kadesjö N, Shi XQ, Wolff J. Effective radiation dose of a MSCT, two CBCT and one conventional radiography device in the ankle region. J Foot Ankle Res. 2015;8:8.CrossRef Koivisto J, Kiljunen T, Kadesjö N, Shi XQ, Wolff J. Effective radiation dose of a MSCT, two CBCT and one conventional radiography device in the ankle region. J Foot Ankle Res. 2015;8:8.CrossRef
8.
go back to reference McCollough CH, Leng S, Yu L, Cody DD, Boone JM, McNitt-Gray MF. CT dose index and patient dose: they are not the same thing. Radiology. 2011;259:311–6.CrossRef McCollough CH, Leng S, Yu L, Cody DD, Boone JM, McNitt-Gray MF. CT dose index and patient dose: they are not the same thing. Radiology. 2011;259:311–6.CrossRef
9.
go back to reference McLaughlin PD, Ouellette HA, Louis LJ, et al. The emergence of ultra-low—dose computed tomography and the impending obsolescence of the plain radiograph? Can Assoc Radiol J. 2013;64(4):314–8.CrossRef McLaughlin PD, Ouellette HA, Louis LJ, et al. The emergence of ultra-low—dose computed tomography and the impending obsolescence of the plain radiograph? Can Assoc Radiol J. 2013;64(4):314–8.CrossRef
10.
go back to reference Saltybaeva N, Jafari ME, Hupfer M, Kalender WA. Estimates of effective dose for CT scans of the lower extremities. Radiology. 2014;273(1):153–9.CrossRef Saltybaeva N, Jafari ME, Hupfer M, Kalender WA. Estimates of effective dose for CT scans of the lower extremities. Radiology. 2014;273(1):153–9.CrossRef
11.
go back to reference Tapiovaara M, Siiskonen T. PCXMC 2.0: User’s guide. Helsinki, Finland: Finnish Centre for Radiation and Nuclear Safety; 2008. Report No. STUK-TR7. Tapiovaara M, Siiskonen T. PCXMC 2.0: User’s guide. Helsinki, Finland: Finnish Centre for Radiation and Nuclear Safety; 2008. Report No. STUK-TR7.
12.
go back to reference Brink M, Steenbakkers A, Holla M, et al. Single-shot CT after wrist trauma: impact on detection accuracy and treatment of fractures. Skeletal Radio. 2019;48(6):949–57.CrossRef Brink M, Steenbakkers A, Holla M, et al. Single-shot CT after wrist trauma: impact on detection accuracy and treatment of fractures. Skeletal Radio. 2019;48(6):949–57.CrossRef
13.
go back to reference Kim HG, Lee HJ, Lee SK, Kim HJ, Kim MJ. Head CT: image quality improvement with ASIR-V using a reduced radiation dose protocol for children. Eur Radiol. 2017;27(9):3609–17.CrossRef Kim HG, Lee HJ, Lee SK, Kim HJ, Kim MJ. Head CT: image quality improvement with ASIR-V using a reduced radiation dose protocol for children. Eur Radiol. 2017;27(9):3609–17.CrossRef
14.
go back to reference Kwon H, Cho J, Oh J, et al. The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique. Br J Radiol. 2015;88(1054):20150463.CrossRef Kwon H, Cho J, Oh J, et al. The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique. Br J Radiol. 2015;88(1054):20150463.CrossRef
15.
go back to reference Yi JW, Park HJ, Lee SY, et al. Radiation dose reduction in multidetector CT in fracture evaluation. Br J Radiol. 2017;90(1077):20170240.CrossRef Yi JW, Park HJ, Lee SY, et al. Radiation dose reduction in multidetector CT in fracture evaluation. Br J Radiol. 2017;90(1077):20170240.CrossRef
16.
go back to reference Mansfield C, Ali S, Komperda K, Zhao H, Rehman S. Optimizing radiation dose in computed tomography of articular fractures. J Orthop Trauma. 2017;31(8):401–6.CrossRef Mansfield C, Ali S, Komperda K, Zhao H, Rehman S. Optimizing radiation dose in computed tomography of articular fractures. J Orthop Trauma. 2017;31(8):401–6.CrossRef
17.
go back to reference Konda SR, Goch AM, Leucht P, et al. The use of ultra-low-dose CT scans for the evaluation of limb fractures: is the reduced effective dose using ct in orthopaedic injury (REDUCTION) protocol effective? Bone Joint J. 2016;98-B(12):1668–73.CrossRef Konda SR, Goch AM, Leucht P, et al. The use of ultra-low-dose CT scans for the evaluation of limb fractures: is the reduced effective dose using ct in orthopaedic injury (REDUCTION) protocol effective? Bone Joint J. 2016;98-B(12):1668–73.CrossRef
18.
go back to reference Huang AJ, Chang CY, Thomas BJ, MacMahon PJ, Palmer WE. Using cone-beam CT as a low-dose 3D imaging technique for the extremities: initial experience in 50 subjects. Skelet Radiol. 2015;44(6):797–809.CrossRef Huang AJ, Chang CY, Thomas BJ, MacMahon PJ, Palmer WE. Using cone-beam CT as a low-dose 3D imaging technique for the extremities: initial experience in 50 subjects. Skelet Radiol. 2015;44(6):797–809.CrossRef
19.
go back to reference Nardi C, Salerno S, Molteni R, et al. Radiation dose in non-dental cone beam CT applications: a systematic review. Radiol Med. 2018;123(10):765–77.CrossRef Nardi C, Salerno S, Molteni R, et al. Radiation dose in non-dental cone beam CT applications: a systematic review. Radiol Med. 2018;123(10):765–77.CrossRef
20.
go back to reference Brenner DJ, Doll R, Goodhead DT, et al. Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. Proc Natl Acad Sci U S A. 2003;100(24):13761–6.CrossRef Brenner DJ, Doll R, Goodhead DT, et al. Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. Proc Natl Acad Sci U S A. 2003;100(24):13761–6.CrossRef
Metadata
Title
Ultra-low-dose CT for extremities in an acute setting: initial experience with 203 subjects
Authors
Zlatan Alagic
Robert Bujila
Anders Enocson
Subhash Srivastava
Seppo K. Koskinen
Publication date
01-04-2020
Publisher
Springer Berlin Heidelberg
Published in
Skeletal Radiology / Issue 4/2020
Print ISSN: 0364-2348
Electronic ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-019-03309-7

Other articles of this Issue 4/2020

Skeletal Radiology 4/2020 Go to the issue

Test Yourself: Question

Multiple bilateral forearm nodules