Introduction

Hemolysis is considered a class effect and a rare adverse event that can occur following therapy with human normal immunoglobulin for intravenous administration [i.e., intravenous immunoglobulin (IVIG)]. Anti-A/B isoagglutinins (also referred to as isohemagglutinins) originating from donor plasma are present in polyvalent immunoglobulin G (IgG) products and are considered a probable risk factor for hemolysis. We hypothesized that, by excluding plasma from donors with high isoagglutinin titers, the final IVIG product would have a meaningful reduction in anti-A/B isoagglutinin titers.

Methods

A method for screening donor plasma for anti-A isoagglutinins using an automated indirect agglutination test (IAT) was developed. A cut-off for donor plasma exclusion was defined. Industry-scale donor plasma pools and final IVIG product were prepared according to the manufacturing process of Privigen® (CSL Behring, Berne, Switzerland; human 10% liquid IVIG). Anti-A/B isoagglutinin content in pooled plasma and final IVIG product was measured by IAT, direct agglutination test, and a flow cytometry-based assay [fluorescence-activated cell sorting (FACS) anti-A].

Results

Screening of plasma from 705 donors identified 48 (6.8%) donors with high anti-A isoagglutinin titers in plasma (IAT agglutination score ≥2+ in a 1:200 pre-dilution). Exclusion of plasma from these donors resulted in a one-titer-step reduction of anti-A isoagglutinin in pooled plasma, confirmed by a twofold anti-A isoagglutinin concentration reduction measured by FACS anti-A (1,352 vs. 2,467 µg/g IgG). When the same screening and exclusion were applied to industrial-scale plasma pools (resulting in the exclusion of plasma from 5% of donors), anti-A isoagglutinins were reduced by one titer step in the final IVIG product. Anti-B isoagglutinins were also reduced by one titer step, as many donors with high anti-A isoagglutinins also have high anti-B.

