Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 8/2007

Open Access 01-08-2007 | Knee

The anterior–posterior laxity after total knee arthroplasty inserted with a ligament tensor

Authors: C. T. H. van Hal, G. G. van Hellemondt, A. B. Wymenga, W. C. H. Jacobs

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 8/2007

Login to get access

Abstract

Goal of this study is to determine the anterior–posterior laxity in 30° of knee flexion for a posterior cruciate retaining total knee arthroplasty with a relative dished insert and implanted with a ligament tensor. Furthermore, the correlation between these AP laxities and the postoperative range of motion (ROM) and postoperative Knee Society Score (KSS) is analysed. Fifty-one balanSys™ total knee arthroplasties were performed in 49 patients between 1998 and 2000. These arthroplasties are analysed with respect to AP laxity (Rolimeter), ROM and KSS with a mean follow-up of 4.6 years. The mean anterior laxity is 2.8 mm with no posterior laxities at all. The average postoperative ROM is 110° with an average KSS of 142. No correlations between AP-laxity and postoperative ROM or between AP-laxity and postoperative KSS are found. A posterior cruciate retaining TKA with a relative dished insert and implanted with a tensor is very stable in the anterior–posterior direction in 30° of knee flexion. This limited laxity does not seem to disadvantage the mean postoperative ROM and KSS, when compared to other TKA studies.
Literature
1.
go back to reference Balasch H, Schiller M, Friebel H, Hoffmann F (1999) Evaluation of anterior knee joint instability with the Rolimeter. A test in comparison with manual assessment, measuring with the KT-1000 arthrometer. Knee Surg Sports Traumatol Arthrosc 7(4):204–208PubMedCrossRef Balasch H, Schiller M, Friebel H, Hoffmann F (1999) Evaluation of anterior knee joint instability with the Rolimeter. A test in comparison with manual assessment, measuring with the KT-1000 arthrometer. Knee Surg Sports Traumatol Arthrosc 7(4):204–208PubMedCrossRef
2.
go back to reference Besson A, Brazier J, Chantelot C, Migaud H, Gougeon F, Duquennoy A (1999) Laxity and functional results of Miller–Galante total knee prosthesis with posterior cruciate ligament sparing after a 6-year follow-up. Rev Chir Orthop Reparatrice Appar Mot 85(8):797–802PubMed Besson A, Brazier J, Chantelot C, Migaud H, Gougeon F, Duquennoy A (1999) Laxity and functional results of Miller–Galante total knee prosthesis with posterior cruciate ligament sparing after a 6-year follow-up. Rev Chir Orthop Reparatrice Appar Mot 85(8):797–802PubMed
3.
go back to reference Cloutier JM, Sabouret P, Deghrar A (1999) Total knee arthroplasty with retention of both cruciate ligaments. A nine to eleven-year follow-up study. J Bone Joint Surg Am 81(5):697–702PubMed Cloutier JM, Sabouret P, Deghrar A (1999) Total knee arthroplasty with retention of both cruciate ligaments. A nine to eleven-year follow-up study. J Bone Joint Surg Am 81(5):697–702PubMed
4.
go back to reference Daniel DM, Malcom LL, Losse G, Stone ML, Sachs R, Burks R (1985) Instrumented measurement of anterior laxity of the knee. J Bone Joint Surg Am 67(5):720–726PubMed Daniel DM, Malcom LL, Losse G, Stone ML, Sachs R, Burks R (1985) Instrumented measurement of anterior laxity of the knee. J Bone Joint Surg Am 67(5):720–726PubMed
5.
go back to reference Ganko A, Engebretsen L, Ozer H (2000) The rolimeter: a new arthrometer compared with the KT-1000. Knee Surg Sports Traumatol Arthrosc 8(1):36–39PubMedCrossRef Ganko A, Engebretsen L, Ozer H (2000) The rolimeter: a new arthrometer compared with the KT-1000. Knee Surg Sports Traumatol Arthrosc 8(1):36–39PubMedCrossRef
6.
go back to reference Hatcher J, Hatcher A, Arbuthnot J, McNicholas M (2005) An investigation to examine the inter-tester and intra-tester reliability of the Rolimeter knee tester, and its sensitivity in identifying knee joint laxity. J Orthop Res 23(6):1399–1403PubMed Hatcher J, Hatcher A, Arbuthnot J, McNicholas M (2005) An investigation to examine the inter-tester and intra-tester reliability of the Rolimeter knee tester, and its sensitivity in identifying knee joint laxity. J Orthop Res 23(6):1399–1403PubMed
7.
go back to reference Ishii Y, Matsuda Y, Ishii R, Sakata S, Omori G (2005) Sagittal laxity in vivo after total knee arthroplasty. Arch Orthop Trauma Surg 125(4):249–253PubMedCrossRef Ishii Y, Matsuda Y, Ishii R, Sakata S, Omori G (2005) Sagittal laxity in vivo after total knee arthroplasty. Arch Orthop Trauma Surg 125(4):249–253PubMedCrossRef
