Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2022

Open Access 01-12-2022 | Knee Osteoarthritis | Research article

Comparison of serum inflammatory indicators and radiographic results in MAKO robotic-assisted versus conventional total knee arthroplasty for knee osteoarthritis: a retrospective study of Chinese patients

Authors: Jia-Zheng Xu, Liang-Liang Li, Jun Fu, Chi Xu, Guo-Qiang Zhang, Wei Chai, Li-Bo Hao, Xiang Li, Ji-Ying Chen

Published in: BMC Musculoskeletal Disorders | Issue 1/2022

Login to get access

Abstract

Background

The purpose of this study was to compare the serum inflammatory indicators and radiographic results of conventional manual total knee arthroplasty (CM-TKA) with those of MAKO-robotic assisted total knee arthroplasty (MA-TKA).

Methods

We retrospectively analysed 65 patients with knee osteoarthritis who underwent unilateral TKA from December 2020 to November 2021 in our department, which included 34 patients who underwent MA-TKA and 31 patients who underwent CM-TKA. The tourniquet time and estimated blood loss (EBL) were compared between the two groups. Knee function was evaluated using range of motion (ROM), functional score and pain score. Leukocytes, C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), interleukin-6 (IL-6), creatine kinase (CK), and neutrophil-to-lymphocyte ratio (NLR) were recorded at 3 time points (preoperative, and on the first and third postoperative days). The hip-knee-ankle angle (HKA) and the femoral and tibial component angles in the coronal and sagittal planes were used for postoperative radiographic evaluation.

Results

The postoperative MA-TKA group had less EBL (496.9 ± 257.8 vs. 773.0 ± 301.3 ml, p < 0.001). There was no significant difference in knee function scores at 6 weeks postoperatively (p > 0.05). IL-6 levels were significantly lower in the MA-TKA group on the 1st postoperative day (11.4 (5.2, 21.0) vs. 24.6 (86.3, 170.8), p = 0.031). This difference in inflammatory indices became more pronounced at 72 hours after the operation because CRP, ESR, IL-6, and CK values were significantly lower in the MA-TKA group on the 3rd postoperative day (72 h) (p < 0.05). Postoperative radiographic examinations performed 2 days after the MA-TKA group suggested that only 2 cases of HKA had outlier values, which was remarkably better than the 12 cases found in the CM-TKA group (5.9% vs. 38.7%, p < 0.001). The frontal femoral component was significantly closer to the expected value of 90° in the MA-TKA group (90.9 (90.5, 92.3) vs. 92.4 (91.3, 93.7), p = 0.031). The remaining imaging evaluation parameters were not significantly different between the two groups (p > 0.05).

