Videolaryngoscopy versus direct laryngoscopy for double-lumen endotracheal tube intubation in thoracic surgery - a randomised controlled clinical trial

Authors: Joachim Risse, Ann-Kristin Schubert, Thomas Wiesmann, Ansgar Huelshoff, David Stay, Michael Zentgraf, Andreas Kirschbaum, Hinnerk Wulf, Carsten Feldmann, Karl Matteo Meggiolaro

Published in: BMC Anesthesiology | Issue 1/2020

Login to get access

Abstract

Background

Double-lumen tube (DLT) intubation is necessary for thoracic surgery and other operations with the need for lung separation. However, DLT insertion is complex and might result in airway trauma. A new videolaryngoscopy (GVL) with a thin blade might improve the intubation time and reduce complexity as well as iatrogenic airway complications compared to conventional direct laryngoscopy (DL) for DLT intubation.

Methods

A randomised, controlled trial was conducted in 70 patients undergoing elective thoracic surgery using DLT for lung separation. Primary endpoint was time to successful intubation. The secondary endpoints of this study were number of intubation attempts, the assessment of difficulty, any complications during DLT intubation and the incidence of objective trauma of the oropharynx and supraglottic space and intubation-related subjective symptoms.

Results

65 patients were included (DL group [n  =  31], GVL group [n  =  34]). Median intubation time (25th–75th percentiles) in GVL group was 93 s (63–160) versus 74 (58–94) in DL group [p = 0.044]. GVL resulted in significantly improved visualisation of the larynx (Cormack and Lehane grade of 1 in GVL group was 97% vs. 74% in DL Group [p = 0.008]). Endoscopic examinations revealed significant differences in GVL group compared to DL group showing less red-blooded vocal cord [p = 0.004], vocal cord haematoma [p = 0.022] and vocal cord haemorrhage [p = 0.002]. No significant differences regarding the postoperative subjective symptoms of airway were found.

Conclusions

Videolaryngoscopy using the GlideScope®-Titanium shortly prolongs DLT intubation duration compared to direct laryngoscopy but improves the view. Objective intubation trauma but not subjective complaints are reduced.

