Abstract

Percutaneous coronary intervention is the most common treatment of coronary artery disease with the majority of cases undergoing stent implantation. Furthermore, adequate stent deployment is of primary importance to avoid late stent thrombosis and achieve a favorable clinical outcome. Optical coherence tomography (OCT) is a new imaging modality that utilizes advanced photonics and fiberoptics to obtain intravascular images on a microscopic scale. Today, many new drug-eluting stents (DES) are now undergoing clinical trials. Moreover, the intricacies of stent design, local pharmacology, tissue biology, and rheology preclude an intuitive understanding of usability of DES. After stent implantation, assessment should include both the acute and chronic stent/vessel-related changes which include stent malapposition, tissue prolapse, edge dissections, and thrombus formation. OCT plays an indispensable part in determining mechanistic information on the relevance of these phenomena among each DES that cannot be covered by several other modalities.
Literature
1.
go back to reference Bouma BE, Tearney GJ, Yabushita H, Shishkov M, et al. Evaluation of intracoronary stenting by intravascular optical coherence tomography. Heart. 2003;89:317–20.PubMedCrossRef Bouma BE, Tearney GJ, Yabushita H, Shishkov M, et al. Evaluation of intracoronary stenting by intravascular optical coherence tomography. Heart. 2003;89:317–20.PubMedCrossRef
2.
go back to reference Kim U, Kim JS, Lee JM, Son JW, et al. The initial extent of malapposition in st-elevation myocardial infarction treated with drug-eluting stent: the usefulness of optical coherence tomography. Yonsei Med J. 2010;51:332–8.PubMedCrossRef Kim U, Kim JS, Lee JM, Son JW, et al. The initial extent of malapposition in st-elevation myocardial infarction treated with drug-eluting stent: the usefulness of optical coherence tomography. Yonsei Med J. 2010;51:332–8.PubMedCrossRef
3.
go back to reference Tanigawa J, Barlis P, Dimopoulos K, Di Mario C. Optical coherence tomography to assess malapposition in overlapping drug-eluting stents. EuroIntervention. 2008;3:580–3.PubMedCrossRef Tanigawa J, Barlis P, Dimopoulos K, Di Mario C. Optical coherence tomography to assess malapposition in overlapping drug-eluting stents. EuroIntervention. 2008;3:580–3.PubMedCrossRef
4.
5.
go back to reference Cook S, Wenaweser P, Togni M, Billinger M, et al. Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. Circulation. 2007;115:2426–34.PubMedCrossRef Cook S, Wenaweser P, Togni M, Billinger M, et al. Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. Circulation. 2007;115:2426–34.PubMedCrossRef
6.
go back to reference Ozaki Y, Okumura M, Ismail TF, Naruse H, et al. The fate of incomplete stent apposition with drug-eluting stents: an optical coherence tomography-based natural history study. Eur Heart J. 2010;31:1470–6.PubMedCrossRef Ozaki Y, Okumura M, Ismail TF, Naruse H, et al. The fate of incomplete stent apposition with drug-eluting stents: an optical coherence tomography-based natural history study. Eur Heart J. 2010;31:1470–6.PubMedCrossRef
7.
go back to reference Farb A, Sangiorgi G, Carter AJ, Walley VM, et al. Pathology of acute and chronic coronary stenting in humans. Circulation. 1999;99:44–52.PubMed Farb A, Sangiorgi G, Carter AJ, Walley VM, et al. Pathology of acute and chronic coronary stenting in humans. Circulation. 1999;99:44–52.PubMed
8.
go back to reference Schwarzacher SP, Metz JA, Yock PG, Fitzgerald PJ. Vessel tearing at the edge of intracoronary stents detected with intravascular ultrasound imaging. Cathetet Cardiovasc Diagn. 1997;40:152–5.CrossRef Schwarzacher SP, Metz JA, Yock PG, Fitzgerald PJ. Vessel tearing at the edge of intracoronary stents detected with intravascular ultrasound imaging. Cathetet Cardiovasc Diagn. 1997;40:152–5.CrossRef
9.
go back to reference Liu X, Tsujita K, Maehara A, Mintz GS, et al. Intravascular ultrasound assessment of the incidence and predictors of edge dissections after drug-eluting stent implantation. JACC Cardiovasc Interv. 2009;2:997–1004.PubMedCrossRef Liu X, Tsujita K, Maehara A, Mintz GS, et al. Intravascular ultrasound assessment of the incidence and predictors of edge dissections after drug-eluting stent implantation. JACC Cardiovasc Interv. 2009;2:997–1004.PubMedCrossRef
10.
