Abstract

Background

The objective of this study was to determine the acute and chronic fixation strengths achieved by fibrin or polyethylene glycol (PEG) sealants to secure biologic mesh at the esophageal hiatus in a porcine model.

Methods

For this study, 32 female domestic pigs were divided into four groups of 8 each. The four groups respectively received acute fibrin sealant, acute PEG sealant, chronic fibrin sealant, and chronic PEG sealant. Laparoscopically, a 5.5 × 8.5-cm piece of Biodesign Surgisis Hiatal Hernia Graft (porcine small intestine submucosa) was oriented with the U-shaped cutout around the gastroesophageal junction and the short axis in the craniocaudal direction to simulate hiatal reinforcement with a biologic mesh. The mesh then was secured with 2 ml of either fibrin sealant or PEG sealant. The pigs in the acute groups were maintained alive for 2 h to allow for complete polymerization of the sealants, and the pigs in the chronic group were maintained alive for 14 days. After the pigs were euthanized, specimens of the mesh–tissue interface were subjected to lap shear testing to determine fixation strength, and hematoxylin and eosin (H&E) stained slides were evaluated for evidence of remodeling.

Results

No significant differences were observed between the acute and chronic fixation strengths or the remodeling characteristics of the two sealants. However, fixation strength increased significantly over time for both types of sealant. Evidence of remodeling also was significantly more pronounced in the chronic specimens than in the acute specimens.