Trial registration

German Clinical Trial Register DRKS00020978, retrospectively registered on 09. March 2020.
Literature
1.
go back to reference Meggiolaro KM, Wulf H, Feldmann C, Wiesmann T, Schubert AK, Risse J. Airway management for lung separation in thoracic surgery : an update. Anaesthesist. 2018;67(8):555–67.CrossRef Meggiolaro KM, Wulf H, Feldmann C, Wiesmann T, Schubert AK, Risse J. Airway management for lung separation in thoracic surgery : an update. Anaesthesist. 2018;67(8):555–67.CrossRef
2.
go back to reference Defosse J, Schieren M, Böhmer A, von Dossow V, Loop T, Wappler F, et al. A Germany-wide survey on anaesthesia in thoracic surgery. Anaesthesist. 2016;65(6):449–57.CrossRef Defosse J, Schieren M, Böhmer A, von Dossow V, Loop T, Wappler F, et al. A Germany-wide survey on anaesthesia in thoracic surgery. Anaesthesist. 2016;65(6):449–57.CrossRef
3.
go back to reference Zhong T, Wang W, Chen J, Ran L, Story DA. Sore throat or hoarse voice with bronchial blockers or double-lumen tubes for lung isolation: a randomised, prospective trial. Anaesth Intensive Care. 2009;37(3):441–6.PubMed Zhong T, Wang W, Chen J, Ran L, Story DA. Sore throat or hoarse voice with bronchial blockers or double-lumen tubes for lung isolation: a randomised, prospective trial. Anaesth Intensive Care. 2009;37(3):441–6.PubMed
4.
go back to reference Liu H, Jahr JS, Sullivan E, Waters PF. Tracheobronchial rupture after double-lumen endotracheal intubation. J Cardiothorac Vasc Anesth. 2004;18(2):228–33.CrossRef Liu H, Jahr JS, Sullivan E, Waters PF. Tracheobronchial rupture after double-lumen endotracheal intubation. J Cardiothorac Vasc Anesth. 2004;18(2):228–33.CrossRef
5.
go back to reference Chen A, Lai HY, Lin PC, Chen TY, Shyr MH. GlideScope-assisted double-lumen endobronchial tube placement in a patient with an unanticipated difficult airway. J Cardiothorac Vasc Anesth. 2008;22(1):170–2.CrossRef Chen A, Lai HY, Lin PC, Chen TY, Shyr MH. GlideScope-assisted double-lumen endobronchial tube placement in a patient with an unanticipated difficult airway. J Cardiothorac Vasc Anesth. 2008;22(1):170–2.CrossRef
6.
go back to reference Purugganan RV, Jackson TA, Heir JS, Wang H, Cata JP. Video laryngoscopy versus direct laryngoscopy for double-lumen endotracheal tube intubation: a retrospective analysis. J Cardiothorac Vasc Anesth. 2012;26(5):845–8.CrossRef Purugganan RV, Jackson TA, Heir JS, Wang H, Cata JP. Video laryngoscopy versus direct laryngoscopy for double-lumen endotracheal tube intubation: a retrospective analysis. J Cardiothorac Vasc Anesth. 2012;26(5):845–8.CrossRef
8.
go back to reference Russell T, Slinger P, Roscoe A, McRae K, Van Rensburg A. A randomised controlled trial comparing the GlideScope(®) and the Macintosh laryngoscope for double-lumen endobronchial intubation. Anaesthesia. 2013;68(12):1253–8.CrossRef Russell T, Slinger P, Roscoe A, McRae K, Van Rensburg A. A randomised controlled trial comparing the GlideScope(®) and the Macintosh laryngoscope for double-lumen endobronchial intubation. Anaesthesia. 2013;68(12):1253–8.CrossRef
9.
go back to reference Hsu HT, Chou SH, Wu PJ, Tseng KY, Kuo YW, Chou CY, et al. Comparison of the GlideScope® videolaryngoscope and the Macintosh laryngoscope for double-lumen tube intubation. Anaesthesia. 2012;67(4):411–5.CrossRef Hsu HT, Chou SH, Wu PJ, Tseng KY, Kuo YW, Chou CY, et al. Comparison of the GlideScope® videolaryngoscope and the Macintosh laryngoscope for double-lumen tube intubation. Anaesthesia. 2012;67(4):411–5.CrossRef
10.
go back to reference Liu TT, Li L, Wan L, Zhang CH, Yao WL. Videolaryngoscopy vs. Macintosh laryngoscopy for double-lumen tube intubation in thoracic surgery: a systematic review and meta-analysis. Anaesthesia. 2018;73(8):997–1007.CrossRef Liu TT, Li L, Wan L, Zhang CH, Yao WL. Videolaryngoscopy vs. Macintosh laryngoscopy for double-lumen tube intubation in thoracic surgery: a systematic review and meta-analysis. Anaesthesia. 2018;73(8):997–1007.CrossRef
11.
go back to reference Faul F, Erdfelder E, Buchner A, Lang AG. Statistical power analyses using G*power 3.1: tests for correlation and regression analyses. Behav Res Methods. 2009;41(4):1149–60.CrossRef Faul F, Erdfelder E, Buchner A, Lang AG. Statistical power analyses using G*power 3.1: tests for correlation and regression analyses. Behav Res Methods. 2009;41(4):1149–60.CrossRef
12.
