Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 9/2011

01-09-2011 | Knee

Computer-assisted gap balancing technique improves outcome in total knee arthroplasty, compared with conventional measured resection technique

Authors: Hee-Nee Pang, Seng-Jin Yeo, Hwei-Chi Chong, Pak-Lin Chin, Johnny Ong, Ngai-Nung Lo

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 9/2011

Login to get access

Abstract

Purpose

The objective of this prospective study was to compare the functional outcome of conventional measured resection technique and computer-assisted gap balancing technique in TKA.

Methods

140 patients were randomized into two groups. The conventional measured resection technique without computer navigation was performed in Group 1 and the computer-assisted gap balancing technique in Group 2. Range of motion, clinical laxity assessment with KT-1000 arthrometer, postoperative radiological films and various functional knee scores were documented at 6 months and 2 years.

Results

At 2 years, there were significantly more patients (five patients, 7%) in the Group 1 with flexion contractures of more than 5° (P = 0.05). There were significantly more outliers in the Group 1 (eight patients, 11%), who demonstrated anterior tibial translation >5 mm, than Group 2 (two patients, 3%) (P = 0.041). The total excursion at 20° was significantly higher in Group 1 at 6 months (P = 0.012) and after 2 years (P = 0.031). Group 2 was able to demonstrate significantly better limb alignment with fewer outliers (more than 3° varus/valgus) than Group 1. At 6-month follow-up, Group 2 demonstrated better outcomes in Function Score (P = 0.040) and Total Oxford Score (P = 0.031). At 2-year review, Group 2 had better outcome in the Total Oxford Score (0.030).

Conclusion

Computer-assisted gap balancing technique was able to achieve more precise soft tissue balance and restoration of limb alignment with better knee scores as compared to the conventional measured resection technique in total knee arthroplasty.

