Skip to main content
Top
Published in: Pediatric Cardiology 4/2005

01-08-2005

Use of Covered Stents in the Management of Coarctation of the Aorta

Authors: C.A.C. Pedra, V.F. Fontes, C.A. Esteves, S.R. Arrieta, S.L.N. Braga, H. Justino, A.M. Kambara, S.M. Moreira, J.E.R. Sousa

Published in: Pediatric Cardiology | Issue 4/2005

Login to get access

Abstract

We report our experience with the use of covered stents for the management of coarctation of the aorta. From December 2001 to March 2004, nine patients (seven males; median age, 31 years; mean weight, 65 ± 15 kg) underwent implantation. Indications included critical or atretic native coarctation (n = 4), patients >50 years of age (n = 2), associated patent ductus arteriosus (n = 1) or adjacent aneurysm (n = 1), and the presence of a circumferential fracture within a previously implanted stent (n = 1). The covered balloon-expandable Cheatham-Platinum stent and the self-expandable stent graft Braile were employed. Adequate implantation was observed in all patients. Gradients were reduced from 54 ± 14 to 3 ± 8 mmHg and the coarctation site increased from 2.4 ± 2.9 to 15.9 ± 4.3 mm. The patent ductus arteriosus was immediately closed and the aneurysm excluded. Two patients >35 years with aneurysmal ascending aorta and metallic aortic prosthesis had aneurysm formation at follow-up, with one undergoing aneurysm exclusion using a Braile stent. Although covered stents are useful in the management of selected patients with coarctation, aneurysm formation may still occur in patients with markers of aortic wall weakness. Refinements in the deployment technique and/or the stent design are needed to eliminate this risk.
Literature
1.
go back to reference Bulbul, ZR, Bruckheimer, E, Love, JC, Fahey, JT, Hellenbrand, WE 1996Implantation of balloon-expandable stents for coarctation of the aorta: implantation data and short-term resultsCathet Cardiovasc Diagn393642PubMed Bulbul, ZR, Bruckheimer, E, Love, JC, Fahey, JT, Hellenbrand, WE 1996Implantation of balloon-expandable stents for coarctation of the aorta: implantation data and short-term resultsCathet Cardiovasc Diagn393642PubMed
2.
go back to reference Cheatham, JP 1999Stents and Amplatzers: what's an interventionalist to do?Cathet Cardiovasc Interv473940 Cheatham, JP 1999Stents and Amplatzers: what's an interventionalist to do?Cathet Cardiovasc Interv473940
3.
go back to reference Cheatham, JP 2001Stenting of coarctation of the aortaCathet Cardiovasc Interv54112125CrossRef Cheatham, JP 2001Stenting of coarctation of the aortaCathet Cardiovasc Interv54112125CrossRef
4.
go back to reference Cheatham, JP 2003NuMED Cheatham platinum stents: role in the management of congenital heart defectsRao, PSKern, MJ eds. Catheter Based DevicesLippincott Williams & WilkinsPhiladelphia353368 Cheatham, JP 2003NuMED Cheatham platinum stents: role in the management of congenital heart defectsRao, PSKern, MJ eds. Catheter Based DevicesLippincott Williams & WilkinsPhiladelphia353368
5.
go back to reference Giovanni, JV 2001Covered stents in the treatment of aortic coarctationJ Interv Cardiol14187190PubMed Giovanni, JV 2001Covered stents in the treatment of aortic coarctationJ Interv Cardiol14187190PubMed
6.
go back to reference Dieter, RS 2001Transluminal endovascular stent grafting of aortic dissections and aneurysms: a concise review of the major trialsClin Cardiol24358363PubMedCrossRef Dieter, RS 2001Transluminal endovascular stent grafting of aortic dissections and aneurysms: a concise review of the major trialsClin Cardiol24358363PubMedCrossRef