Conclusions

This study demonstrated the feasibility of using fibrin or PEG sealants to secure biologic mesh at the hiatus in a porcine model.
Literature
1.
go back to reference Frantzides CT, Madan AK, Carlson MA, Stavropoulos GP (2002) A prospective, randomized trial of laparoscopic polytetrafluoroethylene (PTFE) patch repair vs simple cruroplasty for large hiatal hernia. Arch Surg 137:649–652PubMedCrossRef Frantzides CT, Madan AK, Carlson MA, Stavropoulos GP (2002) A prospective, randomized trial of laparoscopic polytetrafluoroethylene (PTFE) patch repair vs simple cruroplasty for large hiatal hernia. Arch Surg 137:649–652PubMedCrossRef
2.
go back to reference Hashemi M, Peters JH, Demeester TR, Huprich JE, Quek M, Hagen JA, Crookes PF, Theisen J, DeMeester SR, Sillin LF et al (2000) Laparoscopic repair of large type III hiatal hernia: objective follow-up reveals high recurrence rate. J Am Coll Surg 190:553–560PubMedCrossRef Hashemi M, Peters JH, Demeester TR, Huprich JE, Quek M, Hagen JA, Crookes PF, Theisen J, DeMeester SR, Sillin LF et al (2000) Laparoscopic repair of large type III hiatal hernia: objective follow-up reveals high recurrence rate. J Am Coll Surg 190:553–560PubMedCrossRef
3.
go back to reference Luostarinen M, Rantalainen M, Helve O, Reinikainen P, Isolauri J (1998) Late results of paraoesophageal hiatus hernia repair with fundoplication. Br J Surg 85:272–275PubMedCrossRef Luostarinen M, Rantalainen M, Helve O, Reinikainen P, Isolauri J (1998) Late results of paraoesophageal hiatus hernia repair with fundoplication. Br J Surg 85:272–275PubMedCrossRef
4.
go back to reference Muller-Stich BP, Holzinger F, Kapp T, Klaiber C (2006) Laparoscopic hiatal hernia repair: long-term outcome with the focus on the influence of mesh reinforcement. Surg Endosc 20:380–384PubMedCrossRef Muller-Stich BP, Holzinger F, Kapp T, Klaiber C (2006) Laparoscopic hiatal hernia repair: long-term outcome with the focus on the influence of mesh reinforcement. Surg Endosc 20:380–384PubMedCrossRef
5.
go back to reference Johnson JM, Carbonell AM, Carmody BJ, Jamal MK, Maher JW, Kellum JM, DeMaria EJ (2006) Laparoscopic mesh hiatoplasty for paraesophageal hernias and fundoplications: a critical analysis of the available literature. Surg Endosc 20:362–366PubMedCrossRef Johnson JM, Carbonell AM, Carmody BJ, Jamal MK, Maher JW, Kellum JM, DeMaria EJ (2006) Laparoscopic mesh hiatoplasty for paraesophageal hernias and fundoplications: a critical analysis of the available literature. Surg Endosc 20:362–366PubMedCrossRef
6.
go back to reference Leeder PC, Smith G, Dehn TC (2003) Laparoscopic management of large paraesophageal hiatal hernia. Surg Endosc 17:1372–1375PubMedCrossRef Leeder PC, Smith G, Dehn TC (2003) Laparoscopic management of large paraesophageal hiatal hernia. Surg Endosc 17:1372–1375PubMedCrossRef
7.
go back to reference Stadlhuber RJ, Sherif AE, Mittal SK, Fitzgibbons RJ Jr, Michael BL, Hunter JG, Demeester TR, Swanstrom LL, Daniel SC, Filipi CJ (2009) Mesh complications after prosthetic reinforcement of hiatal closure: a 28-case series. Surg Endosc 23:1219–1226PubMedCrossRef Stadlhuber RJ, Sherif AE, Mittal SK, Fitzgibbons RJ Jr, Michael BL, Hunter JG, Demeester TR, Swanstrom LL, Daniel SC, Filipi CJ (2009) Mesh complications after prosthetic reinforcement of hiatal closure: a 28-case series. Surg Endosc 23:1219–1226PubMedCrossRef
8.
go back to reference Desai KM, Diaz S, Dorward IG, Winslow ER, La Regina MC, Halpin V, Soper NJ (2006) Histologic results 1 year after bioprosthetic repair of paraesophageal hernia in a canine model. Surg Endosc 20:1693–1697PubMedCrossRef Desai KM, Diaz S, Dorward IG, Winslow ER, La Regina MC, Halpin V, Soper NJ (2006) Histologic results 1 year after bioprosthetic repair of paraesophageal hernia in a canine model. Surg Endosc 20:1693–1697PubMedCrossRef
9.
go back to reference Oelschlager BK, Barreca M, Chang L, Pellegrini CA (2003) The use of small intestine submucosa in the repair of paraesophageal hernias: initial observations of a new technique. Am J Surg 186:4–8PubMedCrossRef Oelschlager BK, Barreca M, Chang L, Pellegrini CA (2003) The use of small intestine submucosa in the repair of paraesophageal hernias: initial observations of a new technique. Am J Surg 186:4–8PubMedCrossRef
