Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 4/2009

01-04-2009 | Knee

Heterotopic ossification post navigated high tibial osteotomy

Authors: Mustafa Citak, Daniel Kendoff, Padhraig F. O’Loughlin, Andrew D. Pearle

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 4/2009

Login to get access

Abstract

The authors present a case of heterotopic ossification (HO) following a navigated high tibial osteotomy which necessitated a second surgical procedure. There is no evidence in the literature of HO following the use of invasive navigation reference markers. Although osseous reference marker fixation is the current standard technique, this case underscores the need for non-invasive reference markers.
Literature
1.
go back to reference Ahrengart L, Lindgren U (1993) Heterotopic bone after hip arthroplasty. Defining the patient at risk. Clin Orthop Relat Res 293:153–159PubMed Ahrengart L, Lindgren U (1993) Heterotopic bone after hip arthroplasty. Defining the patient at risk. Clin Orthop Relat Res 293:153–159PubMed
2.
go back to reference Anglen JO, Moore KD (1996) Prevention of heterotopic bone formation after acetabular fracture fixation by single-dose radiation therapy: a preliminary report. J Orthop Trauma 10:258–263PubMedCrossRef Anglen JO, Moore KD (1996) Prevention of heterotopic bone formation after acetabular fracture fixation by single-dose radiation therapy: a preliminary report. J Orthop Trauma 10:258–263PubMedCrossRef
3.
go back to reference Blokhuis TJ, Frölke JP (2008) Is radiation superior to indomethacin to prevent heterotopic ossification in acetabular fractures?: a systematic review. Clin Orthop Relat Res [Epub ahead of print] Blokhuis TJ, Frölke JP (2008) Is radiation superior to indomethacin to prevent heterotopic ossification in acetabular fractures?: a systematic review. Clin Orthop Relat Res [Epub ahead of print]
4.
go back to reference Bosse MJ, Poka A, Reinert CM, Ellwanger F, Slawson R, McDevitt ER (1988) Heterotopic ossification as a complication of acetabular fracture. Prophylaxis with low-dose irradiation. J Bone Joint Surg Am 70:1231–1237PubMed Bosse MJ, Poka A, Reinert CM, Ellwanger F, Slawson R, McDevitt ER (1988) Heterotopic ossification as a complication of acetabular fracture. Prophylaxis with low-dose irradiation. J Bone Joint Surg Am 70:1231–1237PubMed
5.
go back to reference Childs HAIII, Cole T, Falkenberg E, Smith JT, Alonso JE, Stannard JP, Spencer SA, Fiveash J, Raben D, Bonner JA, Westfall AO, Kim RY (2000) A prospective evaluation of the timing of postoperative radiotherapy for preventing heterotopic ossification following traumatic acetabular fractures. Int J Radiat Oncol Biol Phys 47:1347–1352PubMed Childs HAIII, Cole T, Falkenberg E, Smith JT, Alonso JE, Stannard JP, Spencer SA, Fiveash J, Raben D, Bonner JA, Westfall AO, Kim RY (2000) A prospective evaluation of the timing of postoperative radiotherapy for preventing heterotopic ossification following traumatic acetabular fractures. Int J Radiat Oncol Biol Phys 47:1347–1352PubMed
6.
go back to reference Citak M, Board TN, Sun Y, Look V, Krettek C, Hufner T, Kendoff D (2007) Reference marker stability in computer aided orthopedic surgery: a biomechanical study in artificial bone and cadavers. Technol Health Care 15:407–414PubMed Citak M, Board TN, Sun Y, Look V, Krettek C, Hufner T, Kendoff D (2007) Reference marker stability in computer aided orthopedic surgery: a biomechanical study in artificial bone and cadavers. Technol Health Care 15:407–414PubMed
7.
go back to reference Fujisawa Y, Masuhara K, Shiomi S (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am 10:585–608PubMed Fujisawa Y, Masuhara K, Shiomi S (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am 10:585–608PubMed