Conclusions

In Chinese patients with OA, there was a milder systemic inflammatory response in the early postoperative period after MA-TKA compared to that of CM-TKA, as well as better radiographic outcomes. However, the tourniquet time was prolonged, and no advantages were observed in terms of functional score or pain score in the short-term follow-up.
Literature
1.
go back to reference Deckey DG, Rosenow CS, Verhey JT, Brinkman JC, Mayfield CK, Clarke HD, et al. Robotic-assisted total knee arthroplasty improves accuracy and precision compared to conventional techniques. Bone Joint J. 2021;103-b(6 Supple A):74–80.CrossRef Deckey DG, Rosenow CS, Verhey JT, Brinkman JC, Mayfield CK, Clarke HD, et al. Robotic-assisted total knee arthroplasty improves accuracy and precision compared to conventional techniques. Bone Joint J. 2021;103-b(6 Supple A):74–80.CrossRef
2.
go back to reference Kaneko T, Igarashi T, Takada K, Yoshizawa S, Ikegami H, Musha Y. Robotic-assisted total knee arthroplasty improves the outlier of rotational alignment of the tibial prosthesis using 3DCT measurements. Knee. 2021;31:64–76.CrossRef Kaneko T, Igarashi T, Takada K, Yoshizawa S, Ikegami H, Musha Y. Robotic-assisted total knee arthroplasty improves the outlier of rotational alignment of the tibial prosthesis using 3DCT measurements. Knee. 2021;31:64–76.CrossRef
3.
go back to reference Liow MH, Xia Z, Wong MK, Tay KJ, Yeo SJ, Chin PL. Robot-assisted total knee arthroplasty accurately restores the joint line and mechanical axis. A prospective randomised study. J Arthroplast. 2014;29(12):2373–7.CrossRef Liow MH, Xia Z, Wong MK, Tay KJ, Yeo SJ, Chin PL. Robot-assisted total knee arthroplasty accurately restores the joint line and mechanical axis. A prospective randomised study. J Arthroplast. 2014;29(12):2373–7.CrossRef
4.
go back to reference Cip J, Obwegeser F, Benesch T, Bach C, Ruckenstuhl P, Martin A. Twelve-year follow-up of navigated computer-assisted versus conventional Total knee Arthroplasty: a prospective randomized comparative trial. J Arthroplast. 2018;33(5):1404–11.CrossRef Cip J, Obwegeser F, Benesch T, Bach C, Ruckenstuhl P, Martin A. Twelve-year follow-up of navigated computer-assisted versus conventional Total knee Arthroplasty: a prospective randomized comparative trial. J Arthroplast. 2018;33(5):1404–11.CrossRef
5.
go back to reference Hamilton DA, Ononuju U, Nowak C, Chen C, Darwiche H. Differences in immediate postoperative outcomes between robotic-assisted TKA and conventional TKA. Arthroplast Today. 2021;8:57–62.CrossRef Hamilton DA, Ononuju U, Nowak C, Chen C, Darwiche H. Differences in immediate postoperative outcomes between robotic-assisted TKA and conventional TKA. Arthroplast Today. 2021;8:57–62.CrossRef
6.
go back to reference Zak SG, Yeroushalmi D, Tang A, Meftah M, Schnaser E, Schwarzkopf R. The use of navigation or robotic-assisted Technology in Total Knee Arthroplasty Does not Reduce Postoperative Pain. J Knee Surg. 2021. Zak SG, Yeroushalmi D, Tang A, Meftah M, Schnaser E, Schwarzkopf R. The use of navigation or robotic-assisted Technology in Total Knee Arthroplasty Does not Reduce Postoperative Pain. J Knee Surg. 2021.
7.
go back to reference Kayani B, Tahmassebi J, Ayuob A, Konan S, Oussedik S, Haddad FS. A prospective randomized controlled trial comparing the systemic inflammatory response in conventional jig-based total knee arthroplasty versus robotic-arm assisted total knee arthroplasty. Bone Joint J. 2021;103-b(1):113–22.CrossRef Kayani B, Tahmassebi J, Ayuob A, Konan S, Oussedik S, Haddad FS. A prospective randomized controlled trial comparing the systemic inflammatory response in conventional jig-based total knee arthroplasty versus robotic-arm assisted total knee arthroplasty. Bone Joint J. 2021;103-b(1):113–22.CrossRef