go back to reference Faul F, Erdfelder E, Lang AG, Buchner A. G*power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods. 2007;39(2):175–91.CrossRef Faul F, Erdfelder E, Lang AG, Buchner A. G*power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods. 2007;39(2):175–91.CrossRef
13.
go back to reference Lumb AB, Slinger P. Hypoxic pulmonary vasoconstriction: physiology and anesthetic implications. Anesthesiology. 2015;122(4):932–46.CrossRef Lumb AB, Slinger P. Hypoxic pulmonary vasoconstriction: physiology and anesthetic implications. Anesthesiology. 2015;122(4):932–46.CrossRef
14.
go back to reference Fayers P, Aaronson N, Bjordal K, Sullivan M. The EORTC QLQ-C30 Scoring Manual. 3rd ed; 2001. p. 1–33. Fayers P, Aaronson N, Bjordal K, Sullivan M. The EORTC QLQ-C30 Scoring Manual. 3rd ed; 2001. p. 1–33.
15.
go back to reference Yi JHY, Luo A. Comparison of GlideScope video-laryngoscope and Macintosh laryngoscope for double-lumen tube intubation. Chinese J Anesthesiol. 2013;33:201–4. Yi JHY, Luo A. Comparison of GlideScope video-laryngoscope and Macintosh laryngoscope for double-lumen tube intubation. Chinese J Anesthesiol. 2013;33:201–4.
16.
go back to reference Bensghir M, Alaoui H, Azendour H, Drissi M, Elwali A, Meziane M, et al. Faster double-lumen tube intubation with the videolaryngoscope than with a standard laryngoscope. Can J Anaesth. 2010;57(11):980–4.CrossRef Bensghir M, Alaoui H, Azendour H, Drissi M, Elwali A, Meziane M, et al. Faster double-lumen tube intubation with the videolaryngoscope than with a standard laryngoscope. Can J Anaesth. 2010;57(11):980–4.CrossRef
17.
go back to reference Bussières JS, Martel F, Somma J, Morin S, Gagné N. A customized stylet for GlideScope® insertion of double lumen tubes. Can J Anesth. 2012;59(4):424–5.CrossRef Bussières JS, Martel F, Somma J, Morin S, Gagné N. A customized stylet for GlideScope® insertion of double lumen tubes. Can J Anesth. 2012;59(4):424–5.CrossRef
18.
go back to reference Lin W, Li H, Liu W, Cao L, Tan H, Zhong Z. A randomised trial comparing the CEL-100 videolaryngoscope (TM) with the Macintosh laryngoscope blade for insertion of double-lumen tubes. Anaesthesia. 2012;67(7):771–6.CrossRef Lin W, Li H, Liu W, Cao L, Tan H, Zhong Z. A randomised trial comparing the CEL-100 videolaryngoscope (TM) with the Macintosh laryngoscope blade for insertion of double-lumen tubes. Anaesthesia. 2012;67(7):771–6.CrossRef
19.
go back to reference Yao WL, Zhang CH. Macintosh laryngoscopy for double-lumen tube placement - a reply. Anaesthesia. 2015;70(10):1206–8.CrossRef Yao WL, Zhang CH. Macintosh laryngoscopy for double-lumen tube placement - a reply. Anaesthesia. 2015;70(10):1206–8.CrossRef
20.
go back to reference Bustamante S, Parra-Sánchez I, Apostolakis J. Sequential rotation to insert a left double-lumen endotracheal tube using the GlideScope. Can J Anaesth. 2010;57(3):282–3.CrossRef Bustamante S, Parra-Sánchez I, Apostolakis J. Sequential rotation to insert a left double-lumen endotracheal tube using the GlideScope. Can J Anaesth. 2010;57(3):282–3.CrossRef
21.
go back to reference Hernandez AA, Wong DH. Using a Glidescope for intubation with a double lumen endotracheal tube. Can J Anaesth. 2005;52(6):658–9.CrossRef Hernandez AA, Wong DH. Using a Glidescope for intubation with a double lumen endotracheal tube. Can J Anaesth. 2005;52(6):658–9.CrossRef
22.
go back to reference Verelst PL, van Zundert AA. Use of the EZ-blocker for lung separation. J Clin Anesth. 2013;25(2):161–2.CrossRef Verelst PL, van Zundert AA. Use of the EZ-blocker for lung separation. J Clin Anesth. 2013;25(2):161–2.CrossRef
23.
go back to reference Lee RA, van Zundert AA, Maassen RL, Wieringa PA. Forces applied to the maxillary incisors by video laryngoscopes and the Macintosh laryngoscope. Acta Anaesthesiol Scand. 2012;56(2):224–9.CrossRef Lee RA, van Zundert AA, Maassen RL, Wieringa PA. Forces applied to the maxillary incisors by video laryngoscopes and the Macintosh laryngoscope. Acta Anaesthesiol Scand. 2012;56(2):224–9.CrossRef
Metadata
Title
Videolaryngoscopy versus direct laryngoscopy for double-lumen endotracheal tube intubation in thoracic surgery - a randomised controlled clinical trial
Authors
Joachim Risse
Ann-Kristin Schubert
Thomas Wiesmann
Ansgar Huelshoff
David Stay
Michael Zentgraf
Andreas Kirschbaum
Hinnerk Wulf
Carsten Feldmann
Karl Matteo Meggiolaro
Publication date
01-12-2020
Publisher
BioMed Central
Published in
BMC Anesthesiology / Issue 1/2020
Electronic ISSN: 1471-2253
DOI
https://doi.org/10.1186/s12871-020-01067-x

Other articles of this Issue 1/2020

BMC Anesthesiology 1/2020 Go to the issue