Skip to main content
Top
Published in: Journal of Interventional Cardiac Electrophysiology 2/2009

01-03-2009 | CASE REPORT

Lead extraction: a new effective tool to overcome fibrous binding sites

Authors: Antonio Dello Russo, Roberto Biddau, Gemma Pelargonio, Michela Casella, Antonio Frontera, Antonella Camporeale, Caterina Bisceglia, Giovanni B. Forleo, Claudio Tondo, Paolo Zecchi, Fulvio Bellocci

Published in: Journal of Interventional Cardiac Electrophysiology | Issue 2/2009

Login to get access

Abstract

We report the case of a 50 year-old woman referred for extraction of an infected biventricular implantable cardioverter defibrillator (ICD) who underwent device and leads extraction. Due to adhesions at the level of the subclavian–innominate vein angle, manual traction with locking stylet was ineffective. A new mechanical sheath provided with a stainless steel bladed tip, the Evolution™ Mechanical Dilator Sheath (Cook Medical), was successfully used to complete lead extraction. As far as we know, this is the first report on the use of this new tool; its safety should be ascertained by increasing the number of cases but its simple use and its low cost make the Evolution™ Mechanical Dilator Sheath a new interesting tool that can be added to the instruments available for lead extraction.
Appendix
Available only for authorised users
Literature
1.
go back to reference Zipes, D. P., Camm, A. J., Borggrefe, M., et al. (2006). ACC/AHA/ESC 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: a report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (writing committee to develop Guidelines for Management of Patients with Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death): developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society. Circulation, 114(10), e385–e484.PubMedCrossRef Zipes, D. P., Camm, A. J., Borggrefe, M., et al. (2006). ACC/AHA/ESC 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: a report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (writing committee to develop Guidelines for Management of Patients with Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death): developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society. Circulation, 114(10), e385–e484.PubMedCrossRef
2.
go back to reference Vardas, P. E., Auricchio, A., & el al Blanc, J. J. (2007). ESC 2007 guidelines for cardiac pacing and cardiac resynchronization therapy. The task force for cardiac pacing and cardiac resynchronization therapy of the European Society of Cardiology. Developed in collaboration with the European Heart Rhythm Association. Europace, 9, 959–998.PubMedCrossRef Vardas, P. E., Auricchio, A., & el al Blanc, J. J. (2007). ESC 2007 guidelines for cardiac pacing and cardiac resynchronization therapy. The task force for cardiac pacing and cardiac resynchronization therapy of the European Society of Cardiology. Developed in collaboration with the European Heart Rhythm Association. Europace, 9, 959–998.PubMedCrossRef
3.
go back to reference Rizzello, V., Dello Russo, A., Casella, M., & Biddau, R. (2008). Residual fibrous tissue floating in the right atrium after percutaneous pacemaker lead extraction: An unusual complication early detected by intracardiac echocardiography. International Journal of Cardiology, 127(2), e67–e68.PubMedCrossRef Rizzello, V., Dello Russo, A., Casella, M., & Biddau, R. (2008). Residual fibrous tissue floating in the right atrium after percutaneous pacemaker lead extraction: An unusual complication early detected by intracardiac echocardiography. International Journal of Cardiology, 127(2), e67–e68.PubMedCrossRef
4.
go back to reference Kutalek, S. P. (2004). Pacemaker and defibrillator lead extraction. Current Opinion in Cardiology, 19, 19–22.PubMedCrossRef Kutalek, S. P. (2004). Pacemaker and defibrillator lead extraction. Current Opinion in Cardiology, 19, 19–22.PubMedCrossRef
5.
go back to reference Love, C. J., Wilkoff, B. L., Byrd, C. L., et al. (2000). Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. North American Society of Pacing and Electrophysiology Lead Extraction Conference Faculty. Pacing and Clinical Electrophysiology, 23(Part 1), 544–551.PubMed Love, C. J., Wilkoff, B. L., Byrd, C. L., et al. (2000). Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. North American Society of Pacing and Electrophysiology Lead Extraction Conference Faculty. Pacing and Clinical Electrophysiology, 23(Part 1), 544–551.PubMed
6.
go back to reference Neuzil, P., Taborsky, M., Rezek, Z., et al. (2007). Pacemaker and ICD lead extraction with electrosurgical dissection sheaths and standard transvenous extraction systems: results of a randomized trial. Europace, 9(2), 98–104.PubMedCrossRef Neuzil, P., Taborsky, M., Rezek, Z., et al. (2007). Pacemaker and ICD lead extraction with electrosurgical dissection sheaths and standard transvenous extraction systems: results of a randomized trial. Europace, 9(2), 98–104.PubMedCrossRef
7.
go back to reference Byrd, C. L., Wilkoff, B. L., Love, C. J., et al. (2002). Clinical study of the laser sheath for lead extraction: the total experience in the United States. Pacing and Clinical Electrophysiology, 25, 804–808.PubMedCrossRef Byrd, C. L., Wilkoff, B. L., Love, C. J., et al. (2002). Clinical study of the laser sheath for lead extraction: the total experience in the United States. Pacing and Clinical Electrophysiology, 25, 804–808.PubMedCrossRef
8.
go back to reference Kennergren, C., Bucknall, C. A., Butter, C., et al. (2007). Laser-assisted lead extraction: the European experience. Europace, 9(8), 651–656.PubMedCrossRef Kennergren, C., Bucknall, C. A., Butter, C., et al. (2007). Laser-assisted lead extraction: the European experience. Europace, 9(8), 651–656.PubMedCrossRef
Metadata
Title
Lead extraction: a new effective tool to overcome fibrous binding sites
Authors
Antonio Dello Russo
Roberto Biddau
Gemma Pelargonio
Michela Casella
Antonio Frontera
Antonella Camporeale
Caterina Bisceglia
Giovanni B. Forleo
Claudio Tondo
Paolo Zecchi
Fulvio Bellocci
Publication date
01-03-2009
Publisher
Springer US
Published in
Journal of Interventional Cardiac Electrophysiology / Issue 2/2009
Print ISSN: 1383-875X
Electronic ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-008-9326-y

Other articles of this Issue 2/2009

Journal of Interventional Cardiac Electrophysiology 2/2009 Go to the issue