go back to reference •• Gonzalo N, Serruys PW, Okamura T, Shen ZJ, et al. Optical coherence tomography assessment of the acute effects of stent implantation on the vessel wall: a systematic quantitative approach. Heart. 2009;95:1913–9. This study observed and characterized vessel injury after stenting by use of OCT. PubMedCrossRef •• Gonzalo N, Serruys PW, Okamura T, Shen ZJ, et al. Optical coherence tomography assessment of the acute effects of stent implantation on the vessel wall: a systematic quantitative approach. Heart. 2009;95:1913–9. This study observed and characterized vessel injury after stenting by use of OCT. PubMedCrossRef
11.
go back to reference Gonzalo N, Serruys PW, Okamura T, Shen ZJ, et al. Relation between plaque type and dissections at the edges after stent implantation: an optical coherence tomography study. Int J Cardiol. 2010. Gonzalo N, Serruys PW, Okamura T, Shen ZJ, et al. Relation between plaque type and dissections at the edges after stent implantation: an optical coherence tomography study. Int J Cardiol. 2010.
12.
go back to reference Ziada KM, Tuzcu EM, De Franco AC, Kim MH, et al. Intravascular ultrasound assessment of the prevalence and causes of angiographic “haziness” following high-pressure coronary stenting. Am J Cardiol. 1997;80:116–21.PubMedCrossRef Ziada KM, Tuzcu EM, De Franco AC, Kim MH, et al. Intravascular ultrasound assessment of the prevalence and causes of angiographic “haziness” following high-pressure coronary stenting. Am J Cardiol. 1997;80:116–21.PubMedCrossRef
13.
go back to reference Kawaguchi R, Kimura T, Morimoto T, Oshima S, et al. Safety and efficacy of sirolimus-eluting stent implantation in patients with acute coronary syndrome in the real world. Am J Cardiol. 2010;106:1550–60.PubMedCrossRef Kawaguchi R, Kimura T, Morimoto T, Oshima S, et al. Safety and efficacy of sirolimus-eluting stent implantation in patients with acute coronary syndrome in the real world. Am J Cardiol. 2010;106:1550–60.PubMedCrossRef
14.
go back to reference Nakazawa G, Finn AV, Joner M, Ladich E, et al. Delayed arterial healing and increased late stent thrombosis at culprit sites after drug-eluting stent placement for acute myocardial infarction patients: An autopsy study. Circulation. 2008;118:1138–45.PubMedCrossRef Nakazawa G, Finn AV, Joner M, Ladich E, et al. Delayed arterial healing and increased late stent thrombosis at culprit sites after drug-eluting stent placement for acute myocardial infarction patients: An autopsy study. Circulation. 2008;118:1138–45.PubMedCrossRef
15.
go back to reference •• Kubo T, Imanishi T, Kitabata H, Kuroi A, et al. Comparison of vascular response after sirolimus-eluting stent implantation between patients with unstable and stable angina pectoris: a serial optical coherence tomography study. JACC Cardiovasc Imaging. 2008;1:475–84. This study was to compare lesion morphologies after SES implantation between patients with unstable angina pectoris and stable angina pectoris with the use of OCT. PubMedCrossRef •• Kubo T, Imanishi T, Kitabata H, Kuroi A, et al. Comparison of vascular response after sirolimus-eluting stent implantation between patients with unstable and stable angina pectoris: a serial optical coherence tomography study. JACC Cardiovasc Imaging. 2008;1:475–84. This study was to compare lesion morphologies after SES implantation between patients with unstable angina pectoris and stable angina pectoris with the use of OCT. PubMedCrossRef
16.
go back to reference Fan C, Kim J-S, Lee JM, Kim TH, et al. Different vascular healing patterns with various drug-eluting stents in primary percutaneous coronary intervention for st-segment elevation myocardial infarction: optical coherence tomographic findings. Am J Cardiol. 2010;105:972–6.PubMedCrossRef Fan C, Kim J-S, Lee JM, Kim TH, et al. Different vascular healing patterns with various drug-eluting stents in primary percutaneous coronary intervention for st-segment elevation myocardial infarction: optical coherence tomographic findings. Am J Cardiol. 2010;105:972–6.PubMedCrossRef
17.
go back to reference Finn AV, Joner M, Nakazawa G, Kolodgie F, et al. Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation. 2007;115:2435–41.PubMedCrossRef Finn AV, Joner M, Nakazawa G, Kolodgie F, et al. Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation. 2007;115:2435–41.PubMedCrossRef
18.