Conclusion

Reduction of anti-A/B isoagglutinin titers in IVIG products on an industrial scale is feasible through implementation of anti-A donor screening, which may reduce the risk of hemolysis following IVIG therapy.
Appendix
Available only for authorised users
Literature
1.
go back to reference Daw Z, Padmore R, Neurath D, et al. Hemolytic transfusion reactions after administration of intravenous immune (gamma) globulin: a case series analysis. Transfusion. 2008;48:1598–601.PubMedCrossRef Daw Z, Padmore R, Neurath D, et al. Hemolytic transfusion reactions after administration of intravenous immune (gamma) globulin: a case series analysis. Transfusion. 2008;48:1598–601.PubMedCrossRef
2.
go back to reference Divan H, Menis M, Sridhar G, et al. Occurrence of hemolytic reactions (HRs) on the same day as immune globulin (IG) product administrations during 2008–2012 (Poster presented at 29th ICPE congress). 2013. Divan H, Menis M, Sridhar G, et al. Occurrence of hemolytic reactions (HRs) on the same day as immune globulin (IG) product administrations during 2008–2012 (Poster presented at 29th ICPE congress). 2013.
3.
go back to reference Padmore RF. Hemolysis upon intravenous immunoglobulin transfusion. Transfus Apher Sci. 2012;46:93–6.PubMedCrossRef Padmore RF. Hemolysis upon intravenous immunoglobulin transfusion. Transfus Apher Sci. 2012;46:93–6.PubMedCrossRef
4.
go back to reference Desborough MJ, Miller J, Thorpe SJ, Murphy MF, Misbah SA. Intravenous immunoglobulin-induced haemolysis: a case report and review of the literature. Transfus Med. 2013 (Epub ahead of print). Desborough MJ, Miller J, Thorpe SJ, Murphy MF, Misbah SA. Intravenous immunoglobulin-induced haemolysis: a case report and review of the literature. Transfus Med. 2013 (Epub ahead of print).
5.
go back to reference MacLennan S. High titre anti-A/B testing of donors within the National Blood Service (NBS). Information document INF/MED/MA/004/02. 2006. MacLennan S. High titre anti-A/B testing of donors within the National Blood Service (NBS). Information document INF/MED/MA/004/02. 2006.
6.
go back to reference Kahwaji J, Barker E, Pepkowitz S, et al. Acute hemolysis after high-dose intravenous immunoglobulin therapy in highly HLA sensitized patients. Clin J Am Soc Nephrol. 2009;4:1993–7.PubMedCentralPubMedCrossRef Kahwaji J, Barker E, Pepkowitz S, et al. Acute hemolysis after high-dose intravenous immunoglobulin therapy in highly HLA sensitized patients. Clin J Am Soc Nephrol. 2009;4:1993–7.PubMedCentralPubMedCrossRef
7.
go back to reference Quillen K, Sheldon SL, Daniel-Johnson JA, Lee-Stroka AH, Flegel WA. A practical strategy to reduce the risk of passive hemolysis by screening plateletpheresis donors for high-titer ABO antibodies. Transfusion. 2011;51:92–6.PubMedCentralPubMedCrossRef Quillen K, Sheldon SL, Daniel-Johnson JA, Lee-Stroka AH, Flegel WA. A practical strategy to reduce the risk of passive hemolysis by screening plateletpheresis donors for high-titer ABO antibodies. Transfusion. 2011;51:92–6.PubMedCentralPubMedCrossRef
8.
go back to reference Thorpe SJ, Fox BJ, Dolman CD, Thorpe R. Anti-A and anti-B activity in batches of different intravenous immunoglobulin products determined using a direct haemagglutination method. Biologicals. 2005;33:111–6.PubMedCrossRef Thorpe SJ, Fox BJ, Dolman CD, Thorpe R. Anti-A and anti-B activity in batches of different intravenous immunoglobulin products determined using a direct haemagglutination method. Biologicals. 2005;33:111–6.PubMedCrossRef
9.
go back to reference Josephson CD, Mullis NC, Van DC, Hillyer CD. Significant numbers of apheresis-derived group O platelet units have “high-titer” anti-A/A, B: implications for transfusion policy. Transfusion. 2004;44:805–8.PubMedCrossRef Josephson CD, Mullis NC, Van DC, Hillyer CD. Significant numbers of apheresis-derived group O platelet units have “high-titer” anti-A/A, B: implications for transfusion policy. Transfusion. 2004;44:805–8.PubMedCrossRef
10.
go back to reference Anti-A and anti-B hemagglutinins (indirect and direct methods). Monograph 07/2011:20620. European Pharmacopoeia. 7th ed. (7.2). Strasbourg: Directorate for the Quality of Medicines of the Council of Europe. 2011. Anti-A and anti-B hemagglutinins (indirect and direct methods). Monograph 07/2011:20620. European Pharmacopoeia. 7th ed. (7.2). Strasbourg: Directorate for the Quality of Medicines of the Council of Europe. 2011.
11.
go back to reference Bellac CL, Polatti D, Hottiger T, et al. Anti-A and anti-B haemagglutinin levels in intravenous immunoglobulins: are they on the rise? A comparison of four different analysis methods and six products. Biologicals. 2014;42:57–64.PubMedCrossRef Bellac CL, Polatti D, Hottiger T, et al. Anti-A and anti-B haemagglutinin levels in intravenous immunoglobulins: are they on the rise? A comparison of four different analysis methods and six products. Biologicals. 2014;42:57–64.PubMedCrossRef
12.
go back to reference Cramer M, Frei R, Sebald A, Mazzoletti P, Maeder W. Stability over 36 months of a new liquid 10% polyclonal immunoglobulin product (IgPro10, Privigen) stabilized with l-proline. Vox Sang. 2009;96:219–25.PubMedCrossRef Cramer M, Frei R, Sebald A, Mazzoletti P, Maeder W. Stability over 36 months of a new liquid 10% polyclonal immunoglobulin product (IgPro10, Privigen) stabilized with l-proline. Vox Sang. 2009;96:219–25.PubMedCrossRef
15.
go back to reference Thomson O. Die Stärken der menschlichen Isoagglutinine und entsprechende Blutkörperchernrezeptoren in verschiedenen Lebensaltern. Z Immunitätsforsch. 1929;63:67–93. Thomson O. Die Stärken der menschlichen Isoagglutinine und entsprechende Blutkörperchernrezeptoren in verschiedenen Lebensaltern. Z Immunitätsforsch. 1929;63:67–93.
Metadata
Title
Isoagglutinin Reduction in Human Immunoglobulin Products by Donor Screening
Authors
Brigitte Siani
Katharina Willimann
Sandra Wymann
Adriano A. Marques
Eleonora Widmer
Publication date
01-12-2014
Publisher
Springer Healthcare
Published in
Biologics in Therapy / Issue 1-2/2014
Print ISSN: 2195-5840
Electronic ISSN: 2190-9164
DOI
https://doi.org/10.1007/s13554-014-0016-2

Other articles of this Issue 1-2/2014

Biologics in Therapy 1-2/2014 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.