Skip to main content
Top
Published in: Skeletal Radiology 8/2014

01-08-2014 | Scientific Article

Technical and clinical outcome of percutaneous CT fluoroscopy-guided screw placement in unstable injuries of the posterior pelvic ring

Authors: Frederik F. Strobl, Sophia M. Haeussler, Philipp M. Paprottka, Ralf-Thorsten Hoffmann, Oliver Pieske, Maximilian F. Reiser, Christoph G. Trumm

Published in: Skeletal Radiology | Issue 8/2014

Login to get access

Abstract

Purpose

To evaluate technical success, complications, and effective dose in patients undergoing CT fluoroscopy-guided iliosacral screw placement for the fixation of unstable posterior pelvic ring injuries.

Materials and methods

Our retrospective analysis includes all consecutive patients with vertical sacral fractures and/or injury of the iliosacral joint treated with CT fluoroscopy-guided screw placement in our department from 11/2005 to 03/2013. Interventions were carried out under general anesthesia and CT fluoroscopy (10–20 mAs; 120 kV; 16- or 128-row scanner, Siemens Healthcare, Erlangen, Germany). Technical outcome, major and minor complications, and effective patient dose were analyzed.

Results

We treated 99 consecutive patients (mean age 53.1 ± 21.7 years, 50 male, 49 female) with posterior pelvic ring instability with CT fluoroscopy-guided screw placement. Intervention was technically successful in all patients (n = 99). No major and one minor local complication occurred (1 %, secondary screw dislocation). General complications included three cases of death (3 %) due to pulmonary embolism (n = 1), hemorrhagic shock (n = 1), or cardiac event (n = 1) during a follow-up period of 30 days. General complications were not related to the intervention. Mean effective patient radiation dose per intervention was 12.28 mSv ± 7.25 mSv. Mean procedural time was 72.1 ± 37.4 min.

