Abstract

Airway management in children is associated with anatomical and physiological challenges compared with adults. Pierre Robin sequence (PRS) is a condition characterized by micrognathia, glossoptosis, and cleft palate and related to a difficult airway. Both the Airtraq™ and GlideScope® have never been previously directly compared in PRS. Our aim was to evaluate the performance of these two airway devices in a PRS manikin for ethical and practical reasons. Between April and July 2017, 26, pediatric intensive care clinical fellows or trainees from a tertiary pediatric center were recruited to participate. In this prospective and randomized crossover trial, all participants first set up the Airtraq™ and the GlideScope® and then used these videolaryngoscopes to intubate an AirSim® PRS manikin. Our primary outcome measure was the duration of the successful intubation attempt. Duration of the successful intubation attempt was 18.1 (14.2–34.9 [10.2–51.3]) s for the Airtraq™ compared to 31.1 (18.7–55.6 [6.2–119]) s for the GlideScope® (p = 0.045). Setup time was 50.0 ± 6.9 s for the Airtraq™ and 27.8 ± 8.6 s for the GlideScope® (p < 0.001).
Conclusion: Even though setup time was longer, the characteristics of intubation performance were superior with the Airtraq™ relative to the GlideScope® in an AirSim® PRS manikin.
What is Known:
Several case reports have described the successful use of Airtraq™ to intubate children with Pierre Robin sequence.
The GlideScope® has demonstrated similar rates of first-attempt successful intubation to flexible fiberoptic bronchoscopy in a Pierre Robin sequence manikin.
What is New:
In the hands of pediatric non-airway specialists, the characteristics of intubation performance, including the duration of the successful intubation attempt, are superior with the Airtraq™ compared with the GlideScope® in a Pierre Robin sequence manikin.
Setup time for the Airtraq™ is, however, longer relative to that for the GlideScope®.
Literature
1.
go back to reference Arslan ZI, Turna C, Gumus NE, Toker K, Solak M (2016) Intubation of a paediatric manikin in tongue oedema and face-to-face simulations by novice personnel: a comparison of Glidescope, Airtraq and direct laryngoscopy. Turk J Anaesthesiol Reanim 44:71–75CrossRefPubMedPubMedCentral Arslan ZI, Turna C, Gumus NE, Toker K, Solak M (2016) Intubation of a paediatric manikin in tongue oedema and face-to-face simulations by novice personnel: a comparison of Glidescope, Airtraq and direct laryngoscopy. Turk J Anaesthesiol Reanim 44:71–75CrossRefPubMedPubMedCentral
2.
go back to reference Brambrink AM, Braun U (2005) Airway management in infants and children. Best Pract Res Clin Anaesthesiol 19:675–697CrossRefPubMed Brambrink AM, Braun U (2005) Airway management in infants and children. Best Pract Res Clin Anaesthesiol 19:675–697CrossRefPubMed
3.
go back to reference Desai N, Abdelrazeq S, Chigaru L et al (2018) Airtraq intubation in a newborn with a difficult airway secondary to Pierre Robin sequence. Anaesthesia 73:62 Desai N, Abdelrazeq S, Chigaru L et al (2018) Airtraq intubation in a newborn with a difficult airway secondary to Pierre Robin sequence. Anaesthesia 73:62
4.
go back to reference Dobby N, Black A, Ong KB (2012) Airtraq vs Glidescope – airway management of a pediatric population with a documented difficult airway; Cormack and Lehane Grade III or IV. Pediatr Anesth 22:921CrossRef Dobby N, Black A, Ong KB (2012) Airtraq vs Glidescope – airway management of a pediatric population with a documented difficult airway; Cormack and Lehane Grade III or IV. Pediatr Anesth 22:921CrossRef
5.
go back to reference Fiadjoe JE, Gurnaney H, Dalesio N, Sussman E, Zhao H, Zhang X, Stricker PA (2012) A prospective randomized equivalence trial of the GlideScope Cobalt video laryngoscope to traditional direct laryngoscopy in neonates and infants. Anesthesiology 116:622–628CrossRefPubMed Fiadjoe JE, Gurnaney H, Dalesio N, Sussman E, Zhao H, Zhang X, Stricker PA (2012) A prospective randomized equivalence trial of the GlideScope Cobalt video laryngoscope to traditional direct laryngoscopy in neonates and infants. Anesthesiology 116:622–628CrossRefPubMed
6.