7.
go back to reference Duke, C, Rosenthal, E, Qureshi, SA 2003The efficacy and safety of stent redilatation in congenital heart diseaseHeart89905912PubMed Duke, C, Rosenthal, E, Qureshi, SA 2003The efficacy and safety of stent redilatation in congenital heart diseaseHeart89905912PubMed
8.
go back to reference Edwards, WD, Leaf, DS, Edwards, JE 1978Dissecting aortic aneurysm associated with congenital bicuspid aortic valveCirculation5710221025PubMed Edwards, WD, Leaf, DS, Edwards, JE 1978Dissecting aortic aneurysm associated with congenital bicuspid aortic valveCirculation5710221025PubMed
9.
go back to reference Fawzy, ME, Awad, M, Hegazy, H, et al. 2003Long-term follow-up (15-year) results of balloon coarctation angioplasty in the adolescent and adult patientJ Am Coll Cardiol41488CrossRef Fawzy, ME, Awad, M, Hegazy, H,  et al. 2003Long-term follow-up (15-year) results of balloon coarctation angioplasty in the adolescent and adult patientJ Am Coll Cardiol41488CrossRef
10.
go back to reference Fletcher, SE, Nihill, MR, Grifka, RG, O'Laughlin, MP, Mullins, CE 1995Balloon angioplasty of native coarctation of the aorta: midterm follow-up and prognostic factorsJ Am Coll Cardiol25730734PubMedCrossRef Fletcher, SE, Nihill, MR, Grifka, RG, O'Laughlin, MP, Mullins, CE 1995Balloon angioplasty of native coarctation of the aorta: midterm follow-up and prognostic factorsJ Am Coll Cardiol25730734PubMedCrossRef
11.
go back to reference Forbes, T, Matisoff, D, Dysart, J, Aggarwal, S 2003Treatment of coexistent coarctation and aneurysm of the aorta with covered stent in a pediatric patientPediatr Cardiol24289291PubMedCrossRef Forbes, T, Matisoff, D, Dysart, J, Aggarwal, S 2003Treatment of coexistent coarctation and aneurysm of the aorta with covered stent in a pediatric patientPediatr Cardiol24289291PubMedCrossRef
12.
go back to reference Gunn, J, Cleveland, T, Gaines, P 1999Covered stent to treat co-existent coarctation and aneurysm of the aorta in a young manHeart82351PubMed Gunn, J, Cleveland, T, Gaines, P 1999Covered stent to treat co-existent coarctation and aneurysm of the aorta in a young manHeart82351PubMed
13.
go back to reference Hamdan, MA, Maheshwari, S, Fahey, JT, Hellenbrand, WE 2001Endovascular stents for coarctation of the aorta: initial results and intermediate-term follow-upJ Am Coll Cardiol3815181523PubMedCrossRef Hamdan, MA, Maheshwari, S, Fahey, JT, Hellenbrand, WE 2001Endovascular stents for coarctation of the aorta: initial results and intermediate-term follow-upJ Am Coll Cardiol3815181523PubMedCrossRef
14.
go back to reference Harrison, DA, McLaughlin, PR, Lazzam, C, Connelly, M, Benson, LN 2001Endovascular stents in the management of coarctation of the aorta in the adolescent and adult: one year follow upHeart85561566PubMedCrossRef Harrison, DA, McLaughlin, PR, Lazzam, C, Connelly, M, Benson, LN 2001Endovascular stents in the management of coarctation of the aorta in the adolescent and adult: one year follow upHeart85561566PubMedCrossRef
15.
go back to reference Kaemmerer, H 2003Aortic coarctation and interrupted aortic archGatzoulis, MAWebb, GDDaubeney, PEF eds. Diagnosis and Management of Adult Congenital Heart DiseaseChurchill LivingstoneEdinburgh, UK253264 Kaemmerer, H 2003Aortic coarctation and interrupted aortic archGatzoulis, MAWebb, GDDaubeney, PEF eds. Diagnosis and Management of Adult Congenital Heart DiseaseChurchill LivingstoneEdinburgh, UK253264