Conclusions

CT fluoroscopy-guided screw placement for the treatment of posterior pelvic ring instabilities can be performed with high technical success and a low complication rate. This method provides excellent intrainterventional visualization of iliac and sacral bones, as well as the sacral neuroforamina for precise screw placement by applying an acceptable effective patient dose.
Literature
1.
go back to reference Giannoudis PV, Grotz MR, Tzioupis C, Dinopoulos H, Wells GE, Bouamra O, et al. Prevalence of pelvic fractures, associated injuries, and mortality: the United Kingdom perspective. J Trauma. 2007;63(4):875–83.PubMedCrossRef Giannoudis PV, Grotz MR, Tzioupis C, Dinopoulos H, Wells GE, Bouamra O, et al. Prevalence of pelvic fractures, associated injuries, and mortality: the United Kingdom perspective. J Trauma. 2007;63(4):875–83.PubMedCrossRef
2.
go back to reference Grotz MR, Allami MK, Harwood P, Pape HC, Krettek C, Giannoudis PV. Open pelvic fractures: epidemiology, current concepts of management and outcome. Injury. 2005;36(1):1–13.PubMedCrossRef Grotz MR, Allami MK, Harwood P, Pape HC, Krettek C, Giannoudis PV. Open pelvic fractures: epidemiology, current concepts of management and outcome. Injury. 2005;36(1):1–13.PubMedCrossRef
3.
go back to reference Denis F, Davis S, Comfort T. Sacral fractures: an important problem. Retrospective analysis of 236 cases. Clin Orthop Relat Res. 1988;227:67–81.PubMed Denis F, Davis S, Comfort T. Sacral fractures: an important problem. Retrospective analysis of 236 cases. Clin Orthop Relat Res. 1988;227:67–81.PubMed
4.
go back to reference Dudda M, Hoffmann M, Schildhauer TA. Sacrum fractures and lumbopelvic instabilities in pelvic ring injuries: classification and biomechanical aspects. Unfallchirurg. 2013;116(11):972–8.PubMedCrossRef Dudda M, Hoffmann M, Schildhauer TA. Sacrum fractures and lumbopelvic instabilities in pelvic ring injuries: classification and biomechanical aspects. Unfallchirurg. 2013;116(11):972–8.PubMedCrossRef
5.
go back to reference Routt Jr ML, Nork SE, Mills WJ. Percutaneous fixation of pelvic ring disruptions. Clin Orthop Relat Res. 2000;375:15–29.PubMedCrossRef Routt Jr ML, Nork SE, Mills WJ. Percutaneous fixation of pelvic ring disruptions. Clin Orthop Relat Res. 2000;375:15–29.PubMedCrossRef
6.
go back to reference van den Bosch EW, van Zwienen CM, van Vugt AB. Fluoroscopic positioning of sacroiliac screws in 88 patients. J Trauma. 2002;53(1):44–8.PubMedCrossRef van den Bosch EW, van Zwienen CM, van Vugt AB. Fluoroscopic positioning of sacroiliac screws in 88 patients. J Trauma. 2002;53(1):44–8.PubMedCrossRef
7.
go back to reference Sciulli RL, Daffner RH, Altman DT, Altman GT, Sewecke JJ. CT-guided iliosacral screw placement: technique and clinical experience. AJR Am J Roentgenol. 2007;188(2):W181–92.PubMedCrossRef Sciulli RL, Daffner RH, Altman DT, Altman GT, Sewecke JJ. CT-guided iliosacral screw placement: technique and clinical experience. AJR Am J Roentgenol. 2007;188(2):W181–92.PubMedCrossRef
8.
go back to reference Zwingmann J, Hauschild O, Bode G, Sudkamp NP, Schmal H. Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis. Arch Orthop Trauma Surg. 2013;133(9):1257–65.PubMedCrossRef Zwingmann J, Hauschild O, Bode G, Sudkamp NP, Schmal H. Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis. Arch Orthop Trauma Surg. 2013;133(9):1257–65.PubMedCrossRef
9.
go back to reference Templeman D, Schmidt A, Freese J, Weisman I. Proximity of iliosacral screws to neurovascular structures after internal fixation. Clin Orthop Relat Res. 1996;329:194–8.PubMedCrossRef Templeman D, Schmidt A, Freese J, Weisman I. Proximity of iliosacral screws to neurovascular structures after internal fixation. Clin Orthop Relat Res. 1996;329:194–8.PubMedCrossRef
10.
go back to reference Ziran BH, Smith WR, Towers J, Morgan SJ. Iliosacral screw fixation of the posterior pelvic ring using local anaesthesia and computerised tomography. J Bone Jt Surg Br Vol. 2003;85(3):411–8.CrossRef Ziran BH, Smith WR, Towers J, Morgan SJ. Iliosacral screw fixation of the posterior pelvic ring using local anaesthesia and computerised tomography. J Bone Jt Surg Br Vol. 2003;85(3):411–8.CrossRef