go back to reference Fiadjoe JE, Hirschfeld M, Wu S, Markley J, Gurnaney H, Jawad AF, Stricker P, Kilbaugh T, Ross P, Kovatsis P (2015) A randomized multi-institutional crossover comparison of the GlideScope Cobalt Video laryngoscope to the flexible fiberoptic bronchoscope in a Pierre Robin manikin. Pediatr Anesth 25:801–806CrossRef Fiadjoe JE, Hirschfeld M, Wu S, Markley J, Gurnaney H, Jawad AF, Stricker P, Kilbaugh T, Ross P, Kovatsis P (2015) A randomized multi-institutional crossover comparison of the GlideScope Cobalt Video laryngoscope to the flexible fiberoptic bronchoscope in a Pierre Robin manikin. Pediatr Anesth 25:801–806CrossRef
7.
go back to reference Fonte M, Oulego-Erroz I, Nadkarni L, Sánchez-Santos L, Iglesias-Vásquez A, Rodríguez-Núñez A (2011) A randomized comparison of the GlideScope videolaryngoscope to standard laryngoscopy for intubation by pediatric residents in simulated easy and difficult infant airway scenarios. Pediatr Emerg Care 27:398–402CrossRefPubMed Fonte M, Oulego-Erroz I, Nadkarni L, Sánchez-Santos L, Iglesias-Vásquez A, Rodríguez-Núñez A (2011) A randomized comparison of the GlideScope videolaryngoscope to standard laryngoscopy for intubation by pediatric residents in simulated easy and difficult infant airway scenarios. Pediatr Emerg Care 27:398–402CrossRefPubMed
8.
go back to reference Grunwell JR, Kamat PP, Miksa M, Krishna A, Walson K, Simon D, Krawiec C, Breuer R, Lee JH, Gradidge E, Tarquinio K, Shenoi A, Shults J, Nadkarni V, Nishisaki A, National Emergency Airway Registry for Children (NEAR4KIDS) and the Pediatric Acute Lung Injury and Sepsis (PALISI) Network (2017) Trends and outcomes of video laryngoscope use across PICUs. Pediatr Crit Care Med 18:741–749CrossRefPubMedPubMedCentral Grunwell JR, Kamat PP, Miksa M, Krishna A, Walson K, Simon D, Krawiec C, Breuer R, Lee JH, Gradidge E, Tarquinio K, Shenoi A, Shults J, Nadkarni V, Nishisaki A, National Emergency Airway Registry for Children (NEAR4KIDS) and the Pediatric Acute Lung Injury and Sepsis (PALISI) Network (2017) Trends and outcomes of video laryngoscope use across PICUs. Pediatr Crit Care Med 18:741–749CrossRefPubMedPubMedCentral
9.
go back to reference Holm-Knudsen RJ, Rasmussen LS (2009) Paediatric airway management: basic aspects. Acta Anaesthesiol Scand 53:1–9CrossRefPubMed Holm-Knudsen RJ, Rasmussen LS (2009) Paediatric airway management: basic aspects. Acta Anaesthesiol Scand 53:1–9CrossRefPubMed
10.
go back to reference Isada T, Miwa T, Hiroki K et al (2005) The management of the difficult pediatric airway. Masui 54:490–495PubMed Isada T, Miwa T, Hiroki K et al (2005) The management of the difficult pediatric airway. Masui 54:490–495PubMed
11.
go back to reference Jackson KM, Cook TM (2007) Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices. Anaesthesia 62:388–393CrossRefPubMed Jackson KM, Cook TM (2007) Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices. Anaesthesia 62:388–393CrossRefPubMed
12.
go back to reference Kleine-Brueggeney M, Greif R, Schoettker P, Savoldelli GL, Nabecker S, Theiler LG (2016) Evaluation of six videolaryngoscopes in 720 patients with a simulated difficult airway: a multicentre randomized controlled trial. Br J Anaesth 116:670–679CrossRefPubMed Kleine-Brueggeney M, Greif R, Schoettker P, Savoldelli GL, Nabecker S, Theiler LG (2016) Evaluation of six videolaryngoscopes in 720 patients with a simulated difficult airway: a multicentre randomized controlled trial. Br J Anaesth 116:670–679CrossRefPubMed
13.