8.
go back to reference Hankemeier S, Hufner T, Wang G, Kendoff D, Zheng G, Richter M, Gosling T, Nolte L, Krettek C (2005) Navigated intraoperative analysis of lower limb alignment. Arch Orthop Trauma Surg 125:531–535PubMedCrossRef Hankemeier S, Hufner T, Wang G, Kendoff D, Zheng G, Richter M, Gosling T, Nolte L, Krettek C (2005) Navigated intraoperative analysis of lower limb alignment. Arch Orthop Trauma Surg 125:531–535PubMedCrossRef
9.
go back to reference Hankemeier S, Hufner T, Wang G, Kendoff D, Zeichen J, Zheng G, Krettek C (2006) Navigated open-wedge high tibial osteotomy: advantages and disadvantages compared to the conventional technique in a cadaver study. Knee Surg Sports Traumatol Arthrosc 14:917–921PubMedCrossRef Hankemeier S, Hufner T, Wang G, Kendoff D, Zeichen J, Zheng G, Krettek C (2006) Navigated open-wedge high tibial osteotomy: advantages and disadvantages compared to the conventional technique in a cadaver study. Knee Surg Sports Traumatol Arthrosc 14:917–921PubMedCrossRef
10.
go back to reference Hernigou P, Medevielle D, Debeyre J, Goutallier D (1987) Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am 69:332–354PubMed Hernigou P, Medevielle D, Debeyre J, Goutallier D (1987) Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am 69:332–354PubMed
11.
go back to reference Kendoff D, Bogojevic A, Citak M, Citak M, Maier C, Maier G, Krettek C, Hufner T (2007) Experimental validation of noninvasive referencing in navigated procedures on long bones. J Orthop Res 25:201–207PubMedCrossRef Kendoff D, Bogojevic A, Citak M, Citak M, Maier C, Maier G, Krettek C, Hufner T (2007) Experimental validation of noninvasive referencing in navigated procedures on long bones. J Orthop Res 25:201–207PubMedCrossRef
12.
go back to reference Kendoff D, Gardner MJ, Krettek C, Hufner T, Citak M (2008) Reference markers in computer aided orthopaedic surgery: rotational stability testings and clinical implications. Arch Orthop Trauma Surg 128:633–638PubMedCrossRef Kendoff D, Gardner MJ, Krettek C, Hufner T, Citak M (2008) Reference markers in computer aided orthopaedic surgery: rotational stability testings and clinical implications. Arch Orthop Trauma Surg 128:633–638PubMedCrossRef
13.
go back to reference Lorenz KJ, Fruhwald S, Maier H (2006) The use of the BrainLAB Kolibri navigation system in endoscopic paranasal sinus surgery under local anaesthesia. An analysis of 35 cases. HNO 54:851–860PubMedCrossRef Lorenz KJ, Fruhwald S, Maier H (2006) The use of the BrainLAB Kolibri navigation system in endoscopic paranasal sinus surgery under local anaesthesia. An analysis of 35 cases. HNO 54:851–860PubMedCrossRef
14.
go back to reference Matta JM, Siebenrock KA (1997) Does indomethacin reduce heterotopic bone formation after operations for acetabular fractures? A prospective randomised study. J Bone Joint Surg Br 79:959–963PubMedCrossRef Matta JM, Siebenrock KA (1997) Does indomethacin reduce heterotopic bone formation after operations for acetabular fractures? A prospective randomised study. J Bone Joint Surg Br 79:959–963PubMedCrossRef
15.
go back to reference McLaren AC (1990) Prophylaxis with indomethacin for heterotopic bone. After open reduction of fractures of the acetabulum. J Bone Joint Surg Am 72:245–247PubMed McLaren AC (1990) Prophylaxis with indomethacin for heterotopic bone. After open reduction of fractures of the acetabulum. J Bone Joint Surg Am 72:245–247PubMed
16.
go back to reference Moed BR, Maxey JW (1993) The effect of indomethacin on heterotopic ossification following acetabular fracture surgery. J Orthop Trauma 7:33–38PubMedCrossRef Moed BR, Maxey JW (1993) The effect of indomethacin on heterotopic ossification following acetabular fracture surgery. J Orthop Trauma 7:33–38PubMedCrossRef