11.
go back to reference Trumm CG, Rubenbauer B, Piltz S, Reiser MF, Hoffmann RT. Screw placement and osteoplasty under computed tomographic-fluoroscopic guidance in a case of advanced metastatic destruction of the iliosacral joint. Cardiovasc Intervent Radiol. 2011;34 Suppl 2:S288–93.PubMedCrossRef Trumm CG, Rubenbauer B, Piltz S, Reiser MF, Hoffmann RT. Screw placement and osteoplasty under computed tomographic-fluoroscopic guidance in a case of advanced metastatic destruction of the iliosacral joint. Cardiovasc Intervent Radiol. 2011;34 Suppl 2:S288–93.PubMedCrossRef
12.
go back to reference Chmelova J, Sir M, Jecminek V. CT-guided percutaneous fixation of pelvic fractures. Case reports. Biomed Pap Med Fac Univ Palacky Olomouc Czechoslovakia. 2005;149(1):177–81.CrossRef Chmelova J, Sir M, Jecminek V. CT-guided percutaneous fixation of pelvic fractures. Case reports. Biomed Pap Med Fac Univ Palacky Olomouc Czechoslovakia. 2005;149(1):177–81.CrossRef
13.
go back to reference Blake-Toker AM, Hawkins L, Nadalo L, Howard D, Arazoza A, Koonsman M, et al. CT-guided percutaneous fixation of sacroiliac fractures in trauma patients. J Trauma. 2001;51(6):1117–21.PubMedCrossRef Blake-Toker AM, Hawkins L, Nadalo L, Howard D, Arazoza A, Koonsman M, et al. CT-guided percutaneous fixation of sacroiliac fractures in trauma patients. J Trauma. 2001;51(6):1117–21.PubMedCrossRef
14.
go back to reference Carlson SK, Bender CE, Classic KL, Zink FE, Quam JP, Ward EM, et al. Benefits and safety of CT fluoroscopy in interventional radiologic procedures. Radiology. 2001;219(2):515–20.PubMedCrossRef Carlson SK, Bender CE, Classic KL, Zink FE, Quam JP, Ward EM, et al. Benefits and safety of CT fluoroscopy in interventional radiologic procedures. Radiology. 2001;219(2):515–20.PubMedCrossRef
15.
go back to reference Paprottka PM, Helmberger T, Reiser MF, Trumm CG. Computed tomography guidance: fluoroscopy and more. Radiologe. 2013;53(11):974–85.PubMedCrossRef Paprottka PM, Helmberger T, Reiser MF, Trumm CG. Computed tomography guidance: fluoroscopy and more. Radiologe. 2013;53(11):974–85.PubMedCrossRef
16.
go back to reference Sarti M, Brehmer WP, Gay SB. Low-dose techniques in CT-guided interventions. Rev Publ Radiol Soc N Am Inc. 2012;32(4):1109–19. discussion 19–20. Sarti M, Brehmer WP, Gay SB. Low-dose techniques in CT-guided interventions. Rev Publ Radiol Soc N Am Inc. 2012;32(4):1109–19. discussion 19–20.
17.
go back to reference Iguchi T, Ogawa K, Doi T, Miyasho K, Munetomo K, Hiraki T, et al. Computed tomography fluoroscopy-guided placement of iliosacral screws in patients with unstable posterior pelvic fractures. Skeletal Radiol. 2010;39(7):701–5.PubMedCrossRef Iguchi T, Ogawa K, Doi T, Miyasho K, Munetomo K, Hiraki T, et al. Computed tomography fluoroscopy-guided placement of iliosacral screws in patients with unstable posterior pelvic fractures. Skeletal Radiol. 2010;39(7):701–5.PubMedCrossRef
18.
go back to reference The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Annals of the ICRP. 2007; 37 (2–4):1–332. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Annals of the ICRP. 2007; 37 (2–4):1–332.
19.
go back to reference Joemai RM, Zweers D, Obermann WR, Geleijns J. Assessment of patient and occupational dose in established and new applications of MDCT fluoroscopy. AJR Am J Roentgenol. 2009;192(4):881–6.PubMedCrossRef Joemai RM, Zweers D, Obermann WR, Geleijns J. Assessment of patient and occupational dose in established and new applications of MDCT fluoroscopy. AJR Am J Roentgenol. 2009;192(4):881–6.PubMedCrossRef
20.
go back to reference Routt Jr ML, Kregor PJ, Simonian PT, Mayo KA. Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma. 1995;9(3):207–14.PubMedCrossRef Routt Jr ML, Kregor PJ, Simonian PT, Mayo KA. Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma. 1995;9(3):207–14.PubMedCrossRef
21.