go back to reference Sonoda S, Morino Y, Ako J, Terashima M, et al. Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial. J Am Coll Cardiol. 2004;43:1959–63.PubMedCrossRef Sonoda S, Morino Y, Ako J, Terashima M, et al. Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial. J Am Coll Cardiol. 2004;43:1959–63.PubMedCrossRef
19.
go back to reference Suzuki Y, Ikeno F, Koizumi T, Tio F, et al. In vivo comparison between optical coherence tomography and intravascular ultrasound for detecting small degrees of in-stent neointima after stent implantation. JACC: Cardiovasc Interv. 2008;1:168–73.CrossRef Suzuki Y, Ikeno F, Koizumi T, Tio F, et al. In vivo comparison between optical coherence tomography and intravascular ultrasound for detecting small degrees of in-stent neointima after stent implantation. JACC: Cardiovasc Interv. 2008;1:168–73.CrossRef
20.
go back to reference Kume T, Akasaka T, Kawamoto T, Watanabe N, et al. Visualization of neointima formation by optical coherence tomography. Int Heart J. 2005;46:1133–6.PubMedCrossRef Kume T, Akasaka T, Kawamoto T, Watanabe N, et al. Visualization of neointima formation by optical coherence tomography. Int Heart J. 2005;46:1133–6.PubMedCrossRef
21.
go back to reference Finn AV, Nakazawa G, Joner M, Kolodgie FD, et al. Vascular responses to drug eluting stents: importance of delayed healing. Arterioscler Thromb Vasc Biol. 2007;27:1500–10.PubMedCrossRef Finn AV, Nakazawa G, Joner M, Kolodgie FD, et al. Vascular responses to drug eluting stents: importance of delayed healing. Arterioscler Thromb Vasc Biol. 2007;27:1500–10.PubMedCrossRef
22.
go back to reference Nishiguchi T, Kitabata H, Tanaka A, Kataiwa H, et al. Very late stent thrombosis after drug-eluting stent in segment with neointimal tissue coverage. JACC Cardiovasc Imaging. 2010;3:445–6.PubMedCrossRef Nishiguchi T, Kitabata H, Tanaka A, Kataiwa H, et al. Very late stent thrombosis after drug-eluting stent in segment with neointimal tissue coverage. JACC Cardiovasc Imaging. 2010;3:445–6.PubMedCrossRef
23.
go back to reference Kume T, Akasaka T, Kawamoto T, Ogasawara Y, et al. Assessment of coronary arterial thrombus by optical coherence tomography. Am J Cardiol. 2006;97:1713–7.PubMedCrossRef Kume T, Akasaka T, Kawamoto T, Ogasawara Y, et al. Assessment of coronary arterial thrombus by optical coherence tomography. Am J Cardiol. 2006;97:1713–7.PubMedCrossRef
24.
go back to reference Kume T, Okura H, Kawamoto T, Akasaka T, et al. Images in cardiovascular medicine. Fibrin clot visualized by optical coherence tomography. Circulation. 2008;118:426–7.PubMedCrossRef Kume T, Okura H, Kawamoto T, Akasaka T, et al. Images in cardiovascular medicine. Fibrin clot visualized by optical coherence tomography. Circulation. 2008;118:426–7.PubMedCrossRef
25.
go back to reference Finn AV, Kolodgie FD, Harnek J, Guerrero LJ, et al. Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents. Circulation. 2005;112:270–8.PubMedCrossRef Finn AV, Kolodgie FD, Harnek J, Guerrero LJ, et al. Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents. Circulation. 2005;112:270–8.PubMedCrossRef
26.
go back to reference Tanigawa J, Barlis P, Dimopoulos K, Dalby M, et al. The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography. Int J Cardiol. 2009;134:180–8.PubMedCrossRef Tanigawa J, Barlis P, Dimopoulos K, Dalby M, et al. The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography. Int J Cardiol. 2009;134:180–8.PubMedCrossRef
27.
go back to reference Guagliumi G, Musumeci G, Sirbu V, Bezerra HG, et al. Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents. JACC Cardiovasc Interv. 2010;3:531–9.PubMedCrossRef Guagliumi G, Musumeci G, Sirbu V, Bezerra HG, et al. Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents. JACC Cardiovasc Interv. 2010;3:531–9.PubMedCrossRef
28.
go back to reference Glagov S, Zarins C, Giddens DP, Ku DN. Hemodynamics and atherosclerosis. Insights and perspectives gained from studies of human arteries. Arch Pathol Lab Med. 1988;112:1018–31.PubMed Glagov S, Zarins C, Giddens DP, Ku DN. Hemodynamics and atherosclerosis. Insights and perspectives gained from studies of human arteries. Arch Pathol Lab Med. 1988;112:1018–31.PubMed
29.