go back to reference Knipe M, Armstrong J (2015) Comparison of the GlideScope and Airtraq video-laryngoscopes with direct laryngoscopy in paediatric difficult airways by inexperienced users: a manikin study. Anaesthesia 70:31 Knipe M, Armstrong J (2015) Comparison of the GlideScope and Airtraq video-laryngoscopes with direct laryngoscopy in paediatric difficult airways by inexperienced users: a manikin study. Anaesthesia 70:31
14.
go back to reference Koerner IP, Brambrink AM (2005) Fiberoptic techniques. Best Pract Res Clin Anaesthesiol 19:611–621CrossRefPubMed Koerner IP, Brambrink AM (2005) Fiberoptic techniques. Best Pract Res Clin Anaesthesiol 19:611–621CrossRefPubMed
15.
go back to reference Lee JH, Turner DA, Kamat P (2016) The number of tracheal intubation attempts matters! A prospective multi-institutional pediatric observational study. BMC Pediatr 16:58CrossRefPubMedPubMedCentral Lee JH, Turner DA, Kamat P (2016) The number of tracheal intubation attempts matters! A prospective multi-institutional pediatric observational study. BMC Pediatr 16:58CrossRefPubMedPubMedCentral
16.
go back to reference Levitan RM, Ochroch EA, Kush S et al (1998) Assessment of airway visualization: validation of the percentage of glottic opening (POGO) scale. Acad Emerg Med 5:919–923CrossRefPubMed Levitan RM, Ochroch EA, Kush S et al (1998) Assessment of airway visualization: validation of the percentage of glottic opening (POGO) scale. Acad Emerg Med 5:919–923CrossRefPubMed
17.
go back to reference Li S, Hsieh TC, Rehder KJ (2018) Frequency of desaturation and association with hemodynamic adverse events during tracheal intubations in PICUs. Pediatr Crit Care Med 19:e41–e50CrossRefPubMed Li S, Hsieh TC, Rehder KJ (2018) Frequency of desaturation and association with hemodynamic adverse events during tracheal intubations in PICUs. Pediatr Crit Care Med 19:e41–e50CrossRefPubMed
18.
go back to reference Maharaj CH, Costello JF, Higgins BD, Harte BH, Laffey JG (2006) Learning and performance of tracheal intubation by novice personnel: a comparison of the Airtraq and Macintosh laryngoscope. Anaesthesia 61:671–677CrossRefPubMed Maharaj CH, Costello JF, Higgins BD, Harte BH, Laffey JG (2006) Learning and performance of tracheal intubation by novice personnel: a comparison of the Airtraq and Macintosh laryngoscope. Anaesthesia 61:671–677CrossRefPubMed
19.
go back to reference Nargozian C (2004) The airway in patients with craniofacial abnormalities. Paediatr Anaesth 14:53–59CrossRefPubMed Nargozian C (2004) The airway in patients with craniofacial abnormalities. Paediatr Anaesth 14:53–59CrossRefPubMed
20.
go back to reference Orliaguet GA, Blot RM, Bourdaud N, Egan M, Dogaru E, Salvi N, Gall O, Carli P (2013) Endotracheal intubation with the GlideScope®, the Airtraq®, the McGrath® videolaryngoscope and direct laryngoscopy: a comparative study on an infant manikin. Ann Fr Anesth Reanim 32:844–849CrossRefPubMed Orliaguet GA, Blot RM, Bourdaud N, Egan M, Dogaru E, Salvi N, Gall O, Carli P (2013) Endotracheal intubation with the GlideScope®, the Airtraq®, the McGrath® videolaryngoscope and direct laryngoscopy: a comparative study on an infant manikin. Ann Fr Anesth Reanim 32:844–849CrossRefPubMed
22.
go back to reference Parker MM, Nuthall G, Brown C III et al (2017) Relationship between adverse tracheal intubation associated events and PICU outcomes. Pediatr Crit Care Med 18:310–318CrossRefPubMedPubMedCentral Parker MM, Nuthall G, Brown C III et al (2017) Relationship between adverse tracheal intubation associated events and PICU outcomes. Pediatr Crit Care Med 18:310–318CrossRefPubMedPubMedCentral
23.