go back to reference Hinsche AF, Giannoudis PV, Smith RM. Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws. Clin Orthop Relat Res. 2002;395:135–44.PubMedCrossRef Hinsche AF, Giannoudis PV, Smith RM. Fluoroscopy-based multiplanar image guidance for insertion of sacroiliac screws. Clin Orthop Relat Res. 2002;395:135–44.PubMedCrossRef
22.
go back to reference Altman DT, Jones CB, Routt Jr ML. Superior gluteal artery injury during iliosacral screw placement. J Orthop Trauma. 1999;13(3):220–7.PubMedCrossRef Altman DT, Jones CB, Routt Jr ML. Superior gluteal artery injury during iliosacral screw placement. J Orthop Trauma. 1999;13(3):220–7.PubMedCrossRef
23.
go back to reference Ebraheim NA, Rusin JJ, Coombs RJ, Jackson WT, Holiday B. Percutaneous computed-tomography-stabilization of pelvic fractures: preliminary report. J Orthop Trauma. 1987;1(3):197–204.PubMedCrossRef Ebraheim NA, Rusin JJ, Coombs RJ, Jackson WT, Holiday B. Percutaneous computed-tomography-stabilization of pelvic fractures: preliminary report. J Orthop Trauma. 1987;1(3):197–204.PubMedCrossRef
24.
go back to reference Galanski M, Nagel HD, Stamm G. CT radiation exposure risk in Germany. Fortschr Geb. 2001;173(10):R1–66.CrossRef Galanski M, Nagel HD, Stamm G. CT radiation exposure risk in Germany. Fortschr Geb. 2001;173(10):R1–66.CrossRef
25.
go back to reference Brenner DJ, Hall EJ. Computed tomography-an increasing source of radiation exposure. N Engl J Med. 2007;357(22):2277–84.PubMedCrossRef Brenner DJ, Hall EJ. Computed tomography-an increasing source of radiation exposure. N Engl J Med. 2007;357(22):2277–84.PubMedCrossRef
26.
go back to reference Paulson EK, Sheafor DH, Enterline DS, McAdams HP, Yoshizumi TT. CT fluoroscopy-guided interventional procedures: techniques and radiation dose to radiologists. Radiology. 2001;220(1):161–7.PubMedCrossRef Paulson EK, Sheafor DH, Enterline DS, McAdams HP, Yoshizumi TT. CT fluoroscopy-guided interventional procedures: techniques and radiation dose to radiologists. Radiology. 2001;220(1):161–7.PubMedCrossRef
27.
go back to reference Daly B, Templeton PA. Real-time CT fluoroscopy: evolution of an interventional tool. Radiology. 1999;211(2):309–15.PubMedCrossRef Daly B, Templeton PA. Real-time CT fluoroscopy: evolution of an interventional tool. Radiology. 1999;211(2):309–15.PubMedCrossRef
28.
go back to reference Katada K, Kato R, Anno H, Ogura Y, Koga S, Ida Y, et al. Guidance with real-time CT fluoroscopy: early clinical experience. Radiology. 1996;200(3):851–6.PubMed Katada K, Kato R, Anno H, Ogura Y, Koga S, Ida Y, et al. Guidance with real-time CT fluoroscopy: early clinical experience. Radiology. 1996;200(3):851–6.PubMed
29.
go back to reference Silverman SG, Tuncali K, Adams DF, Nawfel RD, Zou KH, Judy PF. CT fluoroscopy-guided abdominal interventions: techniques, results, and radiation exposure. Radiology. 1999;212(3):673–81.PubMedCrossRef Silverman SG, Tuncali K, Adams DF, Nawfel RD, Zou KH, Judy PF. CT fluoroscopy-guided abdominal interventions: techniques, results, and radiation exposure. Radiology. 1999;212(3):673–81.PubMedCrossRef
30.
go back to reference Hohl C, Suess C, Wildberger JE, Honnef D, Das M, Muhlenbruch G, et al. Dose reduction during CT fluoroscopy: phantom study of angular beam modulation. Radiology. 2008;246(2):519–25.PubMedCrossRef Hohl C, Suess C, Wildberger JE, Honnef D, Das M, Muhlenbruch G, et al. Dose reduction during CT fluoroscopy: phantom study of angular beam modulation. Radiology. 2008;246(2):519–25.PubMedCrossRef
Metadata
Title
Technical and clinical outcome of percutaneous CT fluoroscopy-guided screw placement in unstable injuries of the posterior pelvic ring
Authors
Frederik F. Strobl
Sophia M. Haeussler
Philipp M. Paprottka
Ralf-Thorsten Hoffmann
Oliver Pieske
Maximilian F. Reiser
Christoph G. Trumm
Publication date
01-08-2014
Publisher
Springer Berlin Heidelberg
Published in
Skeletal Radiology / Issue 8/2014
Print ISSN: 0364-2348
Electronic ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-014-1890-x

Other articles of this Issue 8/2014

Skeletal Radiology 8/2014 Go to the issue