go back to reference Gonzalo N, Garcia-Garcia HM, Regar E, Barlis P, et al. In vivo assessment of high-risk coronary plaques at bifurcations with combined intravascular ultrasound and optical coherence tomography. JACC Cardiovasc Imaging. 2009;2:473–82.PubMedCrossRef Gonzalo N, Garcia-Garcia HM, Regar E, Barlis P, et al. In vivo assessment of high-risk coronary plaques at bifurcations with combined intravascular ultrasound and optical coherence tomography. JACC Cardiovasc Imaging. 2009;2:473–82.PubMedCrossRef
30.
go back to reference Costa RA, Mintz GS, Carlier SG, Lansky AJ, et al. Bifurcation coronary lesions treated with the “crush” technique: an intravascular ultrasound analysis. J Am Coll Cardiol. 2005;46:599–605.PubMedCrossRef Costa RA, Mintz GS, Carlier SG, Lansky AJ, et al. Bifurcation coronary lesions treated with the “crush” technique: an intravascular ultrasound analysis. J Am Coll Cardiol. 2005;46:599–605.PubMedCrossRef
31.
go back to reference Di Mario CLL, van der Giessen WJ, Foin N. Optical coherence tomography for guidance in bifurcation lesion treatment. EuroIntervention. 2010;6(Supplement J):J99–106. Di Mario CLL, van der Giessen WJ, Foin N. Optical coherence tomography for guidance in bifurcation lesion treatment. EuroIntervention. 2010;6(Supplement J):J99–106.
32.
go back to reference Tyczynski P, Ferrante G, Kukreja N, Moreno-Ambroj C, et al. Optical coherence tomography assessment of a new dedicated bifurcation stent. EuroIntervention. 2009;5:544–51.PubMedCrossRef Tyczynski P, Ferrante G, Kukreja N, Moreno-Ambroj C, et al. Optical coherence tomography assessment of a new dedicated bifurcation stent. EuroIntervention. 2009;5:544–51.PubMedCrossRef
33.
go back to reference Teramoto T, Ikeno F, Otake H, Lyons JK, et al. Intriguing peri-strut low-intensity area detected by optical coherence tomography after coronary stent deployment. Circ J. 2010;74:1257–9.PubMedCrossRef Teramoto T, Ikeno F, Otake H, Lyons JK, et al. Intriguing peri-strut low-intensity area detected by optical coherence tomography after coronary stent deployment. Circ J. 2010;74:1257–9.PubMedCrossRef
34.
go back to reference Nagai H, Ishibashi-Ueda H, Fujii K. Histology of highly echolucent regions in optical coherence tomography images from two patients with sirolimus-eluting stent restenosis. Catheter Cardiovasc Interv. 2010;75:961–3.PubMed Nagai H, Ishibashi-Ueda H, Fujii K. Histology of highly echolucent regions in optical coherence tomography images from two patients with sirolimus-eluting stent restenosis. Catheter Cardiovasc Interv. 2010;75:961–3.PubMed
35.
go back to reference Otake H, Shite J, Ikeno F, Shinke T, et al. Evaluation of the peri-strut low intensity area following sirolimus- and paclitaxel-eluting stents implantation: Insights from an optical coherence tomography study in humans. Int J Cardiol. 2010. Otake H, Shite J, Ikeno F, Shinke T, et al. Evaluation of the peri-strut low intensity area following sirolimus- and paclitaxel-eluting stents implantation: Insights from an optical coherence tomography study in humans. Int J Cardiol. 2010.
36.
go back to reference Kastrati A, Koch W, Berger PB, Mehilli J, et al. Protective role against restenosis from an interleukin-1 receptor antagonist gene polymorphism in patients treated with coronary stenting. J Am Coll Cardiol. 2000;36:2168–73.PubMedCrossRef Kastrati A, Koch W, Berger PB, Mehilli J, et al. Protective role against restenosis from an interleukin-1 receptor antagonist gene polymorphism in patients treated with coronary stenting. J Am Coll Cardiol. 2000;36:2168–73.PubMedCrossRef
Metadata
Title
Intracoronary Optical Frequency Domain Imaging for Identifying Stent-Related Complications
Authors
Shigeho Takarada
Morton J. Kern
Takashi Akasaka
Publication date
01-08-2011
Publisher
Current Science Inc.
Published in
Current Cardiovascular Imaging Reports / Issue 4/2011
Print ISSN: 1941-9066
Electronic ISSN: 1941-9074
DOI
https://doi.org/10.1007/s12410-011-9088-2

Other articles of this Issue 4/2011

Current Cardiovascular Imaging Reports 4/2011 Go to the issue