go back to reference Rodriguez-Nunez A, Oulego-Erroz I, Perez-Gay L, Cortinas-Diaz J (2010) Comparison of the GlideScope videolaryngoscope to the standard Macintosh for intubation by pediatric residents in simulated child airway scenarios. Pediatr Emerg Care 26:726–729CrossRefPubMed Rodriguez-Nunez A, Oulego-Erroz I, Perez-Gay L, Cortinas-Diaz J (2010) Comparison of the GlideScope videolaryngoscope to the standard Macintosh for intubation by pediatric residents in simulated child airway scenarios. Pediatr Emerg Care 26:726–729CrossRefPubMed
24.
go back to reference Schebesta K, Hupfl M, Rossler B et al (2012) Degrees of reality: airway anatomy of high-fidelity human patient simulators and airway trainers. Anesthesiology 116:1204–1209CrossRefPubMed Schebesta K, Hupfl M, Rossler B et al (2012) Degrees of reality: airway anatomy of high-fidelity human patient simulators and airway trainers. Anesthesiology 116:1204–1209CrossRefPubMed
25.
go back to reference Shah A, Patwa A, Patwa A (2016) Use of Airtraq optical laryngoscope for the intubation in Pierre Robin sequence in a teenage child. Indian J Anaesth 60:295–297CrossRefPubMedPubMedCentral Shah A, Patwa A, Patwa A (2016) Use of Airtraq optical laryngoscope for the intubation in Pierre Robin sequence in a teenage child. Indian J Anaesth 60:295–297CrossRefPubMedPubMedCentral
26.
go back to reference Smereka J (2016) Comparison of Airtraq and Miller laryngoscopes for intubation in patients with inline manual neck stabilization. Am J Emerg Med 34:1721CrossRefPubMed Smereka J (2016) Comparison of Airtraq and Miller laryngoscopes for intubation in patients with inline manual neck stabilization. Am J Emerg Med 34:1721CrossRefPubMed
27.
go back to reference Turkstra TP, Harle CC, Armstrong KP, Armstrong PM, Cherry RA, Hoogstra J, Jones PM (2007) The GlideScope-specific rigid stylet and standard malleable stylet are equally effective for GlideScope use. Can J Anaesth 54:891–896CrossRefPubMed Turkstra TP, Harle CC, Armstrong KP, Armstrong PM, Cherry RA, Hoogstra J, Jones PM (2007) The GlideScope-specific rigid stylet and standard malleable stylet are equally effective for GlideScope use. Can J Anaesth 54:891–896CrossRefPubMed
28.
go back to reference Vlatten A, Soder C (2009) Airtraq optical laryngoscope intubation in a 5-month-old infant with a difficult airway because of Robin Sequence. Paediatr Anaesth 19:699–700CrossRefPubMed Vlatten A, Soder C (2009) Airtraq optical laryngoscope intubation in a 5-month-old infant with a difficult airway because of Robin Sequence. Paediatr Anaesth 19:699–700CrossRefPubMed
29.
go back to reference Vlatten A, Litz S, MacManus B, Launcelott S, Soder C (2012) A comparison of the GlideScope video laryngoscope and standard direct laryngoscopy in children with immobilized cervical spine. Pediatr Emerg Care 28:1317–1320CrossRefPubMed Vlatten A, Litz S, MacManus B, Launcelott S, Soder C (2012) A comparison of the GlideScope video laryngoscope and standard direct laryngoscopy in children with immobilized cervical spine. Pediatr Emerg Care 28:1317–1320CrossRefPubMed
30.
go back to reference White M, Weale N, Nolan J et al (2009) Comparison of the cobalt Glidescope video laryngoscope with conventional laryngoscopy in simulated normal and difficult infant airways. Pediatr Anesth 19:1108–1112CrossRef White M, Weale N, Nolan J et al (2009) Comparison of the cobalt Glidescope video laryngoscope with conventional laryngoscopy in simulated normal and difficult infant airways. Pediatr Anesth 19:1108–1112CrossRef
Metadata
Title
Comparative evaluation of Airtraq™ and GlideScope® videolaryngoscopes for difficult pediatric intubation in a Pierre Robin manikin
Authors
Neel Desai
Mae Johnson
Kat Priddis
Samiran Ray
Linda Chigaru
Publication date
01-07-2019
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Pediatrics / Issue 7/2019
Print ISSN: 0340-6199
Electronic ISSN: 1432-1076
DOI
https://doi.org/10.1007/s00431-019-03396-7

Other articles of this Issue 7/2019

European Journal of Pediatrics 7/2019 Go to the issue