Level of evidence

I.
Literature
1.
go back to reference Bach BR Jr, Warren RF, Flynn WM, Kroll M, Wickiewiecz TL (1990) Arthrometric evaluation of knees that have a torn anterior cruciate ligament. J Bone Joint Surg Am 72:1299–1306PubMed Bach BR Jr, Warren RF, Flynn WM, Kroll M, Wickiewiecz TL (1990) Arthrometric evaluation of knees that have a torn anterior cruciate ligament. J Bone Joint Surg Am 72:1299–1306PubMed
2.
go back to reference Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement. A meta-analysis. J Bone Joint Surg Am 89:261–269PubMedCrossRef Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement. A meta-analysis. J Bone Joint Surg Am 89:261–269PubMedCrossRef
3.
go back to reference Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47PubMed Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47PubMed
4.
go back to reference Bottros J, Gad B, Krebs V, Barsoum WK (2006) Gap balancing in total knee arthroplasty. J Arthroplast 21:11–15CrossRef Bottros J, Gad B, Krebs V, Barsoum WK (2006) Gap balancing in total knee arthroplasty. J Arthroplast 21:11–15CrossRef
5.
go back to reference Chin PL, Yang KY, Yeo SJ, Lo NN (2005) Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplast 20:618–626CrossRef Chin PL, Yang KY, Yeo SJ, Lo NN (2005) Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplast 20:618–626CrossRef
6.
go back to reference Chmell MJ, Scott RD (2008) Balancing the posterior cruciate ligament during cruciate-retaining fixed and mobile-bearing total knee arthroplasty: description of the pull-out lift-off and slide-back tests. J Arthroplast 23:605–608CrossRef Chmell MJ, Scott RD (2008) Balancing the posterior cruciate ligament during cruciate-retaining fixed and mobile-bearing total knee arthroplasty: description of the pull-out lift-off and slide-back tests. J Arthroplast 23:605–608CrossRef
7.
go back to reference Crottet D, Kowal J, Sarfert SA, Maeder T, Bleuler H, Nolte LP, Durselen L (2007) Ligament balancing in TKA: evaluation of a force-sensing device and the influence of patellar eversion and ligament release. J Biomech 40:1709–1715PubMedCrossRef Crottet D, Kowal J, Sarfert SA, Maeder T, Bleuler H, Nolte LP, Durselen L (2007) Ligament balancing in TKA: evaluation of a force-sensing device and the influence of patellar eversion and ligament release. J Biomech 40:1709–1715PubMedCrossRef
8.
go back to reference Daniel DM, Stone ML, Sachs R, Malcom L (1985) Instrumented measurement of anterior knee laxity in patients with acute anterior cruciate ligament disruption. Am J Sports Med 13:401–407PubMedCrossRef Daniel DM, Stone ML, Sachs R, Malcom L (1985) Instrumented measurement of anterior knee laxity in patients with acute anterior cruciate ligament disruption. Am J Sports Med 13:401–407PubMedCrossRef
9.
go back to reference Dawson J, Fitzpatrick R, Murray D, Carr A (1998) Questionnaire on the perceptions of patients about total knee replacement. J Bone Joint Surg Br 80:63–69PubMedCrossRef Dawson J, Fitzpatrick R, Murray D, Carr A (1998) Questionnaire on the perceptions of patients about total knee replacement. J Bone Joint Surg Br 80:63–69PubMedCrossRef
10.
go back to reference Dejour D, Deschamps G, Garotta L, Dejour H (1999) Laxity in posterior cruciate sparing and posterior stabilized total knee prostheses. Clin Orthop Relat Res 364:182–193PubMedCrossRef Dejour D, Deschamps G, Garotta L, Dejour H (1999) Laxity in posterior cruciate sparing and posterior stabilized total knee prostheses. Clin Orthop Relat Res 364:182–193PubMedCrossRef
11.
go back to reference Dennis DA, Komistek RD, Kim RH, Sharma A (2010) Gap balancing versus measured resection technique for total knee arthroplasty. Clin Orthop Relat Res 468:102–107PubMedCrossRef Dennis DA, Komistek RD, Kim RH, Sharma A (2010) Gap balancing versus measured resection technique for total knee arthroplasty. Clin Orthop Relat Res 468:102–107PubMedCrossRef
12.
go back to reference Dutton AQ, Yeo SJ (2009) Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty. Surgical technique. J Bone Joint Surg Am 91:116–130PubMedCrossRef Dutton AQ, Yeo SJ (2009) Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty. Surgical technique. J Bone Joint Surg Am 91:116–130PubMedCrossRef
13.
go back to reference Ek ET, Dowsey MM, Tse LF, Riazi A, Love BR, Stoney JD, Choong PF (2008) Comparison of functional and radiological outcomes after computer-assisted versus conventional total knee arthroplasty: a matched-control retrospective study. J Orthop Surg (Hong Kong) 16:192–196 Ek ET, Dowsey MM, Tse LF, Riazi A, Love BR, Stoney JD, Choong PF (2008) Comparison of functional and radiological outcomes after computer-assisted versus conventional total knee arthroplasty: a matched-control retrospective study. J Orthop Surg (Hong Kong) 16:192–196
14.
go back to reference Ensini A, Catani F, Leardini A, Romagnoli M, Giannini S (2007) Alignments and clinical results in conventional and navigated total knee arthroplasty. Clin Orthop Relat Res 457:156–162PubMed Ensini A, Catani F, Leardini A, Romagnoli M, Giannini S (2007) Alignments and clinical results in conventional and navigated total knee arthroplasty. Clin Orthop Relat Res 457:156–162PubMed
15.