17.
go back to reference Morgan SJ, Jeray KJ, Phieffer LS, Grigsby JH, Bosse MJ, Kellam JF (2001) Attitudes of orthopaedic trauma surgeons regarding current controversies in the management of pelvic and acetabular fractures. J Orthop Trauma 15:526–532PubMedCrossRef Morgan SJ, Jeray KJ, Phieffer LS, Grigsby JH, Bosse MJ, Kellam JF (2001) Attitudes of orthopaedic trauma surgeons regarding current controversies in the management of pelvic and acetabular fractures. J Orthop Trauma 15:526–532PubMedCrossRef
18.
go back to reference Ossendorf C, Fuchs B, Koch P (2006) Femoral stress fracture after computer navigated total knee arthroplasty. Knee 13:397–399PubMedCrossRef Ossendorf C, Fuchs B, Koch P (2006) Femoral stress fracture after computer navigated total knee arthroplasty. Knee 13:397–399PubMedCrossRef
19.
go back to reference Ritter MA, Vaughan RB (1977) Ectopic ossification after total hip arthroplasty. Predisposing factors, frequency, and effect on results. J Bone Joint Surg Am 59:345–351PubMed Ritter MA, Vaughan RB (1977) Ectopic ossification after total hip arthroplasty. Predisposing factors, frequency, and effect on results. J Bone Joint Surg Am 59:345–351PubMed
20.
go back to reference Saragaglia D, Roberts J (2005) Navigated osteotomies around the knee in 170 patients with osteoarthritis secondary to genu varum. Orthopedics 28:s1269–s1274PubMed Saragaglia D, Roberts J (2005) Navigated osteotomies around the knee in 170 patients with osteoarthritis secondary to genu varum. Orthopedics 28:s1269–s1274PubMed
21.
go back to reference Sikorski JM, Blythe MC (2005) Learning the vagaries of computer-assisted total knee replacement. J Bone Joint Surg Br 87:903–910PubMed Sikorski JM, Blythe MC (2005) Learning the vagaries of computer-assisted total knee replacement. J Bone Joint Surg Br 87:903–910PubMed
22.
go back to reference Sundaram NA, Murphy JC (1986) Heterotopic bone formation following total hip arthroplasty in ankylosing spondylitis. Clin Orthop Relat Res 207:223–226PubMed Sundaram NA, Murphy JC (1986) Heterotopic bone formation following total hip arthroplasty in ankylosing spondylitis. Clin Orthop Relat Res 207:223–226PubMed
23.
go back to reference Wagner A, Schicho K, Birkfellner W, Figl M, Seemann R, Konig F, Kainberger F, Ewers R (2002) Quantitative analysis of factors affecting intraoperative precision and stability of optoelectronic and electromagnetic tracking systems. Med Phys 29:905–912PubMedCrossRef Wagner A, Schicho K, Birkfellner W, Figl M, Seemann R, Konig F, Kainberger F, Ewers R (2002) Quantitative analysis of factors affecting intraoperative precision and stability of optoelectronic and electromagnetic tracking systems. Med Phys 29:905–912PubMedCrossRef
24.
go back to reference Wang G, Zheng G, Gruetzner PA, Mueller-Alsbach U, von Recum J, Staubli A, Nolte LP (2005) A fluoroscopy-based surgical navigation system for high tibial osteotomy. Technol Health Care 13:469–483PubMed Wang G, Zheng G, Gruetzner PA, Mueller-Alsbach U, von Recum J, Staubli A, Nolte LP (2005) A fluoroscopy-based surgical navigation system for high tibial osteotomy. Technol Health Care 13:469–483PubMed
Metadata
Title
Heterotopic ossification post navigated high tibial osteotomy
Authors
Mustafa Citak
Daniel Kendoff
Padhraig F. O’Loughlin
Andrew D. Pearle
Publication date
01-04-2009
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 4/2009
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-008-0671-2

Other articles of this Issue 4/2009

Knee Surgery, Sports Traumatology, Arthroscopy 4/2009 Go to the issue