8.
go back to reference Huang ZY, Huang Q, Wang LY, Lei YT, Xu H, Shen B, et al. Normal trajectory of Interleukin-6 and C-reactive protein in the perioperative period of total knee arthroplasty under an enhanced recovery after surgery scenario. BMC Musculoskelet Disord. 2020;21(1):264.CrossRef Huang ZY, Huang Q, Wang LY, Lei YT, Xu H, Shen B, et al. Normal trajectory of Interleukin-6 and C-reactive protein in the perioperative period of total knee arthroplasty under an enhanced recovery after surgery scenario. BMC Musculoskelet Disord. 2020;21(1):264.CrossRef
9.
go back to reference Gandhi R, Razak F, Mahomed NN. Ethnic differences in the relationship between obesity and joint pain and function in a joint arthroplasty population. J Rheumatol. 2008;35(9):1874–7.PubMed Gandhi R, Razak F, Mahomed NN. Ethnic differences in the relationship between obesity and joint pain and function in a joint arthroplasty population. J Rheumatol. 2008;35(9):1874–7.PubMed
10.
go back to reference Chen H, Wu J, Wang Z, Wu Y, Wu T, Wu Y, et al. Trends and patterns of knee osteoarthritis in China: a longitudinal study of 17.7 million adults from 2008 to 2017. Int J Environ Res Public Health. 2021;18(16):8864. Chen H, Wu J, Wang Z, Wu Y, Wu T, Wu Y, et al. Trends and patterns of knee osteoarthritis in China: a longitudinal study of 17.7 million adults from 2008 to 2017. Int J Environ Res Public Health. 2021;18(16):8864.
11.
go back to reference Li K, Saffarini M, Valluy J, Desseroit MC, Morvan Y, Telmon N, et al. Sexual and ethnic polymorphism render prosthetic overhang and under-coverage inevitable using off-the shelf TKA implants. Knee Surg Sports Traumatol Arthrosc. 2019;27(7):2130–9.CrossRef Li K, Saffarini M, Valluy J, Desseroit MC, Morvan Y, Telmon N, et al. Sexual and ethnic polymorphism render prosthetic overhang and under-coverage inevitable using off-the shelf TKA implants. Knee Surg Sports Traumatol Arthrosc. 2019;27(7):2130–9.CrossRef
12.
go back to reference Aggarwal AK, Singh N, Sudesh P. Topical vs intravenous Tranexamic acid in reducing blood loss after bilateral Total knee Arthroplasty: a prospective study. J Arthroplast. 2016;31(7):1442–8.CrossRef Aggarwal AK, Singh N, Sudesh P. Topical vs intravenous Tranexamic acid in reducing blood loss after bilateral Total knee Arthroplasty: a prospective study. J Arthroplast. 2016;31(7):1442–8.CrossRef
13.
go back to reference Morrell AT, Layon DR, Scott MJ, Kates SL, Golladay GJ, Patel NK. Enhanced recovery after primary Total hip and knee Arthroplasty: a systematic review. J Bone Joint Surg Am. 2021;103(20):1938–47.CrossRef Morrell AT, Layon DR, Scott MJ, Kates SL, Golladay GJ, Patel NK. Enhanced recovery after primary Total hip and knee Arthroplasty: a systematic review. J Bone Joint Surg Am. 2021;103(20):1938–47.CrossRef
14.
go back to reference Westby MD, Brittain A, Backman CL. Expert consensus on best practices for post-acute rehabilitation after total hip and knee arthroplasty: a Canada and United States Delphi study. Arthritis Care Res. 2014;66(3):411–23.CrossRef Westby MD, Brittain A, Backman CL. Expert consensus on best practices for post-acute rehabilitation after total hip and knee arthroplasty: a Canada and United States Delphi study. Arthritis Care Res. 2014;66(3):411–23.CrossRef
15.
go back to reference Youm T, Maurer SG, Stuchin SA. Postoperative management after total hip and knee arthroplasty. J Arthroplast. 2005;20(3):322–4.CrossRef Youm T, Maurer SG, Stuchin SA. Postoperative management after total hip and knee arthroplasty. J Arthroplast. 2005;20(3):322–4.CrossRef
16.
go back to reference Gross JB. Estimating allowable blood loss: corrected for dilution. 1983;58(3):277–80. Gross JB. Estimating allowable blood loss: corrected for dilution. 1983;58(3):277–80.
17.