go back to reference Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12PubMed Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12PubMed
16.
go back to reference Fehring TK (2000) Rotational Malalignment of the femoral component in total knee arthroplasty. Clin Orthop Relat Res 380:72–79PubMedCrossRef Fehring TK (2000) Rotational Malalignment of the femoral component in total knee arthroplasty. Clin Orthop Relat Res 380:72–79PubMedCrossRef
17.
go back to reference Forster IW, Warren-Smith CD, Tew M (1989) Is the KT1000 knee ligament arthrometer reliable? J Bone Joint Surg Br 71:843–847PubMed Forster IW, Warren-Smith CD, Tew M (1989) Is the KT1000 knee ligament arthrometer reliable? J Bone Joint Surg Br 71:843–847PubMed
18.
go back to reference Incavo SJ, Johnson CC, Beynnon BD, Howe JG (1994) Posterior cruciate ligament strain biomechanics in total knee arthroplasty. Clin Orthop Relat Res 309:88–93PubMed Incavo SJ, Johnson CC, Beynnon BD, Howe JG (1994) Posterior cruciate ligament strain biomechanics in total knee arthroplasty. Clin Orthop Relat Res 309:88–93PubMed
19.
go back to reference Insall JN (1988) Presidential address to The Knee Society. Choices and compromises in total knee arthroplasty. Clin Orthop Relat Res 226:43–48PubMed Insall JN (1988) Presidential address to The Knee Society. Choices and compromises in total knee arthroplasty. Clin Orthop Relat Res 226:43–48PubMed
20.
go back to reference Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the knee society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the knee society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed
21.
go back to reference Insall JN, Easley ME (2001) Surgical techniques and instrumentation in total knee arthroplasty. In: Insall JN (ed) Surgery of the knee, 3rd edn. Churchill Livingston, Philadelphia, pp 1553–1557 Insall JN, Easley ME (2001) Surgical techniques and instrumentation in total knee arthroplasty. In: Insall JN (ed) Surgery of the knee, 3rd edn. Churchill Livingston, Philadelphia, pp 1553–1557
22.
go back to reference Ishii Y, Matsuda Y, Ishii R, Sakata S, Omori G (2005) Sagittal laxity in vivo after total knee arthroplasty. Arch Orthop Trauma Surg 125:249–253PubMedCrossRef Ishii Y, Matsuda Y, Ishii R, Sakata S, Omori G (2005) Sagittal laxity in vivo after total knee arthroplasty. Arch Orthop Trauma Surg 125:249–253PubMedCrossRef
23.
go back to reference Kim YH, Kim JS, Yoon SH (2008) A recession of posterior cruciate ligament in posterior cruciate-retaining total knee arthrosplasty. J Arthroplast 23:999–1004CrossRef Kim YH, Kim JS, Yoon SH (2008) A recession of posterior cruciate ligament in posterior cruciate-retaining total knee arthrosplasty. J Arthroplast 23:999–1004CrossRef
24.
go back to reference Krackow KA, Mihalko WM (1999) Flexion-extension joint gap changes after lateral structure release for valgus deformity correction in total knee arthroplasty: a cadaveric study. J Arthroplast 14:994–1004CrossRef Krackow KA, Mihalko WM (1999) Flexion-extension joint gap changes after lateral structure release for valgus deformity correction in total knee arthroplasty: a cadaveric study. J Arthroplast 14:994–1004CrossRef
25.
go back to reference Laskin RS (2001) The Genesis total knee prosthesis: a ten-year follow-up study. Clin Orthop Relat Res 388:95–102PubMedCrossRef Laskin RS (2001) The Genesis total knee prosthesis: a ten-year follow-up study. Clin Orthop Relat Res 388:95–102PubMedCrossRef
26.
go back to reference Mahaluxmivala J, Bankes MJ, Nicolai P, Aldam CH, Allen PW (2001) The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplast 16:635–640CrossRef Mahaluxmivala J, Bankes MJ, Nicolai P, Aldam CH, Allen PW (2001) The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplast 16:635–640CrossRef
27.
go back to reference Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236–243PubMedCrossRef Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236–243PubMedCrossRef
28.
go back to reference Murray DW, Fitzpatrick R, Rogers K, Pandit H, Beard DJ, Carr AJ, Dawson J (2007) The use of the Oxford hip and knee scores. J Bone Joint Surg Br 89:1010–1014PubMed Murray DW, Fitzpatrick R, Rogers K, Pandit H, Beard DJ, Carr AJ, Dawson J (2007) The use of the Oxford hip and knee scores. J Bone Joint Surg Br 89:1010–1014PubMed
29.
go back to reference Olcott CW, Scott RD (1999) The Ranawat Award. Femoral component rotation during total knee arthroplasty. Clin Orthop Relat Res 367:39–42PubMedCrossRef Olcott CW, Scott RD (1999) The Ranawat Award. Femoral component rotation during total knee arthroplasty. Clin Orthop Relat Res 367:39–42PubMedCrossRef
30.
go back to reference Ranawat CS, Padgett DE, Ohashi Y (1989) Total knee arthroplasty for patients younger than 55 years. Clin Orthop Relat Res 248:27–33PubMed Ranawat CS, Padgett DE, Ohashi Y (1989) Total knee arthroplasty for patients younger than 55 years. Clin Orthop Relat Res 248:27–33PubMed
31.
go back to reference Ritter MA, Lutgring JD, Davis KE, Berend ME, Pierson JL, Meneghini RM (2007) The role of flexion contracture on outcomes in primary total knee arthroplasty. J Arthroplast 22:1092–1096CrossRef Ritter MA, Lutgring JD, Davis KE, Berend ME, Pierson JL, Meneghini RM (2007) The role of flexion contracture on outcomes in primary total knee arthroplasty. J Arthroplast 22:1092–1096CrossRef