10.
go back to reference Oelschlager BK, Pellegrini CA, Hunter J, Soper N, Brunt M, Sheppard B, Jobe B, Polissar N, Mitsumori L, Nelson J et al (2006) Biologic prosthesis reduces recurrence after laparoscopic paraesophageal hernia repair: a multicenter, prospective, randomized trial. Ann Surg 244:481–490PubMed Oelschlager BK, Pellegrini CA, Hunter J, Soper N, Brunt M, Sheppard B, Jobe B, Polissar N, Mitsumori L, Nelson J et al (2006) Biologic prosthesis reduces recurrence after laparoscopic paraesophageal hernia repair: a multicenter, prospective, randomized trial. Ann Surg 244:481–490PubMed
11.
go back to reference Oelschlager BK, Pellegrini CA, Hunter J, Brunt LM, Soper N, Sheppard B, Polissar N, Mitsumori L, Rorhmann C, Swanstrom L (2010) Biologic prosthesis to prevent recurrence after laparoscopic paraesophageal hernia repair: long-term follow-up from a multicenter, prospective, randomized trial. In: Presented at the 96th clinical congress of the ACS, Washington, DC, October 2010 Oelschlager BK, Pellegrini CA, Hunter J, Brunt LM, Soper N, Sheppard B, Polissar N, Mitsumori L, Rorhmann C, Swanstrom L (2010) Biologic prosthesis to prevent recurrence after laparoscopic paraesophageal hernia repair: long-term follow-up from a multicenter, prospective, randomized trial. In: Presented at the 96th clinical congress of the ACS, Washington, DC, October 2010
13.
go back to reference Muller-Stich BP, Linke G, Leemann B, Lange J, Zerz A (2006) Cardiac tamponade as a life-threatening complication in antireflux surgery. Am J Surg 191:139–141PubMedCrossRef Muller-Stich BP, Linke G, Leemann B, Lange J, Zerz A (2006) Cardiac tamponade as a life-threatening complication in antireflux surgery. Am J Surg 191:139–141PubMedCrossRef
14.
go back to reference Katkhouda N, Mavor E, Friedlander MH, Mason RJ, Kiyabu M, Grant SW, Achanta K, Kirkman EL, Narayanan K, Essani R (2001) Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair. Ann Surg 233:18–25PubMedCrossRef Katkhouda N, Mavor E, Friedlander MH, Mason RJ, Kiyabu M, Grant SW, Achanta K, Kirkman EL, Narayanan K, Essani R (2001) Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair. Ann Surg 233:18–25PubMedCrossRef
15.
go back to reference Diwan TS, Ujiki MB, Dunst CM, Swanstrom LL (2008) Biomesh placement in laparoscopic repair of paraesophageal hernias. Surg Innov 15:184–187PubMedCrossRef Diwan TS, Ujiki MB, Dunst CM, Swanstrom LL (2008) Biomesh placement in laparoscopic repair of paraesophageal hernias. Surg Innov 15:184–187PubMedCrossRef
16.
go back to reference Wallace DG, Cruise GM, Rhee WM, Schroeder JA, Prior JJ, Ju J, Maroney M, Duronio J, Ngo MH, Estridge T et al (2001) A tissue sealant based on reactive multifunctional polyethylene glycol. J Biomed Mater Res 58:545–555PubMedCrossRef Wallace DG, Cruise GM, Rhee WM, Schroeder JA, Prior JJ, Ju J, Maroney M, Duronio J, Ngo MH, Estridge T et al (2001) A tissue sealant based on reactive multifunctional polyethylene glycol. J Biomed Mater Res 58:545–555PubMedCrossRef
17.
go back to reference Fortelny R, Petter-Puchner A, Glaser K, Keibl C, Gruber-Blum S, Ohlinger W, Redl H (2010) Fibrin sealant (Tisseel) for hiatal mesh fixation in an experimental model in pigs. J Surg Res 162:68–74PubMedCrossRef Fortelny R, Petter-Puchner A, Glaser K, Keibl C, Gruber-Blum S, Ohlinger W, Redl H (2010) Fibrin sealant (Tisseel) for hiatal mesh fixation in an experimental model in pigs. J Surg Res 162:68–74PubMedCrossRef
18.
go back to reference Edelman DS (2008) Fibrin glue fixation of bioactive extracellular matrix mesh compared with soft prolene mesh for laparoscopic hernia repair. Surg Laparosc Endosc Percutan Tech 18:569–572PubMedCrossRef Edelman DS (2008) Fibrin glue fixation of bioactive extracellular matrix mesh compared with soft prolene mesh for laparoscopic hernia repair. Surg Laparosc Endosc Percutan Tech 18:569–572PubMedCrossRef
19.