16.
go back to reference Khan, MS, Moore, JW 2000Treatment of abdominal aortic pseudoaneurysm with covered stents in a pediatric patientCathet Cardiovasc Interv50445448CrossRef Khan, MS, Moore, JW 2000Treatment of abdominal aortic pseudoaneurysm with covered stents in a pediatric patientCathet Cardiovasc Interv50445448CrossRef
17.
go back to reference Koerselnan, J, Vries, H, Jaarsma, W, et al. 2000Balloon angioplasty of coarctation of the aorta: a safe alternative for surgery in adults: immediate and mid-term resultsCathet Cardiovasc Interv502833 Koerselnan, J, Vries, H, Jaarsma, W,  et al. 2000Balloon angioplasty of coarctation of the aorta: a safe alternative for surgery in adults: immediate and mid-term resultsCathet Cardiovasc Interv502833
18.
go back to reference Korkola, SJ, Tchervenkov, CI, Shum-Tim, D, Roy, N 2002Aortic rupture after stenting of a native coarctation in an adultAnn Thorac Surg74936PubMedCrossRef Korkola, SJ, Tchervenkov, CI, Shum-Tim, D, Roy, N 2002Aortic rupture after stenting of a native coarctation in an adultAnn Thorac Surg74936PubMedCrossRef
19.
go back to reference Lindsay, J,Jr 1988Coarctation of the aorta, bicuspid aortic valve and abnormal ascending aortic wallAm J Cardiol61182184PubMedCrossRef Lindsay, J,Jr 1988Coarctation of the aorta, bicuspid aortic valve and abnormal ascending aortic wallAm J Cardiol61182184PubMedCrossRef
20.
go back to reference Magee, AG, Brzezinska-Rajszys, G, Qureshi, SA, et al. 1999Stent implantation for aortic coarctation and recoarctationHeart82600606PubMed Magee, AG, Brzezinska-Rajszys, G, Qureshi, SA,  et al. 1999Stent implantation for aortic coarctation and recoarctationHeart82600606PubMed
21.
go back to reference McCrindle, BW, Jones, TK, Moaow, WR, et al. 1996Acute results of balloon angioplasty of native coarctation versus recurrent aortic obstruction are equivalent. Valvuloplasty and Angioplasty of Congenital Anomalies (VACA) Registry InvestigatorsJ Am Coll Cardiol2818101817PubMed McCrindle, BW, Jones, TK, Moaow, WR,  et al. 1996Acute results of balloon angioplasty of native coarctation versus recurrent aortic obstruction are equivalent. Valvuloplasty and Angioplasty of Congenital Anomalies (VACA) Registry InvestigatorsJ Am Coll Cardiol2818101817PubMed
22.
go back to reference Ovaert, C, McCrindle, BW, Nykanen, D, et al. 2000Balloon angioplasty of native coarctation: clinical outcomes and predictors of successJ Am Coll Cardiol35988996PubMedCrossRef Ovaert, C, McCrindle, BW, Nykanen, D,  et al. 2000Balloon angioplasty of native coarctation: clinical outcomes and predictors of successJ Am Coll Cardiol35988996PubMedCrossRef
23.
go back to reference Palma, JH, Souza, JA, Rodrigues Alves, CM, et al. 2002Self-expandable aortic stent-grafts for treatment of descending aortic dissectionsAnn Thorac Surg7311381141PubMedCrossRef Palma, JH, Souza, JA, Rodrigues Alves, CM,  et al. 2002Self-expandable aortic stent-grafts for treatment of descending aortic dissectionsAnn Thorac Surg7311381141PubMedCrossRef
24.
go back to reference Pedra, CA, Pilla, CB, Braga, SL, Esteves, CA, Fontes, VF 2002Management of a large pseudoaneurysm secondary to balloon dilatation for native coarctation of the aorta with coil occlusion after stent implantation in a childCathet Cardiovasc Interv56262266CrossRef Pedra, CA, Pilla, CB, Braga, SL, Esteves, CA, Fontes, VF 2002Management of a large pseudoaneurysm secondary to balloon dilatation for native coarctation of the aorta with coil occlusion after stent implantation in a childCathet Cardiovasc Interv56262266CrossRef