8.
go back to reference Itokazu M, Masuda K, Wada E, Ohno T, Yoshida M, Takatu T (1987) Influence of anteroposterior and mediolateral instability on range of motion after total knee arthroplasty: an ultrasonographic study. Clin Orthop 219:147–157 Itokazu M, Masuda K, Wada E, Ohno T, Yoshida M, Takatu T (1987) Influence of anteroposterior and mediolateral instability on range of motion after total knee arthroplasty: an ultrasonographic study. Clin Orthop 219:147–157
9.
go back to reference Laz PJ, Pal S, Fields A, Petrella AJ, Rullkoetter PJ (2006) Effects of knee simulator loading and alignment variability on predicted implant mechanics: A probabilistic study. J Orthop Res Sep 26 (Epub ahead of print) Laz PJ, Pal S, Fields A, Petrella AJ, Rullkoetter PJ (2006) Effects of knee simulator loading and alignment variability on predicted implant mechanics: A probabilistic study. J Orthop Res Sep 26 (Epub ahead of print)
10.
go back to reference Markolf KL, Kochan A, Amstutz HC (1984) Measurement of knee stiffness and laxity in patients with documented absence of the anterior cruciate ligament. J Bone Joint Surg Am 66(2):242–252PubMed Markolf KL, Kochan A, Amstutz HC (1984) Measurement of knee stiffness and laxity in patients with documented absence of the anterior cruciate ligament. J Bone Joint Surg Am 66(2):242–252PubMed
11.
go back to reference Muellner T, Bugge W, Johansen S, Holtan C, Engebretsen L (2001) Inter- and intratester comparison of the Rolimeter knee tester: effect of tester’s experience and the examination technique. Knee Surg Sports Traumatol Arthrosc 9(5):302–306PubMedCrossRef Muellner T, Bugge W, Johansen S, Holtan C, Engebretsen L (2001) Inter- and intratester comparison of the Rolimeter knee tester: effect of tester’s experience and the examination technique. Knee Surg Sports Traumatol Arthrosc 9(5):302–306PubMedCrossRef
12.
go back to reference Pellengahr C, Jansson V, Durr HR, Refior HJ (1999) Significance of sagittal stability in knee prosthesis implantation–an analysis of 76 cases with unconstrained joint surface replacement. Z Orthop Ihre Grenzgeb 137(4):330–333PubMedCrossRef Pellengahr C, Jansson V, Durr HR, Refior HJ (1999) Significance of sagittal stability in knee prosthesis implantation–an analysis of 76 cases with unconstrained joint surface replacement. Z Orthop Ihre Grenzgeb 137(4):330–333PubMedCrossRef
13.
go back to reference Schuster AJ, McNicholas MJ, Wachtsl SW, Mc Gurthy DW, Jakob RP (2004) A new mechanical testing device for measuring anteroposterior knee laxity. Am J Sports Med 32(7):1731–1735PubMedCrossRef Schuster AJ, McNicholas MJ, Wachtsl SW, Mc Gurthy DW, Jakob RP (2004) A new mechanical testing device for measuring anteroposterior knee laxity. Am J Sports Med 32(7):1731–1735PubMedCrossRef
14.
go back to reference Wada M, Tatsuo H, Kawahara H, Sato M, Baba H (2001) In vivo kinematic analysis of total knee arthroplasty with four different polyethylene designs. Artif Organs 25(1):22–28PubMedCrossRef Wada M, Tatsuo H, Kawahara H, Sato M, Baba H (2001) In vivo kinematic analysis of total knee arthroplasty with four different polyethylene designs. Artif Organs 25(1):22–28PubMedCrossRef
15.
go back to reference Warren PJ, Olanlokun TK, Cobb AG, Walker PS, Iverson BF (1994) Laxity and function in knee replacements. A comparative study of three prosthetic designs. Clin Orthop 305:200–208PubMed Warren PJ, Olanlokun TK, Cobb AG, Walker PS, Iverson BF (1994) Laxity and function in knee replacements. A comparative study of three prosthetic designs. Clin Orthop 305:200–208PubMed
16.
go back to reference Yamakado K, Kitaoka K, Yamada H, Hashiba K, Nakamura R, Tomita K (2003) Influence of stability on range of motion after cruciate-retaining TKA. Arch Orthop Trauma Surg 123(1):1–4PubMed Yamakado K, Kitaoka K, Yamada H, Hashiba K, Nakamura R, Tomita K (2003) Influence of stability on range of motion after cruciate-retaining TKA. Arch Orthop Trauma Surg 123(1):1–4PubMed
Metadata
Title
The anterior–posterior laxity after total knee arthroplasty inserted with a ligament tensor
Authors
C. T. H. van Hal
G. G. van Hellemondt
A. B. Wymenga
W. C. H. Jacobs
Publication date
01-08-2007
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 8/2007
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-007-0333-9

Other articles of this Issue 8/2007

Knee Surgery, Sports Traumatology, Arthroscopy 8/2007 Go to the issue