go back to reference Topart P, Vandenbroucke F, Lozac’h P (2005) Tisseel versus tack staples as mesh fixation in totally extraperitoneal laparoscopic repair of groin hernias: a retrospective analysis. Surg Endosc 19:724–727PubMedCrossRef Topart P, Vandenbroucke F, Lozac’h P (2005) Tisseel versus tack staples as mesh fixation in totally extraperitoneal laparoscopic repair of groin hernias: a retrospective analysis. Surg Endosc 19:724–727PubMedCrossRef
20.
go back to reference Lau H (2005) Fibrin sealant versus mechanical stapling for mesh fixation during endoscopic extraperitoneal inguinal hernioplasty: a randomized prospective trial. Ann Surg 242:670–675PubMedCrossRef Lau H (2005) Fibrin sealant versus mechanical stapling for mesh fixation during endoscopic extraperitoneal inguinal hernioplasty: a randomized prospective trial. Ann Surg 242:670–675PubMedCrossRef
21.
go back to reference Schwab R, Willms A, Kroger A, Becker HP (2006) Less chronic pain following mesh fixation using a fibrin sealant in TEP inguinal hernia repair. Hernia 10:272–277PubMedCrossRef Schwab R, Willms A, Kroger A, Becker HP (2006) Less chronic pain following mesh fixation using a fibrin sealant in TEP inguinal hernia repair. Hernia 10:272–277PubMedCrossRef
22.
go back to reference Lovisetto F, Zonta S, Rota E, Mazzilli M, Bardone M, Bottero L, Faillace G, Longoni M (2007) Use of human fibrin glue (Tissucol) versus staples for mesh fixation in laparoscopic transabdominal preperitoneal hernioplasty: a prospective, randomized study. Ann Surg 245:222–231PubMedCrossRef Lovisetto F, Zonta S, Rota E, Mazzilli M, Bardone M, Bottero L, Faillace G, Longoni M (2007) Use of human fibrin glue (Tissucol) versus staples for mesh fixation in laparoscopic transabdominal preperitoneal hernioplasty: a prospective, randomized study. Ann Surg 245:222–231PubMedCrossRef
23.
go back to reference Ceccarelli G, Casciola L, Pisanelli MC, Bartoli A, Di ZL, Spaziani A, Biancafarina A, Stefanoni M, Patriti A (2008) Comparing fibrin sealant with staples for mesh fixation in laparoscopic transabdominal hernia repair: a case control-study. Surg Endosc 22:668–673PubMedCrossRef Ceccarelli G, Casciola L, Pisanelli MC, Bartoli A, Di ZL, Spaziani A, Biancafarina A, Stefanoni M, Patriti A (2008) Comparing fibrin sealant with staples for mesh fixation in laparoscopic transabdominal hernia repair: a case control-study. Surg Endosc 22:668–673PubMedCrossRef
24.
go back to reference Fortelny RH, Petter-Puchner AH, Glaser KS (2009) Fibrin sealant (Tissucol) for the fixation of hiatal mesh in the repair of giant paraesophageal hernia: a case report. Surg Laparosc Endosc Percutan Tech 19:e91–e94PubMedCrossRef Fortelny RH, Petter-Puchner AH, Glaser KS (2009) Fibrin sealant (Tissucol) for the fixation of hiatal mesh in the repair of giant paraesophageal hernia: a case report. Surg Laparosc Endosc Percutan Tech 19:e91–e94PubMedCrossRef
25.
go back to reference Kanellos D, Moesta KT, Schug-Pass C, Kockerling F (2010) Hiatoplasty reinforcement by means of a lightweight titanized polypropylene mesh fixed with fibrin glue. Zentralbl Chir, e-pub ahead of print, 22 March 2010 Kanellos D, Moesta KT, Schug-Pass C, Kockerling F (2010) Hiatoplasty reinforcement by means of a lightweight titanized polypropylene mesh fixed with fibrin glue. Zentralbl Chir, e-pub ahead of print, 22 March 2010
27.
go back to reference Valentin JE, Badylak JS, McCabe GP, Badylak SF (2006) Extracellular matrix bioscaffolds for orthopaedic applications: a comparative histologic study. J Bone Joint Surg Am 88:2673–2686PubMedCrossRef Valentin JE, Badylak JS, McCabe GP, Badylak SF (2006) Extracellular matrix bioscaffolds for orthopaedic applications: a comparative histologic study. J Bone Joint Surg Am 88:2673–2686PubMedCrossRef
28.
go back to reference Jenkins ED, Melman L, Deeken CR, Greco SC, Frisella M, Matthews BD (2010) Evaluation of fenestrated and nonfenestrated biologic grafts in a porcine model of mature ventral incisional hernia repair. Hernia 14:599–610PubMedCrossRef Jenkins ED, Melman L, Deeken CR, Greco SC, Frisella M, Matthews BD (2010) Evaluation of fenestrated and nonfenestrated biologic grafts in a porcine model of mature ventral incisional hernia repair. Hernia 14:599–610PubMedCrossRef
29.