25.
go back to reference Qureshi, SA, Zubrzycka, M, Brzezinska-Rajszys, G, Kosciesza, A, Ksiazyk, J 2004The use of covered Cheatham-Platinum stents in aortic coarctation and recoarctationCardiol Young145054PubMedCrossRef Qureshi, SA, Zubrzycka, M, Brzezinska-Rajszys, G, Kosciesza, A, Ksiazyk, J 2004The use of covered Cheatham-Platinum stents in aortic coarctation and recoarctationCardiol Young145054PubMedCrossRef
26.
go back to reference Roberts, CS, Roberts, WC 1991Dissection of the aorta associated with congenital malformation of the aortic valveJ Am Coll Cardiol17712716PubMedCrossRef Roberts, CS, Roberts, WC 1991Dissection of the aorta associated with congenital malformation of the aortic valveJ Am Coll Cardiol17712716PubMedCrossRef
27.
go back to reference Rodrigues Alves, CM, da Fonseca, JH, Souza, JA, Camargo Carvalho, AC, Buffolo, E 2002Endovascular treatment of thoracic disease: patient selection and a proposal of a risk scoreAnn Thorac Surg7311431148PubMed Rodrigues Alves, CM, da Fonseca, JH, Souza, JA, Camargo Carvalho, AC, Buffolo, E 2002Endovascular treatment of thoracic disease: patient selection and a proposal of a risk scoreAnn Thorac Surg7311431148PubMed
28.
go back to reference Sadiq, M, Malick, NH, Qureshi, SA 2003Simultaneous treatment of native coarctation of the aorta combined with patent ductus arteriosus using a covered stentCathet Cardiovasc Interv59387390CrossRef Sadiq, M, Malick, NH, Qureshi, SA 2003Simultaneous treatment of native coarctation of the aorta combined with patent ductus arteriosus using a covered stentCathet Cardiovasc Interv59387390CrossRef
29.
go back to reference Schlatmann, TJ, Becker, AE 1977Histologic changes in the normal aging aorta: implications for dissecting aortic aneurysmAm J Cardiol391320PubMed Schlatmann, TJ, Becker, AE 1977Histologic changes in the normal aging aorta: implications for dissecting aortic aneurysmAm J Cardiol391320PubMed
30.
go back to reference Thanopoulos, BD, Hadjinikolaou, L, Konstadopoulou, GN, et al. 2000Stent treatment for coarctation of the aorta: intermediate term follow up and technical considerationsHeart846570PubMedCrossRef Thanopoulos, BD, Hadjinikolaou, L, Konstadopoulou, GN,  et al. 2000Stent treatment for coarctation of the aorta: intermediate term follow up and technical considerationsHeart846570PubMedCrossRef
31.
go back to reference Varma, C, Benson, LN, Butany, J, McLaughlin, PR 2003Aortic dissection after stent dilatation for coarctation of the aorta: a case report and literature reviewCathet Cardiovasc Interv59528535CrossRef Varma, C, Benson, LN, Butany, J, McLaughlin, PR 2003Aortic dissection after stent dilatation for coarctation of the aorta: a case report and literature reviewCathet Cardiovasc Interv59528535CrossRef
Metadata
Title
Use of Covered Stents in the Management of Coarctation of the Aorta
Authors
C.A.C. Pedra
V.F. Fontes
C.A. Esteves
S.R. Arrieta
S.L.N. Braga
H. Justino
A.M. Kambara
S.M. Moreira
J.E.R. Sousa
Publication date
01-08-2005
Publisher
Springer-Verlag
Published in
Pediatric Cardiology / Issue 4/2005
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-004-0814-2

Other articles of this Issue 4/2005

Pediatric Cardiology 4/2005 Go to the issue