32.
go back to reference Steiner ME, Brown C, Zarins B, Brownstein B, Koval PS, Stone P (1990) Measurement of anterior-posterior displacement of the knee. A comparison of the results with instrumented devices and with clinical examination. J Bone Joint Surg Am 72:1307–1315PubMed Steiner ME, Brown C, Zarins B, Brownstein B, Koval PS, Stone P (1990) Measurement of anterior-posterior displacement of the knee. A comparison of the results with instrumented devices and with clinical examination. J Bone Joint Surg Am 72:1307–1315PubMed
33.
go back to reference Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O (2004) Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 426:180–186PubMedCrossRef Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O (2004) Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 426:180–186PubMedCrossRef
34.
go back to reference Stulberg SD (2003) How accurate is current TKR instrumentation? Clin Orthop Relat Res 416:177–184PubMedCrossRef Stulberg SD (2003) How accurate is current TKR instrumentation? Clin Orthop Relat Res 416:177–184PubMedCrossRef
35.
go back to reference Tew M, Forster IW (1987) Effect of knee replacement on flexion deformity. J Bone Joint Surg Br 69:395–399PubMed Tew M, Forster IW (1987) Effect of knee replacement on flexion deformity. J Bone Joint Surg Br 69:395–399PubMed
36.
go back to reference Tigani D, Sabbioni G, Ben Ayad R, Filanti M, Rani N, Del Piccolo N (2010) Comparison between two computer-assisted total knee arthroplasty: gap-balancing versus measured resection technique. Knee Surg Sports Traumatol Arthrosc 18:1304–1310PubMedCrossRef Tigani D, Sabbioni G, Ben Ayad R, Filanti M, Rani N, Del Piccolo N (2010) Comparison between two computer-assisted total knee arthroplasty: gap-balancing versus measured resection technique. Knee Surg Sports Traumatol Arthrosc 18:1304–1310PubMedCrossRef
37.
go back to reference Tingart M, Lüring C, Bäthis H, Beckmann J, Grifka J, Perlick L (2008) Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? Knee Surg Sports Traumatol Arthrosc 16:44–50PubMedCrossRef Tingart M, Lüring C, Bäthis H, Beckmann J, Grifka J, Perlick L (2008) Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? Knee Surg Sports Traumatol Arthrosc 16:44–50PubMedCrossRef
38.
go back to reference Van Hal CT, van Hellemondt GG, Wymenga AB, Jacobs WC (2007) The anterior-posterior laxity after total knee arthroplasty inserted with a ligament tensor. Knee Surg Sports Traumatol Arthrosc 15:1019–1022PubMedCrossRef Van Hal CT, van Hellemondt GG, Wymenga AB, Jacobs WC (2007) The anterior-posterior laxity after total knee arthroplasty inserted with a ligament tensor. Knee Surg Sports Traumatol Arthrosc 15:1019–1022PubMedCrossRef
39.
go back to reference Viskontas DG, Skrinskas TV, Johnson JA, King GJ, Winemaker MJ, Chess DG (2007) Computer-assisted gap equalization in total knee arthroplasty. J Arthroplast 22(3):334–342CrossRef Viskontas DG, Skrinskas TV, Johnson JA, King GJ, Winemaker MJ, Chess DG (2007) Computer-assisted gap equalization in total knee arthroplasty. J Arthroplast 22(3):334–342CrossRef
40.
go back to reference Ware JE Jr, Sherbourne CD (1992) The MOS 36-item short-form health survey (SF-36). I. Conceptual framework and item selection. Med Care 30:473–483PubMedCrossRef Ware JE Jr, Sherbourne CD (1992) The MOS 36-item short-form health survey (SF-36). I. Conceptual framework and item selection. Med Care 30:473–483PubMedCrossRef
41.
go back to reference Warren PJ, Olanlokun TK, Cobb AG, Walker PS, Iverson BF (1994) Laxity and function in knee replacements. A comparative study of three prosthetic designs. Clin Orthop Relat Res 305:200–208PubMedCrossRef Warren PJ, Olanlokun TK, Cobb AG, Walker PS, Iverson BF (1994) Laxity and function in knee replacements. A comparative study of three prosthetic designs. Clin Orthop Relat Res 305:200–208PubMedCrossRef
42.
go back to reference White SH, O’Connor JJ, Goodfellow JW (1991) Sagittal plane laxity following knee arthroplasty. J Bone Joint Surg Br 73:268–270PubMed White SH, O’Connor JJ, Goodfellow JW (1991) Sagittal plane laxity following knee arthroplasty. J Bone Joint Surg Br 73:268–270PubMed
43.
go back to reference Winemaker MJ (2002) Perfect balance in total knee arthroplasty: the elusive compromise. J Arthroplast 17:2–10CrossRef Winemaker MJ (2002) Perfect balance in total knee arthroplasty: the elusive compromise. J Arthroplast 17:2–10CrossRef
44.
go back to reference Worland RL, Jessup DE, Johnson J (1997) Posterior cruciate recession in total knee arthroplasty. J Arthroplast 12:70–73CrossRef Worland RL, Jessup DE, Johnson J (1997) Posterior cruciate recession in total knee arthroplasty. J Arthroplast 12:70–73CrossRef
Metadata
Title
Computer-assisted gap balancing technique improves outcome in total knee arthroplasty, compared with conventional measured resection technique
Authors
Hee-Nee Pang
Seng-Jin Yeo
Hwei-Chi Chong
Pak-Lin Chin
Johnny Ong
Ngai-Nung Lo
Publication date
01-09-2011
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 9/2011
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-011-1483-3

Other articles of this Issue 9/2011

Knee Surgery, Sports Traumatology, Arthroscopy 9/2011 Go to the issue