go back to reference Ensini A, Catani F, Leardini A, Romagnoli M, Giannini S. Alignments and clinical results in conventional and navigated total knee arthroplasty. Clin Orthop Relat Res. 2007;457:156–62.CrossRef Ensini A, Catani F, Leardini A, Romagnoli M, Giannini S. Alignments and clinical results in conventional and navigated total knee arthroplasty. Clin Orthop Relat Res. 2007;457:156–62.CrossRef
18.
go back to reference Vermue H, Lambrechts J, Tampere T, Arnout N, Auvinet E, Victor J. How should we evaluate robotics in the operating theatre? Bone Joint J. 2020;102-b(4):407–13.CrossRef Vermue H, Lambrechts J, Tampere T, Arnout N, Auvinet E, Victor J. How should we evaluate robotics in the operating theatre? Bone Joint J. 2020;102-b(4):407–13.CrossRef
19.
go back to reference Wang K, Ni S, Li Z, Zhong Q, Li R, Li H, et al. The effects of tourniquet use in total knee arthroplasty: a randomized, controlled trial. Knee Surg Sports Traumatol Arthrosc. 2017;25(9):2849–57.CrossRef Wang K, Ni S, Li Z, Zhong Q, Li R, Li H, et al. The effects of tourniquet use in total knee arthroplasty: a randomized, controlled trial. Knee Surg Sports Traumatol Arthrosc. 2017;25(9):2849–57.CrossRef
20.
go back to reference Chauhan SK, Scott RG, Breidahl W, Beaver RJ. Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Joint Surgery Br Vol. 2004;86(3):372–7.CrossRef Chauhan SK, Scott RG, Breidahl W, Beaver RJ. Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Joint Surgery Br Vol. 2004;86(3):372–7.CrossRef
21.
go back to reference Millar NL, Deakin AH, Millar LL, Kinnimonth AW, Picard F. Blood loss following total knee replacement in the morbidly obese: effects of computer navigation. Knee. 2011;18(2):108–12.CrossRef Millar NL, Deakin AH, Millar LL, Kinnimonth AW, Picard F. Blood loss following total knee replacement in the morbidly obese: effects of computer navigation. Knee. 2011;18(2):108–12.CrossRef
22.
go back to reference Tang Q, Shang P, Zheng G, Xu HZ, Liu HX. Extramedullary versus intramedullary femoral alignment technique in total knee arthroplasty: a meta-analysis of randomized controlled trials. J Orthop Surg Res. 2017;12(1):82.CrossRef Tang Q, Shang P, Zheng G, Xu HZ, Liu HX. Extramedullary versus intramedullary femoral alignment technique in total knee arthroplasty: a meta-analysis of randomized controlled trials. J Orthop Surg Res. 2017;12(1):82.CrossRef
23.
go back to reference Kayani B, Konan S, Tahmassebi J, Pietrzak JRT, Haddad FS. Robotic-arm assisted total knee arthroplasty is associated with improved early functional recovery and reduced time to hospital discharge compared with conventional jig-based total knee arthroplasty: a prospective cohort study. Bone Joint J. 2018;100-b(7):930–7.CrossRef Kayani B, Konan S, Tahmassebi J, Pietrzak JRT, Haddad FS. Robotic-arm assisted total knee arthroplasty is associated with improved early functional recovery and reduced time to hospital discharge compared with conventional jig-based total knee arthroplasty: a prospective cohort study. Bone Joint J. 2018;100-b(7):930–7.CrossRef
24.
go back to reference Marchand KB, Moody R, Scholl LY, Bhowmik-Stoker M, Taylor KB, Mont MA, et al. Results of robotic-assisted versus manual Total knee Arthroplasty at 2-year follow-up. J Knee Surg. 2021. Marchand KB, Moody R, Scholl LY, Bhowmik-Stoker M, Taylor KB, Mont MA, et al. Results of robotic-assisted versus manual Total knee Arthroplasty at 2-year follow-up. J Knee Surg. 2021.
25.
go back to reference Singh V, Fiedler B, Simcox T, Aggarwal VK, Schwarzkopf R, Meftah M. Does the use of intraoperative technology yield superior patient outcomes following Total knee Arthroplasty? J Arthroplast. 2021;36(7s):S227–s232.CrossRef Singh V, Fiedler B, Simcox T, Aggarwal VK, Schwarzkopf R, Meftah M. Does the use of intraoperative technology yield superior patient outcomes following Total knee Arthroplasty? J Arthroplast. 2021;36(7s):S227–s232.CrossRef