go back to reference Olmi S, Erba L, Bertolini A, Scaini A, Croce E (2006) Fibrin glue for mesh fixation in laparoscopic transabdominal preperitoneal (TAPP) hernia repair: indications, technique, and outcomes. Surg Endosc 20:1846–1850PubMedCrossRef Olmi S, Erba L, Bertolini A, Scaini A, Croce E (2006) Fibrin glue for mesh fixation in laparoscopic transabdominal preperitoneal (TAPP) hernia repair: indications, technique, and outcomes. Surg Endosc 20:1846–1850PubMedCrossRef
30.
go back to reference Eriksen JR, Bech JI, Linnemann D, Rosenberg J (2008) Laparoscopic intraperitoneal mesh fixation with fibrin sealant (Tisseel) vs titanium tacks: a randomised controlled experimental study in pigs. Hernia 12:483–491PubMedCrossRef Eriksen JR, Bech JI, Linnemann D, Rosenberg J (2008) Laparoscopic intraperitoneal mesh fixation with fibrin sealant (Tisseel) vs titanium tacks: a randomised controlled experimental study in pigs. Hernia 12:483–491PubMedCrossRef
31.
go back to reference Jenkins ED, Melman L, Frisella MM, Deeken CR, Matthews BD (2010) Evaluation of acute fixation strength of absorbable and nonabsorbable barrier-coated mesh secured with fibrin sealant. Hernia 14:505–509PubMedCrossRef Jenkins ED, Melman L, Frisella MM, Deeken CR, Matthews BD (2010) Evaluation of acute fixation strength of absorbable and nonabsorbable barrier-coated mesh secured with fibrin sealant. Hernia 14:505–509PubMedCrossRef
32.
go back to reference Jenkins ED, Melman L, Desai S, Brown SR, Frisella MM, Deeken CR, Matthews BD (2010) Evaluation of intraperitoneal placement of absorbable and nonabsorbable barrier-coated mesh secured with fibrin sealant in a New Zealand White Rabbit model. Surg Endosc 25:604–612PubMedCrossRef Jenkins ED, Melman L, Desai S, Brown SR, Frisella MM, Deeken CR, Matthews BD (2010) Evaluation of intraperitoneal placement of absorbable and nonabsorbable barrier-coated mesh secured with fibrin sealant in a New Zealand White Rabbit model. Surg Endosc 25:604–612PubMedCrossRef
33.
go back to reference Hoffmann NE, Siddiqui SA, Agarwal S, McKellar SH, Kurtz HJ, Gettman MT, Ereth MH (2009) Choice of hemostatic agent influences adhesion formation in a rat cecal adhesion model. J Surg Res 155:77–81PubMedCrossRef Hoffmann NE, Siddiqui SA, Agarwal S, McKellar SH, Kurtz HJ, Gettman MT, Ereth MH (2009) Choice of hemostatic agent influences adhesion formation in a rat cecal adhesion model. J Surg Res 155:77–81PubMedCrossRef
34.
go back to reference Marc HM, Mees U, Hill AC, Egbert B, Coker GT, Estridge TD (2001) Evaluation of a novel synthetic sealant for inhibition of cardiac adhesions and clinical experience in cardiac surgery procedures. Heart Surg Forum 4:204–209 Marc HM, Mees U, Hill AC, Egbert B, Coker GT, Estridge TD (2001) Evaluation of a novel synthetic sealant for inhibition of cardiac adhesions and clinical experience in cardiac surgery procedures. Heart Surg Forum 4:204–209
35.
go back to reference Lindenberg S, Lauritsen JG (1984) Prevention of peritoneal adhesion formation by fibrin sealant: an experimental study in rats. Ann Chir Gynaecol 73:11–13PubMed Lindenberg S, Lauritsen JG (1984) Prevention of peritoneal adhesion formation by fibrin sealant: an experimental study in rats. Ann Chir Gynaecol 73:11–13PubMed
36.
go back to reference Lindenberg S, Steentoft P, Sorensen SS, Olesen HP (1985) Studies on prevention of intraabdominal adhesion formation by fibrin sealant: an experimental study in rats. Acta Chir Scand 151:525–527PubMed Lindenberg S, Steentoft P, Sorensen SS, Olesen HP (1985) Studies on prevention of intraabdominal adhesion formation by fibrin sealant: an experimental study in rats. Acta Chir Scand 151:525–527PubMed
Metadata
Title
Laparoscopic fixation of biologic mesh at the hiatus with fibrin or polyethylene glycol sealant in a porcine model
Authors
Eric D. Jenkins
Sopon Lerdsirisopon
Kevin P. Costello
Lora Melman
Suellen C. Greco
Margaret M. Frisella
Brent D. Matthews
Corey R. Deeken
Publication date
01-10-2011
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 10/2011
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-011-1741-y

Other articles of this Issue 10/2011

Surgical Endoscopy 10/2011 Go to the issue