26.
go back to reference Zhang J, Matzko CN, Sawires A, Ehiorobo JO, Mont MA, Hepinstall MS. Adoption of robotic-arm-assisted Total knee Arthroplasty is associated with decreased use of articular constraint and manipulation under anesthesia compared to a manual approach. J Knee Surg. 2021. Zhang J, Matzko CN, Sawires A, Ehiorobo JO, Mont MA, Hepinstall MS. Adoption of robotic-arm-assisted Total knee Arthroplasty is associated with decreased use of articular constraint and manipulation under anesthesia compared to a manual approach. J Knee Surg. 2021.
27.
go back to reference Zhao HY, Yeersheng R, Kang XW, Xia YY, Kang PD, Wang WJ. The effect of tourniquet uses on total blood loss, early function, and pain after primary total knee arthroplasty: a prospective, randomized controlled trial. Bone Joint Res. 2020;9(6):322–32.CrossRef Zhao HY, Yeersheng R, Kang XW, Xia YY, Kang PD, Wang WJ. The effect of tourniquet uses on total blood loss, early function, and pain after primary total knee arthroplasty: a prospective, randomized controlled trial. Bone Joint Res. 2020;9(6):322–32.CrossRef
28.
go back to reference Aktaş E, Atay Ç, Deveci MA, Arıkan M, Toğral G, Yıldırım A. Impact of oxidative stress on early postoperative knee function and muscle injury biochemical markers: is it possible to create an ischemic preconditioning effect in sequential ischemic surgical procedures? Acta Orthop Traumatol Turc. 2015;49(4):387–93.PubMed Aktaş E, Atay Ç, Deveci MA, Arıkan M, Toğral G, Yıldırım A. Impact of oxidative stress on early postoperative knee function and muscle injury biochemical markers: is it possible to create an ischemic preconditioning effect in sequential ischemic surgical procedures? Acta Orthop Traumatol Turc. 2015;49(4):387–93.PubMed
29.
go back to reference Batailler C, Fernandez A, Swan J, Servien E, Haddad FS, Catani F, et al. MAKO CT-based robotic arm-assisted system is a reliable procedure for total knee arthroplasty: a systematic review. Knee Surg Sports Traumatol Arthrosc. 2021;29(11):3585–98. Batailler C, Fernandez A, Swan J, Servien E, Haddad FS, Catani F, et al. MAKO CT-based robotic arm-assisted system is a reliable procedure for total knee arthroplasty: a systematic review. Knee Surg Sports Traumatol Arthrosc. 2021;29(11):3585–98.
30.
go back to reference Elliott J, Shatrov J, Fritsch B, Parker D. Robotic-assisted knee arthroplasty: an evolution in progress. A concise review of the available systems and the data supporting them. Arch Orthop Trauma Surg. 2021;141(12):2099–117.CrossRef Elliott J, Shatrov J, Fritsch B, Parker D. Robotic-assisted knee arthroplasty: an evolution in progress. A concise review of the available systems and the data supporting them. Arch Orthop Trauma Surg. 2021;141(12):2099–117.CrossRef
31.
go back to reference Harvey WF, Niu J, Zhang Y, McCree PI, Felson DT, Nevitt M, et al. Knee alignment differences between Chinese and Caucasian subjects without osteoarthritis. Ann Rheum Dis. 2008;67(11):1524–8.CrossRef Harvey WF, Niu J, Zhang Y, McCree PI, Felson DT, Nevitt M, et al. Knee alignment differences between Chinese and Caucasian subjects without osteoarthritis. Ann Rheum Dis. 2008;67(11):1524–8.CrossRef
Metadata
Title
Comparison of serum inflammatory indicators and radiographic results in MAKO robotic-assisted versus conventional total knee arthroplasty for knee osteoarthritis: a retrospective study of Chinese patients
Authors
Jia-Zheng Xu
Liang-Liang Li
Jun Fu
Chi Xu
Guo-Qiang Zhang
Wei Chai
Li-Bo Hao
Xiang Li
Ji-Ying Chen
Publication date
01-12-2022
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2022
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-022-05373-y